Eyefinity EHR Equipment Integration by Company

Eyefinity EHR Equipment Integration
by Company
The following table lists the instruments that currently integrate with Eyefinity EHR.
NOTES
• Currently, the Eyefinity EHR equipment interface requires a
Windows-based workstation. The equipment interface does not
currently work directly with the Eyefinity EHR iPad app or
non-Windows computers.
• Computers that are attached to diagnostic equipment must meet
the OfficeMate system requirements.To review the requirements,
go to
http://www.eyefinity.com/practice-management/officemate/sys-re
q.html.
• If your OfficeMate installation is hosted in the cloud, contact your
hosting service to set up a VPN (virtual private network). A VPN is
required to connect your equipment to your hosted OfficeMate
database.
• This document was last updated on May 2, 2017.
Company
Equipment
Additional Information
Canon USA, Inc. (Coming
soon!)
• CX-1 Hybrid Digital
Mydriatic/Non-Mydriatic
Retinal Camera
For more information on the Canon
cameras or software, go to
www.usa.canon.com.
• CR-2 AF Digital
Non-Mydriatic Retinal
Camera
• CR-2 PLUS AF Digital
Non-Mydriatic Retinal
Camera
• imageSPECTRUM Software
®
Eyefinity EHR Equipment Integration by Company
1
Eyefinity EHR Equipment Integration by Company
Company
Equipment
Additional Information
Carl Zeiss Meditech, Inc.
FORUM
For more information on the Zeiss
equipment and software, go to
www.meditec.zeiss.com.
Humphrey Field Analyzer
HFA3
Humphrey Field Analyzer
HFA II - i Series models:
• 720i
• 740i
• 745i
Ensure that you have purchased the
networking license from Carl Zeiss
Meditech, Inc., so that you can
properly network your Humphrey Field
Analyzer and interface with
Eyefinity EHR.
• 750i
Humphrey Matrix models:
• 715
• 800
i.Com
VISULENS 500 (Coming
soon!)
VISUPLAN 500 (Coming
soon!)
VISUREF 100 (Coming
soon!)
Diopsys, Inc. (Coming soon!)
• ERG
• VEP
Heidelberg Engineering
• Heidelberg HRT2 & HRT3
• Spectralis OCT
2
For more information on Diopsys
equipment, go to www.diopsys.com.
For more information on Heidelberg
equipment, go to
www.heidelbergengineering.com/us.
Eyefinity EHR Equipment Integration by Company
Eyefinity EHR Equipment Integration by Company
Company
Equipment
Additional Information
Huvitz Co., Ltd.
• CDR-3100 Digital Refrator
For more information on Huvitz
equipment, go to
www.huvitz.com/eng/index.html.
• CLM-3000 Autolensometer
• CLM-3100 Autolensometer
• CLM-3100P
Autolensometer
• CLM-4000 Autolensometer
• DRS-3100 Digital Refractor
System
The HRK-7000 and HRK-8000
Wavefront Autorefractor/Keratometer
only import autorefraction and
keratometry data, and not wavefront
data, into Eyefinity EHR.
• HDR-7000 Digital Refractor
• HLM-7000 Autolensometer
• HRK-7000 Wavefront
Autorefractor/Keratometer
• HRK-8000 Wavefront
Autorefractor/Keratometer
• MRK-3100
Autorefractor/Keratometer
• MRK-3100P
Autorefractor/Keratometer
Kowa Optimed, Inc.
• Digital Slit Lamp Imaging
System
For more information on Kowa
equipment, go to www.kowa-usa.com.
• Genesis/VK-2 Digital
Imaging System
• nonmyd -DIII/VK-2 Digital
Imaging System
• nonmyd 7/VK-2 Digital
Imaging System
• SL-125 Slit Lamp
• VX-10/VK-2 Digital
Imaging System
• VX-20 Retinal Camera
Eyefinity EHR Equipment Integration by Company
3
Eyefinity EHR Equipment Integration by Company
Company
Equipment
Additional Information
Marco
RT-2100 (TRS-2100 or EPIC
2100), RT-5100 (EPIC 5100),
RTS-1200, TRS-3100,
TRS-5100, or RT-900
(Evolution) and one or a
combination of the following:
For more information on Marco
equipment, go to www.marco.com.
• Marco ARK-1
Autorefractor/Keratometer*
The equipment in bold is required for
Eyefinity EHR integration; however, the
equipment denoted with an asterisk (*)
can interface with Eyefinity EHR
without a Marco digital refraction
system.
• Marco ARK-1a
Autorefractor/Keratometer*
• Marco ARK-1s
Autorefractor/Keratometer*
• ARK-530A
Autorefractor/Keratometer*
• ARK-560A
Autorefractor/Keratometer*
• ARK-600 Autorefractor*
• ARK-700A
Autorefractor/Keratometer*
• ARK-710A
Autorefractor/Keratometer*
• ARK-730A
Autorefractor/Keratometer*
• ARK-760A
Autorefractor/Keratometer*
• 3D System (ARK-9000)
Autorefractor/Keratometer
• 3D Wave (ARK-10000)
Autorefractor/Keratometer
• LM-600 Autolensometer*
• LM-820A Lensometer
• LM-970 Lensometer
• LM-990A Lensometer
• LM-1000 Autolensometer*
• LM-1200 Autolensometer*
• LM-1800 Autolensometer*
• M3 TonoRef II
Autorefractor/Keratometer/
Non-Contact Tonometer*
• OPD-Scan III
4
Eyefinity EHR Equipment Integration by Company
Eyefinity EHR Equipment Integration by Company
Company
Equipment
Additional Information
Marco, continued
• Spectrum (VL-3000)
Lensometer
For more information on Marco
software, go to www.marco.com.
