12535 PIR TIMER 376A-1 INSTRUCTIONS AW_Layout 1 29/04/2013 10:33 Page 1 pirtimer energysense pirsensor fitting and operating instructions pirtimer energysense pirtimer fitting & operating instructions pirtimer - two wire Product: 376A-1, 376A-2, 770A-1, 570A-3, 570A-4 Two wire Rating at 240V ac • Incandescent 16A • Compact Fluorescent 16A • Fluorescent 16A • Time Delay 2min - 2h The PIR timer is part of the Elkay family of switches, timers and detectors which save energy and increase convenience in and around your home, garden or premises. Usage The PIR timer has been designed to replace a single gang light switch, to control lighting and some heating and ventilation systems, please contact the Elkay technical team for advice on suitability. The unit is switched on by the detection of moving body heat within a specific range. When body heat is no longer detected, the unit will switch off after the adjustable time period has elapsed. If moving body heat is detected again during the timing period, the timing sequence will restart. The unit has a lux level adjustment, which prevents lighting being switched on when there is sufficient light levels in the room. Your Elkay timer has the added benefit of a manual override facility. This allows the lights to be turned on for the set period of time when the ambient level is such that the lights would not usually come on. In dark conditions the manual override disables the PIR allowing the lights to be turned off indefinitely or when the override switch is re-pressed. WHEN USED WITH SOME LOW WATTAGE LIGHTING, HEATING AND VENTILATION CIRCUITS PLEASE ENSURE A CAPACITOR OF 2 MICROFARADS (MINIMUM) IS FITTED. SUPPLIES OF SUITABLE ELKAY CAPACITORS CAN BE FOUND AT YOUR STOCKIST (REF PFCC-1). DO NOT USE WITH CONTACTORS. For further wiring diagrams and more information on our products please visit our website on www. elkay.co.uk IMPORTANT NOTICE All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008. TECHNICAL HELPLINE For further help or assistance or information on this or other products in the range please call the Elkay Technical team on 01675 468222. Please call the Technical helpline before returning any products to your stockist. In the unlikely event that you have to return your product please ensure you switch the battery off first. Elkay Electrical, Coleshill, Birmingham, England. Tel: +44 (0) 1675 468222 www.elkay.co.uk IMPORTANT Please note that it is essential that the live in and live out are identified prior to commencing the installation and steps 1 – 3 are followed precisely. No neutral is required on this product (See diagram 1). Do not install the switch timer with the mains power on as this can damage the product. LIVE IN NEUTRAL LIVE OUT Battery Lux level adjustment 4. 3. 2. 1. DIL switches Diagram 1 Wiring diagram for a single unit master. NOT SUITABLE FOR USE WITH CONTACTORS. DO NOT MEGGER TEST OR INSULATION RESISTANCE TEST THIS PRODUCT. REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING. Your Elkay unit is compatible with a single gang, 25mm deep British Standard accessory plate. Please ensure that the top and bottom lugs are removed from metal wall boxes prior to fitting. For 16mm boxes Elkay provide a spacer plate (product code220A-1) to take box depth to 25mm. For two way lighting (see diagram 2), you will require a slave. Please note it is not possible to use two 2 wire masters in the same circuit. IMPORTANT NOTICE All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008. Call +44 (0) 1675 468222 or click www.elkay.co.uk 12535 PIR TIMER 376A-1 INSTRUCTIONS AW_Layout 1 29/04/2013 10:33 Page 3 pirtimer energysense energysense pirsensor fitting and operating instructions Diagram 2 Positioning Use the detection range to determine a suitable location for the sensor. Avoid subjecting to direct sunlight, not adjacent to the load, vibrating surfaces or near forced air heating and ventillation. Please note that the trigger terminal is the third terminal. Wiring diagram for a Master and Slave. LIVE IN NEUTRAL the red LED will flash rapidly to indicate the PIR has been disabled and will switch the lights off after 1 minute, please note blue locator neon will be on and the red neon will be flashing. To re activate press lens (as shown in diagram 5). Installation Notes If the mains power has not been applied and the PIR lens has been pressed the blue locator ring will flash once. The unit will then revert to rapidly flashing and the initialising sequence steps above must be repeated. LIVE OUT This product requires a 24 hour power supply. The battery inside the unit recharges when the light source or appliance is switched OFF. Where the supply may be interrupted or isolated regularly we must recommend our products from the three wire range. Battery Lux level adjustment 4. 3. 2. 