ProBar Flowmeter

Product Data Sheet
00813-0100-4761; DS-4010
ProBar® Flowmeter
WHEN COMPARED WITH TRADITIONAL
DP FLOW MEASUREMENT, THE
PROBAR FLOWMETER OFFERS
GREATER VALUE AND PERFORMANCE
HIGH PERFORMANCE
ProBar®
• ±0.5% of rate reference accuracy
• 10:1 flow turndown
• Liquids
• Gases and steam (Consult Factory)
• 4—20mA and HART® flow outputs
REDUCED INSTALLATION COSTS
• Installation time reduced by 90%
• Fugitive emission points reduced by 80%
• NEW 2-line scalable display
REDUCED OPERATING COSTS
• Significantly lower pressure drop than
•
•
orifice or vortex meters
Low operating costs
Low maintenance costs
HIGH RELIABILITY
• ISO 9001 company
• NIST Traceable Calibration
COMPLETE POINT SOLUTIONS™
Complete Point Solutions provides fully engineered
measurement solutions, combining best product and
practices for improved performance, reliability,
and cost of ownership.
The capability of the world’s finest industrial
measurement instrumentation is further increased
by combining it with a premier offering of
complimentary products. This system is engineered
and assembled by Rosemount Inc. to make it
easy for you to specify and order the correct
equipment for your process measurement needs.
We complement our field instruments with a wide
range of technologies; including, manifolds,
primary elements, process flanges and seals, and
temperature sensors and accessories.
Complete Point Solutions is designed to provide you
with Best-in-Class equipment — allowing you to
save on installation costs, and improve the reliability
and capability of your process.
Take advantage of our vast experience in process
measurement, and start improving your process
with Complete Point Solutions.
Flow-247
ProBar® Flowmeter
PROBAR
FLOWMETER
PROBAR FLOWMETER- - - - - - - - - - - - - - - - - - - - - - - - - - 251
REINVENTING DP FLOW MEASUREMENT - - - - - - - - - - - - - 251
Per fo rm a nc e
THE PROBAR FLOWMETER - - - - - - - - - - - - - - - - - - - - - - 252
B e ne fits
LOW INSTALLATION COSTS - - - - - - - - - - - - - - - - - - - - - - 254
LOW OPERATING COSTS - - - - - - - - - - - - - - - - - - - - - - - - 255
ProBar®
F e atu re s
FEATURE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 256
BENEFIT- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 256
I n s tal l at i on
( Fo l l ow th e P I PE S P l a n for Q ua l i t y I n s tal lat ion .)
PIPE ORIENTATION - - - - - - - - - - - - - - - - - - - - - - - - - - INSIDE PIPE DIAMETER (ID) - - - - - - - - - - - - - - - - - - - - PIPE PENETRATION - - - - - - - - - - - - - - - - - - - - - - - - - - ELECTRONIC MOUNTING - - - - - - - - - - - - - - - - - - - - - - STRAIGHT RUN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
257
257
257
258
258
S iz ing a nd H ow To Ord er
1. CHOOSE A MOUNTING METHOD - - - - - - - - - - - - - - - - 2. CHOOSE A SENSOR SIZE - - - - - - - - - - - - - - - - - - - - - 3. VERIFY MODEL AND SENSOR SIZE - - - - - - - - - - - - - - 4. CHOOSE THE M ODEL OOPTIONS - - - - - - - - - - - - - - - - 5. VERIFY PROCESS AND PIPE INFORMATION - - - - - - - - - -
Flow-248
259
260
261
263
264
Rosemount Inc.
PROBAR
FLOWMETER
O rde ri n g I n fo rm a ti o n— Mo d el PB R
MODEL PBR+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBR+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBR+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBR+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - -
265
267
270
273
MODEL PBF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBF+25H/26H - - - - - - - - - - - - - - - - - - - - - - - MODEL PBF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - MODEL PBF+45H/46H - - - - - - - - - - - - - - - - - - - - - - - MODEL PBF+45M/46M - - - - - - - - - - - - - - - - - - - - - - - -
281
284
287
293
296
299
302
O rde ri n g I n fo rm a ti o n— Mo d el PN T
ProBar®
O rde ri n g I n fo rm a ti o n— Mo d el PB F
MODEL PNT+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 310
O rde ri n g I n fo rm a ti o n— Mo d el PN F
MODEL PNF+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 312
MODEL PNF+10H - - - - - - - - - - - - - - - - - - - - - - - - - - - - 314
MODEL PNF+10M - - - - - - - - - - - - - - - - - - - - - - - - - - - 316
O rde ri n g I n fo rm a ti o n— Mo d el PN W
MODEL PNW+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - 318
O rde ri n g I n fo rm a ti o n— Mo d el PH T
MODEL PHT+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 325
MODEL PHT+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 328
MODEL PHT+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 331
O rde ri n g I n fo rm a ti o n— Mo d el PH F
MODEL PHF+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+25H - - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+25M - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+45S - - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+45H - - - - - - - - - - - - - - - - - - - - - - - - - - - MODEL PHF+45M - - - - - - - - - - - - - - - - - - - - - - - - - - -
340
343
346
349
352
355
358
361
S p ec i fi c a ti o ns
FUNCTIONAL SPECIFICATIONS - - - - - - - - - - - - - - - - - - - PERFORMANCE SPECIFICATIONS- - - - - - - - - - - - - - - - - - PHYSICAL SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
371
372
373
373
Flow-249
ProBar® Flowmeter
ProBar®®
Flow-250
Rosemount Inc.
PROBAR®
ProBar®
Flowmeter
PROBAR FLOWMETER
The ProBar flowmeter is a
highly accurate insertion
flowmeter. It measures
volumetric flow rate for liquids,
gases, and steam in line sizes
from ½-inch to 72 inches. With
fully integrated Rosemount®
electronics and the Annubar®
sensor, the ProBar flowmeter
provides a ±0.5% of rate
reference accuracy over a
10:1 flow turndown. By fully
calibrating the integral ProBar
flowmeter, Dieterich Standard,
Inc. has eliminated the “percent
of full scale” accuracy and
turndown limitations associated
with differential pressure
(DP) technology.
Dieterich Standard, Inc. has
joined with Rosemount Inc. to
provide the latest technology in
DP flow solutions. Rosemount Inc.
is the technology leader in
offering the highest performance
and highest quality in DP
transmitters. The 3051CD™
provides 0.075% accuracy, 100:1
rangeability, and the best stability
of any industrial transmitter. In
the years since its introduction,
the 3051CD has become the new
standard in DP sensing
technology.
As a member of the Rosemount
Inc. team, Dieterich Standard,
Inc. combines 3051CD based
electronics with the latest in
DP primary technology—
Diamond II+ Annubar primary
flow element.
REINVENTING DP
FLOW MEASUREMENT
By combining integrated
electronics with insertion
flowmeter technology, the
ProBar flowmeter provides the
lowest total cost of any precision
flowmeter. Installation costs are
reduced by insertion through a
small tap into existing piping,
and no plumbing is required
between the electronics and the
sensing element. Due to the
aerodynamic shape of the
sensing element, the ProBar
flowmeter provides low
operating costs. In addition, the
sensor is insensitive to wrap,
wear, and plugging. When
compared with traditional DP
flow measurement, the ProBar
flowmeter offers greater value
and performance. Together,
Dieterich Standard, Inc. and
Rosemount Inc. are reinventing
DP flow measurement.
Flow-251
ProBar® Flowmeter
Performance
THE PROBAR FLOWMETER
Reference Accuracy ± 0.5%
and Turndown 10:1
The ProBar flowmeter has better performance
than vortex, insertion turbine, or DP flowmeters.
Based on proven technology and NIST traceable
calibration, the ProBar flowmeter is far superior
to “percent of full scale” DP flowmeters.
Compared to Traditional
DP Flow Measurement
When compared to traditional DP flow measurement,
ProBar flowmeter improves the “percent of full scale”
errors caused by the transmitter at high turndowns,
and error caused by the primary element over the
entire turndown. When comparing a ProBar flowmeter
to an orifice plate and DP transmitter at a 10:1 flow
turndown, the ProBar flowmeter maintains a ±0.5%
reference accuracy while the errors caused by “percent
of full scale” limitations of the transmitter can lead
to a 5% inaccuracy.
ProBar®
FIGURE 1. Accuracy % Rate.
Sensor Design is Based on Proven
Annubar Primary Flow Element Technology
The ProBar flowmeter is based on DP flow
measurement technology. A DP is generated
across the third generation Diamond II+ Annubar
sensor. The linearity of the Diamond II+ is the
key to the ProBar flowmeter’s accuracy and
turndown capabilities. The DP signal generated is
proportional to the flow rate in accordance with
Bernoulli’s Theorem.
2
2
V1
---------- + P1
------- = V2
---------- + P2
------2gc
ρ
2gc
ρ
FIGURE 2. Bernoulli’s Theorem.
FIGURE 3. Diamond II+ Design.
Diamond II+ design provides a fixed separation point
for linear, repeatable performance.
Flow-252252
FIGURE 4. ProBar DP Flow Measurement.
Rosemount Inc.
Smart electronics
linearize the
flowmeter over a wide
flow turndown. With
ProBar flowmeter
electronics, the
specifications can be
maintained for five
years with no
adjustments. A
4—20mA output
proportional to flow
rate and HART
communications
is standard.
Patented Characterization Process
The ProBar flowmeter is calibrated over a wide
turndown in a NIST traceable calibration flow
laboratory. A characterization curve is formed and
programmed into the electronics. The result is a
linearized flowmeter that matches the actual
volumetric flow rate with a +0.5% reference accuracy.
C ha ract eriza tio n Test
1
Integrated
manifold for
isolation and
calibration
2
F l ow Tu rn do wn
3
ProBar®
4
5
Optional integral
RTD (not shown)
Patented
Pak-Lok®
mounting
for safe
installation
or optional
flange
mounting
Verif i catio n Test
F l ow Tu rn do wn
FIGURE 6. Patented Characterization Process.
The Probar Flowmeter Calibration Process
1. Reference flow is introduced to the ProBar
The sensor spans the entire
pipe and senses the flow
profile. Calibrated in a NIST
traceable flow laboratory, it
has proven reliable in
hundreds of thousands
of applications.
flowmeter in a NIST traceable laboratory.
2. The ProBar flowmeter output is recorded
over flow range.
3. Statistical regression analysis is used to
arrive at the characterization curve.
4. The Characterization curve is programmed
into the ProBar flowmeter electronics via
patented process.
5. The ProBar flowmeter is tested a second time
for verification of +0.5% of rate accuracy — a
calibration test record is generated.
Test Data
The ProBar flowmeter calibration process provides
an actual calibration test record that shows the
ProBar flowmeter maintains +0.5% accuracy over a
10:1 flow turndown at reference conditions. Each
ProBar flowmeter comes with a certified NIST
traceable report that shows the results from the
Dieterich Standard, Inc. flow laboratory.
FIGURE 5. ProBar Flowmeter Diagram.
FIGURE 7. Certified NIST Traceable Report.
Flow-253
ProBar® Flowmeter
Benefits
LOW INSTALLATION COSTS
Compare ProBar Flowmeter
Installation Costs
Compare ProBar Flowmeter Installation
The ProBar flowmeter offers low installation costs
when compared to traditional DP flow measurement.
The fully integrated electronics and sensor eliminate
fittings, tubing, valves, manifolds, adapters, and
mounting brackets and reduce welding and
installation time.
When compared to an orifice and vortex installation,
the ProBar flowmeter saves installation and
hardware costs while offering superior accuracy and
turndown. The larger the line size, the more value
the ProBar flowmeter offers.
6 inch (150 mm) pipe,
water 300# ANSI
See the ProBar flowmeter manual for the recommended
installation of the ProBar flowmeter.
Flowmeter or sensor
Mounting hardware
ProBar®
Transmitter
Manifold, valves & bracket
Weld (mounting)
Fittings & Tubing
Wiring
Start-up (Cal/Config)
ProBar Flowmeter
Vortex
Orifice
Traditional DP
Installation
ProBar Flowmeter
Installation
FIGURE 8. ProBar Flowmeter vs. Traditional DP.
Traditional
ProBar Flowmeter
16
Fittings & tubing
0
4
Valves
0
1
Manifold
Integral
2
Adapter unions
0
1
Transmitter mounting
bracket
0
50 linear inches
Welding
4 linear inches
33
Leak points
6
FIGURE 9. Installation Cost Comparison.
Ref: 6”SCH40, 100# Steam, 11,300PPH
Easy Plug-And-Play Installation
The ProBar flowmeter provides the lowest cost
installation of any precision flowmeter. The easy
“plug-and-play” installation of the ProBar flowmeter
includes four steps:
1.
2.
3.
4.
Drill a hole into the existing process piping.
Weld a fitting onto the pipe.
Insert the ProBar flowmeter.
Wire to the DCS, recorder, or HART host.
TABLE 1. ProBar Flowmeter vs. Traditional DP.
FIGURE 10. Plug-and-Play Installation.
Flow-254254
LOW OPERATING COSTS
Low Maintenance Costs
Low Permanent Pressure Loss
The ProBar flowmeter sensor shape is designed to
prevent wear and plugging that could affect
calibration. The electronics are the most stable in
the industry and will not drift outside of the total
performance specification. Recalibration should not
be required in a five-year period, providing
significant savings in maintenance costs.
The ProBar flowmeter has the lowest pressure drop
and operating cost of any DP or vortex flowmeter.
The aerodynamic shape of the ProBar flowmeter
does not restrict the flow like the bluff body of a
vortex shedder or the restrictive opening of an
orifice plate.
FIGURE 13. Non-plug design.
Reliability
ProBar®
Rosemount Inc.
• ISO 9001 certified
FIGURE 11. Permanent Pressure Loss.
• NIST traceable calibration
Ref: 6”SCH40, 100# Steam, 11,300PPH
• Proven technology supplied by
leading manufacturers
Energy Cost Saving
Permanent pressure loss can be converted directly
into energy costs in the form of compressor costs for
gas, electrical costs for pumping liquids, and fuel
costs for generating steam. Energy savings increase
with line size and flow rate. The payback time for a
ProBar flowmeter can be as short as six months in
energy savings alone. Contact your local salesperson
for a cost savings analysis of your application.
• 300 sales and service centers in 120 countries
• 90 years experience in flow
measurement solutions
ÿþý
ÿþýüýýý
ÿþ
ý
þ
þ
ÿüýýý
ÿþüýýý
FIGURE 14. ProBar Flowmeter Reliability.
ÿýý
ÿý
ÿþý
4”
(100mm)
8”
(200mm)
12”
(300mm)
14”
(400mm)
ProBar Flowmeter
Vortex
Orifice
FIGURE 12. Energy Costs.
