COR-A-VENT ® Installation and Information Guide. Easy Installation: One person can easily install the handy four-foot COR-A-VENT sections. All you need is a hammer, circular saw, chalk line, utility knife, tape measure and a caulking gun. Here’s an installation overview for a standard pitch* gable roof application: ® Important–close off exposed center openings at both ridge ends to prevent infiltration. 1. Measure a 3" slot, 11/2" each side of ridge centerline. This allows for a 2x ridge board or smaller. Snap chalk lines the entire length of the ridge. Cut slot with a circular saw and clean out debris. Set saw depth so as not to cut roof rafters. Stop the slot 12" short of any ridge end, intersecting ridge or obstruction (such as a chimney). If Architectural Shingles, Shakes or roofing with an irregular surface is used, apply a bead of caulk to roof deck before installing vent. This will seal any gaps that could allow weather penetration under the vent. 2. Nail one shingle cap at each end of the ridge, as with conventional application. Use End Plug in the exposed end on first and last sections of vent, caulk in place. Center first piece on ridge and nail, keeping end of vent 1/2" from end of roof. Set 4 nails 1/2" from ends and 2" up from edge on each corner of vent, add 2 nails in center of vent 2" up from edge. Repeat this step at the other end of the ridge. For V-300, use the Folded End Cap technique shown on back page. 2" 3. Continue applying COR-A-VENT, working from ends to middle. This technique helps remove any dips or sag in the ridge. Align center with previous pieces, making sure vent matches roof pitch before nailing. Continue nailing until entire ridge is covered. Use a utility knife to cut last piece to length. Caulk where bottom edge of end caps rest on roof. 4. Center shingle cap on vent and nail. Nail line for cap shingles is to be 2" – 21/2" up from edge. Continue nailing until all vent is covered with ridge caps. Be careful not to overdrive nail. Nail head should be flush with top of shingle, without indenting it. Pre-forming caps in cold weather helps avoid cracking. Be sure to use fasteners** long enough to penetrate vent and roof deck when nailing the vent and ridge cap on. Heavyweight, architectural and re-roof installations require a longer nail than the standard installation. In high wind areas, use a washer headed nail to prevent shingle cap “blow off”. Or, apply a 1/4" to 3/8" bead of roof cement between the ridge caps, 3/4" up from the bottom edge of shingles parallel to ridge. COR-A-VENT Ridge Vents are sized for residential and light commercial buildings up to 60 feet wide. Please call COR-A-VENT before using our ridge vents on buildings wider than 60 feet. *Standard applications V-300® or V-600® – 3/12 - 16/12 pitch. For steeper pitch/wide ridge beam applications see complete installation sheet or see us on the web at www.cor-a-vent.com. **Nail requirements for standard vent and ridge cap installation: V-600 - 21/2" roofing nail, V-300 - 11/2" (with 3 tab shingles installed on new construction or after complete roof tear off). Hip Installation Instructions End Views COR-A-VENT RIDGE VENTS W/ENHANCED SNOW SCREEN END VIEWS TYPICAL If the ridge length is too short to install the recommended amount of ventilation, COR-A-VENT® V-300®E, FAV-20E (Fold-A-Vent®), or V-600®E may be installed in equal lengths on the upper half of the hips. These instructions can be used for most shingle, shake or slate applications. If jack rafters are 16" on center, cut the slot per our ridge installation instructions. If jack rafters are 24" on center, blocking may be needed to prevent the roof sheathing from sagging. Cut 2" x 4" blocks 8" long, and using 16-penny nails, nail blocks between jack rafters and flush with bottom of roof sheathing. Cut the slot per our ridge installation instructions. The blocks will provide support for the roof sheathing. Nail roof sheathing to blocks with 8-penny nails. See Fig. A below. Note: When using blocking, allow for a loss of 25% in ventilation due to the blocks. The slot normally does not need to be cut more than half way down the hips for open attic roofs. The vent may be run all the way down to the end of the roof for appearance reasons, BUT DO NOT CUT A SLOT UNDER IT! This will insure that the air is drawn in from the soffit inlet vents and exhausted out through the ridge and/or hip vents. If it is an ALL cathedral ceiling roof then the slot must not be cut any closer than 3 feet up from the outside wall of the building. This will prevent any ice build up from leaking back into the building. In areas that receive heavy snowfall, the slot should stop 6 feet up from the outside wall of the house. The vent may be run all the way down to the end of the roof for appearance reasons, BUT DO NOT CUT A SLOT UNDER IT! See Fig. B below for details on how to cut the vent where the hips and ridge come together. The vent can be cut with a utility knife. Caulk all joints with black silicon caulking. Also, caulk end joints on the vent coming up the hip. Using the 20-foot FAV-20E (Fold-A-Vent) will eliminate most joints on the hip itself. (See main drawing below.) If 3 in 1 shingles are used, run a 3/8" bead of silicon caulking down each side of the slot, centered on the nailing surface of the vent. This will insure that the vent is sealed down across the shingle courses and prevent water from weeping in under the vent. If Heavy Weight Shingles, Shakes, Slate or Tiles are used: see Fig. C below for a detail on how to install a batten strip to provide a level surface for the vent to sit on. Batten strips need to be as thick as the thickest point of the roofing. There MUST NOT BE ANY GAPS UNDER THE VENT or water may leak in. 11" 5 1/2" 5 1/2" 1" ABA V-600E 11" 2" 2" 20 sq. in. NFVA/Lineal Foot 8 1/2" 4 1/4" 4 1/4" 1" ABA V-600E 8 1/2" 1 5/8" 1 5/8" 20 sq. in. NFVA/Lineal Foot 11" 5 1/2" 5 1/2" 5/8" ABA 2 1/2" 2 1/2" V-300E 11" & FAV-20E 11" 13.5 sq. in. NFVA/Lineal Foot 8 1/2" 4 1/4" 4 1/4" 5/8" ABA 1 7/8" 1 7/8" V-300E 8 1/2" & FAV-20E 8 1/2" 13.5 sq. in. NFVA/Lineal Foot 3 1/4" 5 1/8" 3/4" 1" 2 1/4" 2" ROOF-2-WALL VENT 8.5 sq. in. NFVA/Lineal Foot V-600TE 10 sq. in. NFVA/Lineal Foot 7" 3 1/2" 3 1/2" 5/8" ABA 2" 2" V-300E 7" 13.5 sq. in. NFVA/Lineal Foot COR-A-VENT RIDGE VENTS NON-ENHANCED END VIEWS TYPICAL 11" 5 1/2" 5 1/2" 1" ABA V-600 11" 2" 2" 20 sq. in. NFVA/Lineal Foot 8 1/2" 4 1/4" 4 1/4" 1" ABA V-600 8 1/2" 1 5/8" 1 5/8" 20 sq. in. NFVA/Lineal Foot 11" 5 1/2" 5 1/2" 5/8" ABA 2 1/2" 2 1/2" V-300 11" & FAV-20 11" 13.5 sq. in. NFVA/Lineal Foot 8 1/2" 4 1/4" 4 1/4" 5/8" ABA 1 7/8" 1 7/8" V-300 8 1/2" & FAV-20 