1. DIL switches From the rapid flashing mode, if the installation sequence is not complete as per instructions the unit will revert to sleep mode after a period of 5 minutes. To re activate press until it clicks and hold the PIR lens for approximately 20 seconds. Installation Steps DO NOT APPLY MAINS UNTIL INSTRUCTED! Step 1 - Ensure the mains power to the circuit is switched off. Place the previously identified live in wire as per diagram, into the terminal marked L In, the switched live out into the terminal marked L out (see diagram 1). Diagram 3 4 - 6m Step 2 - Set the timing as per timing table (see diagram 4). The black square illustrates where the dip switch should be situated. For example 10min 1 = OFF, 2 = ON, 3 = OFF, 4 = ON. Step 3 - When initialising rotate lux level to maximum (+). Step 4 - Switch on battery (dip switch 4) - you will notice a red flashing LED light on the front of the unit (flashing rapidly). Attach the unit to the wall with the screws provided then clip the front fascia plate. The red flashing LED will change to a single bright flash every 2.5 seconds. RE APPLY MAINS supply, the unit will default your load to the ON condition. (DO NOT PRESS FRONT OF LENS) Press and hold the lens using thumb and fore finger as shown in diagram 5 until it clicks and keep it held down until blue locator ring appears. Your light or appliance will now be switched off. Please leave for 5 minutes to allow the unit to initialize. 5 - 7m 3 - 4m plan view Step 5 - Reduce lux level to sufficient level by rotating clockwise towards (-) if required. (-) represents 0 lux level. 5 - 7m side view Diagram 4 - time settings Operation of the Unit 1. In standard operation, the PIR will now sense body heat when passing through the detection zone. Each time the PIR is triggered the red LED will light and rest back to the start of the timing period. The unit will then wait 20 seconds approximately before allowing the PIR unit to sense and re-trigger the timing period again. 2. If no one is present in the room or the detection zone is not passed through during its set time period, the timer will time out, turning the lights or appliance off and the blue locator ring will light up 3. The PIR unit will only trigger the lights or appliance if the ambient light level is below that set on the lux level adjustment potentiometer. See diagram 1 for location of potentiometer (lux level adjustment). 4. When the ambient light level is sufficient the override switch (pressing the lens as shown in diagram 5) can be used to turn on the lights for the set period of time. This can be used when additional light is required in the room. 5. To override the PIR switch which disables the PIR operation, which leaves the lights turned off indefinitely. This can be done by pressing the PIR lens (as shown in picture above), In case of a power failure, your Elkay PIR timer will attempt to automatically re-start, which will cause the blue locator ring to flash. The unit will attempt to locate the power source for a total of 5 minutes. Each recovery attempt will increase by a minute each time. This will be repeated 25 times before the unit will power down to sleep mode. During this time, pressing and holding the PIR lens for approximately 20/30 seconds will initiate a further recovery attempt. Outdoor Installation (on the 570 range only) Please note only products in the Elkay energy outdoor range are suitable for use outdoors. Elkay energy outdoor can only be used in conjunction with the surface mount box supplied. Take the surface mount box and remove the knock out section. If required and to ensure IP66 waterproof rating, please use a suitable M20 cable gland and use appropriate sealing washers. Mount the surface mount box on a secure surface using the mounting pack supplied. Place screw cover seals over the mounting screws. It is essential that the correct IP66 rated connections are made to keep the IP66 rating of the back box. Steel wire armored connections without seals are not appropriate. Turn off mains supply before proceeding with installation - Install as per previous remote installation instructions - Mount unit onto surface mount box using the fixing screws at all four corners ensuring even connection with the seal - Place screw hole seals over left and right screw cavities - Clip on front fascia plate Re-instate mains supply. Please note that the black bar denotes the position of the dip switch. 20 mins 2. 1. 2. 1. 40 mins Elkay Electrical, Coleshill, Birmingham, England. Tel: +44 (0) 1675 468222 www.elkay.co.uk 4. 3. 2. 1. 60 mins 4. 3. 2. 1. 90 mins DIP 3. DIP 4. DIP 3. ON 1. 10 mins 4. ON 2. DIP 3. ON 1. 5 mins 4. ON 2. DIP 3. ON 1. 2 mins 4. ON ON 2. DIP 3. ON DIP 4. DIP For further wiring diagrams and more information on our products please visit our website on www. elkay.co.uk 4. 3. 2. 1. 120 mins IMPORTANT NOTICE All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008. TECHNICAL HELPLINE For further help or assistance or information on this or other products in the range please call the Elkay Technical team on 01675 468222. Please call the Technical helpline before returning any products to your stockist. In the unlikely event that you have to return your product please ensure you switch the battery off first. Call +44 (0) 1675 468222 or click www.elkay.co.uk
© Copyright 2026 Paperzz