Ref: 6”SCH40, 100# Steam, 11,300PPH
Flow-255
ProBar® Flowmeter
Features
FEATURE
Integral RTD
BENEFIT
A three wire 100 Ω platinum RTD is inserted into a
sealed, pressure retaining thermowell in the sensor.
Connections are made through an explosion-proof
junction box.
A single pipe
penetration allows
measurement of
mass flow, including
temperature.
Designs by other vendors that do not provide a sealed
thermowell are a potential hazard when removal
of the RTD is required. The integral RTD eliminates
hardware and installation costs.
Integrated Electronics Mounting
FIGURE 15. Integral RTD.
Pak-Lok® Mounting
ProBar®
Pak-Lok mounting seals and secures the ProBar
flowmeter firmly against the inside opposite wall
simply and without high torque requirements. This
design safely retains the sensor under high process
pressures. It also provides additional structural
support by placing the sensor in compression.
Allows safe and
simple installation
of ProBar flowmeter.
FIGURE 16. Pak-Lok Mounting.
Flanged Pipe Section
A good installation of the sensor is assured with
the flanged pipe section option. The pipe can be
made to any length for easy replacement of other
piping components.
The ProBar
flowmeter can be
mounted in a flanged
pipe section for easy
installation between
existing flanges.
FIGURE 17. Flanged Pipe Section.
Direct Mount Integral Manifold
The ProBar flowmeter electronics can be mounted
directly to the sensor by means of either a 3- or
5-valve manifold. Upwards of 28 potential leak
paths can be eliminated. The integral mount can
be used in all fluids except where the temperature
exceeds 500 °F (260 °C).
Allows the
electronics to be
mounted directly
to the sensor,
eliminating costs
and leak paths.
FIGURE 18. Direct Mount
Integral Manifold.
Elbow Mount
ProBar flowmeter can be installed two pipe diameters ProBar flowmeter
from the centerline of an elbow and still provide good can achieve good
accuracy and repeatability: +3% without calibration.
accuracy two
pipe diameters
from an elbow.
FIGURE 19. Elbow Mount.
Flo-Tap ProBar Flowmeter
Flo-Tap ProBar flowmeter is perfectly suited to
retrofit applications because the Flo-Tap can
be hot-tapped without interruption of the flow,
and without system shutdown.
Allows insertion and
retraction without
system shutdown.
Bi-directional Flow Measurement
The symmetrical design, along with the controlled
separation point provided by the exclusive
diamond–shaped sensor means a single ProBar
flowmeter is all that is required for bi-directional
flow measurement.
Flow-256
A single ProBar
flowmeter can
provide accurate
bi–directional
flow measurement.
FIGURE 20. Bi-directional
Flow Measurement.
Rosemount Inc.
Installation
(Follow the PIPES Plan for Quality Installation.)
The performance of any flow measurement device
depends greatly upon the quality of the installation.
This is also true for ProBar flowmeter. Studies have
shown that greater than 70% of flow measurement
problems are traceable to installation error.
Installation of ProBar flowmeter is very simple, but
attention must be paid to simple principles. These
principles are common to all DP devices and most
flowmeters in general. The Dieterich Standard, Inc.
acronym for these principles is “PIPES”:
INSIDE PIPE DIAMETER (ID)
It is important to use the exact pipe ID in ProBar
flowmeter installations to avoid flow measurement
errors. Throat diameter is a squared factor for
DP flow measurement devices. With the ProBar
flowmeter, the pipe itself forms the throat. Using
the pipe as the throat of the meter reduces
permanent pressure loss and the effect of wear
on the throat.
Pipe orientation
Flow = CD
2
DP
ProBar®
Inside diameter
Pipe penetration
Electronics mounting
Straight run
PIPE ORIENTATION
The sensor must be installed in the proper
orientation relative to the pipe and the
fluid measured. This must be specified at
the time of order placement. For gases,
the electronics must be mounted above the
pipe. For liquid and steam, the electronics
must be mounted below the pipe. See the
I/O manual for detailed installation instructions.
Preferred
Location
Mounting
þý
þý
FIGURE 22. Pipe ID.
PIPE PENETRATION
The sensor mounting hole must be smooth and
the correct size to avoid disturbing the flow profile.
Drilling is the only acceptable method to properly
prepare the mounting hole. See hole size
recommendations in the manual 00809-0100-4761.
þý
þý
ÿþý
Gas Installation
Liquid or Steam Installation
FIGURE 21. Pipe Orientation.
FIGURE 23. Sensor Mounting Hole.
Flow-257
257
ProBar® Flowmeter
ELECTRONIC MOUNTING
STRAIGHT RUN
Mounting of the electronics can be either integral or
remote. Integral is preferred because of simplified
installation, fewer leak points, faster response, and
greater accuracy. Remote mounting is required when
the process temperature exceeds 500 °F (260 °C) or
when there is excessive vibration. Where remote
mounting of the electronics is required, it is
important that the orientation of the electronics
relative to the sensor is correct. For gases, the
electronics must be above the sensor and for liquids,
below the sensor. It is critical to review the I/O
manual on this topic and on commissioning.
To obtain published accuracy, sufficient straight run
is required to produce a fully developed flow profile.
Shorter lengths are possible, but accuracy will be
affected. See Table 2 for recommended straight run
requirements for the ProBar flowmeter.
Straight run requirements are also more stringent for
achieving the highest accuracy. The recommended
values shown are upstream straight run requirements.
Four diameters are required downstream.
ProBar®
Location
With Vanes
Without Vanes
After an elbow
8
10
Two elbows out of plane
8
28
After a modulating control valve
8
30
After an expansion
8
18
After a constriction
8
12
TABLE 2. Upstream Straight Run Requirements.
Integral Mounting
Remote Mounting
FIGURE 24. Electronic Mounting.
Flow-258
Rosemount Inc.
Sizing and How To Order
1. CHOOSE A MOUNTING METHOD
PBR
PBF
FIGURE 25. Regular Threaded
Pak–Lok Assembly.
FIGURE 26. Flanged.
PHF
ProBar®
Mounting Method
Mounting Method
Flanged.
Threaded Pak–Lok.
Pipe Sizes
Pipe Sizes
2 in. to 72 in. (50 mm to 1800 mm).
2 in. to 72 in.(50 mm to 1800 mm).
PHT
FIGURE 27. High Pressure
Flanged Flo–Tap.
FIGURE 28. High Pressure
Threaded Flo-Tap.
Mounting Method
Flanged Flo–Tap for pressure
equivalent to ANSI Class 600 Flanges.
Pipe Sizes
2 in. to 72 in. (50 mm to 1800 mm).
Mounting Method
Threaded Flo-Tap for pressure
equivalent to ANSI Class 600 Flanges.
Pipe Sizes
2 in. to 72 in. (50 mm to 1800 mm).
PNF
PNT
FIGURE 29. Flanged In–Line.
Mounting Method
Flanged In–Line.
Pipe Sizes
½ in. to 2 in. (25 mm to 50 mm).
FIGURE 30. Threaded In-Line.
Mounting Method
Threaded In–Line.
Pipe Sizes
½ in. to 2 in. (25 mm to 50 mm).
PNW
FIGURE 31. Butt Weld In-Line.
Mounting Method
Butt Weld In–Line.
Pipe Sizes
½ in. to 2 in. (25 mm to 50 mm).
Flow-259
ProBar® Flowmeter
2. CHOOSE A SENSOR SIZE
The following table is a guideline for selecting
the correct sensor.
Sensor
Pipe Sizes
10 - PNT, PNW & PNF
½ in. to 2 in.
(DIN 15-DIN 50)
ProBar®
15/16
2 in. to 5 in.
(DIN 50-DIN 125)
25/26
4 in. to 42 in.
(DIN 100-DIN 1000)
35/36
10 in. to 72 in.
(DIN 200 to DIN 1800)
45/46
16 in. to 72 in.
(DIN 250 to DIN 1800)
Conversions for Verifications of Flows
for Fluids Other Than Air and Water
1. To convert GPM of water to GPM of any other
fluid, divide the maximum GPM by the square
root of the specific gravity of the liquid.
GPM
other
GPM
water
= ------------------------------SG other
2. To convert SCFM of air to SCFM of any other gas,
divide the max SCFM by the square root of the
specific gravity of the other gas.
SCFM air
SCFM other = ----------------------------SG
other
TABLE 3. Sensors and Pipe Sizes.
3. To convert standard flow rates to actual flow
rates (gas):
Pf
35.302 × --------------------------- xACFM
( T f + 460 )
Pf = Flowing pressure (psia)
Tf = Flowing temperature (°F)
( T + 460°F )
f
ACFM × ----------------------------------- × SCFM
( P f × 35.302 )
4. To convert volume flow to mass flow:
3
GPM × DensityofLiquid ( lb ⁄ ft )
PPM = ---------------------------------------------------------------------------------------------7.48
PPM = ACFM × DensityofGas
5. To convert U.S. to metric units:
LPM = GPM × 3.78533
lb ⁄ hr × 2.205 = kg ⁄ hr
3
SCFH
NM H = -----------------35.37
Flow-260
Rosemount Inc.
3. VERIFY MODEL & SENSOR SIZE
Compare the maximum allowable flow below to your maximum flow rates.
Sensor 10
PNT
PNF
PNW
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
.5
180.52
1500
50.943
180.52
1500
50.943
180.52
1500
50.943
.75
307.79
1500
89.404
307.79
1500
89.404
307.79
1500
89.404
1
498.82
1500
144.9
498.82
1500
144.9
498.82
1500
144.9
1.25
765.68
1180
222.41
765.68
1180
222.41
765.68
1180
222.41
1.5
902.04
884
262.02
902.04
884
262.02
902.04
884
262.02
2
1174.9
552
341.28
1174.9
552
341.28
1174.9
552
341.28
Sensor 15
PBR
Sensor 16
PBF
PHF
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
PBR
PBF
GPM
SCFM
hw
GPM
SCFM
hw
GPM
2
1236.1
611
359.05
502.91
84.3
133.37
1555
967
451.7
1236.1
611
359.05
1322
699
384.04
2.5
1531.9
451
440.14
639.74
66.9
169.52
1886.4
699
547.95
1531.9
451
440.14
1641
529
476.68
3
2010.5
314
567.07
859.71
50.5
227.41
2408.7
478
699.65
2010.5
314
567.07
2175.3
380
623.82
3.5
2408.7
246
671.26
1046.1
41.7
276.37
2852.6
369
822.13
2408.7
246
671.26
2639.5
305
747.44
4
2816
199
777.38
1237.1
35.1
326.48
3331.3
294
944.89
2816
199
777.33
3126.9
253
876.53
5
3723.8
137
1013.6
1663.7
25.6
438.17
4364.9
195
1209.3
3723.8
137
1013.6
4213.3
180
1161.9
Sensor 25
PBR
ProBar®
Nom.
pipe
size (in
inches)
Sensor 26
PBF
PHF
PBR
PBF
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
4
6263.45
1090
1819.4
2827.2
189
757.59
7347.5
1500
2134.3
6263.4
1090
1819.4
7047.5
1380
2047.1
5
8148.5
747
2366.9
3798.1
138
1017.3
10066
1140
2924
8148.5
747
2366.9
9366.4
987
2720.7
6
10088
549
2930.2
4839.5
107
1293.6
12299
816
3572.4
10088
549
2930.2
11783
749
3422.6
8
14100
346
4028.2
6867.4
71.2
1827.3
16486
489
4788.8
14100
346
4029.2
16570
494
4813.2
10
18737
235
5232.7
9125.3
50.2
2418.5
21270
318
6087.1
18737
235
5232.7
22053
348
6367.7
12
23218
174
6391.4
11299
38
2986.8
26142
228
7316.3
23218
174
6391.4
27773
263
7857.8
14
25971
147
7099.9
12665
32.6
3343.5
29131
190
8071.7
25971
147
7099.9
31411
226
8803.3
16
30390
116
8238.9
14829
26.1
3908.1
33874
147
9274.7
30390
116
8238.9
37265
182
10320
18
34880
94.2
9397.7
17017
21.4
4479.2
38584
117
10473
34880
94.2
9397.7
43086
149
11819
20
39558
77.7
10608
19311
17.8
5077.3
43384
94.5
11699
39558
77.7
10608
49210
124
13401
24
48768
55.7
12990
23901
13
6275.5
52897
66
14140
48768
55.7
12990
61463
90.6
16567
30
65577
35.6
17355
32211
8.43
8445.5
70325
41.1
18648
65577
35.6
17355
83933
59.3
22399
36
80406
25.2
21207
39598
6.03
10374
85555
28.6
22592
80406
25.2
21207
103900
42.6
27573
42
95305
18.8
25083
47023
4.53
12313
100650
21
26510
95305
18.8
25083
123750
32
32725
hw = maximum differential pressure in inches of water column.
½ in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute
30 in. to 42 in. Sch Std.
GPM = maximum water flow in gallons per minute
48 in. to 72 in. Actual I.D.
At standard conditions: Air — 60 °F at 14.73 psia
Water — 60 °F, specific gravity 1.0, viscosity 1.12 centipoise
Flow-261
ProBar® Flowmeter
Nom.
pipe
size (in
inches)
Sensor 35
PBR
Sensor 36
PBF
SCFM
hw
GPM
SCFM
hw
PHF
PBR
GPM
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
ProBar®
8
20661
768
6001.4
9950.2
153
2678.7
24501
1080
7116.8
20661
768
6001.4
24387
1070
7083.8
10
26823
521
7791.3
13239
108
3547.4
31224
706
9069.8
26823
521
7791.3
32204
751
9351.3
12
32883
385
9507.2
16469
82.3
4395.6
37485
505
10088
32833
385
9507.2
39824
570
11568
14
37058
327
10589
18488
70.7
4923.8
41364
421
12015
37058
327
10589
44625
490
12962
16
43668
258
12287
21590
56.7
5760.1
48040
325
13791
43668
258
12287
52273
394
15184
18
50338
209
13998
24947
46.6
6609.8
55095
258
15553
50338
209
13998
60481
324
17429
20
57299
172
15783
28344
38.8
7496.1
62559
210
17439
57299
172
15783
69596
270
19774
24
71017
123
19303
36548
28.3
9259.1
76801
146
21031
71017
123
19303
87990
198
24491
30
96282
78.9
25837
47441
18.4
12477
103040
91.1
27763
96282
78.9
25837
121480
130
33165
36
118650
56
31613
58452
13.2
15348
125830
63.3
33611
118650
56
31613
151120
93.2
40783
42
141020
41.8
37402
69564
9.95
18248
148640
46.6
39491
141020
41.8
37402
181070
70.3
48505
48
163400
32.4
43205
80662
7.76
21144
171330
35.7
45353
163400
32.4
43205
211020
54.9
56240
60
208140
21.1
54825
102920
5.1
26954
216230
22.8
56991
206140
21.1
54825
270800
36.1
71712
72
253470
14.9
66623
125280
3.61
32793
261750
15.9
68822
253470
14.9
66623
330970
25.6
87327
Sensor 45
PBR
Sensor 46
PBF
PHF
PBR
PBF
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
SCFM
hw
GPM
10
41878
1270
12165
20133
256
5461.5
45513
1500
13220
41878
1270
12165
45513
1500
13220
12
51142
940
14855
24994
195
6766.1
59210
1260
17199
51142
940
14855
61288
1350
17803
14
56913
797
16532
28092
168
7590.1
65325
1050
18975
56913
797
16532
68661
1160
19944
16
66100
630
19200
33012
135
8888.1
74858
808
21744
66100
630
19200
80698
939
23441
18
75353
511
21888
38019
111
10201
84461
642
24539
75353
511
21888
92738
774
26938
20
85108
422
24722
43418
93.2
11618
94565
521
27469
85108
422
24722
105460
648
30634
24
106480
303
30297
53975
68.2
14374
114620
364
33207
106480
303
30291
130590
475
37933
30
146170
194
40515
73415
44.7
19448
156190
226
43729
146170
194
40515
178800
313
51462
36
181760
138
49627
90648
32.1
23938
192700
157
52933
181760
138
49627
226020
226
63508
42
217210
103
58712
108240
24.3
28517
229510
116
62307
217210
103
58712
273660
171
75649
48
251110
78.8
67379
125770
19
33086
265390
88.6
71446
251110
78.8
67379
321370
134
87865
60
321930
51.5
85653
160730
12.5
42190
337470
56.8
89952
321930
51.5
85653
416410
88.4
112220
72
392880
36.3
103990 195900
8.86
51374
408770
39.4
108340 392800
36.3
103990 511830
62.8
136780
hw= maximum differential pressure in inches of water column.