8 1/2" 13.5 sq. in. NFVA/Lineal Foot 7" 3 1/2" 3 1/4" 3 1/2" 5/8" 1" ABA 2" 2" 2" V-300 7" & FAV-20 7" V-600T 13.5 sq. in. NFVA/Lineal Foot 10 sq. in. NFVA/Lineal Foot COR-A-VENT SPECIALTY APPLICATIONS 1" 1 1/2" 1" 1 1/2" 1" 3/4" S-400 STRIP VENT EAVE/SOFFIT PS-400 SOFFIT VENT RS-400 RAFT-A-VENT OPEN RAFTER VENT 10 sq. in. NFVA/Lineal Foot 10 sq. in. NFVA/Lineal Foot 18.7 sq. in. NFVA/22 1/2" Piece 7/16" 13/16" 3" Insect Screen 1" SV-3 SIDING VENT 3" 5 sq. in. NFVA/Lineal Foot 3" SV-5 SIDING VENT 9 sq. in. NFVA/Lineal Foot PURLIN VENT METAL ROOFING/SIDING 10 sq. in. NFVA/Lineal Foot 11" 1" IN-VENT 6.75" sq. in. NFVA/Lineal Foot 1 3/4" MINIMUM ROOF PITCH FOR INSTALLATION – 5/12 * A=5/16" * B=3/16" AWF=Active Weather Foil 1 /3 2" WITH ALL 7/8" OPENINGS AS NOTED 3" . MIN A 7/8" MIN. OP‘G V-600T Alternate Installation Examples: ® COR-A-VENT continually develops and improves applications to meet the growing demands of architecture and new roofing materials. The specialized details on this page have been proven in thousands of real world installations. We don’t experiment on your job. Roof-2-Wall Vent™ Roof to Wall Application Shingle Roof V-600T Metal Roof To Wall Application SIDING FLASHING V-600 11" – Architectural Metal Roof Application AIR DAM V-600 METAL SIDING FLASHING HALFB PIECE 1/2" HIGH DOME WIND CAP EXHAUST 3" AIR AIR DAM FLASHING B SHINGLES A V-600T RIDGE FELT IR BOARD TA EXHAUST PAPER AUS H AIR X E “Z” RAFTER RAFTER CL STANDING A OS SEAM UR ROOF E V-600 HALF PIECE SHINGLES FELT PAPER RIDGE BOARD RAFTER SHEATHING RAFTER TRUSS OR RAFTER V-600 RIDGE VENT WALL WALL W FLO AIR CEDAR SHAKES A SHEATHING FELT PAPER BEAD OF CAULKING A V-600 Half Piece Wide Ridge Application HIP RAFTER 1" AIR OPENING TYP. BLOCKING FASCIA S-400 STRIP VENT BLOCKING OW FL AIR TIO LA SU IN EXHAUST AIR N SHEATHING RAFTER 2x4 WALL WIDE RIDGE CAP P TRIM SHEATHING W FLO AIR JACK RAFTER 1" SLOT ALUM. DRIP EDGE CAP SHINGLES ROOF UNDERLAYMENT FELT PAPER 11 /4 BAMAX " T DIMTEN . 7/8" FLASHING SIDING V-600 HALF PIECE V-300 FLAT TILE W AIR FLO ROOF STARTER STRIP 5/8" - 7/8" GAP EXHAUST AIR TRUSS SHINGLESOR RAFTER SHEATHING EXHAUST AIR FELT PAPER TRUSS INS UL OR AT RAFTER IO N VINYL SIDING RAFTER OR TRUSS 12 15 2x6 RAFTER 2x4 WALL F AIR EXHAUST AIR ENHANCED SNOW SCREEN™ V-300 81/2" Flat Tile Application ENING REQUIRED ER VENTILATION V-300 81/2" FELT PAPER TILE CAP AIR AIR FLOW TRUSS AIR FLOW FOAM CLOSURE METAL FLASHING S-400 STRIP VENT V-600T RIDGE VENT AIR TRUSS OR RAFTER V-600T – W/Standing Seam Metal Roofing & High Wind Dome Cap HIGH WIND DOMECAP TYP. APPLICATION MINIMUM WIDTH SHOWN, CAN BE WIDER R V-600 11" – Architectural Metal Roof Application A 7/8" MIN. OP‘G V-600T A A 1 3/4" MIN. OP'G RE METAL ROOF WITH STANDING SEAM 1 3/4" MIN. OP'G. STANDING SEAM METAL ROOF 1" SLOT OW AIR FL H 1 3/4" A OT MIN. OP'G IR WALL CAULKING AIR DAM FLASHING DETAIL B 2 5/8" 51˚ S-400 Strip Vent – Wide Overhang Application ROOFING VE NT ILA TIO N ROOF SHEATHING CH U INSULATION TE EXHAUST AIR V-600TE RA FT ER ENHANCED SNOW SCREEN EXHAUST AIR HOT AIR RAFTER OR TRUSS FELT PAPER OW FL CL OS U 90˚ R AI “Z” FLASHINGA CL VARIABLE TO COMPLY WITH A FASTENERS, TYP. METAL SIDING INSULATION B IR TA AUS EXH Application 4" 3/ FASTENERS TYP. V-600TE Seam FINAL DOME DESIGN MUSTStanding COMPLY WITH ALL 7/8" OPENINGS AS NOTED Roof to Wall 1 LOW PROFILE CAP NOTE: IF CAP NEEDS TO BE WIDER, V-600 CAN BE SPLIT INTO HALF PIECES V-600 RIDGE VENT WALL SIDING TRUSS OR RAFTER 7/8" MIN. OP'G DRIP EDGE FASCIA BOARD " TILE ROOF E UT CH OW N FL TIO AIR TILA N VE INSULATION ER FT RA EXHAUST AIR SHEATHING FELT PAPER 1 3/4" MIN. OP'G FLOW HAUST AIR NOTE: NO VENT ON LOW SLOPE SIDE OF ROOF. WHEN ROOF PITCH IS LESS THAN 3/12. 