Datasheet - Microsens

40ch DWDM Multiplexer,
19” 1HU
Overview
Optical filter are passive multiplexer devices which split or combine the light of several
wavelength. These components form the heart of any WDM System.
The extremely flexible concept permits many combinations to realize an optimized
solution to meet every customer demand. The matched DWDM filter dovetail into each
other and permit a seamless migration path while maintaining low first-in costs.
In combination with the MICROSENS active transponder modules a highly flexible system
WDM is realized. MICROSENS optical filters combine multiplexer and demultiplexer on a
common module.
All filter are delivered with LC connectors to match the SFP cable types.
Optical parameters
Parameters
Condition
Specs
Min
Number of Channels
100GHz
Cha. Center Wavelength
ITU frequency.
Clear Channel Passband
-1 dB Channel Bandwidth
-3 dB Channel Bandwidth
Optical Insertion Loss at
ITU grid
Adjacent Channel
Isolation
Non-Adjacent, Channel
Isolation
Total Channel Isolation
Insertion Loss Uniformity
Insertion Loss Ripple
Optical Return loss
Polarization Dependent
Loss in Clear Channel
Band
Polarization Mode
Dispersion
Maximum range of the wavelength error of all
channels and temperatures in average
polarization.
Clear channel bandwidth defined by passband
shape. For each channel
Units
Clear channel bandwidth defined by passband
shape. For each channel
Defined as the minimum transmission at ITU
wavelength for all channels. For each channel,
at all temperatures and polarizations.
Insertion loss difference from the mean
transmission at the ITU grid wavelength to the
highest power, all polarizations, within the ITU
band of the adjacent channels.
Insertion loss difference from the mean
transmission at the ITU grid wavelength to the
highest power, all polarizations, within the ITU
band of the nonadjacent channels.
Total cumulative insertion loss difference from
the mean transmission at the ITU grid
wavelength to the highest power, all
polarizations, within the ITU band of all other
channels, including adjacent channels.
Maximum range of the insertion loss variation
within ITU across all channels, polarizations and
temperatures.
Any maxima and any minima of optical loss
across ITU band, excluding boundary points,
for each channel at each port
Input & output ports
100
GHz
C –band
nm
±0.1
nm
±0.05
nm
0.24
nm
0.43
nm
3.5
5.0
dB
25
dB
29
dB
22
dB
0.8
1.5
dB
1.5
dB
40
Worst-case value measured in ITU band
dB
0.3
Maximum Optical Power
Mux/Demux input/ output
Monitoring range
Max
40
Number Channel Spacing
Wavelength Stability
Type
-35
Table 1: MS419880 Optical characteristic.
0.5
dB
0.5
ps
23
dBm
+23
dBm
Parameters
Condition
Specs
Min
Number of Channels
100GHz
Cha. Center Wavelength
ITU frequency.
Clear Channel Passband
-1 dB Channel Bandwidth
-3 dB Channel Bandwidth
Optical Insertion Loss at
ITU grid
Optical Insertion Loss at
5% tap monitor port
Adjacent Channel
Isolation
Non-Adjacent, Channel
Isolation
Total Channel Isolation
Insertion Loss Uniformity
Insertion Loss Ripple
Optical Return loss
Polarization Dependent
Loss in Clear Channel
Band
Polarization Mode
Dispersion
Maximum range of the wavelength error of all
channels and temperatures in average
polarization.
Clear channel bandwidth defined by passband
shape. For each channel
Units
Clear channel bandwidth defined by passband
shape. For each channel
Defined as the minimum transmission at ITU
wavelength for all channels. For each channel,
at all temperatures and polarizations.
Input & output ports
nm
±0.1
nm
±0.05
nm
0.43
nm
Demux
Insertion loss difference from the mean
transmission at the ITU grid wavelength to the
highest power, all polarizations, within the ITU
band of the nonadjacent channels.
Total cumulative insertion loss difference from
the mean transmission at the ITU grid
wavelength to the highest power, all
polarizations, within the ITU band of all other
channels, including adjacent channels.
Maximum range of the insertion loss variation
within ITU across all channels, polarizations and
temperatures.
Any maxima and any minima of optical loss
across ITU band, excluding boundary points,
for each channel at each port
GHz
nm
Mux
Insertion loss difference from the mean
transmission at the ITU grid wavelength to the
highest power, all polarizations, within the ITU
band of the adjacent channels.
