,QWHUORFNLQJIRU&% GLDPHWHU %+B 1MRK 580 161-BEN Page 1 Revision: Issued: November 2002 Data subject to change without notice )HDWXUHV $SSOLFDWLRQ • Interlocking function available for a breaker-and-a-half diameter • Easy to adapt to customer’s specific requirements • Preconfigured and tested interlocking function block • Distributed solution, no central function The interlocking function blocks the possibility to operate high voltage switching devices, for instance when a disconnector is under load, in order to prevent material damage and/or accidental human injury. control terminals communicate via the system-wide interbay bus or by using hardwired binary inputs/outputs. The interlocking conditions depend on the circuit configuration and status of the installation at any given time. Each control terminal has interlocking functions for different switchyard arrangements, each handling interlocking of one bay. The function is distributed to each control terminal and not dependent on any central function. For the station-wide interlocking, the The interlocking modules BH_LINE_A, BH_CONN and BH_LINE_B are used for lines connected to a breaker-and-a-half diameter according to figure 1. A (BB1) B (BB2) Q1 Q2 Q51 Q51 Q0 Q0 Q52 BH_LINE_A Q52 Q6 Q6 Q53 Q53 Q61 Q0 Q51 Q9 BH_LINE_B Q62 Q52 Q9 Q8 Q8 BH_CONN 99000360.vsd Figure 1: Switchyard layout breaker-and-a-half ,QWHUORFNLQJIRU&%GLDPHWHU %+B 1MRK 580 161-BEN Page 2 'HVLJQ For easy and safe implementation of the interlocking function, the control terminal is delivered with standardized and tested software interlocking modules containing logic for the interlocking conditions. The interlocking conditions can be altered, to meet the customer’s specific requirements, by adding configurable logic by means of the graphical configuration tool CAP 531. The input signals EXDU_xxx shall be set to true if there is no transmission error at transfer of information from another bay. The signal is generated from the data valid output in the command function block, that receives the transferred information. The inputs QxEXy are used for delivery specific conditions to be added to the standard modules if required. Required signals with designations ended with TR are intended to be transferred to other bays. Two types of interlocking modules per diameter are defined. BH_LINE_A/B is the connection from one line to the busbar and is used twice per diameter. BH_CONN is the connection between the two lines of the diameter. The figure “Switchyard layout breaker-and-a-half” shows the designations of the apparatuses that can be dealt with by these modules. The input signals EXVVA_xx are always set to true, because the interlocking software is always running in our applications. )XQFWLRQEORFN IL01- IK01- %+B/,1(B$ %+B&211 Q0_OP Q0CLREL Q0_CL Q0CLITL Q6_OP Q6REL Q6_CL Q6ITL