SUBMITTAL DATA SHEET ® SPLIT SYSTEM EVAPORATOR BLOWER - HEAT PUMP 7-1/2 TONS - MODELS: FA090 JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. MODEL NO. DIMENSIONS - INCHES PRODUCT DATA 1-3/8" KNOCKOUT FOR POWER WIRING (Back Panel) Do not remove this knockout when the unit is equipped with an Electric Heat Accessory. Refer to detail of the Heater Accessory for power wiring access opening Cooling Performance Total Capacity .................______________ MBH Sensible Capacity ...........______________ MBH 52-1/4 15-3/8 Evaporator Pressure 1-23/32 KNOCKOUT (Removed only when Electric Heat Accessory is used) at Saturation .................. _______________ PSI 7/8" HOLE W/BUSHING FOR CONTROL WIRING (Back Panel) 18-7/8 AIR OUT 3-5/8 4-1/4 1 Evaporator Temperature 5/8 16-1/8 2-1/4 at Saturation ................. ______________ °F 6-3/4 25-7/8 15 BLOWER MOTOR AND DRIVE ACCESS PANEL (This side only) Total Supply Air .............. ______________ CFM Temp. of Air Entering HOLE WITH GROMMET FOR 1/2 O.D. LIQUID LINE Evaporator Coil..... _______/______°F DB/WB 51-1/8 Heating Performance 23 Refer to field-installed accessories on reverse side 4 8-3/8 1-5/8 2-5/8 Supply Air Blower Performance 3-1/4 Total Supply Air .......... _________________CFM AIR IN 2 25-1/8 48 Blower Speed.............._________________RPM 2 Motor Rating ................__________________HP A IR O U T (S td . A rra n g e m e n t) Total Unit Ampacity .. ________________AMPS Max. Fuse Size Dual Element R E T U R N A IR D U C T FLA N G E B LO W E R S E C T IO N B LO W E R S E C T IO N Side with RETURN AIR opening....................... 24” Side with SUPPLY AIR opening....................... 24”1 Side with PIPING CONNECTION .................... 61”2 Side opposite PIPING CONNECTION ............. 26”3 Bottom.................................................................. 4 1 Overall dimension of the unit will vary if an electric heater, a supply air plenum or a base is used. 2 This dimension is required for removal of the coil. Only 26” is required for normal servicing. 3 If the coil has to be removed, this dimension is required to loosen screws that secure the coil to the unit frame. This dimension will also be required for blower motor access if the piping connections are made on the opposite side of the unit. 4 Allow enough clearance to trap the condensate drain line. _______AMPS Unit Weight Total Operating Weight ________________LBS (Including field-installed accessories) Matching Condensing Unit Data Model Number_____________________ Submittal Form Number______________ Unitary Products Group MINIMUM CLEARANCES B LO W E R M O TO R L O C A T IO N Power Supply. ........... ________________AMPS (Copper Conductors) FILTER ACCESS PANEL (When unit is installed in a horizontal position,do not block this area with refrigerant piping) APPLICATION Electrical Data Min. Wire Size .......... _________________AWG 7/8 O.D. DRAIN CONN. (Must be trapped) 1 PWR Output Req. ....... _________________BHP PWR Input Req. .......... __________________kW 1-3/4 1-1/8 Total Resistance External To Unit ________IWG HOLE WITH GROMMET FOR 1-1/8 O.D. SUCTION LINE 1-3/8 R E T U R N A IR D U C T FLA N G E E V A P O R A TO R C O IL A IR IN C O IL S E C T IO N F IL T E R S V E R T IC A L P O S IT IO N F IL T E R S H O R IZ O N T A L P O S IT IO N A L T E R N A T E A IR D IS C H A R G E A R R A N G E M E N T S N O T E : C E R T A IN B L O W E R P O S IT IO N S A R E N O T R E C O M M E N D E D . B E C A U S E TH E B LO W E R M O TO R S H O U LD N O T B E M O U N TE D U P S ID E D O W N . 