DNV SERVICE SPECIFICATIONS, STANDARDS AND RECOMMENDED PRACTICES Summary of Changes and Current Document Status OCTOBER 2013 DET NORSKE VERITAS AS FOREWORD DNV is a global provider of knowledge for managing risk. Today, safe and responsible business conduct is both a license to operate and a competitive advantage. Our core competence is to identify, assess, and advise on risk management. From our leading position in certification, classification, verification, and training, we develop and apply standards and best practices. This helps our customers safely and responsibly improve their business performance. DNV is an independent organisation with dedicated risk professionals in more than 100 countries, with the purpose of safeguarding life, property and the environment. DNV service documents consist of among others the following types of documents: — Service Specifications. Procedural requirements. — Standards. Technical requirements. — Recommended Practices. Guidance. The Standards and Recommended Practices are offered within the following areas: A) Qualification, Quality and Safety Methodology B) Materials Technology C) Structures D) Systems E) Special Facilities F) Pipelines and Risers G) Asset Operation H) Marine Operations J) Cleaner Energy O) Subsea Systems U) Unconventional Oil & Gas © Det Norske Veritas AS October 2013 Any comments may be sent by e-mail to [email protected] This service document has been prepared based on available knowledge, technology and/or information at the time of issuance of this document, and is believed to reflect the best of contemporary technology. The use of this document by others than DNV is at the user's sole risk. DNV does not accept any liability or responsibility for loss or damages resulting from any use of this document. Summary of Changes and Current Document Status, October 2013 Contents – Page 3 CONTENTS Sec. 1 General ................................................................................................................................................ 4 Sec. 2 Current Service Specifications, Standards and Recommended Practices .................................... 5 Sec. 3 Summary of Changes ......................................................................................................................... 9 1 Changes to DNV Service Specifications ........................................................................................................ 9 2 Changes to DNV Standards .......................................................................................................................... 13 3 Changes to DNV Recommended Practices .................................................................................................. 27 DET NORSKE VERITAS AS Summary of Changes and Current Document Status, October 2013 Sec.1 General – Page 4 SECTION 1 GENERAL As of October 2010 all DNV service documents are primarily published electronically and they are made available for free as pdf files through http://www.dnv.com. The electronic pdf versions of the documents found through the same site are the officially binding versions. Readers of documents are encouraged to regularly check for updates in order to ensure that they hold the current updated versions. Updating Scheme These documents are published throughout the year except DNV Offshore Service Specifications and Offshore Standards which are normally published twice yearly, in April and in October. If a document has been updated, the document will normally be given a new edition date. The corresponding Adobe PDF file will be made available through http://www.dnv.com and the date of the column “A” of Table 2-1 in Sec.2 will be updated. If there is a need for amendments to the document; i.e. editorial and clarification corrections only, the electronic file will be updated, but the edition date will be retained. However, a new Adobe PDF file will be generated and made available through http://www.dnv.com. The date of the PDF file will appear in column “B” of Table 2-1 in Sec.2. The changes will be described on page 3 of each document. Historic changes are to be found at the end of each document as from July 2013. DET NORSKE VERITAS AS Summary of Changes and Current Document Status, October 2013 Sec.2 Current Service Specifications, Standards and Recommended Practices – Page 5 SECTION 2 CURRENT SERVICE SPECIFICATIONS, STANDARDS AND RECOMMENDED PRACTICES Table 2-1 Current Documents Documents A Current Edition B Amendments; i.e. editorial corrections and clarifications only 2012-07 2010-10 2010-10 2012-12 2012-06 2012-01 – 2012-04 2012-04 – 2013-07 2013-02 2013-10 – 2012-04 – 2012-04 – 2012-04 – 2008-10 2011-10 2013-10 2011-04 2004-04 2000-10 2010-10 2006-10 2010-10 2004-06 2004-06 2010-10 2008-10 2009-04 2012-06 – 2011-10 2012-04 2012-04 2012-04 2012-04 2011-10 2012-04 2012-04 2012-04 2012-04 2011-10 2012-07 – 2010-10 2010-11 2013-10 2013-10 2012-10 2011-04 2012-10 2012-10 2012-04 2011-04 – – – – – – – – 2012-04 – 2012-10 2013-10 – – Service Specifications DNV-DSS-105 DNV-DSS-314 DNV-DSS-315 DNV-DSS-401 DNV-DSS-402 DNV-DSS-904 Rules for Classification of Diving Systems Verification of Hydrocarbon Refining and Petrochemical Facilities Verification of Onshore LNG and Gas Facilities Technology Qualification Management Qualification Management for Geological Storage of CO2 Type Certification of Wind Turbines Offshore Service Specifications DNV-OSS-101 Rules for Classification of Offshore Drilling and Support Units DNV-OSS-102 Rules for Classification of Floating Production, Storage and Loading Units DNV-OSS-103 Rules for Classification of Floating LNG/LPG Production, Storage and Loading Units DNV-OSS-104 Rules for Classification of Self-Elevating Units DNV-OSS-121 Classification Based on Performance Criteria Determined from Risk Assessment Methodology DNV-OSS-201 Verification for Compliance with Norwegian Shelf Regulations DNV-OSS-202 Verification for Compliance with UK Shelf Regulations DNV-OSS-300 Risk Based Verification DNV-OSS-301 Certification and Verification of Pipelines DNV-OSS-302 Offshore Riser Systems DNV-OSS-304 Risk Based Verification of Offshore Structures DNV-OSS-305 Rules for Certification and Verification of Diving Systems DNV-OSS-306 Verification of Subsea Facilities DNV-OSS-307 Verification of Process Facilities DNV-OSS-308 Verification of Lifting Appliances for the Oil and Gas Industry DNV-OSS-312 Certification of Tidal and Wave Energy Converters DNV-OSS-313 Pipe Mill and Coating Yard - Qualification DNV-OSS-901 Project Certification of Offshore Wind Farms Standards DNV-DS-E403 Standard for Surface Diving Systems DNV-DS-J102 Design and Manufacture of Wind Turbine Blades, Offshore and Onshore Wind Turbines Offshore Standards DNV-OS-A101 DNV-OS-A201 DNV-OS-B101 DNV-OS-C101 DNV-OS-C102 DNV-OS-C103 