½ in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute
30 in. to 42 in. Sch Std.
GPM = maximum water flow in gallons per minute
48 in. to 72 in. Actual I.D.
At standard conditions: Air — 60 °F at 14.73 psia
Water — 60 °F, specific gravity 1.0, viscosity 1.12 centipoise
Flow-262
PBF
Rosemount Inc.
4. CHOOSE THE MODEL OPTIONS
Description
®
Page Numbers
PBR+15/16S
ProBar + Flowmeter—Regular (Threaded, Pak-Lok), SST
page 265
PBR+25/26S
ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST
page 267
PBR+35/36S
ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST
page 270
PBR+45/46S
ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST
page 273
PBF+15/16S
ProBar® + Flowmeter—Flanged, SST
page 281
PBF+25/26S
ProBar® + Flowmeter—Flanged, SST
page 284
PBF+25/26H
ProBar® + Flowmeter—Flanged, Hastelloy–C
page 287
PBF+25/26M
ProBar® + Flowmeter—Flanged, Monel
page 290
PBF+35/36S
ProBar® + Flowmeter—Flanged, SST
page 293
PBF+45/46S
ProBar® + Flowmeter—Flanged, SST
page 296
PBF+45/46H
ProBar® + Flowmeter—Flanged, Hastelloy–C
page 299
PBF+45/46M
ProBar® + Flowmeter—Flanged, Monel
page 302
Line Sizes—2 in. and larger
PNT+10S
ProBar® + Flowmeter—In-Line Threaded, SST
page 310
PNF+10S
ProBar® + Flowmeter—In-Line Flanged, SST
page 312
®
PNF+10H
ProBar + Flowmeter—In-Line Flanged, Hastelloy-C
page 314
PNF+10M
ProBar® + Flowmeter—In-Line Flanged, Monel
page 316
PNW+10S
ProBar® + Flowmeter—In-Line Butt Weld, SST
page 318
ProBar®
Model Numbers
Line Sizes—½ in. to 2 in.
PHT+15S
ProBar® + Flowmeter—Threaded Flo-Tap, SST
page 325
PHT+25S
ProBar® + Flowmeter—Threaded Flo-Tap, SST
page 328
PHT+35S
ProBar® + Flowmeter—Threaded Flo-Tap, SST
page 331
PHF+15S
ProBar® + Flowmeter—Flanged Flo-Tap, SST
page 340
®
PHF+25S
ProBar + Flowmeter—Flanged Flo-Tap, SST
page 343
PHF+25M
ProBar® + Flowmeter—Flanged Flo-Tap, Monel
page 349
PHF+35S
ProBar® + Flowmeter—Flanged Flo-Tap, SST
page 352
PHF+45S
ProBar® + Flowmeter—Flanged Flo-Tap, SST
page 355
PHF+45H
ProBar® + Flowmeter—Flanged Flo-Tap, Hastelloy-C
page 358
PHF+45M
ProBar® + Flowmeter—Flanged Flo-Tap, Monel
page 361
Flow-263
ProBar® Flowmeter
5. VERIFY PROCESS AND PIPE INFORMATION
Configuration Information
When ordering a ProBar, it is important to include all of the flowing conditions and pipe information for your
application. This will ensure that you receive the correct product for your application. Please see the ProBar
Configuration Data Sheet 00806–0100–4761.
Dimension Codes
Certain dimensions are critical to the fabrication of the primary flow element assembly. The following codes
can be specified in the model callout “string” and Dieterich Standard, Inc. will build the primary flow element
assembly to suit. If no dimension is specified, cataloged components will default to standard dimensions.
ProBar®
ODH
ODV
ODH is the outside diameter of the pipe to the top of
the ProBar head (Figure 25). If this dimension is
specified for a flanged, Flo–Tap, or Regular model,
the neck of the primary flow element just below
standard dimension can be considered a minimum.
This dimension does not apply to in–line sensors or
to Model 45S.
ODV is the outside diameter of the pipe to the top of
the isolation valve (Figure 27). ODV applies to
Flo–Tap models only, and only when the customer
supplies some or all of the mounting hardware.
ODV
ODH
FIGURE 27. ODV.
NL
FIGURE 25. ODH.
ODF
ODF is the outside diameter of the pipe to the face
of the mounting flange (Figure 26). This dimension
applies only to DFF, DHF, DSF, NFF, SPF, SFF,
and SSF models. If Dieterich Standard, Inc. is not
supplying the mounting hardware, this dimension
must be specified. If Dieterich Standard, Inc.
is providing the mounting flange assembly, note
the following:
NL is the nipple length for DNW, DNF, and DNT-10
in-line models (Figure 28). Additional length can be
specified to fit specific piping configurations. The
extra length will be applied upstream of the sensor
unless otherwise specified.
• The standard ODF is a minimum.
• The extensions must be at least 2 inches
longer than the minimum ODF.
ODF
FIGURE 28. NL.
CMH
CMH is the customer mount height distance from
the outside of the pipe to the top of the appropriately
sized NPT threaded female mounting coupling
(Figure 29). Supply these values for Regular and
Flo–Tap models that are being installed in a
customer’s mounting or saddle.
FIGURE 26. ODF.
CMH
FIGURE 29. CMH.
Flow-264
Rosemount Inc.
Ordering Information—Model PBR
MODEL PBR+15S/16S
PBR+15S
PBR+16S
Code
020
025
030
035
040
050
Code
Product Description
ProBar® + Flowmeter - Regular
ProBar® + Flowmeter - Regular with Opposite SIde Support
Line Size
2 in. (50 mm)
21/2 in. (63.5 mm)
3 in. (80 mm)
31/2 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HA2S0
HA2SS
HP2S0
HP2SS
Remote Mount - Horizontal
Line
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2C0
CP2C0
SA2C0
SP2C0
Needle Valve - CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0
CA2SS
CP2S0
CP2SS
SA2S0
SP2S0
SP2SS
Needle Valve - SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle valve, Nipple,1/2 in. Socket Weld Port, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2C0
CC2C0
SB2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT,
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
1
Outside Stem and Yoke Gate Valve, Nipple and Tee, /2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0
CB2SS
CC2S0
CC2SS
SB2S0
SC2S0
SV2S0
SV2SS
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Elbow,1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Nipple,1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SST
Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT,SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Port, SST
Code
MP2C0
MP2S0
MR2C0
MR2S0
Code
0
1
2
3
Code
A
Code
1
2
ProBar®
Model
Mounting Hardware
Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, SST
Pak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, CS
Pak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4–20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Flow-265
ProBar® Flowmeter
MODEL PBR+15S/16S
Code
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum 1/2—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G1/2
Code
Opposite Side Support (Required for Model 16S ONLY)
MS2C0
MS2CW
MS2S0
MS2SW
Contoured Weld Fitting and Plug, 1/2—14 NPT, CS
Contoured Weld Fitting and Plug, 1/2 in. Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1/2—14 NPT, SST
Contoured Weld Fitting and Plug, 1/2 in. Socket Weld Port, SST
ProBar®
Code
Optional Auxiliary Mounting (Mounting Alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT2C
MT2S
ME2C
ME2A
ME2K
ME2P
ME2S
NB20
NC20
ND20
NE20
NF20
Contoured Weld Fitting, 1/2—14 NPT, CS
Contoured Weld Fitting, 1/2—14 NPT, SST
Weld Coupling, 1/2—14 NPT, CS
Weld Coupling, 1/2—14 NPT, Aluminum
Weld Coupling, 1/2—14 NPT, Copper
Weld Coupling, 1/2—14 NPT, PVC
Weld Coupling, 1/2—14 NPT, SST
Saddle, Double Strap, 2.35-2.56, 1/2—14 NPT, Iron
Saddle, Double Strap, 2.41-2.91,1/2—14 NPT, Iron
Saddle, Double Strap, 2.97-3.54,1/2—14 NPT, Iron
Saddle, Double Strap, 4.14-4.80,1/2—14 NPT, Iron
Saddle, Double Strap, 5.94-6.70,1/2—14 NPT, Iron
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
L
M
Z
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID <= 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBR+15S 020 HA2S0 CA2C0 MP2C0 1 A 1 A
Flow-266
Rosemount Inc.
MODEL PBR+25S/26S
PBR+25S
PBR+26S
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
ProBar® + Flowmeter - Regular
ProBar® + Flowmeter - Regular with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, with 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATS0
HATSB
HATSD
HATSN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, with 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD,B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, SST
Integral, with 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVDS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0
HA2SS
HP2S0
HP2SS
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line,1/2—14 NPT, SST
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line,1/2 in. Socket Weld Port, SST
Parallel, Vertical Line,1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2C0
CP2C0
SA2C0
SP2C0
Needle Valves - CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee,1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0
CA2SS
CP2S0
CP2SS
SA2S0
SP2S0
SP2SS
Needle Valve - SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow, ½ in. Socket Weld Port, SST
Needle Valve, Nipple,1/2—14 NPT, SST
Needle valve, Nipple,1/2 in. Socket Weld Port, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2C0
CC2C0
SB2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
ProBar®
Model
Valve, Elbow, 1/2—14 NPT, CS
Valve, Nipple, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Flow-267
ProBar® Flowmeter
MODEL PBR+25S/26S
Code
CB2S0
CB2SS
CC2S0
CC2SS
SB2S0
SC2S0
SV2S0
SV2SS
Code
MR4C0
MR4S0
MP4C0
MP4S0
Code
ProBar®
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MS4C0
MS4CW
MS4S0
MS4SW
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow, 1/2in. Socket Weld Port, SST
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple, 1/2in. Socket Weld Port, SST
Valve, Elbow and Tee, 1/2—14 NPT,SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee,1/2—14 NPT,SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Mounting Hardware
Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, CS
Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, SST
Pak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4–20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 1/2—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G1/2
Opposite Side Support (Required for Model 26S ONLY)
Contoured Weld Fitting and Plug, 1—11.5 NPT, CS
Contoured Weld Fitting and Plug, 1in. Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
Contoured Weld Fitting and Plug, 1in. Socket Weld Port, SST
Code
Optional Auxiliary Mounting (Mounting Alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT4C
MT4S
ME4C
ME4A
ME4K
ME4P
ME4S
NE40
NF40
NG40
NH40
NJ40
Contoured Weld Fitting, 1—11.5 NPT, CS
Contoured Weld Fitting, 1—11.5 NPT, SST
Weld Coupling, 1—11.5 NPT, CS
Weld Coupling, 1—11.5 NPT, Aluminum
Weld Coupling, 1—11.5 NPT, Copper
Weld Coupling, 1—11.5 NPT, PVC
Weld Coupling, 1—11.5 NPT, SST
Saddle, Double Strap, 3.74-4.55OD, 1—11.5 NPT, Iron
Saddle, Double Strap, 5.94-6.7in.OD,1—11.5 NPT, Iron
Saddle, Double Strap, 8.54-10.1OD,1—11.5 NPT, Iron
Saddle, Double Strap, 10.64-12.12,1—11.5 NPT, Iron
Saddle, Double Strap, 12.6-14.3OD,1—11.5 NPT, Iron
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Flow-268
Instrument Connections (Continued)
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2in. Pipe/Panel, SST Bolts
Rosemount Inc.
MODEL PBR+25S/26S
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
Code
Typical Model Number PBR+25S 040 HAMS0 C0000 MP4C0 1 A 1 A
Flow-269
ProBar® Flowmeter
MODEL PBR+35S/36S
Model
PBR+35S
PBR+36S
Code
080
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
ProBar®
Flow-270
Product Description
ProBar® + Flowmeter - Regular
ProBar® + Flowmeter - Regular with Opposite Side Support
Line Size
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1,Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, with 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATS0
HATSB
HATSD
HATSN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, with 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD,B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, SST
Integral, with 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, with 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0
HA2SS
HP2S0
HP2SS
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line,1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CA2C0
CP2C0
SA2C0
SP2C0
Needle Valve - CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0
CA2SS
CP2S0
CP2SS
SA2S0
SP2S0
SP2SS
Needle Valve - SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2C0
CC2C0
SB2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Elbow, 1/2—14 NPT, CS
Valve, Nipple, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Rosemount Inc.
MODEL PBR+35S/36S
CB2S0
CB2SS
CC2S0
CC2SS
SB2S0
SC2S0
SV2S0
SV2SS
Code
MP6C0
MP6S0
MR6C0
MR6S0
Code
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MS6C0
MS6CW
MS6S0
MS6SW
Instrument Connections (Continued)
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam,1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Mounting Hardware
Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, SST
Pak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, CS
Pak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 1/2-14
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G1/2
Opposite Side Support (Required for Model 36S ONLY)
Contoured Weld Fitting and Plug, 1 1/2—11.5 NPT, CS
Contoured Weld Fitting and Plug, 1 1/2 in. Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1 1/2—11.5 NPT, SST
Contoured Weld Fitting and Plug, 1 1/2 in. Socket Weld Port, SST
Code
Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT6C
MT6S
Contoured Weld Fitting,11/2—11.5 NPT, CS
Contoured Weld Fitting,11/2—11.5 NPT, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
ProBar®
Code
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Flow-271
ProBar® Flowmeter
MODEL PBR+35S/36S
Code
I5
C6
E5
K5
ID
ED
Code
ProBar®
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBR+35S 120 HAMS0 C0000 MP6C0 1 A 1 A
Flow-272
Rosemount Inc.
