Safety Switches Non-Contact Switches Magnetically Coded Specifications MC1 MC2 Safety Ratings EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, ANSI B11.19, AS4024.1 Safety Classification Cat. 1 device per EN 954-1 dual channel contacts suitable for Cat. 3 or 4 systems Functional Safety Data Note: For up-to-date information, visit http://www.ab.com/Safety/ B10d = > 2 x 106 operations at min. PFHD = > 3 x 107 MTTFd = > 385 years Dual channel interlock may be suitable for Performance levels PLe or PLd (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics With the increasing speed and complexity of applications a simple magnetic switch may be insufficient to meet the increased risks, therefore the design incorporates several magnetically sensitive elements which must be triggered in a particular sequence to operate correctly. Certifications CE marked for all applicable directives, cULus, and TÜV Safety Outputs 2 N.C. REEDS 2 N.C. Solid-State Relays The sensor with its molded-in brackets and diminutive size, is extremely versatile and simple to install. For high-risk applications the control unit is used with a single sensor to give a high-integrity system. For other applications, multiple sensors (including mechanical switches) can be connected. Auxiliary Outputs — 1 PNP, 0.2 A max. Status Off (0V DC) Operating Distance, Make— mm (in) 8 (0.3) 10 (0.39) Operating Distance, Break— mm (in) 15 (0.59) 25 (0.98) Misalignment Tolerance, Min See Misalignment Wire ? Standards 1- Description 2 Features Noncontact actuation Magnetic coded sensing High tolerance to misalignment Designed for use with specified controllers Outputs (Guard Door Closed, Actuator in Place) Operating Characteristics Repeat Accuracy 10% of Sensing Range Output Current, Max. 200 mA 200 mA 3-Interlock Switches Switching Current @ Voltage, Max. 24V DC @ 200 mA 24V DC @ 200 mA +10%/-15% Operating Voltage/Power Supply — 24V DC, +10%/15%/50 mA max./Class 2 SELV Frequency of Operating Cycle 1 Hz 1 Hz Enclosure Type Rating IP 67 (NEMA 6P) IP 69K Operating Temperature—C (F) -10…+55° (+14…+131°) Environmental Relative Humidity 5…95% Shock IEC 68-2, 27, 30 g, 11 ms Vibration IEC 68-2-6, 10…55 Hz Radio Frequency IEC 61000-4-3, IEC 61000-4-6 Physical Characteristics Housing Material Molded ABS Ultrador Actuator Material Molded ABS Ultrador Color Red 4 Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years ! The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. 5 3-66 Visit our website: www.ab.com/catalogs Safety Switches Non-Contact Switches Magnetically Coded Operating Voltage/Input Current Type MC1 Safety Outputs — 2 N.C. REEDS 24V DC, +10%/15%/50 mA max. MC2 Auxiliary Outputs — 2 N.C. Solid-State Relays Connection Cat. No. 6 in Pigtail, 4-Pin Micro (M12) 440N-Z2NRS1C LED Indicator No 1 PNP, 0.2 A max. Status Off (0V DC) 3 m Cable 440N-Z2NRS1A 10 m Cable 440N-Z2NRS1B 6 in Pigtail, 8-Pin Micro (M12) 440N-Z21W1PH Yes 3 m Cable 440N-Z21W1PA 10 m Cable 440N-Z21W1PB ? Product Selection Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No. Single-Function Safety Relays for 2 N.C. Contact Switch MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC 5-24 440R-N23135 MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC 5-24 440R-N23132 MSR210P Base 2 N.C. only 2 N.O. 1 N.C. and 2 PNP Solid-State Removable Auto./Manual or Monitored Manual 24V DC from the base unit 5-74 440R-H23176 MSR220P Input Module — — Removable — 24V DC 5-78 440R-H23178 MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC 5-94 440R-W23219 MSR320P Input Module — 2 PNP Solid State Removable — 24V DC from the base unit 5-98 440R-W23218 1- Recommended Logic Interfaces 2 Modular Safety Relays Note: For additional Safety Relays connectivity, see the Logic section of this catalog. For additional Safety I/O connectivity, see the Safety I/O section of this catalog. For Application and wiring diagrams, see the Applications section of this catalog. Description Cordset Connection to Distribution Box 4-Pin Micro (M12) 8-Pin Micro (M12) 2 N.C. 2 N.C. & 1 N.O. 889D-F4AC- 889D-F8AB- 889D-F4ACDM-! 889D-F8ABDM-! Distribution Box 898D-4‡LT-DM4 — Shorting Plug 898D-41LU-DM — 898D-43LY-D4 — Patchcord T-Port 3-Interlock Switches Connection Systems Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths. ! Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths. Note: For additional information, see the Safety Connection System section of this catalog. Cat. No. 440N-A17233 MC2 Spare Actuator 440N-A32114 5 Description MC1 Spare Actuator 4 Accessories Visit our website: www.ab.com/catalogs 3-67 Safety Switches Non-Contact Switches Magnetically Coded Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. 25 (0.98) 12 (0.47) 12 (0.47) 29 (1.14) 48 (1.89) 4.2 (0.17) Dia. 22 (0.87) 48 (1.89) 25 (0.98) 24 (0.94) 2 x M4 MC2 13 (0.51) 6 (0.24) 5.5 (0.22) 24 (0.94) Ø 4.2 22 (0.87) 24 (0.94) ? 4.8 (0.19) 48 (1.89) 13 (0.51) MC1 22 (0.87) 48 (1.89) 4.2 (0.17) Dia. 22 (0.87) 2 x M4 5.5 (0.22) 4.8 (0.19) 20 (0.79) 5.5 (0.22) 53 (12.1) 20 (0.79) 29 (1.14) 1- 16.5 (0.65) 16.5 (0.65) Typical Wiring Diagrams Description MC1 MC2 2 N.C. 2 N.C. + 1 N.O. 2-Safety B 4-Pin Micro (M12) 3-Safety A 1-Safety A — 4-Safety B 8-Pin Micro (M12) — 2-Power+ 1-Aux A 2 3-N/A 8-Safety A+ 4-Safety B+ 7-Ground 6-Safety B 5-Safety A Brown 3-Interlock Switches Cordset 889D-F4ACor Cable Version Blue White Black Safety A — Safety B — Grey 8-Pin Cordset 889D-F8ABor Cable Version Safety A Red Safety A Pink Safety B Yellow White — Aux Brown 24V DC + Blue Gnd Green NA Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths. 4 5 3-68 Safety B Visit our website: www.ab.com/catalogs Safety Switches Non-Contact Switches Magnetically Coded Sensing & Misalignment Curve ? MC1 Sensor 16 14 14 12 12 8 6 10 8 6 4 4 2 2 0 6 5 4 3 2 1 0 1 2 3 4 5 0 6 1- 10 Make-Break Make-Break Actuator 16 6 5 4 3 2 1 0 1 2 3 4 5 6 MC2 Break Face A 3-Interlock Switches 2 Make MC2 Application Wiring Example Aux N/A Green (3) Safety B- White (1) Pink (6) Safety A- Yellow (4) Safety B+ 0v Safety A+ Grey (5) Red (8) Blue (7) Brown (2) +24v Magnetically Coded Small Flat Pack Red Grey +24V L1 A1 S11 S52 S12 13 23 33 L2 L3 41 4 K1 MSR127RP K2 S22 S34 A2 14 24 34 42 Pink Yellow S21 K2 M 5 K1 0V Visit our website: www.ab.com/catalogs 3-69
© Copyright 2026 Paperzz