JUMO GmbH & Co. KG Hausadresse: Moritz-Juchheim-Straße 1, 36039 Fulda, Germany Lieferadresse: Mackenrodtstraße 14, 36039 Fulda, Germany Postadresse: 36035 Fulda, Germany Telefon: Telefax: E-Mail: Internet: +49 661 6003-727 +49 661 6003-508 [email protected] www.jumo.net Data sheet 700755 Page 1/4 JUMO SVS3000 Plant visualization software with batchrelated data reporting and evaluation in a network Brief description JUMO SVS3000 is a visualization software program that can run on Windows. Predefined graphic elements are provided in a library, specifically for the connection of JUMO devices. This reduces the creation of applications down to a simple plant configuration and shortens software project planning considerably. Data can be visualized as a real-time or historic trend. Extensive reporting functions with batch-related report evaluation can archive the data for an adjustable period of time. An existing PC network can be used to transfer SVS3000 plant data between several PCs. Each PC can record up to 50 plants, independently of one another. In a PC network, a single PC can view reports for up to 100 plants. One report, recipes, grouped mimics (group displays), 8 timetables, and 16 trend displays are available for each plant. Easy creation of applications Open architecture can be expanded with PCVUE software functions SVS3000 Configuration / parameterization Recording Parameterization / configuration 2013-05-01/00495002 - Predefined graphic objects for JUMO devices - Simple and fast creation of an application - Input of formulae Operation Visualization Reporting Printer k Quick and simple creation of the application by using predefined graphic objects for JUMO devices Data recording JUMO devices Additional software: - Barcode reading Network functionality k Visualization and reporting can be freely defined for each station Block diagram of a station PC hardware minimum requirements: - PC with Pentium 4 processor or compatible - 1.0 GHz for 32-bit system (x86) - 1.4 GHz for 64-bit system (x64) - 512 MB main memory - One free serial port for communication with the devices - Or one free PCI port for the interface card - For Windows XP 1 GB - For Windows Vista, Windows 7, Windows Server 2003 and 2008, 2 GB free hard disk space for the SVS3000 software - 20 GB for archive data - Resolution: XVGA graphics 1024 × 768 or 1280 × 1024 pixels - USB for hardlock - USB for mouse connection - USB for printer connection - DVD drive for installation of SVS3000 Software requirements: - Windows XP 32-bit version (Service Pack 2 or higher), Windows Vista, or Windows 7 - Internet Explorer 7 or higher Special features Output data - 16 trend displays per plant - 64 grouped mimics (group displays) per plant - 24 flow diagrams - Alarm and event lists - Recipes - Math function - Timetable function - Batch-related recording and evaluation - Search functions - Data export in ASCII k Batch-related and continuous reporting and data recording for the processes k Batch reporting with a search function for date and time, plant, and 3 freely definable batch criteria, such as program name, batch number, etc. k Adjustable automatic printout and data export to ASCII files Display k Arrange predefined graphic objects and trend displays in grouped mimics (group displays) as required k Plant-specific alarm and event lists Real-time operation k Grouped mimics (group displays), trend displays, and alarm or event lists k With specifically set-up variables, editable (e.g. setpoint values) k The sampling rate per interface and per connected device is between 0.7 and 2 seconds Data sheet 700755 Other functions - Page 2/4 Drivers for linking JUMO devices Password-protected access rights - Recipe function - Expandable software functions through open architecture under PCVUE 32 Type Description Bus protocol Further info, see data sheet Modbus 202530 dTRANS pH 01 Transmitter/controller for pH value - 3 languages: German, English, and French, on request dTRANS Rd 01 Transmitter/controller for redox potential dTRANS Lf 01 Transmitter/controller for conductivity 202540 - A maximum of 50 plants can be managed and 100 displayed on each PC dTRANS Rw 01 Transmitter/controller for high-purity water 202545 Variable pricing, with the following upgrade levels dTRANS Az 01 Indicator/controller for electrochemical values 202550 - Economical entry, with 75 I/O variables IMAGO F3000 Process control for the meat processing Modbus industry 700101 - 250 I/O variables dTRON 304, 308, Compact controller with 316 program function - 1000 I/O variables - 5000 I/O variables Training/seminars Training courses and seminars for the JUMO SVS3000 are held regularly in our training center. For information on available courses and dates, please contact our training manager: Manfred Schleicher Phone +49 (6 61) 60 03-3 96 202535 Modbus 703041 DICON 400/500 Universal process controller Modbus 703570 IMAGO 500 Multichannel program controller Modbus 703590 LOLGOLINE 500 Pen recorder with text printing Modbus 706000 LOGOSCREEN 500 cf 3/6 channel paperless recorder Modbus 706510 LOGOPRINT 500 Printing recorder Modbus 706030 LOGOSCREEN cf 6/12 channel paperless recorder Modbus 706570 LOGOSCREEN nt 3-18 channel paperless recorder Modbus Modbus TCP/IP 706581 Wtrans receiver Wireless data transmission Modbus 902931 Scope of delivery cTRON Compact controller with timer and ramp Modbus function 702070 1 CD SVS3000 1 hardlock dongle either for USB or parallel interface 1 quick reference guide eTRON M100 Electronic cooling controller or electronic Modbus 2-channel microstat 701061 di308 Digital indicator Modbus 701550 mTRON T modules Modules from the automation system JUMO mTRON T Modbus Modbus TCP/IP 705001 to 705060 Additional software Remote-control software TeamViewer This software includes the option to operate all plant functions remotely, from any location, via modem or through the network. These devices are no longer part of the delivery program but can be linked with SVS3000: LPF-100/200 3-channel program controller Modbus via communication module LKR-96 Controller for boilers PRF and PR-100 Process control system for Modbus meat processing dTRON 16.1 Process controller Modbus dTRON 04.1 dTRON 08.1 Process controller Modbus DICON 401/501 Program controller/generator Modbus DICON 1000, 1001 Process controller, controller 703580 program Modbus DICON SM Compact controller LOGOSCREEN Paperless recorder Modbus LOGOSCREEN 500 Paperless recorder Modbus mTRON modules Modules from the automation system