2x6 RAFTER ROOF SHEATHING PROFILE PANEL METAL ROOFING BASE FLASHING OPENING REQUIRED A 7/8" MIN. FOR PROPER VENTILATION STANDING SEAM ROOF SHEATHING METAL ROOF A EXHAUST (1/2" TYP.) AIR METAL A CAP. FELTROOFING PAPER & WIDE RIDGE USE WHEN CAP IS OVER 12" FLAT TILE 2" ROOF 7/8" MIN. OP'G 2x6 RAFTER ROOFING 1/ 2 n V-600TE INSULA TION METAL ROOF CAP LOW V-600TE ROOF COVERING S-400 Strip Vent – Narrow Overhang Application V-600T – Profile Metal Roof Application HEAVY FELT PAPER OR WATERPROOF MEMBRANE 2 AIR FLO W EXHAUST AIR ENHANCED SNOW SCREEN™ SHEATHING 12 7 FL OW AIR 12 Roof-2-Wall ROOF COVERING EXHAUST AIR A FRIEZE A BOARD 2" 2 1/2"x1/2" SHIM FL OW V-600T CAP FLASHING IN SU L V-300 1" AIR REQUIRED OPENING A 7/8" MIN. OPENING FOR PROPER TYP.VENTILATION 81/2" COUNTER ROOF SHEATHING FLASHING (1/2" TYP.) FLASHING FELT PAPER 1" AIR OPENING CAULKING TYP. SHEATHING CAP ALUM. TILE CAP DRIP EDGE AIR FLOW 1" AIR VINYL SIDING W FLO AIR EXHAUST A 7/8" MIN. OPENING REQUIRED CAP TILE AIR B METAL AIR FOR PROPER VENTILATION DAM FLASHING DETAIL SHINGLES A SHEATHING RIDGE FELT SHEATHING BOARD V-600T PAPER A ROOF SHEATHING EXHAUST AIR RAFTER RAFTER 1/2" TYP. TILE FELT PAPER 1" MIN A ROOF OPG. TILE ROOF CEMENT MORTAR OPTIONAL 1" TRUSS 40˚ OR 1" 1/2"/FAV-E V-300E 8 Application – End View 4" 81/2" Hip RAFTER SLOT B METAL AIR DAM ication FLASHING DETAIL1 CEDAR RIDGE CAP V-300E 8 /2" PAT. NO. 5-339-582 WALL 0 81/2" BATTEN STRIP, TO BE 2" CAULKING DOUBLE THICKNESS 3" . 1/3 ENHANCED OF SHAKES AT HIP A MIN ST SNOW SCREEN™ U A XH CEDAR EXHAUST ROOF A SHAKES SHEATHING A FELT (1/2" TYPICAL) SHEATHING FELT PAPER 11 /4 7/8" PAPER BAMAX " TT DIM EN . V-600TE Standing JACK RAFTER Seam Application HEAVY FELT PAPER OR WATERPROOF MEMBRANE LOW PROFILE CAP FASTENERS, TYP. HIP RAFTER SHINGLES FELT PAPER Roof-2-Wall Unequal Pitch Application V-300 Clerestory Application V-600T Modern Shed Application V-300 81/2" Flat Tile Application (W/Air Dam Flashing Detail) AUST AIR AI R V-600T – "S" Tile Application HALF PIECE AT IO N V-600 0 11" DRIP EDGE FASCIA BOARD 7/8" MIN. OP'G STANDING SEAM METAL ROOFING WALL META COU FLA FLAS V-6 STAND METAL WALL S-400 Shed Roof Application AIR PATH BATTEN STRIP, TO BE DOUBLE THICKNESS OF SHAKES AT HIP A EXHAUST CAULKING ENHANCED SNOW SCREEN™ T AUS EXH ROOF SHEATHING (1/2" TYPICAL) TRUSS ation 1" SLOT CEDAR RIDGE CAP V-300E 81/2" V-300 81/2" FELT PAPER INSULATION S-400 Strip Vent – Wide Overhang Application S-400 Strip Vent – Narrow Overhang Application RECOMMENDED V-300E 81/2"/FAV-E 81/2" Hip Application – End View 2" MIN. V-300 81/2"/FAV 81/2" Ridge Application CEDAR RIDGE CAP EXHAUST AIR ENHANCED 1" MIN SNOW SCREEN™ OPG. SHINGLES FELT PAPER CAULKING SHEATHING RAFTER OR TRUSS W FLO AIR H 1 3/4" A OT MIN. OP'G IR Roof to Wall ROOF-2-WALL VENT MAXIMUM 1/2'' CAP SHINGLE OVERHANG FOR AWF TO CLOSE PROPERLY INSULATION OW AIR FL 7/8" MIN. OP'G A 7/8" MIN. OP'G AIR AIR 1" 1" EXHAUST AIR V-600 Standing Seam A FLASHING