MODEL PBR+45S/46S
PBR+45S
PBR+46S
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Descriptions
ProBar® + Flowmeter-Regular
ProBar® + Flowmeter-Regular with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, with 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATS0
HATSB
HATSD
HATSN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, with 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0
HVDSN
HVMS0
HVPS0
HVTSB
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, SST
Integral, with 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, with 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0
HA2SS
HP2S0
HP2SS
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
Parallel, Horizontal Line,1/2 in. Socket Weld Port, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line,1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0
CP2SS
SP2S0
SP2SS
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
ProBar®
Model
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT,SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT,SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Flow-273
ProBar® Flowmeter
MODEL PBR+45S/46S
Code
MPDC0
MPDS0
Code
0
1
2
3
Code
A
Code
1
2
Code
ProBar®
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
Pak-Lok, with Contoured Weld Fitting, 3—11.5 NPT, CS
Pak-Lok, with Contoured Weld Fitting, 3—11.5 NPT, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4–20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 1/2—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G1/2
Opposite Side Support (Required for Model 46S ONLY)
Contoured Weld Fitting and Cap, 3 in. BW, CS
Contoured Weld Fitting and Cap, 3 in. BW, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Flow-274
Mounting Hardware
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Rosemount Inc.
MODEL PBR+45S/46S
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBR+45S 240 HAMS0 C0000 MPDC0 1 A 1 A
ProBar®
Code
Flow-275
ProBar® Flowmeter
ProBar®
276
Flow-276
ProBar®
Rosemount Inc.
Flow-277
ProBar® Flowmeter
ProBar®
278
Flow-278
ProBar®
Rosemount Inc.
Flow-279
ProBar® Flowmeter
ProBar®
280
Flow-280
Rosemount Inc.
Ordering Information—Model PBF
MODEL PBF+15S/16S
PBF+15S
PBF+16S
Code
020
025
030
035
040
050
Code
Product Description
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
2 in. (50 mm)
21/2 in. (63.5 mm)
3 in. (80 mm)
31/2 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HADS0
HADSB
HADSN
HAPS0
HAMS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVPS0
HVMS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
HA2S0
HA2SS
HP2S0
HP2SS
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in., Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
Parallel, Horizontal Line, 1/2 in., Socket Weld Port, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in., Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in., Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
CP2SS
SP2S0
SP2SS
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Elbow, 1/2 in., Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple, 1/2 in., Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2 in., Socket Weld Port, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2 in., Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SST
Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in., Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code
FNMS0
FLMS0
FJMS0
FC4S0
FB4S0
FA4S0
ProBar®
Model
Sensor Flange
DIN 25 PN 100, 316 SST
DIN 25 PN 40, 316 SST
DIN 25 PN 16, 316 SST
1 in. ANSI Class 600, RF, SST
1 in. ANSI Class 300, RF, SST
1 in. ANSI Class 150, RF, SST
Flow-281
ProBar® Flowmeter
MODEL PBF+15S/16S
Code
Flanged Mount
FA4C
FA4S
FB4C
FB4S
FC4C
FC4S
FJMC
FJMS
FLMC
FLMS
FNMC
FNMS
1 in. ANSI Class 150, Weld-Neck RF, CS
1 in. ANSI Class 150, Weld-Neck RF, SST
1 in. ANSI Class 300, Weld-Neck RF, CS
1 in. ANSI Class 300, Weld-Neck RF, SST
1 in. ANSI Class 600, Weld-Neck RF, CS
1 in. ANSI Class 600, Weld-Neck RF, SST
DIN 25 PN 16, CS
DIN 25 PN 16, 316 SST
DIN 25 PN 40, CS
DIN 25 PN 40, 316 SST
DIN 25 PN 100, CS
DIN 25 PN 100, 316 SST
Code
DP Ranges
0
1
2
3
Code
ProBar®
A
Code
1
2
Code
A
B
C
Code
D
J
K
L
M
Output
4–20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 1/2—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Housing Material
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Aluminum G1/2
Code
Opposite Side Support (Required for Model 16S ONLY)
MS2C0
MS2CW
MS2S0
MS2SW
Contoured Weld Fitting and Plug, 1/2—14 NPT, CS
Contoured Weld Fitting and Plug, 1/2 in., Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1/2—14 NPT, SST
Contoured Weld Fitting and Plug, 1/2 in., Socket Weld Port, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Code
Optional Manifolds
3
5
6
7
8
1
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
L
M
Z
Flow-282
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Rosemount Inc.
MODEL PBF+15S/16S
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QM8
QT1
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
EN 10204 3.1B Material Certs
Hydrostatic Test EP-4017
Extended Hydro EP-4046
ProBar®
Typical Model Number PBF+15S 020 HAMS0 C0000 FA4S0 FA4C 1 A 1 A
Flow-283
ProBar® Flowmeter
MODEL PBF+25S/26S
Model
PBF+25S
PBF+26S
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
ProBar®
Flow-284
Product Description
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
Direct and Integral Mount Heads
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
Direct Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATS0
HATSB
HATSD
HATSN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0
HA2SS
HP2S0
HP2SS
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in., Socket Weld Port, SST
Parallel, Horizontal Line,1/2—14 NPT, SST
Parallel, Horizontal Line, 1/2 in., Socket Weld Port, SST
HPVS0
HPVSS
HV2S0
HV2SS
Parallel, Vertical Line,1/2 in., Socket Weld Port, SST
Parallel, Vertical Line,1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in., Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple,1/2—14 NPT, CS
Needle Valve, Nipple and Tee,1/2—14 NPT, CS
Needle Valve, Elbow, 1/2— 14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
CP2SS
SP2S0
SP2SS
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Elbow, 1/2 in., Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple, 1/2 in., Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2 in., Socket Weld Port, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Rosemount Inc.
MODEL PBF+25S/26S
CB2SS
CC2S0
CC2SS
SC2S0
SV2S0
SV2SS
CB2S0
SB2S0
Instrument Connections (Continued)
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Elbow, 1/2 in., Socket Weld Port, SST
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple, 1/2 in., Socket Weld Port, SST
Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in., Socket Weld Port, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Code
Sensor Flange
FNPS0
FLPS0
FJPS0
FC6S0
FB6S0
FA6S0
DIN 40 PN 100, 316 SST
DIN 40 PN 40, 316 SST
DIN 40 PN 16, 316 SST
11/2 in. ANSI Class 600, RF, SST
11/2 in. ANSI Class 300, RF, SST
11/2 in. ANSI Class 150, RF, SST
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
FJPC
FJPS
FLPC
FLPS
FNPC
FNPS
11/2 in. ANSI Class 150, Weld-Neck RF, CS
11/2 in. ANSI Class 150, Weld-Neck RF, SST
11/2 in. ANSI Class 300, Weld-Neck RF, CS
11/2 in. ANSI Class 300, Weld-Neck RF, SST
11/2 in. ANSI Class 600, Weld-Neck RF, CS
11/2 in. ANSI Class 600, Weld-Neck RF, SST
DIN 40 PN 16, CS
DIN 40 PN 16, 316 SST
DIN 40 PN 40, CS
DIN 40 PN 40, 316 SST
DIN 40 PN 100, CS
DIN 40 PN 100, 316 SST
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 1/2—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G1/2
Code
Opposite Side Support (Required for Model 26S ONLY)
MS4C0
MS4CW
MS4S0
MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CS
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
ProBar®
Code
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Flow-285
ProBar® Flowmeter
MODEL PBF+25S/26S
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
ProBar®
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QM8
QT1
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
EN 10204 3.1B Material Certs
Hydrostatic Test EP-4017
Extended Hydro EP-4046
Typical Model Number PBF+25S 040 HAMS0 C0000 FA6S0 FA6C 1 A 1 A
Flow-286
Rosemount Inc.
MODEL PBF+25H/26H
PBF+25H
PBF+26H
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C
Integral, with 3-Valve Manifold, Horizontal Line, Hastelloy-C
Direct Mount, No Manifold, Horizontal Line, Hastelloy-C
HATH0
HATHB
HATHD
HATHN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C
Integral, with 3-Valve Manifold, Vertical Line, Hastelloy-C
Direct Mount, No Manifold, Vertical Line, Hastelloy-C
HVTH0
HVTHB
HVTHD
HVTHN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
HA2H0
HA2HS
HP2H0
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, Hastelloy-C
Axial, Horizontal Line, 1/2 in., Socket Weld Port, Hastelloy-C
Parallel, Horizontal Line,1/2—14 NPT, Hastelloy-C
HPVH0
HV2H0
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CA2H0
CP2H0
Needle Valve - Hastelloy
Needle Valve, Elbow, 1/2—14 NPT, Hastelloy-C
Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 11/2—14 NPT, CS
Outside Stem and Yoke Gate, Vertical Line, Nipple and Tee, 1/2—14 NPT,CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT,CS
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
ProBar®
Code
Flow-287
ProBar® Flowmeter
MODEL PBF+25H/26H
ProBar®
Code
Instrument Connections (Continued)
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Code
Sensor Flange
FC6H0
FB6H0
FA6H0
11/2 in. ANSI Class 600, RF, Hastelloy-C
11/2 in. ANSI Class 300, RF, Hastelloy-C
11/2 in. ANSI Class 150, RF, Hastelloy-C
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS
11/2 in. ANSI Class 150, Weld-Neck RF, SST
11/2 in. ANSI Class 300, Weld-Neck RF, CS
11/2 in. ANSI Class 300, Weld-Neck RF, SST
11/2 in. ANSI Class 600, Weld-Neck RF, CS
11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
0 -.5 to 0 - 25 inH20 (0-.12 to 0-6.22 kPa)
0 - 2.5 to 0 - 250 inH20 (0 -.62 to 0 - 62.2 kPa)
0 - 10 to 0 - 830 inH20 (0 - 2.48 to 0 - 206 kPa)
Output
4— 20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum 1/2—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G1/2
Code
Opposite Side Support (Required for Model 26H ONLY)
MS4CW
MS4S0
MS4SW
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
3
5
6
7
8
Code
K
Code
1
2
4
Flow-288
Valve, Nipple, 1/2—14 NPT, SST
Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee,1/2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Rosemount Inc.
MODEL PBF+25H/26H
I5
C6
E5
K5
ID
ED
Code
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
Code
Typical Model Number PBF+25H 040 HAMH0 C0000 FA6H0 FA6C 1 A 1 A
Flow-289
ProBar® Flowmeter
MODEL PBF+25M/26M
Model
PBF+25M
PBF+26M
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
ProBar®
Flow-290
Product Description
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADM0
HADMB
HADMN
HAMM0
HAPM0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, B31.1,Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Monel
Integral, 3-Valve Manifold, Horizontal Line, Monel
Direct Mount, No Manifold, Horizontal Line, Monel
HATM0
HATMB
HATMD
HATMN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount,5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with5-Valve Manifold, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, B31.1,Vertical Line, Monel
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
Integral, 3-Valve Manifold, Vertical Line, Monel
Direct Mount, No Manifold, Vertical Line, Monel
HVTM0
HVTMB
HVTMD
HVTMN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD,B31.1,Vertical Line, Monel
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0
HA2MS
HP2M0
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, Monel
Axial, Horizontal Line, ½ in.,
Socket Weld Port, Monel
Parallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0
HV2M0
HV2MS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2—14 NPT, Monel
Axial, Vertical Line, 1/2—14 NPT, Monel
Axial, Vertical Line, ½ in., Socket Weld Port, Monel
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and
Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2M0
CA2M0
Needle Valve - Monel
Needle Valve, Nipple, 1/2—14 NPT, Monel
Needle Valve, Elbow, 1/2—14 NPT, Monel
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Yoke, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Rosemount Inc.
MODEL PBF+25M/26M
Code
Instrument Connections (Continued)
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Code
Sensor Flange
1½ in. ANSI Class 600, RF, Monel
1½ in. ANSI Class 300, RF, Monel
1½ in. ANSI Class 150, RF, Monel
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
1½ in. ANSI Class
1½ in. ANSI Class
1½ in. ANSI Class
1½ in. ANSI Class
1½ in. ANSI Class
1½ in. ANSI Class
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
0 -.5 to 0 - 25 inH20 (0 -.12 to 0 - 6.22 kPa)
0 - 2.5 to 0 - 250 inH20 (0 -.62 to 0 - 62.2kPa)
0 - 10 to 0 - 830 inH20 (0 - 2.48 to 0 - 206kPa)
Output
4–20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G½
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Code
Opposite Side Support (Required for Model 26M ONLY)
MS4CW
MS4S0
MS4SW
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
ProBar®
FC6M0
FB6M0
FA6M0
Valve, Nipple, 1/2—14 NPT, SST
Vertical Line, Nipple and Tee, Steam,1 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, /2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Flow-291
ProBar® Flowmeter
MODEL PBF+25M/26M
Code
I5
C6
E5
K5
ID
ED
Code
ProBar®
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material - Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBF+25M 040 HAMM0 C0000 FA6M0 FA6C 1 A 1 A
Flow-292
Rosemount Inc.
MODEL PBF+35S/36S
PBF+35S
PBF+36S
Code
080
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Description
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
Direct Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATS0
HATSB
HATSD
HATSN
Direct and Integral Mount Heads - Horizontal Line With RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line With RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, ½ in., Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, ½ in., Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, ½ in., Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, ½ in., Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CA2S0
SA2S0
CP2SS
SP2SS
Needle Valve - SST
Needle Valve, Elbow, ½ in., Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple, ½ in., Socket Weld Port, SST
Needle Valve, Nipple and Tee, ½ in., Socket Weld Port, SST
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
ProBar®
Model
Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Flow-293
ProBar® Flowmeter
MODEL PBF+35S/36S
Code
SC2S0
SV2S0
CB2S0
SB2S0
CB2SS
CC2SS
SV2SS
Code
FNRS0
FLRS0
FJRS0
FC8S0
FB8S0
FA8S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Valve, Elbow, ½ in., Socket Weld Port, SST
Valve, Nipple, ½ in., Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, ½ in., Socket Weld Port, SST
Sensor Flanges
DIN 50 PN 100, 316 SST
DIN 50 PN 40, 316 SST
DIN 50 PN 16, 316 SST
2 in. ANSI Class 600, RF, SST
2 in. ANSI Class 300, RF, SST
2 in. ANSI Class 150, RF, SST
ProBar®
Code
Flanged Mount
FA8C
FA8S
FB8C
FB8S
FC8C
FC8S
FJRC
FJRS
FLRC
FLRS
FNRC
FNRS
2 in. ANSI Class 150, Weld-Neck RF, CS
2 in. ANSI Class 150, Weld-Neck RF, SST
2 in. ANSI Class 300, Weld-Neck RF, CS
2 in. ANSI Class 300, Weld-Neck RF, SST
2 in. ANSI Class 600, Weld-Neck RF, CS
2 in. ANSI Class 600, Weld-Neck RF, SST
DIN 50 PN 16, CS
DIN 50 PN 16, 316 SST
DIN 50 PN 40, CS
DIN 50 PN 40, 316 SST
DIN 50 PN 100, CS
DIN 50 PN 100, 316 SST
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MS6C0
MS6CW
MS6S0
MS6SW
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4–20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Opposite Side Support (Required for Model 36S ONLY)
Contoured Weld Fitting and Plug, 1½—11.5 NPT, CS
Contoured Weld Fitting and Plug, 1½ in., Socket Weld Port, CS
Contoured Weld Fitting and Plug, 1½—11.5 NPT, SST
Contoured Weld Fitting and Plug, 1½ in., Socket Weld Port, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
1
Flow-294
Instrument Connections (Continued)
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Rosemount Inc.
