Instruction Manual for MCCB Type KN630-HE Please retain this manual for future reference. ! Handling precautions Caution Electrical work should only be undertaken by suitably qualified persons. The Manufacturer assumes no responsibility for damages resulting from non-application or incorrect application of the instructions provided herein. 1 ! ! Be careful to prevent foreign objects (debris, concrete powder, iron powder etc.) and rainwater from entering product. Safety Notices Be sure to read these instructions and other documents accompanying the product thoroughly before mounting, using, servicing or inspecting the product. In these instructions, safety notices are divided into "Warning" and "Caution" according to the hazard level. For 4-pole breakers, be sure to connect a nautral conductor to the N pole. Otherwise, an over-current may hinder the product from tripping thus resulting in a fire. ! CAUTION : A caution notice with this symbol indicates that neglecting the suggested procedure or practice could result in moderate or slight personal injury and/or property damage. Maintenance precautions When connecting cable or busbar to the product, tighten terminal screws to the torque specified in this manual. insul. tubes or insul. tape interpole barriers CAUTION Note that failing to observe notices could result in serious injury and/or property damage in some instances. Because safety notices contain important information, be sure to read and observe them. ! For front connected breakers, insulate all bare conductors of the line side until the breaker end. If interpole barriers are packed, be sure to use the barriers, moreover, insulate all bare conductors by insulating tape the like so that the tape overlaps with the barriers. Mounting Precautions For detailed mounting dimensions, refer to either the Loadline or System Loadbank catalogues. Caution When the breaker trips open automatically, remove the cause, then return the handle to the ON position. should a fault be interrupted, the breaker must be inspected. Prior to commencing any work on the product, open an upstream circuit breaker or isolator to ensure that no voltage is applied to the product. Otherwise electrical shock may result. ! WARNING : A warning notice with this symbol indicates that neglecting the suggested procedure or practice could result in moderate or slight personal injury and/or property damage. Warning Do not touch the handle catch. Doing so may cause personal injury. Do not place the product in an area that is subject to high temperature, high humidity, excessive dusty air, corrosive gas, strong vibration and shock, or under unusual conditions. . . . .. ! Caution Service and/or inspection of the product must be done by persons heving expert knowledge. Prior to commencing any work on the product, open an upstream circuit breaker or isolator to ensure that no voltage is applied to the product. Otherwise electrical shock may result. Regularly check that the breaker terminal screws are tightened to torque values shown within this manual, failure to do so may result in fire. Other precautions Do not carry this product by accessory leads, as this may cause damage to the product. Do not block the arc gas vents of the product to ensure edequate arc space. Blocking these vents could result in failure of circuit interruption. Unauthorised opening of breaker cover will invalidate product warranty. KON AR-Niskonaponske sklopke i prekida i d.o.o. p.p.209; 10002 ZAGREB, CROATIA Tel: +385 1 236 92 62 Fax: +385 1 233 95 77 e-mail: [email protected] [email protected] 2 B53128 3 Packaged Items / Assembly Tools 4 Operating Instructions Fitting Internal Accessories Instruction Manual Breaker Auxiliary Switch Interpole Barrier M Type TRIPPED (only FC) T2AX00M 3P: 2 pcs. 4P: 3 pcs. tip M B Type * T2AX00B * Ring mark Alarm Switch M Type T2AL00M Handle Shunt trip T2SH00 * ON Type 630A OFF Auxiliary Switch B Type * T2AL00B a kontakt b kontakt a kontakt b kontakt 11/AXc-14/AXa 11/AXc-12/AXb 91/ALc 91/ALc 21/AXc-24/AXa 21/AXc-22/AXb 31/AXc-34/AXa 31/AXc-32/AXb 94/ALa 92/ALb Undervoltage trip T2UV00 * 10mm *Symbols of Accesories Shunt trip Power Source C1-C2 Connections/Poles Qty. Front Connected (FC) Rear Connected (RC) Plug in Connected 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 6 8 4 4 6 8 4 4 4 4 Trip Button OFF Combination (M10x30) Removal (ON) (M6x100) (M12x35) (OFF) (M6x100) RESET (M6x120) (ON) Slits of pulling out leads (OFF) Operation 17 19 8 OFF-ON ON-OFF TRIP-OFF Operation effort 110N 115N 125N In case of fitting one (or two) auxiliary switch, fit in an order from left side slot. AX AL SH UV Alarm Switch * V After fittin, verify the function of the Accessories. Undervoltage trip Power Source D1-D2 6 Conductor connection procedure for RC 5 Breaker mounting procedure for FC / RC 7 Conductor connection procedure for FC 19 D 8 N oC B P Q 8 B 8 oK oO Flat bar stud 19 J M *: 3 or 4 poles B C D A A M10x20 18.6~29.4 Nm 13mm M12x35 40.2~65.7Nm 9 8 Plug in mounting block mounting procedure < 30mm = < 12.5mm = I J K L M N O M6x100 6.0~7.4Nm *: 3 or 4 poles 10.5 mm <= 30 mm < 12 mm = < 12 mm = P 11 mm 10 Rated current for PM Conductor connection procedure for PM Flat bar P 8 11 Drilling plan Y Y Maximum rated current for PM is 535,5A oU V S T U V R M5x30 3.6~4.4Nm Temperature 30oC 40oC 50oC 55oC 60oC 65oC <= 30 mm <= 20mm 11 mm W <= 20 mm M10 18.6~29.4Nm procedure 14 Terminal cover mounting Rated current 535.5A 535.5A 504.0A 396.9A 396.9A 396.9A X X Y 13 Interpole barrier mounting 12 Breaker mounting procedure for PM Y Maximum rated current in each temperature refer to the following list: 17 T R Y Y Y W oU Q Insulate all bare conductors of the line side until the breaker end. M10x30 13.7~22.5Nm M12x40 40.2~65.7Nm Panel cut-out FC RC 16 Adjustable electronic type 15 Handle holder / Lock mounting procedure procedure Electronic type Char. R 0.8 0.9 4 0.95 1 0.63 5 6 3 2 0.5 0.4 1 (OFF) Optional Ground fault trip ON/OFF switch Handle holder / Lock ON or OFF (OFF) 17 Time/Current characteristic curves Electronic type Adjustable R 0.4,0.5,0.63,0.8,0.9,0.95,1 (x n) ( A) Interpole barrier *: 3 or 4 poles (ON) 6 Terminal cover lock 5 4 * Connection 1 2 Terminal cover FC (without flat bar) 5,6 max x 3 (o5~8) 0.2S 0.1S RC (with flat bar) X When removing, remove the items in reverse order of mounting. X Handle holder / lock can be fitted in any position of ON and OFF. RC/ PM M6x120 6.0~7.4Nm *: 3 or 4 poles When removing, remove the items in reverse order of mounting. 3 When removing, remove the items in reverse order of mounting. When you use this item as the handle lock, please fit padlocks in the procedure of 2.5 When removing, remove the items in reverse order of mounting. 3 1,2 4 . 5 8 14 x R Under bar is default setting!
© Copyright 2025 Paperzz