SHEATHING 11 /2" V-300 11" BEAD OF CAULKING CL WIDE RIDGE CAP RIDGE CAP 1" B Call our technical dept. for advice on your special application. Or, send OP'G. us a print and we’ll “mark up” where and how to vent it. Our Enhanced MIN.1 3/4" HOT AIR STANDING SEAM METAL products can be substituted whenever an extra measure ofROOF protection is needed. (Standard) CEDAR SHAKES FELT PAPER FA 1 3/4" MIN. OP'G V-600 Half Piece Wide Ridge Application V-300/V-600 Steep Pitch Application SHEATHING A A SOFFIT AIR SIDING S-400 STRIP VENT AIR CAULKIN FLOW RAFTER COR-A-VENT Folded End Cap Instructions: 2" V-600 13/4" V-300 1. Turn vent piece (V-300 shown) over so routed slot is facing up. Use utility knife to cut out a "V" shaped notch in one end of vent. 3. Fold end flap under and secure with a roofing nail – 2" for V-300 or 21/2" for V-600. This allows for the nail to penetrate an extra layer of vent material. 2. Measure 13/4" from end of vent and make a parallel cut through bottom 4. Nail vent pieces to roof per instructions above. Be sure to caulk between bottom edge of vent and roof at both ends of the ridge. 3 layers. For V-600, measure 2" from end and cut through bottom 5 layers. Remove loose pieces. Be careful not to cut off top layer!! Be careful not to touch knife blade. Always cut in a direction away from yourself. Wear proper hand and eye protection. For the best appearance, install COR-A-VENT continuously the entire length of the ridge. Figuring Your Ventilation Needs: V-600 = 20 Sq. inches NFVA/lineal foot. V-300 = 13.5 Sq. inches NFVA/lineal foot. USE BALANCED AMOUNTS OF SOFFIT VENT TO RIDGE VENT V-600: Square footage of building footprint X .48 = Lineal Feet V-600 needed 20 V-300: Square footage of building footprint X .48 = Lineal Feet V-300 needed 13.5 Example: 25' x 50' = 1250 Sq.F. 1250 x .48 = 600 600 ÷ 20 = 30 L.F. V-600 needed The above formulas will give the amount of COR-A-VENT ridge vent needed for a 1/150 vent ratio, provided an equal or greater amount of soffit venting is used. For a 1/300 ratio, (building code minimum) use half the amount of ridge vent. Note: Code interpretation may vary. Consult your local building dept. Balanced Ventilation is not only having an equal amount of ridge and soffit vents in net free inches, but having the soffit and ridge vents balance each other on the structure. Wherever there is ridge vent above, there should be soffit/eave/intake vents on the structure below. Important notes: COR-A-VENT ridge vents should always be installed with soffit/eave/intake vents of equal or greater area. All other vent openings (except soffits) should be closed off. The air passage way or “Ventilation Chute” between the inlet (soffit/eave/intake) and the outlet (ridge) vent must not be blocked or restricted. Call our technical service dept. for help with any standard or specialty ridge or soffit applications. Our website contains a complete listing of application details in .PDF and .DWG formats for viewing or downloading. “This material may be duplicated only for the purposes of specifying COR-A-VENT® products. No permission is given to duplicate or otherwise copy this material for any other purpose without the express written permission of COR-A-VENT, Inc.” ©2006 COR-A-VENT, Inc. 04/14 4-Page Installation Instructions
© Copyright 2026 Paperzz