MODEL PBF+35S/36S
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
Code
Typical Model Number PBF+35S 120 HAMS0 C0000 FA8S0 FA8C 1 A 1 A
Flow-295
ProBar® Flowmeter
MODEL PBF+45S/46S
Model
PBF+45S
PBF+46S
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
ProBar®
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
Direct Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATS0
HATSB
HATSD
HATSN
Direct and Integral Mount Heads - Horizontal Line With RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line With RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
HSHS0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, ½ in., Socket Weld Port, SST
Axial, Horizontal Line, ½ in.—14 NPT, SST
Axial, Horizontal Line, ½ in., Socket Weld Port, SST
Parallel, Horizontal Line,½ in.—14 NPT, SST
Stack Head with Purge, Horizontal Line, ½ in.—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
HSVS0
Parallel, Vertical Line, ½ in., Socket Weld Port, SST
Parallel, Vertical Line, ½ —14 NPT, SST
Axial, Vertical Line, ½—14 NPT, SST
Axial, Vertical Line, ½ in., Socket Weld Port, SST
Stack Head with Purge, Vertical Line, ½—14 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, ½—14 NPT, CS
Needle Valve, Nipple and Tee, ½—14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CC2C0
SC2C0
SV2C0
Flow-296
Product Description
Needle Valve - SST
Needle Valve, Elbow, ½ in., Socket Weld Port, SST
Needle Valve, Nipple, ½—14 NPT, SST
Needle Valve, Nipple and Tee, ½—14 NPT, SST
Needle Valve, Nipple, ½ in., Socket Weld Port, SST
Needle Valve, Nipple and Tee, ½ in., Socket Weld Port, SST
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CS
Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, ½—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
Rosemount Inc.
MODEL PBF+45S/46S
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
Code
FBDS0
FNTS0
FLTS0
FJTS0
FCDS0
FADS0
Instrument Connections (Continued)
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, ½—14 NPT, SST
Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Valve, Elbow, ½ in., Socket Weld Port, SST
Valve, Nipple, ½ in., Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, ½ in., Socket Weld Port, SST
Sensor Flanges
3 in. ANSI Class 300, RF, SST
DIN 80 PN 100, 316 SST
DIN 80 PN 40, 316 SST
DIN 80 PN 16, 316 SST
3 in. ANSI Class 600, RF, SST
3 in. ANSI Class 150, RF, SST
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
FJTC
FJTS
FLTC
FLTS
FNTC
FNTS
3 in. ANSI Class 150, Weld-Neck RF, CS
3 in. ANSI Class 150, Weld-Neck RF, SST
3 in. ANSI Class 300, Weld-Neck RF, CS
3 in. ANSI Class 300, Weld-Neck RF, SST
3 in. ANSI Class 600, Weld-Neck RF, CS
3 in. ANSI Class 600, Weld-Neck RF, SST
DIN 80 PN 16, CS
DIN 80 PN 16, 316 SST
DIN 80 PN 40, CS
DIN 80 PN 40, 316 SST
DIN 80 PN 100, CS
DIN 80 PN 100, 316 SST
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Opposite Side Support (Required for Model 46S ONLY)
Contoured Weld Fitting and Cap, 3 in., BW, CS
Contoured Weld Fitting and Cap, 3 in., BW, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
ProBar®
Code
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Flow-297
ProBar® Flowmeter
MODEL PBF+45S/46S
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
ProBar®
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBF+45S 240 HAMS0 C0000 FADS0 FADC 1 A 1 A
Flow-298
Rosemount Inc.
MODEL PBF+45H/46H
PBF+45H
PBF+46H
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Description
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C
Integral, with 3-Valve Manifold, Horizontal Line, Hastelloy-C
Direct Mount, No Manifold, Horizontal Line, Hastelloy-C
HATH0
HATHB
HATHD
HATHN
Direct and Integral Mount Heads - Horizontal Line With RTD
Integral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold,RTD,B31.1, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C
Integral, with 3-Valve Manifold, Vertical Line, Hastelloy-C
Direct Mount, No Manifold, Vertical Line, Hastelloy-C
HVTH0
HVTHB
HVTHD
HVTHN
Direct and Integral Mount Heads - Vertical Line With RTD
Integral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, B31.1,Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
HA2H0
HA2HS
HP2H0
Remote Mount - Horizontal Line
Axial, Horizontal Line, ½—14 NPT, Hastelloy-C
Axial, Horizontal Line, ½ in., Socket Weld Port, Hastelloy-C
Parallel, Horizontal Line, ½—14 NPT, Hastelloy-C
HPVH0
HV2H0
HSVH0
Remote Mount - Vertical Line
Parallel, Vertical Line, ½—14 NPT, Hastelloy-C.
Axial, Vertical Line, ½—14 NPT, Hastelloy-C.
Stack head with purge, Vertical Line, ½—14 NPT, Hastelloy-C
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, ½—14 NPT, CS
Needle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0
SP2S0
Needle Valve - SST
Needle Valve, Nipple, ½—14 NPT, SST
Needle Valve, Nipple and Tee, ½—14 NPT, SST
CP2H0
Needle Valve - Hastelloy
Needle Valve, Nipple, ½—14 NPT, Hastelloy-C
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CS
Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, ½—14 NPT½—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0
SC2S0
SV2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SST
Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code
Sensor Flanges
FCDH0
FBDH0
FADH0
ProBar®
Model
3 in. ANSI Class 600, RF, Hastelloy-C
3 in. ANSI Class 300, RF, Hastelloy-C
3 in. ANSI Class 150, RF, Hastelloy-C
Flow-299
ProBar® Flowmeter
MODEL PBF+45H/46H
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
Code
DP Ranges
1
2
3
Code
A
Code
1
2
ProBar®
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Opposite Side Support (Required for Model 46H ONLY)
Contoured Weld Fitting and Cap, 3 in., BW, CS
Contoured Weld Fitting and Cap, 3 in., BW, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Flow-300
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Rosemount Inc.
MODEL PBF+45H/46H
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBF+45H 240 HAMH0 C0000 FADH0 FADC 1 A 1 A
ProBar®
Code
Flow-301
ProBar® Flowmeter
MODEL PBF+45M/46M
Model
PBF+45M
PBF+46M
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
ProBar® + Flowmeter - Flanged
ProBar® + Flowmeter - Flanged with Opposite Side Support
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
ProBar®
HADM0
HADMB
HADMN
HAMM0
HAPM0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Monel
Integral, 3-Valve Manifold, Horizontal Line, Monel
Direct Mount, No Manifold, Horizontal Line, Monel
HATM0
HATMB
HATMD
HATMN
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
Integral, 3-Valve Manifold, Vertical Line, Monel
Direct Mount, No Manifold, Vertical Line, Monel
HVTM0
HVTMB
HVTMD
HVTMN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, Monel
Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0
HA2MS
HP2M0
Remote Mount - Horizontal Line
Axial, Horizontal Line, ½—14 NPT, Monel
Axial, Horizontal Line, ½ in., Socket Weld Port, Monel
Parallel, Horizontal Line, ½—14 NPT, Monel
HPVM0
HV2M0
HV2MS
HSVM0
Remote Mount - Vertical Line
Parallel, Vertical Line, ½—14 NPT, Monel
Axial, Vertical Line, ½—14 NPT, Monel
Axial, Vertical Line, ½ in., Socket Weld Port, Monel
Stack Head with Purge, Vertical Line, ½—14 NPT, Monel
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, ½—14 NPT, CS
Needle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0
SP2S0
Needle Valve - SST
Needle Valve, Nipple, ½—14 NPT, SST
Needle Valve, Nipple and Tee, ½—14 NPT, SST
CP2M0
Needle Valve - Monel
Needle Valve, Nipple, ½—14 NPT, Monel
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CS
Outside Stem and Yoke Gate, Vertical Line, Nipple and Tee, ½—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0
SC2S0
SV2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SST
Outside Stem and Yoke Gate, Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code
Sensor Flanges
FCDM0
FBDM0
FADM0
Flow-302
Product Description
3 in. ANSI Class 600, RF, Monel
3 in. ANSI Class 300, RF, Monel
3 in. ANSI Class 150, RF, Monel
Rosemount Inc.
MODEL PBF+45M/46M
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
Code
DP Ranges
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Code
MSDCW
MSDSW
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Opposite Side Support (Required for Model 46M ONLY)
Contoured Weld Fitting and Cap, 3 in., BW, CS
Contoured Weld Fitting and Cap, 3 in., BW, SST
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion–Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion–Proof, Axial
Integral RTD, Explosion–Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
ProBar®
1
2
3
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion–Proof and Intrinsic Safety Approval
FM Explosion–Proof Approval
FM Explosion–Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion–Proof Approval
Flow-303
ProBar® Flowmeter
MODEL PBF+45M/46M
Code
L
M
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
ProBar®
Flow-304
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in. to 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in. to 16 in.)
Multipoint Flow Calibration (18 in. to 20 in.)
Lab Flow Calibration (Average K) (18 in. to 20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA2
Q21
Q23
Q29
QJ2
QM2
QT2
QT8
Certified Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PBF+45M 240 HAMM0 C0000 FADM0 FADC 1 A 1 A
ProBar®
Rosemount Inc.
Flow-305
ProBar® Flowmeter
ProBar®
306
Flow-306
ProBar®
Rosemount Inc.
Flow-307
ProBar® Flowmeter
ProBar®
308
Flow-308
ProBar®
Rosemount Inc.
Flow-309
ProBar® Flowmeter
Ordering Information—Model PNT
MODEL PNT+10S
Model
PNT+10S
Code
005
007
010
012
015
020
Code
ProBar® + Flowmeter - In-line Threaded
Line Size
½ in. (12.5 mm)
¾ in. (19 mm)
1 in. (25 mm)
1¼ in. (31 mm)
1½ in. (37.5 mm)
2 in. (50 mm)
Fittings
Ordering
HAMS0
HADS0
HADSB
HADSN
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
Direct and Integral Mount Heads - Vertical Line
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HF1SS
HM1S0
Remote Mount
Fittings, ¼ in. Socket Weld Ports, SST
Fittings, ¼—18 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, ¼—18 NPT, CS
Needle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0
SP1S0
Needle Valve - SST
Needle Valve, Nipple, ¼—18 NPT, SST
Needle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0
SB1S0
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-310
Product Description
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Rosemount Inc.
MODEL PNT+10S
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
3
5
6
7
8
Optional Mounting Brackets
1
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Certificate
KEMA/CENELEC Explosion-Proof Approval
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
Code
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Typical Model Number PNT+10S 010 HAMS0 C0000 1 A 1 A
Flow-311
ProBar® Flowmeter
Ordering Information—Model PNF
MODEL PNF+10S
Model
PNF+10S
Code
005
007
010
012
015
020
Code
ProBar® + Flowmeter - In-line Flanged
Line Size
½ in. (12.5 mm)
¾ in. (19 mm)
1 in. (25 mm)
1¼ in. (31 mm)
1½ in. (37.5 mm)
2 in. (50 mm)
Fittings
ProBar®
HAMS0
HADS0
HADSB
HADSN
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
Direct and Integral Mount Heads - Vertical Line
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HF1SS
HM1S0
Remote Mount
Fittings, ¼ in. Socket Weld Ports, SST
Fittings, ¼—18 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, ¼—18 NPT, CS
Needle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0
SP1S0
Needle Valve - SST
Needle Valve, Nipple, ¼—18 NPT, SST
Needle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code
Flanged Mount
FAS
FBS
FCS
FJS
FLS
FNS
Code
0
1
2
3
Code
A
Code
1
2
Flow-312
Product Description
ANSI Class 150, Weld-Neck RF, SST
ANSI Class 300, Weld-Neck RF, SST
ANSI Class 600, Weld-Neck RF, SST
DIN PN 16, SST
DIN PN 40, SST
DIN PN 100, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4–20 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Rosemount Inc.
MODEL PNF+10S
A
B
C
D
J
K
L
M
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
3
5
6
7
8
Code
1
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
ProBar®
Code
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Certificate
KEMA/CENELEC Explosion-Proof Approval
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number PNF+10S 010 HAMS0 C0000 FAS 1 A 1 A
Flow-313
ProBar® Flowmeter
MODEL PNF+10H
Model
PNF+10H
Code
005
007
010
012
015
020
Code
ProBar® + Flowmeter - In-line Flanged
Line Size
½ in. (12.5 mm)
¾ in. (19 mm)
1 in. (25 mm)
1¼ in. (31 mm)
1½ in. (37.5 mm)
2 in. (50 mm)
Fittings
ProBar®
HADH0
HADHN
HAMH0
HAPH0
HADHB
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C
Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C
Direct Mount, No Manifold, Horizontal Line, Hastelloy-C
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
HVDH0
HVDHN
HVMH0
HVPH0
HVDHB
Direct and Integral Mount Heads - Vertical Line
Direct Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-C
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C
Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C
Direct Mount, No Manifold, Vertical Line, Hastelloy-C
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
HM1H0
Remote Mount
Fittings, ¼—18 NPT, Hastelloy-C
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, ¼—18 NPT, CS
Needle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0
SP1S0
Needle Valve - SST
Needle Valve, Nipple, ¼—18 NPT, SST
Needle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code
Flanged Mount
FAH
FBH
FCH
ANSI Class 150, Weld-Neck RF, Hastelloy-C
ANSI Class 300, Weld-Neck RF, Hastelloy-C
ANSI Class 600, Weld-Neck RF, Hastelloy-C
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-314
Product Description
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 in H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 in H2O (0-2.48 to 0-206 kPa)
Output
4–20 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Rosemount Inc.
