Sylodyn NB Material Data Sheet ® Material Colour closed cellular polyurethane red Standard Sylodyn® range Standard dimensions on stock Thickness: 12.5 mm with Sylodyn® NB 12 25 mm with Sylodyn® NB 25 Rolls: 1.5 m wide, 5.0 m long Stripes: max. 1.5 m wide, up to 5.0 m long NF NE Other dimensions (also thickness) as well as stamped and molded parts on request. Area of application Static load limit ND Compression load Delection NC (depending on form factor) 2 up to 0.075 N/mm ** approx. 7 %** 2 Operating load range (static plus dynamic loads) up to 0.120 N/mm ** approx. 15 %** Load peaks (short term, infrequent loads) up to 2.0 N/mm2** approx. 70 %** NB 10 Test methods Comment 0.75 N/mm2 DIN EN ISO 527-3/5/100* minimum value 450 % DIN EN ISO 527-3/5/100* minimum value DIN 53515* minimum value Material properties Tensile stress at break Elongation at break Tear strength Abrasion 1 3.0 N/mm 3 0.1 0.01 0.001 Static load limit [N/mm2] DIN 53516 load 5 N, bottom surface 0.7 Getzner Werkstoffe dry 0.7 Getzner Werkstoffe dry EN ISO 1856 50 %, 23 °C, 70 h, 30 minutes after unloading Static shear modulus 2 0.13 N/mm DIN ISO 1827* at static load limit Dynamic shear modulus 0.18 N/mm2 DIN ISO 1827* at static load limit Coeficient of friction (steel) Coeficient of friction (concrete) Compression set 1,400 mm <5% Mechanical loss factor 0.07 DIN 53513* depending on frequency, load and amplitude (reference value) Rebound elasticity 70 % DIN 53573 tolerance +/- 10 % Operating temperature Flammability Speciic volume resistance Thermal conductivity Further characteristic values on request * Tests according to respective standards ** At form factor q=3 short term higher temperatures possible -30 to 70 °C DIN 4102 EN ISO 11925-2 normal lammable EN 13501-1 > 101 Ω·cm DIN IEC 93 dry 0.06 W/[m·K] DIN 52612/1 B2 class E All information and data is based on our current knowledge. The data can be applied for calculations and as guidelines, are subject to typical manufacturing tolerances, and are not guaranteed. We reserve the right to amend the data. Further information can be found in VDI Guidline 2062 – Page 2. www.getzner.com 1 Sylodyn ® NB Load delection curve Form factor: q=6 0.15 12.5 mm 25 mm 37.5 mm 50 mm Operating load range Speciic load [N/mm2] Full surface bearing 0.10 Static load limit 0.05 0 0 2 3 4 5 6 7 8 9 10 11 12 Delection [mm] Form factor: q=3 0.15 12.5 mm 25 mm 37.5 mm 50 mm Operating load range Speciic load [N/mm2] Strip bearing 1 0.10 Static load limit 0.05 0 0 2 3 4 5 6 7 8 9 10 11 12 Delection [mm] Form factor: q=1.5 0.15 12.5 mm 25 mm 37.5 mm 50 mm Operating load range Speciic load [N/mm2] Point bearing 1 0.10 Static load limit 0.05 0 0 www.getzner.com 1 2 3 4 5 6 7 8 9 10 11 12 Delection [mm] Quasi-static load delection curve measured at a velocity of deformation of 1 % of the thickness per second; testing between lat steel-plates; recording of the 3rd loading; testing at room temperature 2 Natural frequency Form factor: q=6 Form factor: q=6 1.4 Speciic load [N/mm2] E-modulus [N/mm2] Modulus of elasticity 1.2 1.0 0.8 0.15 0.10 30 Hz 50 mm 0.6 10 Hz 0.05 0.4 37.5 mm Static 25 mm 0.2 0 0.10 0 0.15 Speciic load [N/mm2] 0 5 10 Form factor: q=3 Form factor: q=3 Speciic load [N/mm2] 0.05 E-modulus [N/mm2] 0 1.4 1.2 1.0 0.8 12.5 mm 15 20 25 Natural frequency [Hz] 15 20 25 Natural frequency [Hz] 15 20 25 Natural frequency [Hz] 0.15 0.10 30 Hz 0.6 10 Hz 0.4 Static 50 mm 0.05 37.5 mm 25 mm 0.2 0 0 0.05 0.10 Form factor: q=1.5 0 5 10 Form factor: q=1.5 1.4 Speciic load [N/mm2] E-modulus [N/mm2] 0 0.15 Speciic load [N/mm2] 12.5 mm 1.2 1.0 0.15 0.10 0.8 30 Hz 0.6 50 mm 10 Hz 0.05 0.4 37.5 mm Static 0.2 0 25 mm 0 0.05 0.10 0.15 Speciic load [N/mm2] Static modulus of elasticity as a tangent modulus taken from the load delection curve; dynamic modulus of elasticity due to sinusoidal