036-22182-002-A-0902 ELECTRIC HEATER ACCESSORY (40 Lb.) C BASE BASIC UNIT SUSPENSION WEIGHTS (LBS.) HANGER RODS (FIELD SUPPLIED) SUSPENSION CHANNEL 55" 5" Susp’n Point 58-11/16" A 24 BLOWER SECTION 3 1-1/2 COIL SECTION D 31 5/8 SUSPENSION ACCESSORY ARRANGEMENT/ 7-1/2 TON BASE With Heater Access With Plenum Access 95 120 95 115 425 95 120 115 140 470 85 100 165 185 535 A B C D Total Wt. B SUPPLY AIR PLENUM ACCESSORY (100 Lb.) 60 3/4 With 2 HP Motor With Heater & Plenum Access 85 100 185 205 575 60-3/4 FIELD-INSTALLED ACCESSORIES SUPPLY AIR PLENUM (1SP0452) ......................................... RETURN AIR GRILLE(1RG0451)........................................... BASE (1BS0452) ................................................................... (Vertical Application Only) ....................................................... SUSPENSION PACKAGE(1HH0451)..................................... (Horizontal Application Only) ELECTRIC HEATER*.............................................................. Model Number........ ________________________________ Capacity (@______Volts) .......... _________________MBH Power Input Requirement ..........__________________ kW (Less Blower Motor) STEAM COIL (1NF0452) ........................................................ Steam Pressure .........................._________________PSIG Capacity .................................... ________________ MGB Steam Rate .................................._______________LBS/HR Entering Air Temperature ......... ____________________°F HOT WATER (1HW0452) Capacity................................... __________________MBH Entering Water Temperature.... ____________________°F Water Flow Rate ...................... __________________GPM Entering Air Temperature.........____________________°F Water Pressure Drop.............. ___________________PSI. 6 3 -2 7 /3 2 3 2 -1 /4 2 31 3 -1 /4 RETURN AIR GRILLE 5/8 2 -1 1 /1 6 6 0 -3 /4 HOT WATER COIL 2 -5 /3 2 1 1 9 -7 /8 1 9 -1 /2 2 7 6 1 - 1 /2 " N P T E C O N N S . 3 2 - 1 /4 6 -1 /8 1 -3 /4 2 -1 /2 1 7 - 1 /2 5 5 -3 /4 6 0 -3 /4 SUPPLY AIR PLENUM 3 1 1 -1 /8 3 - 1 /2 6 0 - 3 /4 3 2 -1 /2 K N O C K O U T F O R P O W E R W IR IN G W H E N E L E C T R IC H E A T E R IS U S E D 2 STEAM COIL * Units with electric heat have a single source power supply. Refer to Product Data on front side for electric data. D 1 L E F M G C HEATER ELEMENT CHAMBER H K 3/4 B A 1/2 WIRING HARNESS LOCATION This opening in the bottom of the heater control box is used for the wiring harness that connects the heater accessory to the basic unit. It is provided with a squeeze connector for securing the wiring harness, and its location corresponds to the location of the 1-23/32 inch knockout in the top panel of the basic unit. ACCESS OPENING FOR POWER SUPPLY WIRING 10KW THRU 30KW - Add a 1-1/4 inch conduit fitting to the 1-23/32 inch hole for wire sizes up through #1 AWG. Remove the knockout ring and add a 1-1/2 inch conduit fitting to the 1-31/32 inch hole for wire sizes up through #0 AWG. 50 KW - Add a 1-1/4 inch conduit fitting to the 1-23/32 inch hole for wire sizes up through #1\ AWG. Remove the knockout ring and add a two-inches conduit fitting to the 2-1/2" hole for wire sizes up through #000 AWG. Used on FEH180 only. CONTROL BOX ACCESS PANEL ELECTRIC HEATER DIMENSIONS Heater Model Nom. kW 2HS04501025, 46 10 2HS04501605, 46 16 2HS04502625, 46 26 2HS04503625, 46 36 2HS04507225, 46 72 Subject to change without notice. Printed in U.S.A. Copyright © by Unitary Products Group 2002. All rights reserved. Unitary Products Group Heater Dimensions (inches) A B C 27-1/4 25-1/4 14-1/4 D E 1 4 F G H K 1/2 5-1/2 1-1/2 1-1/2 29-7/8 26-3/8 21-3/4 2-3/8 5-1/4 3/4 6-3/4 2-1/4 2-1/2 036-22182-002-A-0902 Supersedes: 036-22182-001-A-0502 5005 York Drive Norman OK 73069
© Copyright 2025 Paperzz