MODEL PNF+10H
3
5
6
7
8
Code
1
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Certificate
KEMA/CENELEC Explosion-Proof Approval
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
Code
Typical Model Number PNF+10H 010 HAMH0 C0000 FAH 1 A 1 A
Flow-315
ProBar® Flowmeter
MODEL PNF+10M
Model
PNF+10M
Code
005
007
010
012
015
020
Code
ProBar® + Flowmeter - In-line Flanged
Line Size
½ in. (12.5 mm)
¾ in. (19 mm)
1 in. (25 mm)
1¼ in. (31 mm)
1½ in. (37.5 mm)
2 in. (50 mm)
Fittings
ProBar®
HADMN
HADM0
HADMB
HAMM0
HAPM0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, Horizontal Line, Monel
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Monel
Integral, 3-Valve Manifold, Horizontal Line, Monel
Direct Mount, No Manifold, Horizontal Line, Monel
HVDMN
HVDM0
HVDMB
HVMM0
HVPM0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
Direct Mount, with 5-Valve Manifold, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, Monel
Integral, 3-Valve Manifold, Vertical Line, Monel
Direct Mount, No Manifold, Vertical Line, Monel
HM1M0
Remote Mount
Fittings, ¼—18 NPT, Monel
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, ¼—18 NPT, CS
Needle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0
SP1S0
Needle Valve - SST
Needle Valve, Nipple, ¼—18 NPT, SST
Needle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code
Flanged Mount
FAM
FBM
FCM
ANSI Class 150, Weld-Neck RF, Monel
ANSI Class 300, Weld-Neck RF, Monel
ANSI Class 600, Weld-Neck RF, Monel
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-316
Product Description
0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 in H2O (0-.62 to 0-62.2 kPa)
0-10 to 0-830 in H2O (0-2.48 to 0-206 kPa)
Output
4–20 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Rosemount Inc.
MODEL PNF+10M
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
Code
1
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Certificate
KEMA/CENELEC Explosion-Proof Approval
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
3
5
6
7
8
Typical Model Number PNF+10M 010 HAMM0 C0000 FAM 1 A 1 A
Flow-317
ProBar® Flowmeter
Ordering Information—Model PNW
MODEL PNW+10S
Model
PNW+10S
Code
005
007
010
012
015
020
Code
ProBar® + Flowmeter - In-line Butt Weld
Line Size
½ in. (12.5 mm)
¾ in. (19 mm)
1 in. (25 mm)
1¼ in. (31 mm)
1½ in. (37.5 mm)
2 in. (50 mm)
Fittings
ProBar®
HAMS0
HADS0
HADSB
HADSN
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
Direct and Integral Mount Heads - Vertical Line
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, with 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HF1SS
HM1S0
Remote Mount
Fittings, ¼ in. Socket Weld Ports, SST
Fittings, ¼—18 NPT, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP1C0
SP1C0
Needle Valve - CS
Needle Valve, Nipple, ¼—18 NPT, CS
Needle Valve, Nipple and Tee, ¼—18 NPT, CS
CP1S0
SP1S0
Needle Valve - SST
Needle Valve, Nipple, ¼—18 NPT, SST
Needle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0
SB1S0
Gate Valve
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-318
Product Description
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4–20 mA with Digital Signal Based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly-Aluminum ½—14 NPT
Epoxy-Poly-Aluminum CM 20
Epoxy-Poly-Aluminum PG 13.5
Epoxy-Poly-Aluminum G½
316 SST ½—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly-Aluminum G½
Rosemount Inc.
MODEL PNW+10S
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
Code
1
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Model 305 Manifold Bolted to Transmitter
5-Valve Manifold, CS
5-Valve Manifold, SST
3-Valve Manifold, CS
3-Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate) - Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Certificate
KEMA/CENELEC Explosion-Proof Approval
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
ProBar®
3
5
6
7
8
Typical Model Number PNW+10S 010 HAMS0 C0000 1 A 1 A
Flow-319
ProBar® Flowmeter
ProBar®
320
Flow-320
ProBar®
Rosemount Inc.
Flow-321
ProBar® Flowmeter
ProBar®
322
Flow-322
ProBar®
Rosemount Inc.
Flow-323
ProBar® Flowmeter
ProBar®
324
Flow-324
Rosemount Inc.
Ordering Information—Model PHT
MODEL PHT+15S
PHT+15S
Code
020
025
030
035
040
050
Code
Product Description
ProBar® + Flowmeter - Threaded Flo-Tap
Line Size
2 in. (50 mm)
21/2 in. (63.5 mm)
3 in. (80 mm)
31/2 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HAMS0
HADS0
HADSB
HADSN
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
Direct and Integral Mount Heads - Vertical Line
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Code
GV3S0
GV3C0
GH3S0
GH3C0
ProBar®
Model
Packing Gland
Graphite, 3/4—14 NPT, SST
Graphite, 3/4—14 NPT, CS
Urethane, 3/4—14 NPT, SST
Urethane, 3/4—14 NPT, CS
Flow-325
ProBar® Flowmeter
MODEL PHT+15S
Code
Insert/Retract
IHRS
IHRC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Code
Isolation Valve
VT3SG
VT3CG
Gate Valve
Gate Valve, 3/4—14 NPT, SST
Gate Valve, 3/4—14 NPT, CS
VT3SB
VT3CB
Ball Valve
Ball Valve, 3/4—14 NPT, SST
Ball Valve, 3/4—14 NPT, CS
Code
Mounting Hardware
MH3C0
MH3S0
Code
ProBar®
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
L
M
Z
Flow-326
Weld Coupling and Nipple, 3/4—14 NPT, CS
Weld Coupling and Nipple, 3/4—14 NPT, SST
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Rosemount Inc.
MODEL PHT+15S
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
PHT+15S 020 HAMS0 C0000 GV3S0 IHRC VT3CG MH3C0 2 A 1 A
ProBar®
Typical Model Number:
Flow-327
ProBar® Flowmeter
MODEL PHT+25S
Model
PHT+25S
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
ProBar®
Flow-328
Product Description
ProBar® + Flowmeter - Threaded Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HAMS0
HADS0
HADSB
HADSN
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATSN
HATS0
HATSD
HATSB
Direct and Integral Mount Heads - Horizontal Line with RTD
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, SST
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
Direct and Integral Mount Heads - Vertical Line
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Rosemount Inc.
MODEL PHT+25S
Instrument Connections (Continued)
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Code
GV5S0
GV5C0
GH5S0
GH5C0
Packing Gland
Graphite, 11/4—11.5 NPT, SST
Graphite, 11/4—11.5 NPT, CS
Urethane, 11/4—11.5 NPT, SST
Urethane, 11/4—11.5 NPT, CS
Code
Insert/Retract
IHRS
IHRC
IHDS
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Code
Isolation Valve
VT5SG
VT5CG
Gate Valve
Gate Valve, 11/4—11.5 NPT, SST
Gate Valve, 11/4—11.5 NPT, CS
VT5SB
VT5CB
Ball Valve
Ball Valve, 11/4—11.5 NPT, SST
Ball Valve, 11/4—11.5 NPT, CS
Code
Mounting Hardware
MH5C0
MH5S0
Code
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
ProBar®
Code
Weld Coupling and Nipple, 11/4—11.5 NPT, CS
Weld Coupling and Nipple, 11/4—11.5 NPT, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Flow-329
ProBar® Flowmeter
MODEL PHT+25S
Code
3
5
6
7
8
9
Code
K
Code
1
2
4
Code
ProBar®
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Special Manifold
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
Flow-330
PHT+25S 040 HAMS0 C0000 GV5SO IHRC VT5CG MH5C0 2 A 1 A
Rosemount Inc.
MODEL PHT+35S
PHT+35S
Code
100
120
140
160
180
200
240
300
340
360
420
480
600
720
Code
Product Description
ProBar® + Flowmeter - Threaded Flo-Tap
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
34 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(864 mm)
(900 mm)
(1066 mm)
(1210 mm)
(1520 mm)
(1820 mm)
Head Style
HAMS0
HADS0
HADSB
HADSN
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATSN
HATS0
HATSD
HATSB
Direct and Integral Mount Heads - Horizontal Line with RTD
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, SST
HVMS0
HVDS0
HVDSB
HVDSN
HVPS0
Direct and Integral Mount Heads - Vertical Line
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
ProBar®
Model
Flow-331
ProBar® Flowmeter
MODEL PHT+35S
Code
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Code
ProBar®
GV8S0
GV8C0
GH8S0
GH8C0
Packing Gland
Graphite, 2—11.5 NPT, SST
Graphite, 2—11.5 NPT, CS
Urethane, 2—11.5 NPT, SST
Urethane, 2—11.5 NPT, CS
Code
Insert/Retract
IHRS
IHRC
I990
IHDS
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Special Insert/Retract Assembly
Gear, Dual, SST Rods
Code
Isolation Valves
VT8SG
VT8CG
Gate Valve
Gate Valve, 2—11.5 NPT, SST
Gate Valve, 2—11.5 NPT, CS
VT8SB
VT8CB
Ball Valve
Ball Valve, 2—11.5 NPT, SST
Ball Valve, 2—11.5 NPT, CS
Code
Mounting Hardware
MH8C0
MH8S0
Code
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-332
Instrument Connections (Continued)
Weld Coupling and Nipple, 2—11.5 NPT, CS
Weld Coupling and Nipple, 2—11.5 NPT, SST
DP Ranges
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Rosemount Inc.
MODEL PHT+35S
3
5
6
7
8
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
ProBar®
Code
PHT+35S 120 HAMS0 C0000 GV8C0 IHDS VT8CG MH8C0 2 A 1 A
Flow-333
ProBar® Flowmeter
ProBar®
334
Flow-334
ProBar®
Rosemount Inc.
Flow-335
ProBar® Flowmeter
ProBar®
336
Flow-336
ProBar®
Rosemount Inc.
Flow-337
ProBar® Flowmeter
ProBar®
338
Flow-338
ProBar®
Rosemount Inc.
Flow-339
ProBar® Flowmeter
Ordering Information—Model PHF
MODEL PHF+15S
Model
PHF+15S
Code
020
025
030
035
040
050
Code
ProBar®
Flow-340
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
2 in. (50 mm)
21/2 in. (63.5 mm)
3 in. (80 mm)
31/2 in. (89 mm)
4 in. (100 mm)
5 in. (125 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
Direct and Integral Head Mount - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Head Mount - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections)
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CP2SS
SP2SS
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
Rosemount Inc.
MODEL PHF+15S
GV4SC
GV4SB
GV4SA
GH4SC
GH4SB
GH4SA
Packing Gland
Graphite, 1 in. ANSI Class 600, SST
Graphite, 1 in. ANSI Class 300, SST
Graphite, 1 in. ANSI Class 150, SST
Urethane, 1 in. ANSI Class 600, SST
Urethane, 1 in. ANSI Class 300, SST
Urethane, 1 in. ANSI Class 150, SST
Code
Insert/Retract
IHRS
IHRC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Code
Isolation Valve
VC4SG
VC4CG
VB4SG
VB4CG
VA4SG
VA4CG
Gate Valve
Gate Valve,
Gate Valve,
Gate Valve,
Gate Valve,
Gate Valve,
Gate Valve,
VB4SB
VB4CB
VA4SB
VA4CB
Ball Valve
Ball Valve, 1 in.
Ball Valve, 1 in.
Ball Valve, 1 in.
Ball Valve, 1 in.
1 in. ANSI Class
1 in. ANSI Class
1 in. ANSI Class
1 in. ANSI Class
1 in. ANSI Class
1 in. ANSI Class
FA4C
FA4S
FB4C
FB4S
FC4C
FC4S
Other
1 in. ANSI
1 in. ANSI
1 in. ANSI
1 in. ANSI
1 in. ANSI
1 in. ANSI
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
600, SST
600, CS
300, SST
300, CS
150, SST
150, CS
ANSI Class 300, SST
ANSI Class 300, CS
ANSI Class 150, SST
ANSI Class 150, CS
Class 150, Weld-Neck RF, CS
Class 150, Weld-Neck RF, SST
Class 300, Weld-Neck RF, CS
Class 300, Weld-Neck RF, SST
Class 600, Weld-Neck RF, CS
Class 600, Weld-Neck RF, SST
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Code
Optional Manifolds
3
5
6
7
8
9
Code
K
ProBar®
Code
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Special Manifold
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Flow-341
ProBar® Flowmeter
MODEL PHF+15S
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
L
M
Z
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
ProBar®
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
Flow-342
PHF+15S 020 HAMS0 C0000 GV4SA IHRS VA4CG 1 A 1 A
Rosemount Inc.
MODEL PHF+25S
PHF+25S
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
5 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATSN
HATS0
HATSD
Direct and Integral Mount Heads - Horizontal Line with RTD
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CA2S0
SA2S0
CP2SS
SP2SS
Needle Valve - SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
ProBar®
Model
Valve, Nipple, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Flow-343
ProBar® Flowmeter
MODEL PHF+25S
Code
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
CB2SS
CC2SS
SV2SS
Code
GV8SC
GV8SB
GV8SA
GH8SC
GH8SB
GH8SA
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Graphite, 2 in. ANSI Class 600
Graphite, 2 in. ANSI Class 300
Graphite, 2 in. ANSI Class 150
Urethane, 2 in. ANSI Class 600, SST
Urethane, 2 in. ANSI Class 300, SST
Urethane, 2 in. ANSI Class 150, SST
ProBar®
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VB8SG
VB8CG
VA8SG
VA8CG
Gate Valve
Gate Valve, 2 in.
Gate Valve, 2 in.
Gate Valve, 2 in.
Gate Valve, 2 in.
VB8SB
VB8CB
VA8SB
VA8CB
Ball Valve
Ball Valve, 2
Ball Valve, 2
Ball Valve, 2
Ball Valve, 2
ANSI Class 300,
ANSI Class 300,
ANSI Class 150,
ANSI Class 150,
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FA8C
FA8S
FB8C
FB8S
FC8C
FC8S
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
Code
DP Ranges
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Packing Gland
Code
0
1
2
3
Flow-344
Instrument Connections (Continued)
SST
CS
SST
CS
Class 300, SST
Class 300, CS
Class 150, SST
Class 150, CS
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Rosemount Inc.
MODEL PHF+25S
3
5
6
7
8
9
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Special Manifold
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
ProBar®
Code
PHF+25S 080 HADSO C0000 GV8SA IHRC VA8SG FA87C 2 A 1 A
Flow-345
ProBar® Flowmeter
MODEL PHF+25H
Model
PHF+25H
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
ProBar®
Flow-346
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADH0
HADHB
HADHN
HAMH0
HAPH0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C.
Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C.
Direct Mount, No Manifold, Horizontal Line, Hastelloy-C.
HATH0
HATHB
HATHD
HATHN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C.
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C.
Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C.
Direct Mount, No Manifold, Vertical Line, Hastelloy-C.
HVTH0
HVTHB
HVTHD
HVTHN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C.
HA2H0
HA2HS
HP2H0
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
Axial, Horizontal Line, 1/2 in. Socket Weld Port, Hastelloy-C.
Parallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HPVH0
HV2H0
Remote Mount - Horizontal Line
Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CA2H0
CP2H0
Needle Valve - Hastelloy
Needle Valve, Elbow, 1/2—14 NPT, Hastelloy-C.
Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C.
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
Rosemount Inc.
MODEL PHF+25H
Code
Instrument Connections (Continued)
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Code
Packing Gland
Graphite, 11/2 in.ANSI Class 600, Hastelloy-C.
Graphite, 11/2 in.ANSI Class 300, Hastelloy-C.
Graphite, 11/2 in.ANSI Class 150, Hastelloy-C.
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VC6SG
VC6CG
VB6SG
VB6CG
VA6SG
VA6CG
Gate Valve
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
VB6SB
VB6CB
VA6SB
VA6CB
Ball Valve
Ball Valve, 11/2 in.
Ball Valve, 11/2 in.
Ball Valve, 11/2 in.
Ball Valve, 11/2 in.
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS
11/2 in. ANSI Class 150, Weld-Neck RF, SST
11/2 in. ANSI Class 300, Weld-Neck RF, CS
11/2 in. ANSI Class 300, Weld-Neck RF, SST
11/2 in. ANSI Class 600, Weld-Neck RF, CS
11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Class
Class
Class
Class
Class
Class
600, SST
600, CS
300, SST
300, CS
150, SST
150, CS
ProBar®
GV6HC
GV6HB
GV6HA
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
ANSI Class 300, SST
ANSI Class 300, CS
ANSI Class 150, SST
ANSI Class 150, CS
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Flow-347
ProBar® Flowmeter
MODEL PHF+25H
Code
3
5
6
7
8
Code
K
Code
1
2
4
Code
ProBar®
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Manifolds
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
Flow-348
PHF+25H 040 HAMH0 C0000 GV6HA IHRC VA6CG FA6C 1 A 1 A
Rosemount Inc.
MODEL PHF+25M
PHF+25M
Code
040
050
060
080
100
120
140
160
180
200
240
300
360
420
Code
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
4 in. (100 mm)
5 in. (125 mm)
6 in. (150 mm)
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
Head Style
HADH0
HADM0
HADMB
HADMN
HAMM0
HAPM0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Monel
Integral, 3-Valve Manifold, Horizontal Line, Monel
Direct Mount, No Manifold, Horizontal Line, Monel
HATM0
HATMB
HATMD
HATMN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDH0
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
Integral, 3-Valve Manifold, Vertical Line, Monel
Direct Mount, No Manifold, Vertical Line, Monel
HVTM0
HVTMB
HVTMD
HVTMN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0
HA2MS
HP2M0
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, Monel
Axial, Horizontal Line, 1/2 in. Socket Weld Port, Monel
Parallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0
HV2M0
HV2MS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2—14 NPT, Monel
Axial, Vertical Line, 1/2—14 NPT, Monel
Axial, Vertical Line, 1/2 in. Socket Weld Port, Monel
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
CA2S0
SA2S0
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2M0
CA2M0
Needle Valve - Monel
Needle Valve, Nipple, 1/2—14 NPT, Monel
Needle Valve, Elbow, 1/2—14 NPT, Monel
ProBar®
Model
Flow-349
ProBar® Flowmeter
MODEL PHF+25M
Code
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Code
Packing Gland
GV6MC
GV6MB
GV6MA
Graphite, 11/2 in. ANSI Class 600, Monel
Graphite, 11/2 in. ANSI Class 300, Monel
Graphite, 11/2 in. ANSI Class 150, Monel
ProBar®
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VC6SG
VC6CG
VB6SG
VB6CG
VA6SG
VA6CG
Gate Valve
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
Gate Valve, 11/2 in. ANSI
VB6SB
VB6CB
VA6SB
VA6CB
Ball Valve
Ball Valve, 11/2 in.
Ball Valve, 11/2 in.
Ball Valve, 11/2 in.
Ball Valve, 11/2 in.
Code
Flanged Mount
FA6C
FA6S
FB6C
FB6S
FC6C
FC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS
11/2 in. ANSI Class 150, Weld-Neck RF, SST
11/2 in. ANSI Class 300, Weld-Neck RF, CS
11/2 in. ANSI Class 300, Weld-Neck RF, SST
11/2 in. ANSI Class 600, Weld-Neck RF, CS
11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Flow-350
Instrument Connections (Continued)
Class
Class
Class
Class
Class
Class
600, SST
600, CS
300, SST
300, CS
150, SST
150, CS
ANSI Class 300, SST
ANSI Class 300, CS
ANSI Class 150, SST
ANSI Class 150, CS
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Rosemount Inc.
MODEL PHF+25M
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
Code
K
Code
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
ProBar®
3
5
6
7
8
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
PHF+25M 040 HAMM0 C0000 GV6MA IHRC VA6CG FA6C 1 A 1 A
Flow-351
ProBar® Flowmeter
MODEL PHF+35S
Model
PHF+35S
Code
080
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
ProBar®
Flow-352
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
8 in. (200 mm)
10 in. (250 mm)
12 in. (300 mm)
14 in. (350 mm)
16 in. (400 mm)
18 in. (450 mm)
20 in. (500 mm)
24 in. (600 mm)
30 in. (750 mm)
36 in. (900 mm)
42 in. (1066 mm)
48 in. (1210 mm)
60 in. 1520 mm)
72 in. (1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
HATSN
HATS0
HATSD
Direct and Integral Mount Heads - Horizontal Line with RTD
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HVDS0
HVDSB
HVDSN
HVMS0
HVPS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HP2SS
HA2S0
HA2SS
HP2S0
Remote Mount - Horizontal Line
Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Axial, Horizontal Line, 1/2—14 NPT, SST
Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
Parallel, Horizontal Line, 1/2—14 NPT, SST
HPVS0
HPVSS
HV2S0
HV2SS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
Parallel, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2—14 NPT, SST
Axial, Vertical Line, 1/2 in. Socket Weld Port, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
CA2C0
SA2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve, Elbow, 1/2—14 NPT, CS
Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SS
CP2S0
SP2S0
CA2S0
SA2S0
CP2SS
SP2SS
Needle Valve - SST
Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve, Elbow, 1/2—14 NPT, SST
Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Rosemount Inc.
MODEL PHF+35S
Instrument Connections (Continued)
CC2C0
SC2C0
SV2C0
CB2C0
SB2C0
Gate Valve - CS
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, CS
Valve, Nipple and Tee, 1/2—14 NPT, CS
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Valve, Elbow, 1/2—14 NPT, CS
Valve, Elbow and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2S0
SB2S0
CB2SS
CC2SS
SV2SS
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2—14 NPT, SST
Valve, Elbow and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Code
GV8SC
GV8SB
GV8SA
GH8SC
GH8SB
GH8SA
Packing Gland
Graphite, 2 in. ANSI Class 600
Graphite, 2 in. ANSI Class 300
Graphite, 2 in. ANSI Class 150
Urethane, 2 in. ANSI Class 600, SST
Urethane, 2 in. ANSI Class 300, SST
Urethane, 2 in. ANSI Class 150, SST
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VB8SG
VB8CG
VA8SG
VA8CG
Gate Valve
Gate Valve, 2 in.
Gate Valve, 2 in.
Gate Valve, 2 in.
Gate Valve, 2 in.
VB8SB
VB8CB
VA8SB
VA8CB
Ball Valve
Ball Valve, 2
Ball Valve, 2
Ball Valve, 2
Ball Valve, 2
ANSI Class 300,
ANSI Class 300,
ANSI Class 150,
ANSI Class 150,
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FA8C
FA8S
FB8C
FB8S
FC8C
FC8S
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
2 in. ANSI Class
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
ProBar®
Code
SST
CS
SST
CS
Class 300, SST
Class 300, CS
Class 150, SST
Class 150, CS
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Flow-353
ProBar® Flowmeter
MODEL PHF+35S
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
9
Code
K
Code
ProBar®
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Special Manifold
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
Flow-354
PHF+35S 120 HAMS0 C0000 GV8SA IHDC VA8C 1 A 1 A
Rosemount Inc.
MODEL PHF+45S
PHF+45S
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
HADS0
HADSB
HADSN
HAMS0
HAPS0
HAXS0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, Horizontal Line, SST
Direct Mount, No Manifold, Horizontal Line, SST
Direct Mount, Quantity Two, 3-valve Manifold, Horizontal Line, SST
HATSN
HATS0
HATSD
Direct and Integral Mount Heads - Horizontal Line with RTD
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HVDSB
HVDSN
HVMS0
HVPS0
HVTS0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
Integral, 3-Valve Manifold, Vertical Line, SST
Direct Mount, No Manifold, Vertical Line, SST
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTS0
HVTSB
HVTSD
HVTSN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
CP2SS
SP2SS
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
CB2SS
CC2SS
SV2SS
Gate Valve - SST
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Outside Stem and Yoke Gate
Code
GVDSC
GVDSB
GVDSA
ProBar®
Model
Valve, Nipple, 1/2—14 NPT, SST
Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Valve, Elbow, 1/2 in. Socket Weld Port, SST
Valve, Nipple, 1/2 in. Socket Weld Port, SST
Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Packing Gland
Graphite, 3 in. ANSI Class 600
Graphite, 3 in. ANSI Class 300
Graphite, 3 in. ANSI Class 150
Flow-355
ProBar® Flowmeter
MODEL PHF+45S
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VCDSG
VCDCG
VBDSG
VBDCG
VADCG
VADSG
Gate Valve
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
VBDSB
VBDCB
VADCB
VADSB
Ball Valve
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
in. ANSI
in. ANSI
in. ANSI
in. ANSI
ProBar®
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
Code
DP Ranges
0
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
SST
CS
SST
CS
CS
SST
Class 300, SST
Class 300, CS
Class 150, CS
Class 150, SST
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
9
Code
K
Flow-356
ANSI Class 600,
ANSI Class 600,
ANSI Class 300,
ANSI Class 300,
ANSI Class 150,
ANSI Class 150,
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Special Manifold
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Rosemount Inc.
MODEL PHF+45S
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
ProBar®
Code
PHF+45S 240 HAMS0 C0000 GVDSA IHDS VADCG FADC 1 A 1 A
Flow-357
ProBar® Flowmeter
MODEL PHF+45H
Model
PHF+45H
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
ProBar®
HADH0
HADHB
HADHN
HAMH0
HAPH0
HATH0
HATHB
HATHD
HATHN
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C.
Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C.
Direct Mount, No Manifold, Horizontal Line, Hastelloy-C.
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C.
HVDH0
HVDHB
HVDHN
HVMH0
HVPH0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C.
Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C.
Direct Mount, No Manifold, Vertical Line, Hastelloy-C.
HVTH0
HVTHB
HVTHD
HVTHN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C.
HA2H0
HA2HS
HP2H0
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
Axial, Horizontal Line, 1/2 in. Socket Weld Port, Hastelloy-C.
Parallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HPVH0
HV2H0
Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2H0
Needle Valve - Hastelloy
Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C.
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Code
Packing Gland
GVDHC
GVDHB
GVDHA
Flow-358
Product Description
Graphite, 3 in. ANSI Class 600, Hastelloy-C.
Graphite, 3 in. ANSI Class 300, Hastelloy-C.
Graphite, 3 in. ANSI Class 150, Hastelloy-C.
Rosemount Inc.
MODEL PHF+45H
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VCDSG
VCDCG
VBDSG
VBDCG
VADCG
VADSG
Gate Valve
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
VBDSB
VBDCB
VADCB
VADSB
Ball Valve
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
ANSI Class 600,
ANSI Class 600,
ANSI Class 300,
ANSI Class 300,
ANSI Class 150,
ANSI Class 150,
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
Class 300, SST
Class 300, CS
Class 150, CS
Class 150, SST
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Code
1
2
4
ProBar®
in. ANSI
in. ANSI
in. ANSI
in. ANSI
SST
CS
SST
CS
CS
SST
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Flow-359
ProBar® Flowmeter
MODEL PHF+45H
Code
I5
C6
E5
K5
ID
ED
Code
ProBar®
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
Flow-360
PHF+45H 240 HAMS0 C0000 GVDHA IHDC VADCG FADC 1 A 1 A
Rosemount Inc.
MODEL PHF+45M
PHF+45M
Code
100
120
140
160
180
200
240
300
360
420
480
600
720
Code
Product Description
ProBar® + Flowmeter - Flanged Flo-Tap
Line Size
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
24 in.
30 in.
36 in.
42 in.
48 in.
60 in.
72 in.
(250 mm)
(300 mm)
(350 mm)
(400 mm)
(450 mm)
(500 mm)
(600 mm)
(750 mm)
(900 mm)
(1066 mm)
(1210 mm)
1520 mm)
(1820 mm)
Head Style
HADM0
HADMB
HADMN
HAMM0
HAPM0
Direct and Integral Mount Heads - Horizontal Line
Direct Mount, 5-Valve Manifold, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Monel
Integral, 3-Valve Manifold, Horizontal Line, Monel
Direct Mount, No Manifold, Horizontal Line, Monel
HATM0
HATMB
HATMD
HATMN
Direct and Integral Mount Heads - Horizontal Line with RTD
Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
HVDM0
HVDMB
HVDMN
HVMM0
HVPM0
Direct and Integral Mount Heads - Vertical Line
Direct Mount, 5-Valve Manifold, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
Integral, 3-Valve Manifold, Vertical Line, Monel
Direct Mount, No Manifold, Vertical Line, Monel
HVTM0
HVTMB
HVTMD
HVTMN
Direct and Integral Mount Heads - Vertical Line with RTD
Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Monel
Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0
HA2MS
HP2M0
Remote Mount - Horizontal Line
Axial, Horizontal Line, 1/2—14 NPT, Monel
Axial, Horizontal Line, 1/2 in. Socket Weld Port, Monel
Parallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0
HV2M0
HV2MS
Remote Mount - Vertical Line
Parallel, Vertical Line, 1/2—14 NPT, Monel
Axial, Vertical Line, 1/2—14 NPT, Monel
Axial, Vertical Line, 1/2 in. Socket Weld Port, Monel
Code
Instrument Connections
C0000
S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
Eliminate Instrument Connection Assembly
Eliminate Instrument Connection Assembly (Steam)
CP2C0
SP2C0
Needle Valve - CS
Needle Valve, Nipple, 1/2—14 NPT, CS
Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0
SP2S0
Needle Valve - SST
Needle Valve, Nipple, 1/2—14 NPT, SST
Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2M0
Needle Valve - Monel
Needle Valve, Nipple, 1/2—14 NPT, Monel
CC2C0
SC2C0
SV2C0
Gate Valve - CS
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0
SC2S0
SV2S0
Gate Valve - SST
Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
ProBar®
Model
Flow-361
ProBar® Flowmeter
MODEL PHF+45M
Code
GVDMC
GVDMB
GVDMA
Graphite, 3 in. ANSI Class 600, Monel
Graphite, 3 in. ANSI Class 300, Monel
Graphite, 3 in. ANSI Class 150, Monel
ProBar®
Code
Insert/Retract
IHRS
IHRC
IHDS
IHDC
Manual, Dual, SST Rods
Manual, Dual, CS Rods
Gear, Dual, SST Rods
Gear, Dual, CS Rods
Code
Isolation Valve
VCDSG
VCDCG
VBDSG
VBDCG
VADCG
VADSG
Gate Valve
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
Gate Valve, 3 in.
