Now everyone can help save a life The Facts • Coronary heart disease (mainly heart attacks) was the leading single cardiovascular cause of death, accounting for 27,825 deaths (22% of all deaths) in Australia in 1998.1 • Around 5-10 Australians die each day of out-of-hospital sudden cardiac arrest.2 • The current survival rate from sudden cardiac arrest is less then 5%.3 • By having the AED no more than a minute away the chance of survival could rise to over 80%. For every minute defibrillation is delayed the chance of survival decreases by about 10%.4 Fast to learn So simple to operate that a first aider with minimal training can help save the life of a co-worker, friend, member of the family or the public. Easy to use Calming natural voice instructions coach the first aider through the steps of first aid defibrillation. If required, calming instructive voice prompts will also guide the user in delivering CPR. Always ready Comprehensive automatic self-tests check all the HeartStart First Aid’s vital functions on a daily, weekly and monthly schedule, so as to ensure that HeartStart First Aid is always ready for emergency life saving. HeartStart First Aid is safe and effective SMART Analysis; so accurate that HeartStart First Aid is the only automated external defibrillator approved for use on children as well as adults. SMART Biphasic Low energy 150-Joule shock; the only defibrillation waveform to have international guidelines approval. SMART Pads are able to sense whether they have been removed from the cartridge and placed on the patient’s chest so as to ensure that the voice prompts keep pace with you. Ordering information M5067A HeartStart First Aid Defibrillator, HS1 How supplied: HeartStart First Aid Semi-Automatic External Defibrillator, Battery, Adult Pad Cartridge (2 pc.), Quick Reference Card, Users Guide 941340 Carry Case HS1 Standard (space for spare battery and pads) 941341 Carry Case HS1 Slim type HeartStart Carry Cases come with an accessory kit containing Laerdal Face Shield, scissors and a paper cloth Accessories: M5071A M5072A M5073A M5074A Adult SMART Pads (1 pair) Infant/Child SMART Pads (1 pair) Adult Training Pads (1 pair) Infant/Child Training Pads (1 pair) M5070A Battery for HeartStart First Aid HS1 Lithium manganese dioxide battery, 9VDC 4,2 Ah Capacity: When new minimum 90 shocks or 3 hours of operating time Shelf life: A minimum of 5 years (prior to insertion) Stand by life: Typical 4 years (after insertion) Training life: A minimum of 10 hours of use in training mode Data management: ACT-IR Datacable for HeartStart First Aid HS1 M3834A HeartStart Event Review Software 1.Australian Institute of Health and Welfare (AIHW) 2001. Heart, stroke and vascular diseases: Australian Facts 2001. AIHW Cat No. CVD 13. Canberra: AIHW, National Heart Foundation of Australia, National Stroke Foundation of Australia (Cardiovascular Disease Series No. 14). 2. Australian Bureau of Statistics 3303.0 Causes of Death, Australia, 1998. 3. Meyer ADM, Cameron PA, Smith KL, et al. Out-of-hospital cardiac arrest. Med J Aust 2000; 172: 73-76. Bernard S. Outcome from prehospital cardiac arrest in Melbourne, Australia. Emerg Med 1998; 10: 25-29. 4. AHA 2000 Guidelines. Australia: LAERDAL Pty. Ltd. 23 Edward Street, Oakleigh,Victoria 3166 Toll free phone: 1800 331 565 Toll free fax: 1800 635 835 E-mail: [email protected] New Zealand: Laerdal New Zealand Ltd PO Box 302664, North Harbour, Auckland 1330 Toll free phone: 0800 523 732 Toll free fax: 0800 528 852 E-mail: [email protected] www.heartstart.com.au www.heartstart.co.nz
© Copyright 2026 Paperzz