Y-SD, Split System Evaporator Blower - Heat Pump 7

SUBMITTAL DATA SHEET
®
SPLIT SYSTEM
EVAPORATOR BLOWER - HEAT PUMP
7-1/2 TONS - MODELS: FA090
JOB NAME:
LOCATION:
PURCHASER:
ORDER NO:
ENGINEER:
SUBMITTED TO:
FOR:
REF:
APPROVAL:
CONSTRUCTION:
SUBMITTED BY:
DATE:
UNIT DESIGNATION:
SCHEDULE NO.
MODEL NO.
DIMENSIONS - INCHES
PRODUCT DATA
1-3/8" KNOCKOUT
FOR POWER WIRING (Back Panel)
Do not remove this knockout when
the unit is equipped with an Electric
Heat Accessory. Refer to detail of
the Heater Accessory for power
wiring access opening
Cooling Performance
Total Capacity .................______________ MBH
Sensible Capacity ...........______________ MBH
52-1/4
15-3/8
Evaporator Pressure
1-23/32 KNOCKOUT
(Removed only when
Electric Heat Accessory
is used)
at Saturation .................. _______________ PSI
7/8" HOLE W/BUSHING
FOR CONTROL
WIRING
(Back Panel)
18-7/8
AIR
OUT
3-5/8
4-1/4
1
Evaporator Temperature
5/8
16-1/8
2-1/4
at Saturation ................. ______________ °F
6-3/4
25-7/8
15
BLOWER MOTOR
AND DRIVE
ACCESS PANEL
(This side only)
Total Supply Air .............. ______________ CFM
Temp. of Air Entering
HOLE WITH GROMMET FOR 1/2 O.D.
LIQUID LINE
Evaporator Coil..... _______/______°F DB/WB
51-1/8
Heating Performance
23
Refer to field-installed accessories on reverse
side
4
8-3/8
1-5/8
2-5/8
Supply Air Blower Performance
3-1/4
Total Supply Air .......... _________________CFM
AIR
IN
2
25-1/8
48
Blower Speed.............._________________RPM
2
Motor Rating ................__________________HP
A IR O U T
(S td . A rra n g e m e n t)
Total Unit Ampacity .. ________________AMPS
Max. Fuse Size Dual Element
R E T U R N A IR
D U C T FLA N G E
B LO W E R
S E C T IO N
B LO W E R
S E C T IO N
Side with RETURN AIR opening....................... 24”
Side with SUPPLY AIR opening....................... 24”1
Side with PIPING CONNECTION .................... 61”2
Side opposite PIPING CONNECTION ............. 26”3
Bottom.................................................................. 4
1
Overall dimension of the unit will vary if an electric
heater, a supply air plenum or a base is used.
2
This dimension is required for removal of the coil.
Only 26” is required for normal servicing.
3
If the coil has to be removed, this dimension is
required to loosen screws that secure the coil to the
unit frame. This dimension will also be required for
blower motor access if the piping connections are
made on the opposite side of the unit.
4
Allow enough clearance to trap the condensate drain
line.
_______AMPS
Unit Weight
Total Operating Weight ________________LBS
(Including field-installed accessories)
Matching Condensing Unit Data
Model Number_____________________
Submittal Form Number______________
Unitary Products Group
MINIMUM CLEARANCES
B LO W E R M O TO R
L O C A T IO N
Power Supply. ........... ________________AMPS
(Copper Conductors)
FILTER ACCESS PANEL
(When unit is installed in
a horizontal position,do
not block this area with
refrigerant piping)
APPLICATION
Electrical Data
Min. Wire Size .......... _________________AWG
7/8 O.D. DRAIN
CONN. (Must be
trapped)
1
PWR Output Req. ....... _________________BHP
PWR Input Req. .......... __________________kW
1-3/4
1-1/8
Total Resistance External To Unit ________IWG
HOLE WITH GROMMET FOR 1-1/8 O.D.
SUCTION LINE
1-3/8
R E T U R N A IR
D U C T FLA N G E
E V A P O R A TO R
C O IL
A IR
IN
C O IL
S E C T IO N
F IL T E R S
V E R T IC A L
P O S IT IO N
F IL T E R S
H O R IZ O N T A L
P O S IT IO N
A L T E R N A T E A IR
D IS C H A R G E A R R A N G E M E N T S
N O T E : C E R T A IN B L O W E R P O S IT IO N S A R E N O T R E C O M M E N D E D .
B E C A U S E TH E B LO W E R M O TO R S H O U LD N O T B E M O U N TE D
U P S ID E D O W N .
036-22182-002-A-0902
ELECTRIC HEATER
ACCESSORY (40 Lb.)