Q1_OP Q1REL Q1_CL Q1ITL Q51_OP Q51REL Q51_CL Q51ITL Q52_OP Q52REL Q52_CL Q52ITL Q53_OP Q53REL Q53_CL Q53ITL Q9_OP Q9REL Q9_CL Q9ITL Q8_OP Q8REL Q8_CL Q8ITL CQ0_OP Q1OPTR CQ0_CL Q1CLTR CQ61_OP VPQ1TR CQ61_CL CQ51_OP CQ51_CL CQ52_OP CQ52_CL Q15_OP Q15_CL VOLT_OP VOLT_CL EXDUP_ES EXVVA_ES Q6EX1 Q6EX2 Q1EX1 Q1EX2 Q9EX1 Q9EX2 Q9EX3 Q9EX4 Q9EX5 Q9EX6 Q9EX7 Q0_OP Q0CLREL Q0_CL Q0CLITL Q61_OP Q61REL Q61_CL Q61ITL Q62_OP Q62REL Q62_CL Q62ITL Q51_OP Q51REL Q51_CL Q51ITL Q52_OP Q52REL Q52_CL Q52ITL 1Q53_OP 1Q53_CL 2Q53_OP 2Q53_CL Q61EX1 Q61EX2 Q62EX1 Q62EX2 xx00000370.vsd xx00000371.vsd ,QWHUORFNLQJIRU&%GLDPHWHU %+B 1MRK 580 161-BEN Page 3 IM01- %+B/,1(B% Q0_OP Q0CLREL Q0_CL Q0CLITL Q6_OP Q6REL Q6_CL Q6ITL Q2_OP Q2REL Q2_CL Q2ITL Q51_OP Q51REL Q51_CL Q51ITL Q52_OP Q52REL Q52_CL Q52ITL Q53_OP Q53REL Q53_CL Q53ITL Q9_OP Q9REL Q9_CL Q9ITL Q8_OP Q8REL Q8_CL Q8ITL CQ0_OP Q2OPTR CQ0_CL Q2CLTR CQ62_OP VPQ2TR CQ62_CL CQ51_OP CQ51_CL CQ52_OP CQ52_CL Q25_OP Q25_CL VOLT_OP VOLT_CL EXDUP_ES EXVVA_ES Q6EX1 Q6EX2 Q2EX1 Q2EX2 Q9EX1 Q9EX2 Q9EX3 Q9EX4 Q9EX5 Q9EX6 Q9EX7 xx00000372.vsd ,QSXWDQG RXWSXWVLJQDOV 7DEOH ,QSXWVLJQDOVIRUWKH%+B/,1(B$,/QQIXQFWLRQEORFN 6LJQDO 'HVFULSWLRQ Q0_OP Signal is 1 if Q0 is open Q0_CL Signal is 1 if Q0 is closed Q6_OP Signal is 1 if Q6 is open Q6_CL Signal is 1 if Q6 is closed Q1_OP Signal is 1 if Q1 is open Q1_CL Signal is 1 if Q1 is closed Q51_OP Signal is 1 if Q51 is open Q51_CL Signal is 1 if Q51 is closed Q52_OP Signal is 1 if Q52 is open Q52_CL Signal is 1 if Q52 is closed Q53_OP Signal is 1 if Q53 is open Q53_CL Signal is 1 if Q53 is closed Q9_OP Signal is 1 if Q9 is open Q9_CL Signal is 1 if Q9 is closed Q8_OP Signal is 1 if Q8 is open Q8_CL Signal is 1 if Q8 is closed ,QWHUORFNLQJIRU&%GLDPHWHU %+B 1MRK 580 161-BEN Page 4 6LJQDO 'HVFULSWLRQ CQ0_OP Signal is 1 if Q0 in module BH_CONN is open CQ0_CL Signal is 1 if Q0 in module BH_CONN is closed CQ61_OP Signal is 1 if Q61 in module BH_CONN is open CQ61_CL Signal is 1 if Q61 in module BH_CONN is closed CQ51_OP Signal is 1 if Q51 in module BH_CONN is open CQ51_CL Signal is 1 if Q51 in module BH_CONN is closed CQ52_OP Signal is 1 if Q52 in module BH_CONN is open CQ52_CL Signal is 1 if Q52 in module BH_CONN is closed Q15_OP Signal is 1 if earthing switch Q15 on busbar A is open Q15_CL Signal is 1 if earthing switch Q15 on busbar A is closed VOLT_OP There is no voltage on the line and not fuse failure VOLT_CL There is voltage on the line or there is a VT (fuse) failure EXDUP_ES Signal is 1 if there is no transmission error from any bay containing earthing switches Q15 EXVVA_ES Signal is 1 if the interlocking programs in all bays containing earthing switches Q15 are running Q6EX1 Input for an external condition for apparatus Q6 Q6EX2 Input for an external condition for apparatus Q6 Q1EX1 Input for an external condition for apparatus Q1 Q1EX2 