NOVEMBER, 2006 WINDOW PANNING AND TRIMS EC 97902-03 1 GENERAL INFORMATION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EXTERIOR PANNING • Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows. The use of panning will often leave much of the existing building finishes undisturbed. • Panning may also be used in new construction, particularly to achieve an historical look. • Panning may be used with any fixed or operable Kawneer Sealair® Window Series. Panning is not recommended for use with storefront or curtain wall systems. • Standard panning profiles are available to accommodate most building conditions. • Historic or custom panning profiles may supplied based on project specific requirements. Please contact your Kawneer representative for detail assistance and associated costs. • Panning is typically supplied factory fabricated to rough opening sizes. Extended panning legs are field trimmed to fit building openings. • Exterior panning must be securely attached to the building conditions prior to the window installation. • Exterior panning legs are completely sealed to the building conditions on all perimeters. • Exterior panning is weather-stripped and sealed prior to installation of the windows. • Stainless steel retention clips are pre-attached to the exterior panning and hold the window in place until final anchoring can be completed. Retention clips are not intended to permanently secure windows in place. • A combination of exterior panning and interior snap trim is normally required to completely cover existing building conditions and finish the interior face of the window. • Standard interior snap trim profiles are available to accommodate most building conditions. • Historic or custom snap trim profiles may be supplied based upon project specific requirements. Please contact your Kawneer representative for detail assistance and associated costs. • Interior snap trim is typically supplied in standard lengths and field cut to opening dimensions. Interior snap trim is attached to the window face and building condition with 3” long clips. • Interior snap trim may be used to securely anchor windows into building openings. • Windows are securely anchored to the building condition with anchors installed through the window frame, strap anchors or interior snap trim. © Kawneer Company, Inc., 2006 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. INTERIOR SNAP TRIM www.kawneer.com WINDOW PANNING AND TRIMS NOVEMBER, 2006 TYPICAL INSTALLATION EC 97902-03 INTERIOR TRIM WINDOW DIM. WINDOW DIM. TOP OF WINDOW 1/4" DAYLITE OPENING DAYLITE OPENING 1/4" 3" LONG BASE CLIP @ 18"O.C. (NOTE: FULL LENGTH CLIPS AVAILABLE) 3" LONG BASE CLIP @ 18" O.C. CONTINUOUS SEAL BOTTOM OF WINDOW TOP OF STOOL INTERIOR TRIM WOOD BLOCKING OR SHIM AS REQUIRED VARIES MASONRY OPENING VARIES PERIMETER SEAL PERIMETER SEAL FIELD TRIM AS REQUIRED www.kawneer.com INSTALLATION NOTE: BACK BED WITH SEALANT BEFORE INSTALLING WINDOW. (TYP.) © Kawneer Company, Inc., 2006 WOOD BLOCKING OR SHIM AS REQUIRED. 3/8" CLEARANCE REQUIRED FOR FASTENER. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FIELD TRIM AS REQUIRED Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TYPICAL PANNING AND TRIM INSTALLATION INTO EXISTING WINDOW OPENING MASONRY OPENING 2 © Kawneer Company, Inc., 2006 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOVEMBER, 2006 WINDOW PANNING AND TRIMS EC 97902-03 WEATHERING AT JAMBS AND HEAD BACK SEAL CORNER JOINT BEAD OF SILICONE AT SILL SPLINE SCREW FOR COPED AND BUTT TYPE CORNER JOINT AT SILL CLIP FOR COPED AND BUTT TYPE CORNER JOINT AT SILL www.kawneer.com 3 ISOMETRIC SPLINE SCREW FOR MITERED CORNER JOINT AT HEAD CLIP FOR MITERED CORNER JOINT AT HEAD BACK SEAL CORNER JOINT WINDOW RETENTION CLIP (106.4) 4-3/16" 1" WINDOW DEPTH 246-240 PANNING @ SILL 2-3/16" (55.5) www.kawneer.com 2-3/16" (55.5) 2-3/16" 246-241 PANNING @ HEAD and JAMBS (55.5) 246-242 PANNING @ HEAD and JAMBS (19.1) 3/4" 1" (25.4) 246-240 PANNING @ SILL 2-3/16" (55.