NO AIR LEAKAGE LOW INPUT POWER BEST PUE DATA CENTER SOLUTIONS WITH ACOUSTIC PANEL PLENUMS MODELS150 250 350 450 PATENT PENDING SYSTEM PACKAGE Basic market needs for current data center designs are addressed through SEMCO’s simple approach. This system, designed specifically for data centers, incorporates few components with an easy to maintain and logical hydronic coil system achieving a typical annual Power Usage Efficiency (PUE) of 1.122 (based on Washington DC area conditions). 94˚ Data Center Return Exhaust Air Chiller Condenser Chiller Evap 74˚ Data Center Supply Outside Air The diagram above shows the basic piping arrangement between the two airstreams. Designed to handle a range of temperature differentials, this high-efficiency system not only rejects heat for the data center, but also starts to economize at an outdoor ambient temperature within 10 degrees of the desired process side leaving air temperature! This is 20-30 degrees warmer (sooner) than other air-to-air competitive options. UNIT CONFIGURATION 7 Feature set includes: 1 Scavenger side washable mesh filtration 2 Process and scavenger coil 3 Screw chiller technology with patented pumping run around loop configuration 4 Electrically commutative (EC) driven fan arrays 5 Process side pleated filtration 6 Process supply actuated damper 7 Electrically commutative (EC) driven fan arrays 8 Backdraft fan isolation dampers (not pictured) 6 5 4 3 2 1 SYSTEM FEATURES & OPTIONS: • Prepackaged with controls (providing stand-alone water cooled central plant and air handler hybrid) • Evaporative cooling (available option, but not required for superior PUE compared to all other conditioning systems) • Shipped in single piece; reduced number of lifts speeds final build DATA CENTER PUMP AND REFRIGERATION SYSTEM The key technology to lower PUE and low power input is the use of EC components (fans and pumps); however, the secret is the simple pumping design and screw chiller technology. The run-around system incorporates high capacity coils and a pump configuration that understands load management under all conditions. When ambient temperatures are too high and do not create the necessary leaving water temperature, only then does the chiller operate to provide supplemental cooling to achieve leaving water and process air temperatures. In the event that the scavenger supply water is warmer than the process return, the system will transfer into a more traditional dry cooled chiller configuration to prevent overburdening the chiller with its own heat. It should be noted that this only occurs during the few hours when the outdoor ambient temperature is greater than 90 degrees. When the outside air has cooler or cold conditions, the scavenger fans reduce in speed to further save energy. The pumps continue to run as air friction is more detrimental than fluid friction. PANEL SOLUTIONS FOR SUPERIOR PLENUMS Key benefits of using modular duct systems include: Data centers are actually large air handling units. The load is placed within this “air handler” and forced air is passed to dissipate heat. SEMCO’s AT-PANL Solutions provide acoustic-thermal plenum systems that are designed to distribute air efficiently, effectively and quietly. • COST EFFECTIVE: Various panel constructions and thicknesses allow us to customize your project and eliminate costly overkill. The need to “stick build” walls and plenums is eliminated. • EASY INSTALLATION: Roll formed tongue-and-groove construction with a fully enclosed and insulated joint allows for faster installation and a better fit with closer tolerance. • FIRE RATED & CUSTOM OPTIONS: Fire rating, various metal types, powder coating and finishes are available to customize the system. www.semcohvac.com SEMCO DATA CENTER BR - DWP WE BRING AIR TO LIFE WWW.SEMCOHVAC.COM | DATA CENTER | 20170403 SEMCO® is a global leader in air management. We specialize in the design and manufacture of a wide range of air climate and air movement solutions. Our collective experience is unrivaled. WE BRING AIR TO LIFE Our constant aim is to provide systems that precisely deliver the best indoor air quality and performance, as well as maximize energy efficiency. SEMCO® A FläktGroup Brand Corporate Headquarters 1800 East Pointe Drive Columbia, Missouri 65201 USA 573 443 1481 [email protected] To learn more about SEMCO offerings and to contact your nearest representative please visit www.semcohvac.com SEMCO embraces a policy of continuous development and improvement, the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied upon request on receipt of order. PATENT PENDING. © SEMCO LLC 2017 All Rights Reserved. SEMCO and the SEMCO logo are registered Trademarks of SEMCO LLC.
© Copyright 2026 Paperzz