• RKT-7700
Autorefractor/Keratometer/
Non-Contact Tonometer*
AFC-330 Automated Fundus
Camera
You can only integrate with the
AFC-330 Automated Fundus Camera if
you are using Eyefinity EHR and
OfficeMate; this integration does not
currently work if you are using Eyefinity
Practice Management or AcuityLogic.
Marco Connect Software
NIDEK
NAVIS-EX software and the
following cameras:
• AFC-230/AFC-210
Non-Mydriatic Autofocus
Fundus Camera
• AFC-330 Non-Mydriatic
Auto Fundus Camera
• F-10 Digital
Opthalmoscope
OCULUS
• Binoptometer 4P
• Easyfield C Perimeter
For more information on NIDEK
cameras or the NAVIS-EX software, go
to http://usa.nidek.com.
You can only integrate with the
AFC-330 Non-Mydriatic Auto Fundus
Camera if you are using Eyefinity EHR
and OfficeMate; this integration does
not currently work if you are using
Eyefinity Practice Management or
AcuityLogic.
For more information on OCULUS
equipment, go to www.oculus.de/us.
• Keratograph 4
• Keratograph 5M
• Pentacam, Pentacam HR, &
Pentacam AXL (Coming
soon!)
Optos
• Daytona
• Optomap Retinal Exam
• OptosAdvance
For more information on Optos
equipment and software, go to
www.optos.com.
• V2 Vantage
Optovue
• iCam Non-Mydriatic Fundus For more information on Optovue
Camera
equipment, go to www.optovue.com.
• iVue OCT
• iFusion (iCam + iVue)
• iScan OCT
• Avanti Widefield OCT
Eyefinity EHR Equipment Integration by Company
5
Eyefinity EHR Equipment Integration by Company
Company
Equipment
Additional Information
Reichert Ophthalmic
Instruments
• AL-200 Lensometer
For more information on the Reichert
equipment, go to www.reichert.com.
• AL-500 Lensometer
• AL-700 Lensometer
• AT-555 Tonometer
• Auto Phoroptor RS
• Visutron900 Phoroptor
• Phoroptor VRx
• Foresee PHP
• IPAC Pachymeter
• PT-100 Tonometer
• Reflex UBM
• Reichert 7 Tonometer
• Reichert 7CR Tonometer
• RK-600 Autorefractor
• RK-700
Refractor/Keratometer
Synemed
6
EyeScape Digital Imaging
Systems
For more information on the EyeScape
systems, go to www.synemed.com.
Eyefinity EHR Equipment Integration by Company
Eyefinity EHR Equipment Integration by Company
Company
Equipment
Topcon Medical Systems, Inc. CV-5000 (EXAM-5000) Digital
Refractor, CV-5000S
Automated Vision Tester,
CV-3000 Digital Refractor, or
CV-2500 Digital Refractor
and one or a combination of
the following:
• CL-100 Lensometer*
• CL-200 Lensometer*
• CL-300 Lensometer*
• KR-1
Autorefractor/Keratometer*
• KR-800
Autorefractor/Keratometer*
• KR-800S
Autorefractor/Keratometer*
• KR-7000
Autorefractor/Keratometer*
• KR-7000P
Autorefractor/Keratometer*
Additional Information
For more information on Topcon
equipment and software, go to
www.topconmedical.com.
The equipment in bold is required for
Eyefinity EHR integration; however, the
equipment denoted with an asterisk (*)
can interface with Eyefinity EHR
without a Topcon digital refraction
system.
The KR-8000, KR-8900, KR-8000PA,
KR-1, KR-800, and KR-800S
Autorefractor/Keratometer only import
autorefraction and keratometry data,
and not topography images, into
Eyefinity EHR.
Topcon IMAGEnet Lite is not
supported on Microsoft Windows 8.
Topcon IMAGEnet 2000 and IMAGEnet
Lite will not be supported when
ExamWRITER 12.5 is released.
• KR-8000
Autorefractor/Keratometer*
• KR-8000PA
Autorefractor/Keratometer*
• KR-8800
Autorefractor/Keratometer*
• KR-8900
Autorefractor/Keratometer*
• RM-7000 Autorefractor
• RM-8000 Autorefractor
• RM-8800 Autorefractor
• RM-8900 Autorefractor*
Synergy Opthalmic Data
Management System
CT-80 Non Contact
Tonometer
IMAGEnet 2000,
IMAGEnet Lite, & IMAGEnet
5 (Coming soon!)
Eyefinity EHR Equipment Integration by Company
7