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/4" (6.4) 2" (50.8) TYPICAL PANNING DETAILS © Kawneer Company, Inc., 2006 (19.1) WINDOW DIM. 1/4" (6.4) WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. WINDOW DIM. 3/4" (106.4) (25.4) 4-3/16" WINDOW DIM. 3" (762) 4 NOVEMBER, 2006 EC 97902-03 SCALE 6" = 1' 0" WINDOW DEPTH (125.4) 4-15/16" © Kawneer Company, Inc., 2006 WINDOW DIM. (66.7) (73) WINDOW DEPTH WINDOW DIM. 2-5/8" 246-250 PANNING @ SILL www.kawneer.com (125.4) 1/4" (6.4) 1/4" (6.4) 3-7/8" (98.4) (114.3) 4-1/2" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW DIM. 2-7/8" 4-15/16" WINDOW DIM. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. NOVEMBER, 2006 WINDOW PANNING AND TRIMS EC 97902-03 TYPICAL PANNING DETAILS SCALE 6" = 1' 0" 4" (101.6) 4" (101.6) 246-251 PANNING @ HEAD and JAMBS 246-252 PANNING @ HEAD and JAMBS 2-5/8" (66.7) 2-7/8" (73) WINDOW DEPTH 246-250 PANNING @ SILL 4" 4" (101.6) (101.6) 5 4-15/16" (125.4) (101.6) 246-253 PANNING @ HEAD and JAMBS 2-5/8" (66.7) 2-7/8" (73) 246-250 PANNING @ SILL (101.6) 4" www.kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/4" (6.4) TYPICAL PANNING DETAILS © Kawneer Company, Inc., 2006 WINDOW DIM. WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. 3-3/4" (95.3) 6 NOVEMBER, 2006 EC 97902-03 SCALE 6" = 1' 0" 4" WINDOW DEPTH (114.3) 4-1/2" © Kawneer Company, Inc., 2006 WINDOW DIM. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. 1/4" (6.4) (111.1) 4-3/8" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. NOVEMBER, 2006 WINDOW PANNING AND TRIMS EC 97902-03 TYPICAL PANNING DETAILS SCALE 6" = 1' 0" 5-5/16" (134.9) 246-262 PANNING @ HEAD and JAMBS 4-9/16" (115.9) 4-13/16" (122.2) 246-260 PANNING @ SILL 5-5/16" (134.9) www.kawneer.com WINDOW DEPTH 7 (114.3) 4-1/2" TYPICAL PANNING DETAILS 4-13/16" (122.2) 246-260 PANNING @ SILL 5-5/16" (134.9) www.kawneer.com © Kawneer Company, Inc., 2006 1/4" (6.4) 246-261 PANNING @ HEAD and JAMBS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW DIM. WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. 4-1/2" (114.3) 8 NOVEMBER, 2006 EC 97902-03 SCALE 6" = 1' 0" 5-5/16" (134.9) 4-9/16" (115.9) WINDOW DEPTH 9 WINDOW PANNING AND TRIMS NOVEMBER, 2006 EC 97902-03 TYPICAL TRIM DETAILS SCALE 6" = 1' 0" 1" 246-511 BASE CLIP 2" (50.8) 1-3/4" (44.4) 246-545 COVER 246-530 COVER 246-525 COVER 2" 1-3/4" (44.4) 246-531 BASE CLIP 246-546 BASE CLIP 3" (76.2) 246-515 COVER 3-1/2" (88.9) 246-520 COVER 1" (25.4) 1" 246-541 BASE CLIP 246-521 BASE CLIP 5" 1-1/4" (127) (25.4) 1" 246-551 BASE CLIP 246-600 DRYWALL ANCHOR CLIP www.kawneer.com (12.7) (31.8) 246-550 COVER 1/2" 246-516 BASE CLIP (25.4) 1" 246-540 COVER (25.4) (38.1) (50.8) 1-1/2" 2-1/2" (63.5) © Kawneer Company, Inc., 2006 2" 246-506 BASE CLIP 246-526 BASE CLIP Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1-1/2" 246-501 BASE CLIP (50.8) COVER (38.1) (25.4) 246-510 COVER (25.4) (25.4) 246-505 COVER 1" 028-808 #8 x 1/2" PH 1" (25.4) 246-500 1-1/2" (38.1) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW PANNING AND TRIMS BLANK PAGE www.kawneer.com © Kawneer Company, Inc., 2006 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 NOVEMBER, 2006 EC 97902-03
© Copyright 2026 Paperzz