C
BASE
BASIC UNIT SUSPENSION WEIGHTS (LBS.)
HANGER RODS
(FIELD SUPPLIED)
SUSPENSION
CHANNEL
55"
5"
Susp’n
Point
58-11/16"
A
24
BLOWER
SECTION
3
1-1/2
COIL
SECTION
D
31 5/8
SUSPENSION ACCESSORY
ARRANGEMENT/ 7-1/2 TON
BASE
With
Heater
Access
With Plenum
Access
95
120
95
115
425
95
120
115
140
470
85
100
165
185
535
A
B
C
D
Total Wt.
B
SUPPLY AIR PLENUM
ACCESSORY (100 Lb.)
60 3/4
With
2 HP
Motor
With
Heater &
Plenum
Access
85
100
185
205
575
60-3/4
FIELD-INSTALLED ACCESSORIES
SUPPLY AIR PLENUM (1SP0452) .........................................
RETURN AIR GRILLE(1RG0451)...........................................
BASE (1BS0452) ...................................................................
(Vertical Application Only) .......................................................
SUSPENSION PACKAGE(1HH0451).....................................
(Horizontal Application Only)
ELECTRIC HEATER*..............................................................
Model Number........ ________________________________
Capacity (@______Volts) .......... _________________MBH
Power Input Requirement ..........__________________ kW
(Less Blower Motor)
STEAM COIL (1NF0452) ........................................................
Steam Pressure .........................._________________PSIG
Capacity .................................... ________________ MGB
Steam Rate .................................._______________LBS/HR
Entering Air Temperature ......... ____________________°F
HOT WATER (1HW0452)
Capacity................................... __________________MBH
Entering Water Temperature.... ____________________°F
Water Flow Rate ...................... __________________GPM
Entering Air Temperature.........____________________°F
Water Pressure Drop.............. ___________________PSI.
6
3 -2 7 /3 2
3 2 -1 /4
2
31
3 -1 /4
RETURN
AIR GRILLE
5/8
2 -1 1 /1 6
6 0 -3 /4
HOT
WATER
COIL
2 -5 /3 2
1
1 9 -7 /8
1 9 -1 /2
2 7
6
1 - 1 /2 " N P T E
C O N N S .
3 2 - 1 /4
6 -1 /8
1 -3 /4
2 -1 /2
1 7 - 1 /2
5 5 -3 /4
6 0 -3 /4
SUPPLY AIR
PLENUM
3 1
1 -1 /8
3 - 1 /2
6 0 - 3 /4
3
2 -1 /2 K N O C K O U T F O R P O W E R W IR IN G
W H E N E L E C T R IC H E A T E R IS U S E D
2
STEAM COIL
* Units with electric heat have a single source power supply.
Refer to Product Data on front side for electric data.
D
1
L
E
F
M
G
C
HEATER
ELEMENT
CHAMBER
H
K
3/4
B
A
1/2
WIRING HARNESS LOCATION
This opening in the bottom of the heater
control box is used for the wiring harness
that connects the heater accessory to the
basic unit. It is provided with a squeeze
connector for securing the wiring harness,
and its location corresponds to the location of the 1-23/32 inch knockout in the top
panel of the basic unit.
ACCESS OPENING FOR POWER SUPPLY WIRING
10KW THRU 30KW - Add a 1-1/4 inch conduit fitting
to the 1-23/32 inch hole for wire sizes up through
#1 AWG. Remove the knockout ring and add a
1-1/2 inch conduit fitting to the 1-31/32 inch hole
for wire sizes up through #0 AWG.
50 KW - Add a 1-1/4 inch conduit fitting to the
1-23/32 inch hole for wire sizes up through #1\
AWG. Remove the knockout ring and add a
two-inches conduit fitting to the 2-1/2" hole
for wire sizes up through #000 AWG.
Used on FEH180 only.
CONTROL BOX
ACCESS PANEL
ELECTRIC HEATER DIMENSIONS
Heater Model
Nom.
kW
2HS04501025, 46
10
2HS04501605, 46
16
2HS04502625, 46
26
2HS04503625, 46
36
2HS04507225, 46
72
Subject to change without notice. Printed in U.S.A.
Copyright © by Unitary Products Group 2002. All rights reserved.
Unitary
Products
Group
Heater Dimensions (inches)
A
B
C
27-1/4 25-1/4 14-1/4
D
E
1
4
F
G
H
K
1/2 5-1/2 1-1/2 1-1/2
29-7/8 26-3/8 21-3/4 2-3/8 5-1/4 3/4 6-3/4 2-1/4 2-1/2
036-22182-002-A-0902
Supersedes: 036-22182-001-A-0502
5005
York
Drive
Norman
OK
73069