Powell Valve Closure Systems for plug

Powell Valve Closure Systems for plug-type
angle valves or ball-type angle valves
Valve Closure Systems from Powell Fabrication & Manufacturing, Inc. represent today’s best available
technology to prevent catastrophic releases from small, pressurized containers.
Powell Valve Closure Systems can be configured to automatically close the valve within seconds of the
detection of a leak, security breach, fire alarm, seismic event, or other circumstance. Alternatively, the
systems can be activated manually from the main control panel or from remote-mounted emergency stop
panels located inside or outside the room.
The UniPro™ Pneumatic Actuator is manufactured using the finest stainless and carbon steels as well as
aircraft quality aluminum. It is the responsibility of the owner/operator to understand what effect the fluids,
that they service, may have on these materials. Damage due to corrosion or oxidation initiated by these fluids
is not covered by the warranty.
UniPro™ Pneumatic Valve Closure System
The UniPro™ Valve Closure System is the only system on
the market with the flexibility to accommodate dome sizes
ranging from 20-ton bullet tanks to 90-ton railcars, along with
the versatility to close virtually any plug-type or ball-type angle
valve. It is designed to stand alone as a complete system or
to integrate or interface with unloading system components
that may already be in place at the site. The basic system
incorporates several components, each of which has been
engineered, designed, and pre-assembled by Powell to ensure
proper system performance and reduced installation time, labor
and material cost.
Budgetary Pricing for Typical System
We will need information about your company and the prospective application in order to provide budgetary
pricing for a Powell Valve Closure System. Please review the “Factors to Define Equipment Needs” on the
next pages. Please provide the information as completely as possible in order that we may provide budgetary
pricing for equipment that is appropriate for your needs. The completed form may be returned to Powell by
email at [email protected], or by fax to 989.681.5013.
*Patent Pending, Powell Fabrication & Manufacturing Inc.
Powell
Fabrication & Manufacturing, Inc.
Factors to Define Equipment Needs
1. Information About Company Requesting Pricing
If you are an agent requesting information about Powell equipment on behalf of another company, please
provide the information requested below about your company.
Contact Person:
Company Name:
Subsidiary of:
Address:
City:
State: Zip:
Phone:
Fax:
e-mail: Website:
Country:
2. Information About End User of Powell Equipment
Please provide the information requested below about the company that will be the end user of the Powell
equipment.
Company Name:
Subsidiary of:
Address:
City:
State: Zip:
Phone:
Fax:
e-mail: Website:
Country:
Number of years under company name listed above:
Other names company does business under:
Number of years at location listed above:
Incorporated in the Country of:
Type of product/products manufactured or sold:
Name of product/products manufactured or sold:
Country in which equipment will be located:
Port equipment will be shipped to:
Powell
Fabrication & Manufacturing, Inc.
3.
System Requirements
3.2 Chemical Handling
Powell Valve Closure Systems are designed for use with various chemicals.
What product is being loaded/unloaded?
Is it flammable?
Yes
No
How many loading/unloading stations do you have?
How many will be in service at the same time?
How are the railcars oriented relative to each other?
Will you require remote emergency stop panels?
How many?
Yes
No
3.3 Valve Information
What make, model, and size of valves are in use on the containers you’ll be servicing?
Make:
Model:
Size:
How many spokes/holes do the hand wheels on the valves have?
Can the valves be operated and properly seated by hand or are tools required (T-bar or spanner) to do so?
How many valves are open on each railcar in service?
Are the angle valves located within a dome or bonnet?
Yes
No
If so, what is the height, diameter and thickness of the dome wall?
Height:
Diameter:
Thickness:
Are all the domes the same?
Yes
No
When the valves are open, how far below the top rim of the dome are the tops of the hand wheels?
Is there dry air (-40° dew point) or nitrogen available at the stations?
Yes
No
Will the valve closure system be installed in an electrically classified hazardous location?
Yes
No
If you are servicing railcars, please supply a sketch of the dockside plumbing of the chlorine lines from the
railcar angle valves to the dock valves.
Powell
Fabrication & Manufacturing, Inc.
740 East Monroe Road
St. Louis MI 48880
Phone: 888.800.2310 (Toll Free)
989.681.2158 (Local)
Fax: 989.681.5013
email: [email protected]
website: www.powellfab.com
www.valveclosures.com
9300.12312009
I:\Intranet\Marketing\SalesLit\PrintPDF’s\ValveClosure\UniPro
© 2010, Powell Fabrication & Manufacturing, Inc. All rights reserved.