Input for an external condition for apparatus Q1 Q9EX1 Input for an external condition for apparatus Q9 Q9EX2 Input for an external condition for apparatus Q9 Q9EX3 Input for an external condition for apparatus Q9 Q9EX4 Input for an external condition for apparatus Q9 Q9EX5 Input for an external condition for apparatus Q9 Q9EX6 Input for an external condition for apparatus Q9 Q9EX7 Input for an external condition for apparatus Q9 7DEOH 2XWSXWVLJQDOVIRUWKH%+B/,1(B$,/QQIXQFWLRQEORFN 6LJQDO 'HVFULSWLRQ Q0CLREL Closing of Q0 is allowed Q0CLITL Closing of Q0 is forbidden Q6REL Switching of Q6 is allowed Q6ITL Switching of Q6 is forbidden Q1REL Switching of Q1 is allowed Q1ITL Switching of Q1 is forbidden Q51REL Switching of Q51 is allowed Q51ITL Switching of Q51 is forbidden Q52REL Switching of Q52 is allowed Q52ITL Switching of Q52 is forbidden Q53REL Switching of Q53 is allowed Q53ITL Switching of Q53 is forbidden Q9REL Switching of Q9 is allowed ,QWHUORFNLQJIRU&%GLDPHWHU %+B 1MRK 580 161-BEN Page 5 6LJQDO 'HVFULSWLRQ Q9ITL Switching of Q9 is forbidden Q8REL Switching of Q8 is allowed Q8ITL Switching of Q8 is forbidden Q1OPTR Signal is 1 if Q1 is open Q1CLTR Signal is 1 if Q1 is closed VPQ1TR Switch status of Q1 is valid (open or closed) 7DEOH ,QSXWVLJQDOVIRUWKH%+B&211,.QQIXQFWLRQEORFN 6LJQDO 'HVFULSWLRQ Q0_OP Signal is 1 if Q0 is open Q0_CL Signal is 1 if Q0 is closed Q61_OP Signal is 1 if Q61 is open Q61_CL Signal is 1 if Q61 is closed Q62_OP Signal is 1 if Q62 is open Q62_CL Signal is 1 if Q62 is closed Q51_OP Signal is 1 if Q51 is open Q51_CL Signal is 1 if Q51 is closed Q52_OP Signal is 1 if Q52 is open Q52_CL Signal is 1 if Q52 is closed 1Q53_OP Signal is 1 if Q53 on line 1 is open 1Q53_CL Signal is 1 if Q53 on line 1 is closed 2Q53_OP Signal is 1 if Q53 on line 2 is open 2Q53_CL Signal is 1 if Q53 on line 2 is closed Q61EX1 Input for an external condition for apparatus Q61 Q61EX2 Input for an external condition for apparatus Q61 Q62EX1 Input for an external condition for apparatus Q62 Q62EX2 Input for an external condition for apparatus Q62 7DEOH 2XWSXWVLJQDOVIRUWKH%+B&211,.QQIXQFWLRQEORFN 6LJQDO 'HVFULSWLRQ Q0CLITL Closing of Q0 is forbidden Q0CLREL Closing of Q0 is allowed Q51ITL Switching of Q51 is forbidden Q51REL Switching of Q51 is allowed Q52ITL Switching of Q52 is forbidden Q52REL Switching of Q52 is allowed Q61ITL Switching of Q61 is forbidden Q61REL Switching of Q61 is allowed Q62ITL Switching of Q62 is forbidden Q62REL Switching of Q62 is allowed ,QWHUORFNLQJIRU&%GLDPHWHU %+B 1MRK 580 161-BEN Page 6 7DEOH ,QSXWVLJQDOVIRUWKH%+B/,1(B%,0QQIXQFWLRQEORFN 6LJQDO 'HVFULSWLRQ Q0_OP Signal is 1 if Q0 is open Q0_CL Signal is 1 if Q0 is closed Q6_OP Signal is 1 if Q6 is open Q6_CL Signal is 1 if Q6 is closed Q2_OP Signal is 1 if Q2 is open Q2_CL Signal is 1 if Q2 is closed Q51_OP Signal