40ch DWDM Multiplexer, 19” 1HU Overview Optical filter are passive multiplexer devices which split or combine the light of several wavelength. These components form the heart of any WDM System. The extremely flexible concept permits many combinations to realize an optimized solution to meet every customer demand. The matched DWDM filter dovetail into each other and permit a seamless migration path while maintaining low first-in costs. In combination with the MICROSENS active transponder modules a highly flexible system WDM is realized. MICROSENS optical filters combine multiplexer and demultiplexer on a common module. All filter are delivered with LC connectors to match the SFP cable types. Optical parameters Parameters Condition Specs Min Number of Channels 100GHz Cha. Center Wavelength ITU frequency. Clear Channel Passband -1 dB Channel Bandwidth -3 dB Channel Bandwidth Optical Insertion Loss at ITU grid Adjacent Channel Isolation Non-Adjacent, Channel Isolation Total Channel Isolation Insertion Loss Uniformity Insertion Loss Ripple Optical Return loss Polarization Dependent Loss in Clear Channel Band Polarization Mode Dispersion Maximum range of the wavelength error of all channels and temperatures in average polarization. Clear channel bandwidth defined by passband shape. For each channel Units Clear channel bandwidth defined by passband shape. For each channel Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations. Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the adjacent channels. Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the nonadjacent channels. Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port Input & output ports 100 GHz C –band nm ±0.1 nm ±0.05 nm 0.24 nm 0.43 nm 3.5 5.0 dB 25 dB 29 dB 22 dB 0.8 1.5 dB 1.5 dB 40 Worst-case value measured in ITU band dB 0.3 Maximum Optical Power Mux/Demux input/ output Monitoring range Max 40 Number Channel Spacing Wavelength Stability Type -35 Table 1: MS419880 Optical characteristic. 0.5 dB 0.5 ps 23 dBm +23 dBm Parameters Condition Specs Min Number of Channels 100GHz Cha. Center Wavelength ITU frequency. Clear Channel Passband -1 dB Channel Bandwidth -3 dB Channel Bandwidth Optical Insertion Loss at ITU grid Optical Insertion Loss at 5% tap monitor port Adjacent Channel Isolation Non-Adjacent, Channel Isolation Total Channel Isolation Insertion Loss Uniformity Insertion Loss Ripple Optical Return loss Polarization Dependent Loss in Clear Channel Band Polarization Mode Dispersion Maximum range of the wavelength error of all channels and temperatures in average polarization. Clear channel bandwidth defined by passband shape. For each channel Units Clear channel bandwidth defined by passband shape. For each channel Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations. Input & output ports nm ±0.1 nm ±0.05 nm 0.43 nm Demux Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the nonadjacent channels. Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port GHz nm Mux Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the adjacent channels. 100 C –band 0.24 3.5 5.0 dB 18.5 21.5 dB 15 16.5 dB 25 dB 29 dB 22 dB 0.8 1.5 dB 1.5 dB 40 Worst-case value measured in ITU band dB 0.3 Maximum Optical Power Mux/Demux input/ output Monitoring range Max 40 Number Channel Spacing Wavelength Stability Type -35 Table 2: MS419881 Optical characteristic. 0.5 dB 0.5 ps 23 dBm +23 dBm Wavelength Plan Ch. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 C59 C58 C57 C56 C55 C54 C53 C52 C51 C50 C49 C48 C47 C46 C45 C44 C43 C42 C41 C40 Freq (THz) WL (nm) 195.90 195.80 195.70 195.60 195.50 195.40 195.30 195.20 195.10 195.00 194.90 194.80 194.70 194.60 194.50 194.40 194.30 194.20 194.10 194.00 1530.334 1531.116 1531.898 1532.681 1533.465 1534.250 1535.036 1535.822 1536.609 1537.397 1538.186 1538.976 1539.766 1540.557 1541.349 1542.142 1542.936 1543.730 1544.526 1545.322 Ch. No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 C39 C38 C37 C36 C35 C34 C33 C32 C31 C30 C29 C28 C27 C26 C25 C24 C23 C22 C21 C20 Freq (THz) WL (nm) 193.90 193.80 193.70 193.60 193.50 193.40 193.30 193.20 193.10 193.00 192.90 192.80 192.70 192.60 192.50 192.40 192.30 192.20 192.10 192.00 1546.119 1546.917 1547.715 1548.515 1549.315 1550.116 1550.918 1551.721 1552.524 1553.329 1554.134 1554.940 1555.747 1556.555 1557.363 1558.173 1558.983 1559.794 1560.606 1561.419 Table 3: MS419880 – wavelengths‘ plan. Ch. No. Freq (THz) WL (nm) Ch. No. Freq (THz) WL (nm) 1 C21 192.10 1560.606 21 C41 194.10 1544.526 2 C22 192.20 1559.794 22 C42 194.20 1543.730 3 C23 192.30 1558.983 23 C43 194.30 1542.936 4 C24 192.40 1558.173 24 C44 194.40 1542.142 5 C25 192.50 1557.363 25 C45 194.50 1541.349 6 C26 192.60 1556.555 26 C46 194.60 1540.557 7 C27 192.70 1555.747 27 C47 194.70 1539.766 8 C28 192.80 1554.940 28 C48 194.80 1538.976 9 C29 192.90 1554.134 29 C49 194.90 1538.186 10 C30 193.00 1553.329 30 C50 195.00 1537.397 11 C31 193.10 1552.524 31 C51 195.10 1536.609 12 C32 193.20 1551.721 32 C52 195.20 1535.822 13 C33 193.30 1550.918 33 C53 195.30 1535.036 14 C34 193.40 1550.116 34 C54 195.40 1534.250 15 C35 193.50 1549.315 35 C55 195.50 1533.465 16 C36 193.60 1548.515 36 C56 195.60 1532.681 17 C37 193.70 1547.715 37 C57 195.70 1531.898 18 C38 193.80 1546.917 38 C58 195.80 1531.116 19 C39 193.90 1546.119 39 C59 195.90 1530.334 20 C40 194.00 1545.322 40 C60 196.00 1529.553 Table 4: MS419881 – wavelengths‘ plan. Dimensions Order Information Art. No. Description Modules MS419880 40 Channel AAWG MUX/DEMUX DWDM 19" 1U, Local: 40x LC/PC duplex, Line: 1x LC/PC duplex, 100GHz Grid MS419881 40 Channel AWG MUX/DEMUX DWDM 19" 1U with 5% Tap, Local: 40x LC/PC duplex, Line: 1x LC/PC duplex, Tap: 1x LC/PC duplex, 100GHz Grid MICROSENS reserves the right to make any changes without further notice to any product to improve reliability, function or design. MICROSENS does not assume any liability arising out of the application or use of any product. pp/3316
© Copyright 2026 Paperzz