3-113 "GIVEN" k_spoon=8.7 "[Btu/h-ft-F], parameter to be varied" T_w=200 "[F]" T_infinity=75 "[F]" A_c=0.08/12*0.5/12 "[ft^2]" "L=7 [in], parameter to be varied" h=3 "[Btu/h-ft^2-F]" "ANALYSIS" p=2*(0.08/12+0.5/12) a=sqrt((h*p)/(k_spoon*A_c)) (T_tip-T_infinity)/(T_w-T_infinity)=cosh(a*(L-x)*Convert(in, ft))/cosh(a*L*Convert(in, ft)) x=L "for tip temperature" DELTAT=T_w-T_tip kspoon [Btu/h.ft.F] 5 16.58 28.16 39.74 51.32 62.89 74.47 86.05 97.63 109.2 120.8 132.4 143.9 155.5 167.1 178.7 190.3 201.8 213.4 225 ∆T [F] 124.9 122.6 117.8 112.5 107.1 102 97.21 92.78 88.69 84.91 81.42 78.19 75.19 72.41 69.82 67.4 65.14 63.02 61.04 59.17 kspoon [Btu/h.ft.F] 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 ∆T [F] 122.4 123.4 124 124.3 124.6 124.7 124.8 124.9 124.9 125 125 125 125 125 12 125 130 120 110 100 ∆ T [F] 90 80 70 60 50 0 45 90 135 180 k spoon [Btu/h-ft-F] 125.5 125 124.5 ∆ T [F] 124 123.5 123 122.5 122 5 6 7 8 9 L [in] 10 11 12 225