CP Stent™ For Coarctation of the Aorta Featured here: Covered CP Stent™ CP Stent™ 0.013” Platinum/ Iridium Wire Balloon in Balloon Catheter allows for incremental inflation Inner Balloon acts as a tool to hold the stent in place while outer balloon is inflated “Zig” Pattern Stent Design Expands to diameters ranging from 12mm to 24mm Laser welded at each joint, over brazed with 24k Gold Covered CP Stent™ Stand Alone or Pre-Mounted on a BIB® Catheter Ordering Information: Mounted Covered CP Stent™ Outer Balloon Diameter (mm) Outer Balloon Length (cm) Outer Rated Burst (ATM) Inner Balloon Diameter (mm) Inner Balloon Length (cm) Inner Rated Burst (ATM) Profile (F) Stent Length (cm) 12 12 12 14 14 14 14 16 16 16 16 16 18 18 18 18 20 20 20 22 24 24 3 3.5 4 2.5 3.5 4 4.5 2.5 3 3.5 4 4.5 3 3.5 4 4.5 3 4 4.5 4 4 5 7 7 7 6 6 6 6 5 5 5 5 5 4 4 4 4 4 4 4 3 3 3 6 6 6 7 7 7 7 8 8 8 8 8 9 9 9 9 10 10 10 11 12 12 2 2.5 3 1.5 2.5 3 3.5 1.5 2 2.5 3 3.5 2 2.5 3 3.5 2 3 3.5 3 3 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 4.5 4.5 4.5 12 12 12 12 12 12 12 12 12 12 12 12 14 14 14 14 14 14 14 14 14 14 2.8 3.4 3.9 1.6 3.4 3.9 4.5 2.2 2.8 3.4 3.9 4.5 2.8 3.4 3.9 4.5 2.8 3.9 4.5 3.9 3.9 4.5 All Catheters have a usable length of 110 cm and for use with a 0.035” guidewire. Foreshortening chart information available on our website www.bisusa.org Reference Number Model Number 614387 CMCP038 614384 CMCP035 614385 CMCP036 614457 CMCP002 614361 CMCP012 614366 CMCP017 614372 CMCP023 614355 CMCP006 614358 CMCP009 614362 CMCP013 614367 CMCP018 614373 CMCP024 614359 CMCP010 614363 CMCP014 614368 CMCP019 614374 CMCP025 614360 CMCP011 614369 CMCP020 614375 CMCP026 614370 CMCP021 614371 CMCP022 614383 CMCP034 Unmounted CP Stent™ Stent Length (cm) Covered CP Stent™ CP Stent™ Reference Number Model Number Reference Number Model Number 1.6 614300 CP8Z16 614306 CVRDCP8Z16 2.2 614301 CP8Z22 614307 CVRDCP8Z22 2.8 614302 CP8Z28 614308 CVRDCP8Z28 3.4 614303 CP8Z34 614309 CVRDCP8Z34 3.9 614304 CP8Z39 614310 CVRDCP8Z39 4.5 614305 CP8Z45 614311 CVRDCP8Z45 Required Introducer Sizes BIB® Delivery Catheter Balloon Diameter Required Introducer with CP Stent™ Required Introducer with Covered CP Stent™ 12 mm 10F 12F 14mm 10F 12F 15mm 11F 12F 16mm 11F 12F 18mm 11F 14F 20mm 12F 14F 22mm 12F 14F 24mm 12F 14F For more information or to place an order, contact your B. Braun Interventional Systems Inc. representative or call 1-877-836-2228 INDICATIONS FOR USE: The CP Stent™ and Mounted CP Stent™ are indicated for use in the treatment of native and/or recurrent coarctation of the aorta involving a compliant aortic isthmus or first segment of the descending aorta where there is adequate size and patency of at least one femoral artery and balloon angioplasty is contraindicated or predicted to be ineffective. The Covered CP Stent™ and Covered Mounted CP Stent™ are indicated for use in the treatment of native and/or recurrent coarctation of the aorta involving the aortic isthmus or first segment of the descending aorta where there is adequate size and patency of at least one femoral artery associated with one or more of the following: • Acute or chronic aortic wall injury • Nearly atretic descending aorta of 3 mm or less in diameter • A non-compliant stenotic aortic segment found on pre-stent balloon dilation • A genetic or congenital syndrome associated with aortic wall weakening or ascending aortic aneurysm. Refer to the Instructions for Use for complete indications, relevant warnings, precautions, complications, and contraindications. Manufactured by NuMED, Inc. Distributed by B. Braun Interventional Systems Inc. Rx only CV2040 4/16 CP Stent™ is a trademark of NuMED, Inc. BIB® Catheter is a registered trademark of NuMED, Inc. ©2016 B. Braun Interventional Systems Inc. Distributed by: B. Braun Interventional Systems Inc. 824 Twelfth Avenue Bethlehem, PA 18018 USA Tel: 1-877-836-2228 Fax: 1-610-849-1334 www.bisusa.org
© Copyright 2026 Paperzz