DNV-OS-C104 DNV-OS-C105 DNV-OS-C106 Safety Principles and Arrangements Winterization for Cold Climate Operations (Tentative) Metallic Materials Design of Offshore Steel Structures, General (LRFD Method) Structural Design of Offshore Ships Structural Design of Column Stabilised Units (LRFD Method) Structural Design of Self-Elevating Units (LRFD Method) Structural Design of TLPs (LRFD Method) Structural Design of Deep Draught Floating Units/Spars (LRFD and WSD Method) DNV-OS-C201 Structural Design of Offshore Units (WSD Method) DNV-OS-C301 Stability and Watertight Integrity DET NORSKE VERITAS AS Summary of Changes and Current Document Status, October 2013 Sec.2 Current Service Specifications, Standards and Recommended Practices – Page 6 Table 2-1 Current Documents (Continued) Documents DNV-OS-C401 DNV-OS-C501 DNV-OS-C502 DNV-OS-C503 DNV-OS-D101 DNV-OS-D201 DNV-OS-D202 DNV-OS-D203 DNV-OS-D301 DNV-OS-E101 DNV-OS-E201 DNV-OS-E301 DNV-OS-E302 DNV-OS-E303 DNV-OS-E304 DNV-OS-E401 DNV-OS-E402 DNV-OS-E403 DNV-OS-E406 DNV-OS-E407 DNV-OS-F101 DNV-OS-F201 DNV-OS-H101 DNV-OS-H102 DNV-OS-H201 DNV-OS-H203 DNV-OS-J101 DNV-OS-J103 DNV-OS-J201 DNV-OS-J301 Fabrication and Testing of Offshore Structures Composite Components Offshore Concrete Structures Concrete LNG Terminal Structures and Containment Systems Marine and Machinery Systems and Equipment Electrical Installations Automation, Safety and Telecommunication Systems Integrated Software Dependent System (ISDS) Fire Protection Drilling Plant Oil and Gas Processing Systems Position Mooring Offshore Mooring Chain Offshore Fibre Ropes Offshore Mooring Steel Wire Ropes Helicopter Decks Offshore Standard for Diving Systems Offshore Loading Buoys Design of Free Fall Lifeboats Underwater Deployment & Recovery Systems Submarine Pipeline Systems Dynamic Risers Marine Operations, General Marine Operations, Design and Fabrication Load Transfer Operations Transit and Positioning of Offshore Units Design of Offshore Wind Turbine Structures Design of Floating Wind Turbine Structures Offshore Substations for Wind Farms Wind Turbine Installation Units A Current Edition 2013-04 2010-10 2012-09 2010-10 2013-10 2013-10 2013-10 2012-12 2013-10 2013-10 2013-04 2013-10 2013-10 2013-02 2013-10 2012-04 2010-10 2008-10 2010-04 2012-10 2013-10 2010-10 2011-10 2012-01 2012-04 2012-02 2013-01 2013-06 2009-10 2013-04 B Amendments; i.e. editorial corrections and clarifications only – – – – – – – – – – – – – – – – – – – – – – – – – 2013-02 – – 2013-07 Recommended Practices DNV-RP-A201 DNV-RP-A203 DNV-RP-A204 DNV-RP-A205 DNV-RP-B101 DNV-RP-B401 DNV-RP-C101 DNV-RP-C102 DNV-RP-C103 DNV-RP-C104 DNV-RP-C201 DNV-RP-C202 DNV-RP-C203 DNV-RP-C204 DNV-RP-C205 DNV-RP-C206 DNV-RP-C207 DNV-RP-C208 Plan Approval Documentation Types – Definitions Technology Qualification Quality Survey Plan (QSP) for Offshore Class New-building Surveys Offshore Classification Projects - Testing and Commissioning Corrosion Protection of Floating Production and Storage Units Cathodic Protection Design Allowable Thickness Diminution for Hull Structure of Offshore Ships Structural Design of Offshore Ships Column-Stabilised Units Self-elevating Units Buckling Strength of Plated Structures Buckling Strength of Shells Fatigue Design of Offshore Steel Structures Design against Accidental Loads Environmental Conditions and Environmental Loads Fatigue Methodology of Offshore Ships Statistical Representation of Soil Data Determination of Structural Capacity by Non-linear FE Analysis Methods DET NORSKE VERITAS AS 2012-04 2013-07 2011-09 2013-10 2007-04 2010-10 2007-04 2002-02 2012-04 2012-11 2010-10 2013-01 2012-10 2010-10 2010-10 2012-10 2012-01 – – – – – 2011-04 – – – – – – – – – – – 2013-07 – Summary of Changes and Current Document Status, October 2013 Sec.2 Current Service Specifications, Standards and Recommended Practices – Page 7 Table 2-1 Current Documents (Continued) Documents DNV-RP-C301 Design, Fabrication, Operation and Qualification of Bonded Repair of Steel Structures DNV-RP-C302 Risk Based Corrosion Management DNV-RP-D101 Structural Analysis of Piping Systems DNV-RP-D102 Failure Mode and Effect Analysis (FMEA) of Redundant Systems DNV-RP-D201 Integrated Software Dependent Systems DNV-RP-D202 Witnessing of Low Sulphur Fuel Changeover and Operations DNV-RP-E101 Recertification of Well Control Equipment for the Norwegian Continental Shelf DNV-RP-E102 Recertification of Blowout Preventers and Well Control Equipment for the US Outer Continental Shelf DNV-RP-E301 Design and Installation of Fluke Anchors in Clay DNV-RP-E302 Design and Installation of Plate Anchors in Clay DNV-RP-E303 Geotechnical Design and Installation of Suction Anchors in Clay DNV-RP-E304 Damage Assessment of Fibre Ropes for Offshore Mooring DNV-RP-E306 Dynamic Positioning Vessel Design Philosophy Guidelines DNV-RP-E307 Dynamic Positioning Systems - Operation Guidance DNV-RP-E401 Survey of Diving Systems DNV-RP-E402 Naval Rescue Submersibles DNV-RP-E403 Hyperbaric Evacuation Systems DNV-RP-F101 Corroded Pipelines DNV-RP-F102 Pipeline Field Joint Coating and Field Repair of Linepipe Coating DNV-RP-F103 Cathodic Protection of Submarine Pipelines by Galvanic Anodes DNV-RP-F105 Free Spanning Pipelines DNV-RP-F106 Factory Applied External Pipeline Coatings for Corrosion Control DNV-RP-F107 Risk Assessment of Pipeline Protection DNV-RP-F108 Fracture Control for Pipeline Installation Methods Introducing Cyclic Plastic Strain DNV-RP-F109 On-Bottom Stability Design of Submarine Pipelines DNV-RP-F110 Global Buckling of Submarine Pipelines Structural Design due to High Temperature/High Pressure DNV-RP-F111 Interference Between Trawl Gear and Pipelines DNV-RP-F112 Design of Duplex Stainless Steel Subsea Equipment Exposed to Cathodic Protection DNV-RP-F113 Pipeline Subsea Repair DNV-RP-F116 Integrity Management of Submarine Pipeline Systems DNV-RP-F118 Pipe Girth Weld AUT System Qualification and Project Specific Procedure Validation DNV-RP-F201 Design of Titanium Risers DNV-RP-F202 Composite Risers DNV-RP-F203 Riser Interference DNV-RP-F204 Riser Fatigue DNV-RP-F205 Global Performance Analysis of Deepwater Floating Structures DNV-RP-F206 Riser Integrity Management DNV-RP-F301 Subsea Separator Structural Design DNV-RP-F302 Selection and Use of Subsea Leak Detection Systems DNV-RP-F401 Electrical Power Cables in Subsea Applications DNV-RP-G101 Risk Based Inspection of Offshore Topsides Static Mechanical Equipment DNV-RP-G103 Non-intrusive Inspection DNV-RP-H101 Risk Management in Marine - and Subsea Operations DET NORSKE VERITAS AS A Current Edition B Amendments; i.e. editorial corrections and clarifications only 2012-04 – 2012-04 2008-10 2012-01 2009-10 2013-10 – – – – – 2012-01 – 2012-01 – 2012-05 2002-12 2005-10 2005-04 2012-09 2011-01 2007-04 2010-10 2010-10 2010-10 2011-05 2010-10 2006-02 