excitation with a velocity level of 100 dBv re. 5·10-8 m/s; test according to DIN 53513 0 0 5 12.5 mm 10 Natural frequency of a single-degree-of-freedom system (SDOF system) consisting of a ixed mass and an elastic bearing consisting of Sylodyn® NB based on a stiff subgrade; parameter: thickness of elastomeric bearing 3 Disturbing frequency [Hz] Vibration isolation – eficiency 200 -40 dB/99 % 180 -30 dB/97 % 160 140 -20 dB/90 % 120 100 80 Reduction of the transmitted mechanical vibrations by implementation of an elastic bearing consisting of Sylodyn® NB Parameter: factor of transmission in dB, isolation rate in % -10 dB/69 % 60 -0 dB/0 % 40 20 0 5 10 15 20 25 30 35 50 40 45 Natural frequency [Hz] Relative deflection [% of thickness with unstressed sample] Creep behaviour 18 Increase in deformation under consistent loading Parameter: permanent loading Form factor: q=3 16 14 100 % load 12 10 8 6 50 % load 4 2 1d 1m 1a 10 a 0 0.1 1 10 100 1,000 10,000 100,000 1,000,000 Period of loading [h] Dyn. E-modulus [N/mm2] Dynamic E-modulus at long term loading 1.4 1.2 100,000 h 1,000 h 1.0 10 h 0.8 Change of dynamic modulus of elasticity under consistent loading (at 10 Hz) Parameter: load duration Form factor: q=3 0.1 h 0.6 0.4 0.2 0 0 0.05 0.10 0.15 0.20 Permanent loading [N/mm2] www.getzner.com 4 Mechanical loss factor Dyn. E-modulus [N/mm2] Temperature dependency 2.0 1.5 DMA-test (Dynamic Mechanical Analysis); tests within linear area of the load delection curve, at low speciic loads 0.4 0.3 30 Hz 1.0 0.5 10 Hz 0.2 30 Hz 0.5 0.1 0 -10 0 10 20 30 0 40 50 Temperature [°C] 10 Hz -10 0 10 20 30 40 50 Temperature [°C] Mechanical loss factor Dyn. E-modulus [N/mm2] Frequency dependency 2.0 1.5 DMA-tests; mastercurve with a reference-temperature of 21 °C; tests within the linear area of the load delection curve, at low speciic loads 0.3 1.0 0.2 0.5 0.1 0 0 1 10 100 1,000 Frequency [Hz] Speciic load [N/mm2] 1.4 1.2 30 Hz 1.0 1 10 100 1,000 Frequency [Hz] Dependency on loading velocity Dependency on amplitude Dyn. E-modulus [N/mm2] 0.4 0.20 0.75 N/mm2/s 0.0075 N/mm2/s Dependency on loading velocity: Form factor: q=3, thickness of material 25 mm 0.15 0.075 N/mm2/s 10 Hz 0.8 Dependency on amplitude: preload at static load limit; Form factor: q=3, thickness of material 25 mm 0.10 0.6 0.4 0.05 0.2 0 0.01 0.10 1.00 Amplitude [mm] 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Delection [mm] www.getzner.com 5 Form factor The form factor is a geometric measure for the shape of an elastomeric bearing deined as the ratio of the loaded area and the area of sum of the perimeter surfaces. Deinition: Form factor = Loaded area Loaded area Perimeter surface area Perimeter surface area I·w 2·t·(I+w) For a rectangular shape: q = (l..length, w..width, t..thickness) Perimeter surface area The form factor has an inluence on the delection and the static load limit respectively. Elastic Sylodyn®-bearings are considered as Full surface bearing: Form factor > 6 Strip bearing: Form factor between 2 and 6 Point bearing: Form factor < 2 Inluence of the form factor on the static load limit for a homogeneous material Reference value: Form factor q=3 40 % 30 % Increase of delection 20 % 0.080 0.075 Increase of static load limit 0.070 10 % Decrease of static load limit 0% Decrease of delection 0.065 -10 % -20 % 0 0.060 1 2 3 4 5 6 Form factor AUSTRIA — Bürs GERMANY — Berlin — Munich FRANCE — Lyon INDIA — Pune CHINA — Beijing USA — Charlotte 0 1 2 3 4 5 6 Form factor DB SN NB en © Copyright by Getzner Werkstoffe GmbH l 09-2014 We reserve the right to amend the data. Static load limit [N/mm2] Deviation of delection [%] Inluence of the form factor on the delection at the static load limit for a homogeneous material Reference value: Form factor q=3 JORDAN — Amman JAPAN — Tokyo www.getzner.com 6
© Copyright 2026 Paperzz