is 1 if Q51 is open Q51_CL Signal is 1 if Q51 is closed Q52_OP Signal is 1 if Q52 is open Q52_CL Signal is 1 if Q52 is closed Q53_OP Signal is 1 if Q53 is open Q53_CL Signal is 1 if Q53 is closed Q9_OP Signal is 1 if Q9 is open Q9_CL Signal is 1 if Q9 is closed Q8_OP Signal is 1 if Q8 is open Q8_CL Signal is 1 if Q8 is closed CQ0_OP Signal is 1 if Q0 in module BH_CONN is open CQ0_CL Signal is 1 if Q0 in module BH_CONN is closed CQ62_OP Signal is 1 if Q62 in module BH_CONN is open CQ62_CL Signal is 1 if Q62 in module BH_CONN is closed CQ51_OP Signal is 1 if Q51 in module BH_CONN is open CQ51_CL Signal is 1 if Q51 in module BH_CONN is closed CQ52_OP Signal is 1 if Q52 in module BH_CONN is open CQ52_CL Signal is 1 if Q52 in module BH_CONN is closed Q25_OP Signal is 1 if earthing switch Q25 on busbar B is open Q25_CL Signal is 1 if earthing switch Q25 on busbar B is closed VOLT_OP There is no voltage on the line and not fuse failure VOLT_CL There is voltage on the line or there is a VT (fuse) failure EXDUP_ES Signal is 1 if there is no transmission error from any bay containing earthing switches Q25 EXVVA_ES Signal is 1 if the interlocking programs in all bays containing earthing switches Q25 are running Q6EX1 Input for an external condition for apparatus Q6 Q6EX2 Input for an external condition for apparatus Q6 Q2EX1 Input for an external condition for apparatus Q2 Q2EX2 Input for an external condition for apparatus Q2 Q9EX1 Input for an external condition for apparatus Q9 Q9EX2 Input for an external condition for apparatus Q9 Q9EX3 Input for an external condition for apparatus Q9 Q9EX4 Input for an external condition for apparatus Q9 ,QWHUORFNLQJIRU&%GLDPHWHU %+B 1MRK 580 161-BEN Page 7 6LJQDO 'HVFULSWLRQ Q9EX5 Input for an external condition for apparatus Q9 Q9EX6 Input for an external condition for apparatus Q9 Q9EX7 Input for an external condition for apparatus Q9 7DEOH 0DQXIDFWXUHU 2XWSXWVLJQDOVIRUWKH%+B/,1(B%,0QQIXQFWLRQEORFN 6LJQDO 'HVFULSWLRQ Q0CLREL Closing of Q0 is allowed Q0CLITL Closing of Q0 is forbidden Q6REL Switching of Q6 is allowed Q6ITL Switching of Q6 is forbidden Q2REL Switching of Q2 is allowed Q2ITL Switching of Q2 is forbidden Q51REL Switching of Q51 is allowed Q51ITL Switching of Q51 is forbidden Q52REL Switching of Q52 is allowed Q52ITL Switching of Q52 is forbidden Q53REL Switching of Q53 is allowed Q53ITL Switching of Q53 is forbidden Q9REL Switching of Q9 is allowed Q9ITL Switching of Q9 is forbidden Q8REL Switching of Q8 is allowed Q8ITL Switching of Q8 is forbidden Q2OPTR Signal is 1 if Q2 is open Q2CLTR Signal is 1 if Q2 is closed VPQ2TR Switch status of Q2 is valid (open or closed) $%%$XWRPDWLRQ7HFKQRORJ\3URGXFWV$% Control & Force Measurement Substation Automation SE-721 59 Västerås Sweden Tel: +46 (0) 21 34 20 00 Fax: +46 (0) 21 14 69 18
© Copyright 2026 Paperzz