2011-05 2010-10 – – – – – – – – – – – – – – – 2006-01 – 2010-10 2011-11 2007-10 – 2010-10 – 2008-10 – 2007-10 2009-10 – – 2010-10 – 2002-10 2010-10 2009-04 2010-10 2010-10 2008-04 2007-04 2010-04 2012-02 – – – – – – – – – 2010-10 – 2011-01 2003-01 – – Summary of Changes and Current Document Status, October 2013 Sec.2 Current Service Specifications, Standards and Recommended Practices – Page 8 Table 2-1 Current Documents (Continued) Documents DNV-RP-H102 Marine operations during Removal of Offshore Installations DNV-RP-H103 Modelling and Analysis of Marine Operations DNV-RP-H104 Ballast, Stability, and Watertight Integrity -Planning and Operating Guidance DNV-RP-J101 Use of Remote Sensing for Wind Energy Assessments DNV-RP-J201 Qualification Procedures for CO2 Capture Technology DNV-RP-J202 Design and Operation of CO2 Pipelines DNV-RP-J203 Geological Storage of Carbon Dioxide DNV-RP-O401 Safety and Reliability of Subsea Systems DNV-RP-O501 Erosive Wear in Piping Systems DNV-RP-U301 Risk Management of Shale Gas Developments and Operations DET NORSKE VERITAS AS A Current Edition 2004-04 2011-04 B Amendments; i.e. editorial corrections and clarifications only – 2012-12 2011-09 – 2011-04 2010-04 2010-04 2012-04 1985-04 2007-11 2013-01 2011-11 – – 2013-07 – 2011-01 DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 9 SECTION 3 SUMMARY OF CHANGES 1 Changes to DNV Service Specifications Table 3-1 DNV Service Specifications Document number DNV-OSS-101 October 2013 Document title Changes Rules for Classification of General Offshore Drilling and Support Specific for this edition Units Significant changes have been highlighted throughout the document. For clarity, the following changes have not been highlighted: — content based on existing requirements from reference documents — interpretations based on old rule requirements — editorial restructuring and moves. — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101 Ch.2 Sec.3 D506” is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6]”. — The content has been balanced by describing survey requirements applicable for all units, followed by vessel type specific requirements for all periodical surveys and applicable areas (typically with regard to hull and equipment). — Periodical survey requirements have been aligned with the Rules for Classification of Ships (Rules for Ships). — Gas turbine inspection requirements have been covered. — The position/ use of DNV-OSS-101 with regard to DNV-OSS104 has been clarified. — Service unit survey requirements have been clarified and focused, among others by including specific sub-section on scope. — A new App.B on mooring equipment acceptance standard guidance, originally placed inside the main text, has been included. — More extensive descriptions with regard to our follow up on ageing units have been included. — Descriptions for alternative survey arrangements have been updated. Ch.1 General — Definition of EU Mutual Recognition Type Approval Certificate has been included. Ch.1 Sec.3 Classification scope and notations — The overview of class notations in [2] has been updated. Ch.2 General — Scope of classification with regard to structural design has been clarified in Sec.2 [3] and Sec.1 [4]. Ch.3 General — The text has been restructured by: 1) Restructuring content of Sec.2 and previous Sec.4 A. 2) Deleting previous Sec.3 on alternative survey arrangements and service suppliers and moving the content to respectively Sec.7 and Sec.8. 3) Separating Miscellaneous main class surveys from Sec.3. Ch.3 Sec.1 General provisions — Updated overview table of periodical surveys. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 10 DNV-OSS-101 (continued) October 2013 Rules for Classification of Ch.3 Sec.2 General requirements for structure and machinery Offshore Drilling and Support surveys Units — Aligned with relevant description of Rules for Ships. (continued) — Reference to RP for bonded patch repairs. Ch.3 Sec.3 (previous Sec.4) Periodical survey extent for main class — [1] General: — Updated IIP scope table. — [2] Annual survey – main class: — Content has been rewritten based on applicable Rules for Ships and IACS. — The text has been restructured as described above. — [3] Intermediate survey: — Content has been rewritten based on applicable Rules for Ships and IACS. — The text has been restructured as described above. — Specific requirements for units > 10 years have been added. — [4] Renewal survey, structure and equipment: — Content has been rewritten based on applicable Rules for Ships and IACS. — The text has been restructured as described above. — Thickness measurement tables for different vessel types have been included. — Special, primary and secondary areas for inspection for different vessel types have been listed. — Tail shaft sealing inspection for non-self-propelled units has been included. — [5] Renewal survey, machinery and safety systems: — Content has been rewritten based on applicable Rules for Ships and IACS. — The text has been restructured as described above. Ch.3 Sec.4 Miscellaneous main class surveys — The text has been cleaned up by to a larger degree referring to relevant Rules for Ships. Ch.3 Sec.5 Periodical survey extent for additional service notations — Specific survey requirements for the different service notations have been updated. — Scope for each service notation has been clarified. — Wind Turbine Installation units and Offshore Support units have been included. Ch.3 Sec.6 Optional class notation surveys — Several requirements related to the DRILL notation have been updated. — DEICE has been removed. — WINTERIZATION and ISDS requirements have been included. — BWM references have been completed — Several notations have been updated by in a large degree referring to the Rules for Ships. Ch.3 Sec.7 Alternative survey arrangements — Alternative survey requirements for drilling equipment have been described. Ch.3 Sec.8 Surveys performed by approved companies — This new section contains existing requirements on service suppliers previously found in Sec.3. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 11 DNV-OSS-201 October 2013 Verification for Compliance with Norwegian Shelf Regulations General — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101” Ch.2 Sec.3 D506 is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6].” — General updating of contents to correctly reflect governing legislation of PSA, NMA and NOROG/NSA guidelines. — Implementation letter from letters from the Petroleum Safety Authority Norway (PSA) to Class Societies 2012-06-26 about additional text to the N-notation. Ch.1 Sec.1 Introduction — Updated definition of AoC in [2.2]. — Updated reference and abbreviation tables in [3.1] and [4.1]. Ch.1 Sec.2 Verification Principles and Class Notations — Updated regulation references in [1.2]. Ch.2 Sec.2 Drilling Unit (N) — Class notation ES (Enhanced Systems) is added as a prerequisite for Drilling Unit (N) in [1.1.1]. — Verification basis for Drilling Unit (N) has been updated in Table 2-1. — Additional technical requirements stipulated by PSA in letter to Class Societies 2012-06-26 have been added in [2.2]. Ch.2. Sec.3 Production and/or Storage Unit (N) — Verification basis for Production Unit (N) in Table 3-1 has been significantly updated to reflect latest PSA Facility regulations guidance on limitations on use of maritime regulations for mobile facilities that are production facilities — Additional technical requirements stipulated by PSA in letter to Class Societies 2012-06-26 have been added in [2.2]. Ch.2 Sec.4 Storage Unit (N) — New section introduced to specifically cover Storage Unit (N). This was previously combined with Production Unit (N). Ch.2 Sec.5 Well Intervention Unit (N) — Class notation ES (Enhanced Systems) is added as a prerequisite for Well Intervention Unit (N) in [1.1.1] — Verification basis for Well Intervention Unit (N) has been updated in Table 5-1. — Additional technical requirements stipulated by PSA in letter to Class Societies 2012-06-26 have been added in [2.2]. Ch.2 Sec.6 Accommodation Unit (N) — Verification basis for Well Intervention Unit (N) has been updated in Table 6-1. — Additional technical requirements stipulated by PSA in letter to Class Societies 2012-06-26 have been added in [2.2]. Ch.2 Sec.7 DRILL(N) — Verification basis for DRILL (N) has been updated in Table 7-1. Ch.2 Sec.8 PROD(N) — Verification basis for PROD (N) has been updated in Table 8-1. Ch.2 Sec.9 WELL(N) — Verification basis for WELL (N) has been updated in Table 9-1. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 12 DNV-OSS-201 (continued) October 2013 Verification for Compliance with Norwegian Shelf Regulations (continued) Ch.2 Sec.11 CRANE(N) — NORSOK R-002 has been added in [2.2.1] as verification basis for CRANE(N) in line with latest amendment of PSA Regulations. Ch.3 Sec.1 General Provisions for Periodical Surveys — New guidance note on evaluation of rule changes introduced in [2.1.1]. App.A Special Considerations for Ageing Offshore Units (Informative) — New informative annex added to inform about PSA's requirements to documentation of ageing units (defined as 19 calendar years). DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 13 2 Changes to DNV Standards Table 3-2 DNV Standards Document number DNV-OS-A101 October 2013 Document title Safety Principles and Arrangements Changes General The document has been updated to be in accordance with the new principles for DNV Offshore Standards for Classification, including: — This document has been split into three chapters of which Ch.2 contains technical requirements. In addition the structure has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101 Ch.2 Sec.3 D506” is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6]”. — Interpretations have been added. — The voluntary ES notation has been defined. — Alignment with IACS, MODU code and other relevant international standards. — Changed sequence of service unit sections to drilling units FPSO - FLNG. Ch.1 Sec.1 (old Sec.1) — [1.4]: Included definition of “interpretations”. — [1.5]: A new sub-section on structure has been added. — [4]: Revised and simplified definitions. Ch.2 Sec.1 (old Sec.2) — Completely rewritten — [3]: Added requirement to establish acceptance criteria. — [4]: Adjusted radiation level at lifeboats to require heat protection from 12.5 to 4.7 kW/m2 to align with radiation requirements generally given. Ch.2 Sec.2 (old Sec.3) — [3]: — Added separation requirements of hazardous and nonhazardous areas including drain — Added requirements of toe board for deck, gangways, and stairways. — Added requirements of the non-use of asbestos. Ch.2 Sec.3 (old Sec.4) — [1]: Restructured scope and objective definitions. — [4]: — Included IACS/ MODU code definitions for hazardous areas. — Added battery installations requirements. Ch.2 Sec.4 (old Sec.5) — Major changes in that Sec.4 will only include general requirements applicable to all offshore units whereas specific requirements related to Drilling Units or FPSOs are now included in Sec.6 and Sec.7 respectively. — [1]: — Objective rewritten to make clear the complementary role of ESD to hazardous areas wrt. ignition control. — Scope description has been included. — Completion application description to make clear the difference of our follow up between basis class and ES. — [2]: Containing basis provisions based on MODU code (with our interpretations. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 14 Table 3-2 DNV Standards (Continued) Document number DNV-OS-A101 (continued) October 2013 Document title Safety Principles and Arrangements (continued) Changes Ch.2 Sec.5 (old Sec.6) — [2] and [4]: — Escape routes are now related to regularly manned areas. — Ref. is made to DNV-OS-D201 related to escape/access for switchboards and capacity requirements for batteries for emergency lighting. — [5]: Revised MODU Code/SOLAS references for marking of units in transit. — [6]: Clarified principles for alarm and alert signals and added reference to DNV-OS-D202 on alarm philosophy. Ch.2 Sec.6 (Old Sec.8) — Clarified that the section is also applicable for well intervention units with return of hydrocarbons. — [3]: Aligned and restructured area hazard classification with IACS. — [4]: As for Sec.7 [4] the same has been done for this section. — Restructured between basis provisions and enhanced ESD system requirements. Ch.2 Sec.7 (Old Sec.7) — [1] and [5]: Clarified principles for units where simultaneous production and tank inspection will apply (in [1]) and added such requirements (in [5]). — [4]: As for Sec.5 this is subjected to a major revision in that all specific requirements for FPSOs are given in this part as opposed to the previous version where too many specific FPSO requirements were given as general requirements. — New figures for ESD overall shutdown hierarchy have been given for both anchored and dynamically units have been included. Ch.2 Sec.8 (Old Sec.9) — [7]: As for Sec.7 [5] a new part has been added for units where simultaneous production and tank inspection will take place. Ch.3 Certification and classification — This chapter is new. Appendices DNV-OS-A201 October 2013 Winterization for Cold Climate Operations (Tentative) — A new App.C has been added on methodology that can be used for ignition source control. General This is a new document. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 15 Table 3-2 DNV Standards (Continued) Document number DNV-OS-C301 October 2013 Document title Stability and Watertight Integrity Changes General — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101 Ch.2 Sec.3 D506” is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6]”. Ch.1 Sec.1 Introduction — [4.2.4] has been amended by adding “or weathertight”. Ch.2 Sec.1 Stability — In [1.1.5] the convention for IMO MODU Code references has been modified. — A note has been added to [4.2.2]. — A note has been added to [5.2.2]. Ch.2 Sec.2 Watertight Integrity, Freeboard and Weathertight Closing Appliances — [10.1.1] has been amended regarding description of waterlines (beach lines). DNV-OS-D101 October 2013 Marine and Machinery Systems and Equipment General The document has been updated to be in accordance with the new principles for DNV Offshore Standards for Classification, including: — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101 Ch.2 Sec.3 D506” is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6]”. — Interpretations have been added. — The voluntary ES notation has been defined. — Alignment with IACS, MODU code and other relevant international standards. Ch.1 General — The chapter has been restructured to clarify objective and scope of the standard. — Definition of Interpretations has been included in Sec.1 [1.3]. Ch.2 Technical Provisions — Restructured detailed rules to make clear their relation to principal requirements. — Updated existing guidance notes to make clear that a follow up is expected. — Requirements for refrigeration system of Sec.1 [1.11] defined under the scope of ES. — Removed previous Sec.5 F Windlasses, Winches and Chain Stoppers for Temporary and Limited Use. Now covered by updated DNV-OS-E301. Ch.3 General — A more extensive description of classification in Sec.1 [1] and an overview of the requirements covered by ES included. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 16 Table 3-2 DNV Standards (Continued) Document number DNV-OS-D201 October 2013 Document title Electrical Installations Changes General The document has been updated to be in accordance with the new principles for DNV Offshore Standards for Classification, including: — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101 Ch.2 Sec.3 D506” is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6]”. — Alignment with IACS, MODU code and other relevant international standards. — Interpretations have been introduced. Ch.1 Introduction — Sec.1 [1.3.1]: Definition of interpretations has been included. — Sec.1 [1.4]: Description of the documents structure as been included. — Sec.1 [4.10.1]: Definitions of switchboards, assemblies, switchgear and controlgear given. Ch.2 Technical provisions — General — Detailed rules have been restructured in order to clarify their relation to principal requirements. — Existing guidance notes have been updated to specify that a follow up is expected. — Sec.1 General — [4.4.2]: The list of Important services has been amended. Among changes: auxiliary boilers in vessels with HFO as the main fuel is regarded as important equipment. — [4.4.3]: The list of Emergency services has been amended. Among changes: navigation and communication system listed as emergency systems. — [4.6.2]: EMC zones have been defined. — Sec.2 System design — Several detailed requirements have been deleted: — in previous D102 on battery charger — in previous H303 Generator instrumentation a) on busbar frequency read-out — in previous I205 on lighting circuits for cargo spaces. — [1.2.2]: Sockets can be accepted for any voltage level. — [2.2.5]: Requirements related to regeneration of power by e.g water milling of propellers are made applicable to all offshore units. — [3.1.1]: Requirements for ventilation of emergency generator room and cooling of emergency generator prime mover have been added. — Table 2-1: Requirement for emergency power for fire fighting system and alarm sounder system has been added. — [6.4]: Limitation for rating of socket outlets for shore connection has been deleted. — [7.1.1]: Requirement for load shedding shall take into account both active and reactive overload. — [7.2.4]: Common short circuit protection is acceptable for non-important consumers and for consumer constituting a functional service group. — [7.2.6]: Requirement to short circuit protection of secondary side of control power transformer has been modified. — [7.4.2]: New requirement for protection of high voltage control transformers. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 17 Table 3-2 DNV Standards (Continued) Document number DNV-OS-D201 (continued) October 2013 Document title Electrical Installations (continued) Changes — [8.1.1]: If one pole or phase of the control voltage source is earthed, the control wiring and interlocks (if any) shall be installed on the non-earthed side of any relay coils. — [8.2.2]: All generator prime movers and generator circuit breakers shall have means for manual operation. — [8.2.4]: A shut down or stop signal to the prime mover shall cause disconnection signal to the generator circuit breaker. — [8.2.5]: Each generator cubicle shall have a separate circuit from the control voltage distribution, with separate short circuit protection. — [8.4.2]: Requirement for local control of motors and motor starters has been added. — Table 2-6: Requirements for minimum cross-section of earth conductor have been updated. — [10.5.4]: Requirements for de-rating of bunched cables have been updated. — [10.8.1]: Tables for Current rating of cables with temperature class 60, 85 and 95 deg. C have been deleted. — Sec.3 Equipment in general — [2.3]: Maximum operational temperature limits have been updated. — [3.1.4]:The possibility for defining EMC zones as given in IEC 60533 has been included. — [4.3.2]: Requirement to cable entrance clarified. — [4.6.1]: Requirement for clearance and creepage distances have been updated. — [7.1]: General type test requirement for equipment has been introduced. — Sec.4 Switchgear and controlgear assemblies — [1.1.8]: Requirements for clearance and creepage distances for low voltage equipment have been modified. — [1.1.9]: Requirements for clearance and creepage distances for high voltage equipment have been moved from Sec.3. — [4.1.3]: Verification requirements for short circuit protection of control power transformers have been introduced, ref changes in Sec.2 [7.2.6]. — [4.1.4]: Requirements for power frequency tests for low voltage switchgears and controlgears given. — Sec.5: Rotating machines — [1.3.1]: Requirements for temperature detectors for propulsion motors have been moved from Sec.12. — [3.1.1]: Test requirements for electrical machines have been updated. — Sec.8: Miscellaneous equipment — [1.3.3]: Requirement to top plate inclination of space heaters has been removed. Installation requirements have been moved to Sec.10. — Sec.9: Cables — [2.3.2]: Minimum conductor cross section of cables rated above 6/10kV has been increased. — [2.6.2]: Requirement for minimum 85 degrees temperature class of protective sheet has been introduced and acceptable insulation materials has been updated. — [6.1.1]: New requirements for data communication cables have been introduced. — [7.1.1]: New requirements for flexible cables have been introduced. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 18 Table 3-2 DNV Standards (Continued) Document number DNV-OS-D201 (continued) October 2013 Document title Electrical Installations (continued) Changes — Sec.10: Installation — Table 10-1: The required IP rating of control desks in dry control rooms may be relaxed. — Table 10-1: IP grade required for instrumentation components in dry control rooms and switchboard rooms is changed from IP 22 to IP20. — [2.7.1]: New requirements to installation of lighting fixture regarding UV resistant cables. — [3.2.2] b): Requirement to 300 mm separation between high voltage cables and low voltage cables is deleted. New requirement in line with IACS UR E11: “High voltage cables are not to be installed on the same cable tray for the cables operating at the nominal system voltage of 1 kV and less”. — [3.3]: Requirements to cable penetrations have been updated. — [3.5.2]: Aluminium cable trays may be accepted. — [3.5.4]: Bending radiuses have been adjusted. — [3.9.4]: Earthing requirements to cable metal covering have been modified. — [4.3.2]: Requirements for electrical tests of high voltage cable after installation have been modified. — [4.4.7]: Mandatory test requirement for harmonic distortion has been introduced. — Sec.11: Hazardous areas installations — Table 11-1: The requirements for documentation of Is-circuit limits and values are clarified. — [3.2.4]: Ex requirement in rooms for refrigerating systems has been introduced. — [3.3.6]: Requirement for earth fault protection in hazardous area for TN-S has been introduced. — Sec.12: Electric propulsion — [1.1.1]: An offshore unit with shaft generator(s) which can be operated in a “power take in” (PTI) mode shall be regarded as having electrical propulsion. — [1.2.1]: The option with only one electrical propulsion motor with to sets of windings has been removed and some other system design requirements for electrical propulsion have been modified. — [1.6.2]: New requirement for fail safe functionality of power plant control system. — [1.6.3]: Monitoring requirements have been updated. — [2.1.1]: Requirements for onboard testing has been changed. Ch.3 Certification and classification — Table 1-2 has been amended. Among the changes: operation modes shall be included in the System philosophy. Calculation of single phase fault against earth shall be included for systems with earthed neutral. — Table 1-3 has been amended. Among the changes: for permanent magnet motors, relevant drawings for assessment of mechanical strength shall be submitted for approval. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 19 Table 3-2 DNV Standards (Continued) Document number DNV-OS-D202 October 2013 Document title Changes Automation, Safety and Telecommunication Systems General The document has been updated to be in accordance with the new principles for DNV Offshore Standards for Classification, including: — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101 Ch.2 Sec.3 D506” is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6]”. — Interpretations have been added. — The standard has been aligned with IACS, MODU code and other relevant international standards. — The standard has been aligned with DNV Rules for Classification of Ships, Pt.4 Ch.9 and the latest insights and experiences. Ch.1 General — The chapter has been restructured to clarify objective and scope of the standard. Ch.1 Sec.1 General — Definition of Interpretations has been included in [1.3]. — Previous A400 has been amended and moved to Ch.2 Sec.3. Ch.2 Sec.1 Design Principles — Previous D (Back up Functions and Emergency Operation) has been removed. — Test descriptions have been updated. Ch.2 Sec.2 System Design — Detailed descriptions on mutual independence in [1.1.3]. — Power distribution requirements of [2] have been updated. Ch.2 Sec.3 System Software — Previous C on serial communication has been deleted. Ch.2 Sec.4 Component Design and Installation — Previous D200 has been deleted since it is covered by DNV-OSD101. Ch.3 General — An overview of the requirements covered by the voluntary ES notation has been included. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 20 Table 3-2 DNV Standards (Continued) Document number DNV-OS-D301 October 2013 Document title Fire Protection Changes General Restructured in accordance with the new principles for DNV Offshore Standards for Classification, including: — alignment with IACS, MODU code and other relevant international standards — interpretations — definition of the voluntary ES notation. Updated to reflect changes in regulatory background (i.e. MODU and FSS code) and latest experiences and insights The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101” Ch.2 Sec.3 D506 is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6].” Ch.1 Sec.1 General — — — — Completed introduction with scope and structure of document. Include definition of Interpretations in [1.3]. Restructured to make more clear objective and scope of standard. Revised definitions and added some, e.g. active fire protection, fire detection area. Ch.2 Technical Provisions Moved unit specific requirements to relevant sections. Ch.2 Sec.2 Active fire protection of specific areas — Revised Table 1-1. Ch.2 Sec.4 Fire and/OR Gas Detection and alarm Systems — Completed restructured section in line with FSS code Ch. 9 for both fire and gas detection systems. — Subsection [3] and [4]: Clarified the intention of R0. — Clarified unconfirmed and confirmed gas detection. Ch.2 Sec.5 Miscellaneous Items — Removed subsection on operational readiness and maintenance Ch.2 Sec.6 Supplementary Requirements for Drilling and Well Intervention Units — Subsection [3]: Added requirements for drill ships. Ch.2 Sec.7 Supplementary Requirements for Oil and Gas Production and/or Storage Units — Subsection [3]: Added requirement for remote stop of fire pumps for units where stability problems may arise to avoid capsizing. Ch.3 Sec.1 Classification — Include a more extensive description of classification in the new sub-section [1] and an overview of requirements covered by ES. Ch.3 Sec.2 Certification of Equipment — Revised general requirements and equipment categorisation to align with practice. Previous Appendix A - “Fixed Fire Fighting Systems” has been deleted. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 21 Table 3-2 DNV Standards (Continued) Document number DNV-OS-E101 October 2013 Document title Drilling Plant Changes General — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101” Ch.2 Sec.3 D506 is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6].” Ch.1 Sec.1 Introduction — API Standard 53 included as normative reference. — Clarification regarding temporary installed equipment. — Including qualification requirements for novel technology/ designs. Ch.2 Sec.1 Design Principles — Changed definitions, use and arrangement of Safety Systems and Drilling Systems (Essential/Important/Non-important). — New sub-section [2.2] regarding well barriers. Previous B200 has been renumbered to [2.3]. Ch.2 Sec.3 Piping — Clarifications regarding flexible hoses. Ch.2 Sec.4 Electrical and Automation/Safety Systems — Clarifications regarding electrical systems. Ch.2 Sec.5 Drilling Systems and Equipment — [3]: New requirements, definitions and clarifications for well control equipment. — [5]: Clarified requirements to drawworks. — [6]: Clarified that this sub-section is also applicable to riser handling. — [8]: New sub-section regarding Managed Pressure Drilling (MPD) systems. Previous H, I and J has been renumbered [9], [10] and [11]. — [10]: Clarified requirements for man-riding equipment. Ch.2 Sec.6 Manufacture, Workmanship and Testing — Previous Sec.7 has been renumbered due to moving of Sec.6 to Appendix A. — Clarified requirements for welding. Ch.3 Sec.3 System and Equipment Certification — Including certification requirements for MPD systems, in addition to some other changes (e.g. Choke and Kill valves are now Category I). App.A Workover and Well Intervention Systems and Equipment — Requirements to workover and well intervention are moved to Appendix A from previous Ch.2 Sec.6. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 22 Table 3-2 DNV Standards (Continued) Document number DNV-OS-E301 October 2013 Document title Position Mooring Changes General — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101” Ch.2 Sec.3 D506 is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6].” Ch.1 Sec.1 General — Minor updates of references. — Included new terms. Ch.2 Sec.1 Environmental Conditions and Loads — Old B202 has been deleted. — [2.2.4] (previous B205): Clarification regarding extreme environmental conditions. — [2.3.4]: Squalls wind speeds are 1 min average. — [2.3.6]: Clarification regarding how to consider squalls in design. — New [2.3.8]: Included that an analysis length of 1 hour is recommended since the duration of squalls is approximately 1 hour. — Old B502, B504, B505, B508 and B509 have been deleted. — Minor changes in [3.1.1], [3.2.1], [3.2.5] and [3.2.8]. — Previous C500 Wave frequency motions moved to Sec.2 [2.3]. — Previous C600 Low frequency motions moved to Sec.2 [2.4]. Ch.2 Sec.2 Mooring System Analysis — [2.1.2] has been rewritten due to new definitions of fibre rope performance. Guidance Note has been deleted. — Old B103 and B104 have been deleted. — Previous B111 now [2.1.9] has been rewritten due to new definitions of fibre rope performance. — Previous B112 now [2.1.10] Amended text: “The change-inlength behaviour of synthetic fibre ropes or tethers has to be verified by testing”. — [2.2.1]: Clarification regarding requirements to document that the chosen calculation program is applicable for the particular anchoring system and on the particular location. New Guidance Note. — New [2.2.2], [2.2.3] and [2.2.4]. — Old B202 now [2.2.5] amended - formula removed. — Old B204 now [2.2.7] extended regarding extreme value distribution. — Old B205 regarding simulation length has been relocated to [2.2.9] — Old B208 now [2.2.11] has been amended. Guidance Note has been deleted. — Old B209, B210 and B211 have been deleted. — New [2.3] and [2.4]. They are previously C500 and C600 in Sec.1. — B300 Floating platform response analysis is now [2.5]. — Old B303 has been amended and is now [2.5.3]. Guidance Note is deleted. — Old B304 and B305 have been deleted. — B400 Mooring line response analysis is now [2.6]. — Old B405 has been deleted. — B500 Characteristic line tension for the ULS is now [2.7]. — B600 Characteristic line tension for the ALS is now [2.8]. — [3.2.3]: Added description for steel wire rope going over fairleads. — Table 2-3: added requirements for tropical waters. — E203: Moved to Ch.2 Sec.4 [9]. — Minor amendment in [6.4.5] and a reference to [6.2.6] have been included. — The expression “tension compression” is changed to “lowtension” in [6.6.2] and [6.6.3]. — Figure 10 in [6.6.4] is deleted. — [8]: Reference /9/ is deleted. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 23 Table 3-2 DNV Standards (Continued) Document number DNV-OS-E301 (continued) October 2013 Document title Changes Position Mooring (continued) Ch.2 Sec.3 Thruster Assisted Mooring — New class notations have been added: TAR and ATAR. — The section has been harmonised with Rules for Classification of Ships Pt.6 Ch.7 Dynamic Positioning Systems with respect to power and control systems. Redundancy requirements has been amended. — In [4.2.1] the power systems with and without redundancy have been directly attached to the DYNPOS notation requirements. — Previous D202 to D206 have been deleted. — [4.3.1] and [4.3.2] regarding control systems have been amended. — Previous D400 Manual thruster control has been deleted. — Previous D500 Remote thrust control, joystick system has been deleted. — Previous D600 will now be [4.4]. — Previous D602 now [4.4.2] with new wording: “A mode selector shall be arranged in the thruster control position to enable switching between manual and automatic thruster control”. — Previous D603 now [4.4.3] which specify that if redundancy is required the control system shall comply with DYNPOS-AUTR, else DYNPOS-AUT. — Previous D800 is now [4.5] and have been amended by removing previous D805, D808, D809, D809, D810, D811 and D812. — Previous D900 is now [4.6]. — Previous D1000 Simulation is now [4.7]. — Previous D1100 Logging is now [4.8]. — Previous D1200 Self-monitoring is now [4.9]. — Previous F101 has been amended by [5.1.1] new wording: “Thrusters shall be certified as thrusters for dynamic positioning if not used for propulsion of the vessel”. Ch.2 Sec.4 Mooring Equipment — [2]: Removed “For anchors” in heading. — [2.1.3]: Clarification regarding loads to apply on turret structures. — Previous B200: Moved to new section [3.3]. — [9]: New section 9.2 (moved from previous Ch.2 Sec.4 N). — [10.1.1] changed to: “Technical requirements for offshore mooring fibre ropes and tethers are given in DNV-OS-E303”. — [10.1.2] the word “rotation” changed to “twisting”. Updated Guidance Note. — New [10.2] Operation. — New [10.2.1]: “Requirements to operation of offshore mooring fibre ropes and tethers are found in DNV-OS-E303.” — Old J200 is now [10.3]. — [10.3.1] changed to: “Documentation requirements for offshore mooring fibre ropes and tethers are given in DNV-OS-E303”. — Old J202, J203, J204, J205 and J206 are deleted. — [11.5]: Title changed. — [11.5.2]: Specified wire layer to be used for dimensioning winch brake. — [11.5.9]: Added requirement to max speed during emergency release. — [11.5.12]: New paragraph with requirement to deluge. — [11.9]: New section (moved from previous Ch.2 Sec.4 L). — [12]: New section regarding winches for pull-in of mooring and riser systems. — [13.3.4]: Added requirement to DFF to be used in long term (permanent) mooring. — [14.1.1]: Changed requirement for line tension recording from 24 h to 30 days. — [18]: New section regarding bearings. Ch.2 Sec.5 Tests — Table 5-1: The table has been amended by: - adding a note regarding stalling - additional test requirements on control system. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 24 Table 3-2 DNV Standards (Continued) Document number DNV-OS-E301 (continued) October 2013 Document title Changes Position Mooring (continued) Ch.3 Sec.1 Certification and Classification — Previous D300: Deleted as requirement belongs in OSS. — The wording in first paragraph of [4.5.2] is changed. Ch.3 Sec.2 Equipment Selection and Certification — [7.1.2] has been extended. — [7.2] heading changed to Condition Management — [7.2.1], the wording fibre rope assemblies are changed to offshore mooring fibre lines. Reference to Ch.2 Sec.2 has been deleted. — [7.2.2], the wording in service condition assessment scheme is changed to condition management program. — Previous G203 has been deleted. App.A Required Documentation DNV-OS-E302 October 2013 Offshore Mooring Chain — The wording in [A.1.3.6] has been changed. General — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101” Ch.2 Sec.3 D506 is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6].” — Reference to Purchaser where Purchaser agreement is referred to has been deleted. Ch.1 Sec.1 Introduction — Table 1-1: New references. — [3.1.4]: DNV referenced in definition. Ch.2 Sec.1 Materials — [1.6.1]: Level II requirement to NDT operators. — [3.4.2] and [4.4.2]: Option to use oil has been included. — [3.7.1]: Allowable grinding depth on machined surfaces has been specified. Ch.2 Sec.2 Mooring Chain Cables and Accessories — [2.5.3]: Deleted requirement to check furnace temperature uniformity when change of chain size. — [2.9.1]: Requirement to accuracy of measurements has been introduced. — [2.9.4]: Change of areas to be measured and acceptance criteria. — [2.10.3]: Requirement to use of fluorescent MT has been added. — [2.10.4]: Open up for use of Phased Array added in the Guidance note. — [2.11.3]: Allowable temperature has been changed. — [3.7.3]: Clarification in extent of NDT. — [3.7.4]: A new Note has been added clarifying UT requirements. — [3.8.1]: Allowable grinding depth on machined surfaces has been specified. — Table 2-3: A new Note 4 has been added. Ch.3 Sec.1 Certification and Classification - Requirements — [2.4]: List of procedures for approval has been added. — [2.6]: Content of material certificates has been clarified. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 25 Table 3-2 DNV Standards (Continued) Document number DNV-OS-E304 October 2013 Document title Changes Offshore Mooring Steel Wire General Ropes — The structure of this document has been converted to decimal numbering. Older references to this document may normally be interpreted by analogy to this example: — “DNV-OSS-101” Ch.2 Sec.3 D506 is now “DNV-OSS-101 Ch.2 Sec.3 [4.5.6].” Ch.1 Introduction — Sec.1 Table 1-1: Some international standards that are listed as applicable references have been replaced or withdrawn. Ch.2 Technical Provisions — Sec.2 [2.2.1], [2.4.3], [3.5.1]-[3.5.2], Sec.4 [2.1.4]: Some international standards that are listed as applicable references have been replaced or withdrawn. — Sec.5 Figure 5-1: The figure showing the material samples location in the socket have been improved. — Sec.5 [2.4.2] and [3.2.3]: Text have been added. — Sec.7: “and towing” has been deleted from section title and Sec.7 [1.1.1]. — Sec.7 [1.2.3]: The term lay has been replaced by the term spinning. Ch.3 Certification and Classification — Sec.1 [2.5.2]: Added requirement that min 5% of the wires shall be individually tested with DNV Surveyor. — Sec.1 B702 “Materials for wires shall be delivered with the manufacturer’s certificates or test reports” has been deleted. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 26 Table 3-2 DNV Standards (Continued) Document number DNV-OS-F101 October 2013 Document title Changes Submarine Pipeline Systems General — Excessive conservatism related to fracture assessment of girth welds has been removed in Appendix A leading to: — relaxation of weld repair requirements — increased installation speed. — Other changes: — reference list updated. — general update based upon feed-back from industry. Sec.4 Design - Loads — G407: Clarify effect of selecting larger positive tolerances. Sec.5 Design – Limit State Criteria — C402: Minimum wall thickness requirement re-worded to avoid misinterpretations. — E1100: Pipe-in-pipe and bundles moved from G200. — Equation 5.6 corrected — F107: Clarifications on code break. Sec.7 Construction – Linepipe — E104: Implications of reduction in mill test pressure clarified. — I400: Table 7-26: Amended by adding t = 15 mm step for HFW pipes. Sec.10 Construction – Offshore — J307: Pressure test accuracy requirement modified. Appendix A Fracture Limit State of Girth Welds — General clarifications based on comments from industry. — The terms 'defect', 'flaw' and 'notch' have been defined. — The Lr cut-off formula for strain based loading has been amended by adding limit. The Lr cut-off value shall not exceed 1.5. — Table A-7 for assessment of surface breaking flaws has been amended. Appendix D Non-Destructive Testing (NDT) — B212: Digital Radiography reference updated to ISO 17636-2. DET NORSKE VERITAS AS DNV Service Documents , October 2013 Sec.3 Summary of Changes – Page 27 3 Changes to DNV Recommended Practices Table 3-3 DNV Recommended Practices Document number DNV-RP-A205 October 2013 Document title Changes Offshore Classification Projects - Testing and Commissioning General — Spelling, grammar and punctuation have been amended. — The use of abbreviations has been standardized and [1.8] Abbreviations has been expanded. — References to renumbered documents have been updated. Sec.6 Safety, health and environment — A new Sec.6 on SHE has been added. Appendices DNV-RP-D202 October 2013 Witnessing of Low Sulphur Fuel Changeover and Operations — Previous App.A.6 has been deleted. — There have been minor updates to App.A, App.B and App.C. — In App.D and App.E survey categorisation has been developed for FPSO and FSO (previously marked “Pending”). — Survey scope for the Class Notation PROD has been developed in App.G.2. This is a new document. DET NORSKE VERITAS AS
© Copyright 2026 Paperzz