100
C –band
0.24
3.5
5.0
dB
18.5
21.5
dB
15
16.5
dB
25
dB
29
dB
22
dB
0.8
1.5
dB
1.5
dB
40
Worst-case value measured in ITU band
dB
0.3
Maximum Optical Power
Mux/Demux input/ output
Monitoring range
Max
40
Number Channel Spacing
Wavelength Stability
Type
-35
Table 2: MS419881 Optical characteristic.
0.5
dB
0.5
ps
23
dBm
+23
dBm
Wavelength Plan
Ch. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
C59
C58
C57
C56
C55
C54
C53
C52
C51
C50
C49
C48
C47
C46
C45
C44
C43
C42
C41
C40
Freq (THz)
WL (nm)
195.90
195.80
195.70
195.60
195.50
195.40
195.30
195.20
195.10
195.00
194.90
194.80
194.70
194.60
194.50
194.40
194.30
194.20
194.10
194.00
1530.334
1531.116
1531.898
1532.681
1533.465
1534.250
1535.036
1535.822
1536.609
1537.397
1538.186
1538.976
1539.766
1540.557
1541.349
1542.142
1542.936
1543.730
1544.526
1545.322
Ch. No.
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
C39
C38
C37
C36
C35
C34
C33
C32
C31
C30
C29
C28
C27
C26
C25
C24
C23
C22
C21
C20
Freq (THz)
WL (nm)
193.90
193.80
193.70
193.60
193.50
193.40
193.30
193.20
193.10
193.00
192.90
192.80
192.70
192.60
192.50
192.40
192.30
192.20
192.10
192.00
1546.119
1546.917
1547.715
1548.515
1549.315
1550.116
1550.918
1551.721
1552.524
1553.329
1554.134
1554.940
1555.747
1556.555
1557.363
1558.173
1558.983
1559.794
1560.606
1561.419
Table 3: MS419880 – wavelengths‘ plan.
Ch. No.
Freq (THz)
WL (nm)
Ch. No.
Freq (THz)
WL (nm)
1
C21
192.10
1560.606
21
C41
194.10
1544.526
2
C22
192.20
1559.794
22
C42
194.20
1543.730
3
C23
192.30
1558.983
23
C43
194.30
1542.936
4
C24
192.40
1558.173
24
C44
194.40
1542.142
5
C25
192.50
1557.363
25
C45
194.50
1541.349
6
C26
192.60
1556.555
26
C46
194.60
1540.557
7
C27
192.70
1555.747
27
C47
194.70
1539.766
8
C28
192.80
1554.940
28
C48
194.80
1538.976
9
C29
192.90
1554.134
29
C49
194.90
1538.186
10
C30
193.00
1553.329
30
C50
195.00
1537.397
11
C31
193.10
1552.524
31
C51
195.10
1536.609
12
C32
193.20
1551.721
32
C52
195.20
1535.822
13
C33
193.30
1550.918
33
C53
195.30
1535.036
14
C34
193.40
1550.116
34
C54
195.40
1534.250
15
C35
193.50
1549.315
35
C55
195.50
1533.465
16
C36
193.60
1548.515
36
C56
195.60
1532.681
17
C37
193.70
1547.715
37
C57
195.70
1531.898
18
C38
193.80
1546.917
38
C58
195.80
1531.116
19
C39
193.90
1546.119
39
C59
195.90
1530.334
20
C40
194.00
1545.322
40
C60
196.00
1529.553
Table 4: MS419881 – wavelengths‘ plan.
Dimensions
Order Information
Art. No.
Description
Modules
MS419880
40 Channel AAWG MUX/DEMUX DWDM 19" 1U, Local: 40x LC/PC duplex, Line:
1x LC/PC duplex, 100GHz Grid
MS419881
40 Channel AWG MUX/DEMUX DWDM 19" 1U with 5% Tap, Local: 40x LC/PC
duplex, Line: 1x LC/PC duplex, Tap: 1x LC/PC duplex, 100GHz Grid
MICROSENS reserves the right to make any changes without further notice to any product to improve reliability, function or
design. MICROSENS does not assume any liability arising out of the application or use of any product. pp/3316