Overview VEGAPULS Area of application Radar sensors of the VEGAPULS series are used for non-contact level measurement of liquids and bulk solids. They measure all kinds of liquids, even under high pressure and extreme temperatures. They can be used in simple as well as in aggressive liquids and are suitable for applications with stringent hygiene requirements. The sensors measure light as well as heavy bulk solids with absolute reliability, even in the presence of dust and noise, and without being affected by buildup or condensation. Measuring principle The measuring instrument sends out short radar pulses toward the measured product via the antenna system. The product surface reflects the signal waves, which are then received back by the antenna system. The instrument calculates the level from the running time of the radar pulses and the entered tank height. Advantages Non-contact radar technology is characterized by a particularly high measurement accuracy. The measurement is affected neither by fluctuating product properties nor by changing process conditions such as temperature, pressure or intense dust generation. User-friendly adjustment without vessel filling and emptying saves time. 6 VEGAPULS 62 Radar sensor for continuous level measurement of liquids Application area The VEGAPULS 62 is a universally implementable radar sensor for continuous level measurement of liquids. It is suitable for level measurement in storage containers, reactors and process vessels, even under difficult process conditions. With its various antenna versions and materials, VEGAPULS 62 is the optimal solution for almost all applications and processes. Its wide temperature and pressure range makes project planning simple. Your benefit − Maintenance-free operation through non-contact measuring principle − High plant availability, because wear and maintenance-free − Exact measuring results independent of pressure, temperature, gas and steam Technical data Measuring range: Process fitting: up to 35 m thread from G1½, 1½ NPT flanges from DN 50, 2" -196 … +450 °C -1 … +160 bar (-100 … +16000 kPa) ±2 mm optionally up to SIL2 Process temperature: Process pressure: Measuring accuracy: SIL qualification: 37,5 mm (1.4,8") Delivery time: 100 mm (3.94") 142 mm (5.59") 22 mm (0.87") G1½ 59,5 mm (2.34") SW 46 mm (1.81") 1 3 Antenna-ø Length 40 mm 100 mm Beam angle 20° 48 mm 120 mm 15° 75 mm 216 mm 10° 95 mm 430 mm 8° 245 mm (parabolic) 138 mm 3° ø 40 mm (1.58") 2 ① Threaded version ② Threaded version with temperature adapter up to +250 °C ③ Flange version The options shown represent only a limited selection. Additional instrument options and possible restrictions. www.vega.com/configurator Instrument documentation and drawings: www.vega.com/downloads Mounting accessories, welded sockets and housing overview: Chapter Accessory 14 Operating Instructions TDR sensor for continuous level and interface measurement of liquids VEGAFLEX 81 Profibus PA Rod and cable probe Document ID: 44217 11 Supplement SW 36 (1.42") (G¾, ¾ NPT) SW 41 (1.61") (G1, 1 NPT) SW 46 (1.81") (G1½, 1½ NPT) ø 4 mm (0.16") L L 22 mm (0.87") 22 mm (0.87") G¾, ¾ NPT, G1, 1 NPT, G1½, 1½ NPT 96 mm (3.78") 46 mm (1.81") VEGAFLEX 81, cable version with gravity weight ø 4 mm (0.16") ø 16 mm (0.63") 44217-EN-140430 ø 20 mm (0.79") 1 2 100 mm (3.94") 50 mm (1.97") 100 mm (3.94") ø 2 mm (0.08") ø 16 mm (0.63") ø 16 mm (0.63") ø 20 mm (0.79") ø 20 mm (0.79") 3 Fig.66:VEGAFLEX81,threadedversionwithgravityweight(allgravityweightswiththreadM8foreye-bolt) L Sensorlength,seechapter"Technicaldata" VEGAFLEX 81 • Profibus PA 93 Pulse Burst Radar Level Transmitter D E S C R I P T I O N The Pulsar® Radar transmitter is the latest generation of loop-powered, 24 VDC, level transmitters. It has lower power consumption, faster response time and is easier to use than most loop-powered radar transmitters. This latest entry into the radar level measurement field is designed to provide unparalleled performance and ease of use. PULSAR non-contact radar is the perfect compliment to the Magnetrol® Eclipse® Guided Wave Radar. These transmitters offer the ultimate solution to the vast majority of process level applications. T E C H N O L O G Y The PULSAR Radar transmitter is based on pulse burst radar technology together with equivalent time sampling circuitry. Short bursts of 5.8 or 6.3 GHz microwave energy are emitted and subsequently reflected from the liquid level surface. Distance is calculated by the equation D = Transit time (round-trip)/2. Liquid level is then calculated by applying the tank height value. A P P L I C A T I O N S MEDIA: Liquids and slurries; hydrocarbons to water based media (dielectric 1.7–100) VESSELS: Most process or storage vessels up to rated temperature and pressure. Pits and sumps as well as non-metallic tanks such as plastic, glass-lined and concrete. CONDITIONS: Virtually all level measurement and control applications including process conditions exhibiting varying specific gravity and dielectric, visible vapors, high fill/empty rates, turbulence, low to moderate foam and buildup. F E A T U R E S • Two-wire, 24 VDC loop-powered level transmitter • PACTware™ PC Program using HART® communication for advanced configuration and troubleshooting. (see bulletin 59-101) • Performance not process dependent (changing specific gravity and dielectric have no effect) • 5.8/6.3 GHz operating frequency offers superior performance in the tougher applications of turbulence, foam, and heavy vapors • False Target setup is simple, intuitive and effective • Will reliably track extremely rapid rate of change up to 180 inches (450 cm)/minute • Antenna designs to +400° F (+204° C), -14.7 to 750 psig (-1.0 to 51.7 bar) • Range up to 65 feet (20 meters) • Quick connect/disconnect antenna coupling allows vessel to remain sealed (patent pending) • Extremely low output at antenna: < .01 mW (avg), < 2 mW (max); hundreds of times less than a cell phone • Safety Integrity Level (SIL) value of 1 (SFF 73.7%) A P P L I C A T I O N S P U L S E B U R S T S T O R A G E A N D R A D A R I N T E R M E D I A T E H O L D I N G T A N K S CONDITIONS – Calm Surfaces R E A C T O R S E N C L O S E D CONDITIONS – Turbulence and Foam CONDITIONS – Turbulence, Foam, and Changing Dielectric 2 S U M P S A P P L I C A T I O N S P U L S E B U R S T M I X E R S A N D R A D A R B L E N D I N G V E S S E L S CONDITIONS – Turbulence, Foam, and Changing Dielectric C H A M B E R S A N D B Y P A S S P R O B L E M A T I C G U I D E D W A V E A P P L I C A T I O N S R A D A R A L T E R N A T I V E Some applications can be problematic for Pulse Burst Radar. The following are examples of when Guided Wave Radar is recommended. • Extremely low dielectric media (εr<2.0) • Very weak reflections from the liquid surface— particularly during turbulence can cause poor performance. • Tanks heavily cluttered with false targets (mixers, pumps, ladders, pipes, etc.) • During times of very low liquid levels of low dielectric media, the metal tank bottom may be detected deteriorating performance. • Foam can either absorb or reflect the microwave energy depending upon the depth, dielectric, density and wall thickness of the bubbles. Due to typical variations in the amount (depth) of foam, it is impossible to quantify performance. It may be possible to receive most, some or none of the transmitted energy. • Extremely high liquid level (Overflow) conditions when liquid very near the antenna can cause erroneous readings and measurement failure. Refer to ECLIPSE Guided Wave Radar bulletin 57-101. 3
© Copyright 2026 Paperzz