JUMO mTRON Modbus via communication module 704010 to 704090 Barcode readers 2013-05-01/00495002 Barcode readers are connected via RS232 or USB, like JUMO devices, or are looped directly into the keyboard connection to the PC. WinWedge software uses DDE for data exchange to the SVS3000. Data sheet 700755 Function principle of SVS3000 SVS3000 provides supervisory and plantspecific visualization facilities. The higher-level (supervisory), non plantspecific group displays and flow diagrams (optional), as well as global alarm and event lists, provide an overall view of all connected devices. The detailed data for the individual plants is assigned in the plantspecific section. This pre-selection means that only the plant-specific data for reports, trend displays, plant-specific grouped mimics (group displays), and recipes are available in a plant. In this way, an individual plant overview and simple operation can be implemented to suit the application. Structure of the network stations Data for entire plant Grouped mimic (group display): Station: master Event list: Displays events in chronological order; type of event to be shown can be adjusted Displays the predefined graphic objects of the JUMO devices and trend displays at the same time Alarm list: Flow diagram (option): Displays all alarms and the current status of these alarms in various colors Customer-specific flow diagram with current process variables Plant-specific Plant 1 8 timetables 16 trend displays Grouped mimics (group displays) Reports with: - Batch data - Comment texts - Events - Trend diagram 64 recipes Freely usable math function Operating functions: - Program start and program stop - Alter setpoint values - Alter controller parameters Plant 50 8 timetables 16 trend displays Grouped mimics (group displays) Reports with: - Batch data - Comment texts - Events - Trend diagram 64 recipes Freely usable math function Operating functions: - Program start and program stop - Alter setpoint values - Alter controller parameters Network Station: production 1 Station: production 50 Data for the entire plan Grouped mimic (group display): Data for the entire plan Event list: Displays events in chronological order; type of event to be shown can be adjusted Displays the predefined graphic objects of the JUMO devices and trend displays at the same time Alarm list: Displays all alarms and the current status of these alarms in various colors Grouped mimic (group display): Alarm list: Flow diagram (option): Customer-specific flow diagram with current process variables Displays all alarms and the current status of these alarms in various colors Plant-specific Displays events in chronological order; type of event to be shown can be adjusted Flow diagram (option): Customer-specific flow diagram with current process variables Plant-specific Plant 1 8 timetables 16 trend displays Grouped mimics (group displays) Reports with: - Batch data - Comment texts - Events - Trend diagram 64 recipes Freely usable math function Operating functions: - Program start and program stop - Alter setpoint values - Alter controller parameters Event list: Displays the predefined graphic objects of the JUMO devices and trend displays at the same time Plant 1 Plant 50 8 timetables 16 trend displays Grouped mimics (group displays) Reports with: - Batch data - Comment texts - Events - Trend diagram 64 recipes Freely usable math function Operating functions: - Program start and program stop - Alter setpoint values - Alter controller parameters 8 timetables 16 trend displays Grouped mimics (group displays) Reports with: - Batch data - Comment texts - Events - Trend diagram 64 recipes Freely usable math function Operating functions: - Program start and program stop - Alter setpoint values - Alter controller parameters Plant 50 8 timetables 16 trend displays Grouped mimics (group displays) Reports with: - Batch data - Comment texts - Events - Trend diagram 64 recipes Freely usable math function Operating functions: - Program start and program stop - Alter setpoint values - Alter controller parameters Example: grouped mimic Example: flow diagram 2013-05-01/00495002 Page 3/4 Data sheet 700755 Page 4/4 Visualization Reporting Accessories 64 grouped mimics A reporting function is available for up to 50 plants per PC. The reports for up to 100 plants can be called up over the network. - Interface card with 2, 4, or 8 × RS232 or RS422 interfaces - At a resolution of 1024 × 768, up to 24 visualization objects can be combined to form a grouped mimic (group display) - At a resolution of 1280 × 1024, up to 45 visualization objects can be combined to form a grouped mimic (group display) - Windows for operating the connected devices, such as: -Program start and stop -Alteration of the setpoint value -Alteration of controller parameters -Controller changeover between manual and automatic modes - Trend display of current process data 24 flow diagrams - Animation of the flow diagrams by JUMO, customer-specific Event list Report types - Batch processes - Continuous processes (shift, daily, weekly, or monthly reports) Report data - Analog and binary signals (trend diagram) - Events - Batch criteria, such as program name, batch number, etc. - Customer-specific text and definition of a standard form sheet - Up to eight different products can be recorded in one report - Starting and stopping report recording by time; input in the screen template, or via device variables - Chronological listing of all events Report evaluation - Plant-specific selection Search function Alarm list - Plant - Display of all alarms - Three editable batch criteria such as program name, batch number, etc. - Overall list or plant-specific selection Recipes - Create and transmit Math processing 64 different formulae can be calculated - Free entry of formulae Timetable function - Calendar function for one year - Date and time Data export - Export of data in ASCII format for further processing in spreadsheet programs, for example - Selection options for the data to be exported - Automatic or manual data export Data printout - Report data in the form of a trend display or list - Event list - Freely editable text comments - Batch data - Calculation of minimum, maximum, and average values - Automatic or manual data printout 2013-05-01/00495002 - RS232 to RS422/485 interface converter - Program editor as PC software for the program controller concerned Setup programs The setup programs or program editors can be accessed from SVS3000.
© Copyright 2026 Paperzz