VBDSB
VBDCB
VADCB
VADSB
Ball Valve
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
Ball Valve, 3
ANSI Class 600,
ANSI Class 600,
ANSI Class 300,
ANSI Class 300,
ANSI Class 150,
ANSI Class 150,
in. ANSI
in. ANSI
in. ANSI
in. ANSI
Code
Flanged Mount
FADC
FADS
FBDC
FBDS
FCDC
FCDS
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
3 in. ANSI Class
Code
DP Ranges
1
2
3
Code
A
Code
1
2
Code
A
B
C
D
J
K
L
M
SST
CS
SST
CS
CS
SST
Class 300, SST
Class 300, CS
Class 150, CS
Class 150, SST
150, Weld-Neck RF, CS
150, Weld-Neck RF, SST
300, Weld-Neck RF, CS
300, Weld-Neck RF, SST
600, Weld-Neck RF, CS
600, Weld-Neck RF, SST
0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)
Output
4—20 mA with Digital Signal based on HART
Fill Fluid
Silicone
Inert Fill
Housing Material
Epoxy-Poly.-Alum. 1/2—14 NPT
Epoxy-Poly.-Alum. CM20
Epoxy-Poly.-Alum. PG13.5
Epoxy-Poly.-Alum. G1/2
316 SST 1/2—14 NPT
316 SST CM 20
316 SST PG 13.5
Epoxy-Poly.-Alum. G1/2
Code
Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR
TXR
TRA
TRP
TXA
TXP
Remote Thermowell and RTD
Remote Thermowell and RTD, Explosion-Proof
Integral RTD, Axial Head
Integral RTD, Parallel Head
Integral RTD, Explosion-Proof, Axial
Integral RTD, Explosion-Proof, Parallel
Code
Optional Manifolds
3
5
6
7
8
Code
K
Flow-362
Packing Gland
Model 305 Manifold Bolted to Transmitter
5 Valve Manifold, CS
5 Valve Manifold, SST
3 Valve Manifold, CS
3 Valve Manifold, SST
Optional Mounting Brackets
Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts
Rosemount Inc.
MODEL PHF+45M
1
2
4
Code
I5
C6
E5
K5
ID
ED
Code
M
L
Z
N
P
O
Q
R
S
T
U
V
W
X
Y
Optional Meters
LCD Meter (Rate)- Aluminum Housing
LCD Meter (Rate) - SST Housing
External LCD Rate and Total Display
Optional Hazardous Location Certificates
FM Intrinsic Safety Approval
CSA Explosion-Proof and Intrinsic Safety Approval
FM Explosion-Proof Approval
FM Explosion-Proof and Intrinsic Safety Approval
KEMA/CENELEC Intrinsic Safety Approval
KEMA/CENELEC Explosion-Proof Approval
Optional Calibration
Multipoint Flow Calibration (ID ≤ 10 in.)
Lab Flow Calibration (Average K) (<10 in.)
Special Calibration
Multipoint Flow Calibration (12 in.)
Multipoint Flow Calibration (14 in., 16 in.)
Lab Flow Calibration (Average K) (12 in.)
Lab Flow Calibration (Average K) (14 in.-16 in.)
Multipoint Flow Calibration (18 in., 20 in.)
Lab Flow Calibration (Average K) (18 in.-20 in.)
Multipoint Flow Calibration (24 in.)
Lab Flow Calibration (Average K) (24 in.)
Multipoint Flow Calibration (30 in.)
Lab Flow Calibration (Average K) (30 in.)
Multipoint Flow Calibration (36 in.)
Lab Flow Calibration (Average K) (36 in.)
Code
Optional Quality Assurance
QA1
Q21
Q23
Q29
QJ2
QM2
QT1
QT2
QT8
Dieterich Program
ANSI B31.1
ANSI B31.3
NACE MR-0175-91
Special Product Drawing
ASTM Material-Traceable (Sensor Only)
Hydrostatic Test EP-4017
Dye Penetrant ES-1012
Extended Hydro EP-4046
Typical Model Number:
ProBar®
Code
PHF+45M 240 HAMM0 C0000 GVDMA IHDC VADCG FADC 1 A 1 A
Flow-363
ProBar® Flowmeter
ProBar®
364
Flow-364
ProBar®
Rosemount Inc.
Flow-365
ProBar® Flowmeter
ProBar®
366
Flow-366
ProBar®
Rosemount Inc.
Flow-367
ProBar® Flowmeter
ProBar®
368
Flow-368
ProBar®
Rosemount Inc.
Flow-369
ProBar® Flowmeter
ProBar®
Flow-370
Rosemount Inc.
Specifications
FUNCTIONAL SPECIFICATIONS
Pressure Limits
Service(1)
0 to 1440 psig (100 barg) @ 100 °F (37.8 °C). Contact
the factory for higher pressures.
Liquid, gas, or steam.
Temperature
Pipe Sizes(2)
Storage: -50 °F to 230 °F (-46 °C to 110 °C).
Ranges(3)
Range 0:
0-0.6 in. to 0-3 in. H20
(0-0.15 to 0-7.5 kPa).
For HATSB, HVTSB, HADSB, and HVDSB
head styles and regular flanged, Flo-Tap models:
-40 °F to 750 °F (-40 °C to 398 °C).
Range 1:
0-0.5 in. to 0-25 in. H20
(0-0.12 to 0-7.22 kPa).
Remote mount (SST and Monel):
-40 °F to 850 °F (-40 °C to 454 °C).
Range 2:
0-2.5 in. to 0-250 in. H20
(0-0.62 to 0-62.2 kPa).
Remote mount (Hastelloy-C):
-40 °F to 900 °F (-40 °C to 482 °C).
Range 3:
0-10 in. to 0-1000 in. H20
(0-2.48 to 0-248 kPa).
ProBar®
With integral meter: -40 °F to 185 °F
(-40 °C to 85 °C).
1/2 in. to 72 in. (12 mm to 1800 mm).
Remote mount (Hastelloy-C) with remote
temperature sensor :
-40 °F to 1200 °F (-40 °C to 649 °C).
Indication
Optional two-line, scalable digital LCD meter.
Ambient: -40 °F to 185 °F (-40 °C to 85 °C).
With integral meter: -4 °F to 175 °F (-20 °C to 80 °C).
Output
4-20mADC, flow rate output.
Damping
Digital HART protocol superimposed on a 4–20mA
signal, available to any host that conforms to the
HART protocol.
Analog output response to a step input change is
user selectable from 0 to 36 seconds for one time
constant. This software damping is in addition to
sensor module response time.
Power Supply
External power supply required. Operates on
10.5-55VDC with no load.
Turn on Time
Performance within specification less than two
seconds after power is applied.
4–20mA Load Limitations
Maximum loop resistance is determined by the
voltage level of the external power supply, as shown
in the following flowmeter chart.
Humidity Limits
0 to 100% relative humidity.
Load (Ohms)
1935
1500
1000
Operating
Region
500
0
10.5
20
30
40
55
42.4 1
Voltage (V dc)
FIGURE 30. Load Limitations.
For CSA Approval, powersupply must not exceed 42.2V.
(1) Fluid density and Reynolds number corrections should be
compensated per DSI Annubar Handbook Equation #2.1-2.5.
(2) Consult the factory for line sizes > 72 inches. Multipoint
calibration is available for line sizes 1/2 in. to 36 in. Consult the
factory for calibration ranges in larger line sizes.
(3) Consult the factory for calibration ranges for range 3.
371
Flow-371
ProBar® Flowmeter
PERFORMANCE SPECIFICATIONS
Ambient Temperature Effect
Accuracy(1)
Per 50 °F (28 °C):
(Including linearity, hysteresis, and repeatability)
Multipoint calibration: + 0.5% of rate
(at reference conditions).
• +(0.0188% URL + 0.0938% span) spans
from 1:1 to 10:1.
• +(0.038% URL + 0.188% span) spans
from 10:1 to 100:1.
No Flow Calibration
For range 1: +(0.18% URL + 0.375% span).
+ 1.1% of volumetric flow rate.
Static Pressure Effect
+ 3% of volumetric flow rate, elbow mount.
Zero error (can be calibrated out at line pressure).
Flow Turndown
ProBar®
10:1 flow turndown—multipoint calibration.(2)
5:1 flow turndown—no calibration.
• 0.1% of URL/1,000 psi (6.9MPa) for line
pressures from 0 to 2,000 psi (0 to 13.7MPa).
• 0.2% of URL/1,000 psi (6.9MPa) for line
pressure above 2,000 psi (13.7MPa).
Stability
For range 1:0.25% of URL/1,000 psi (6.9MPa).
+ 0.25% of URL for five years.
Time Response (Electronics Only)
Mounting Position Effect
Dead time (Td): 45 milliseconds (nominal).
Zero shifts up to 2.5 inches ws (0.62kPa) which can
be calibrated out. No span effect.
Time constant (Tc): 55 milliseconds.
ProBar Flowmeter Operating Limitations
Update rate: 20 times per sec. (minimum).
Model
Vibration Effect
Less than 0.1% of URL per g when tested from
15 Hz to 2000 Hz in any axis relative to pipemounted process conditions.
Power Supply Effect
Less than 0.005% of calibrated span per volt.
RFI Effect
0.1% of span from 20 MHz to 1000MHz and for
field strength up to 30 V/m.
(1) Calibration not available for Range 0.
Water Flow Calibration (Test condition: Water at 60 °F, 50 psig,
in sch40, sch80, or sch std pipes) in totalizing test conditions.
(2) Flow turndown is based on the upper range limit of the range
selected and may vary depending on customer application, or
ProBar operating limitations
Flow-372
Minimum Reynold’s Number (Rerod)
10
2300
½ inch
4000
15/16
6500
25/26
10000
35/36
15000
45/46
25000
Where:
ρ = fluid density in lbm/ft3
d = probe width in feet
Rerod = dVρ
m
V = velocity of fluid in ft/sec
m = fluid viscosity in lbm/ft–sec
®
See the ProBar Flow Handbook (DS-4012
or 00807-0100-1192) for detailed information.
Rosemount Inc.
PHYSICAL SPECIFICATIONS
Electronics
Electrical Considerations
Stainless steel models.
½ in.— 14 NPT, PG 13.5, and CM20 conduit.
HART interface connections permanently
fixed to terminal block.
SENSOR
316/316L SST.
Hastelloy–C (Flanged models, Sensors
10, 25/26, 45/46).
• Vent valves and process flanges: 316 SST
• Process isolating diaphragms: 316L SST
• O-rings: Glass-filled TFE
Hastelloy-C Models
• Vent valves and process flanges:
Hastelloy–C models.
• Process isolating diaphragms:
Hastelloy–C models.
• O-rings: Glass-filled TFE.
Monel (Flanged models, Sensors 10, 25/26, 45/46).
Monel Models
Material
• Vent valves and process flanges: Monel.
• Process isolating diaphragms: Monel.
• O-rings: Glass-filled TFE.
ProBar®
Integral Valve and Direct Mount
Head Styles (3 and 5 Valve)
316 SST (Hastelloy–C and Monel options).
O–Rings
Teflon® (Grafoil above 500 °F [260 °C]).
Bolts
316 SST.
Hazardous Locations Certifications
Factory Mutual (FM) Approvals
E5 — Explosion Proof for Class I, Division 1, Groups
B, C, and D. Dust-Ignition Proof for Class II, Division
1, Groups E, F, and G. Dust-Ignition Proof for Class
III, Division 1. NEMA 4X. Factory-sealed.
Flange and Isolation Valves
316L SST. Flange pressure limits are per ANSI
B16.5 for 316 SST and material per SA182. Flange
face finish ANSI B16.5, 125 to 250 RMS.
Packing Gland Assembly
Packing Gland
316 SST.
Packing
Graphite AFP–127.
I5 — Intrinsically safe for use in Class I, Division 1,
Groups A, B, C, and D; Class II, Division 1, Groups E,
F, and G; Class III, Division 1 when connected in
accordance with Rosemount drawings 03031-1019
and 00275-0081 (when used with HART
Communicator Model 275), or
00268-0031 (when used with Rosemount Model 268
Communicator). Temperature Code T4. Nonincendive for Class I, Division 2, Groups A, B, C, and
D. NEMA 4X. Factory-sealed.
K5 — Combination of E5 and I5. NEMA 4X.
Factory-sealed.
Flange Mounting Hardware
(Includes nuts, bolts, and gasket) 316 SST or CS.
Temperature Options
Integral RTD
100 Ω Platinum RTD.
Remote
100 Ω Platinum RTD.
Spring loaded with ½ —14 NPT nipple and union.
FM Approved Entity Parameters FM Approved for Class I, II, and III;
for Model 8900V (1)
Division 1 and 2; Groups
VMax = 40 V dc
IMax = 165 mA
IMax = 225 mA
IMax = 160 mA (Option Code T1)
PMax = 1 W
CI = 0.01 µF (Output Code A)
LI = 10 µH
LI = 1.05 mH (Output Code A with T1)
A–G
A–G
C–G
A–G
A–G
A–G
A–G
A–G
(1) When connected in accordance with Rosemount drawings 30311019 and 00275-0081 (for use with the HART Communicator
Model 275), or 00268-0031 (for use with the Rosemount Model
268 Communicator.)
Thermowell: ½ in. × ½ —14 NPT, 316 SST with
½ in. CS weld couplet, u = 2 in. × 2 in.
Flow-373
ProBar® Flowmeter
Canadian Standards Association (CSA)
C6 — Explosion Proof for Class I, Division 1, Groups
C, and D. Dust-Ignition Proof for Class II, Division 1,
Groups E, F, and G. Dust-Ignition Proof for Class III,
Division 1. Suitable for Class I, Division 2, Groups A,
B, C, and D. CSA Enclosure-Type 4X. Factory-sealed.
Intrinsically safe for use in Class I, Division 1, Groups
A, B, C, and D when connected in accordance with
Rosemount drawings 03031-1024. Temperature Code
T3C. CSA Enclosure-Type 4X. Factory-sealed.
Output
Code M
ProBar®
Output
Code A
CSA Approved
Barriers for Model 8900V (2)
CSA Approved for Class
I, Division 1 and 2,
Groups
≤ 30 V, ≥ 330 V ≤ 28 V, ≥ 300 V
≤ 25 V, ≥ 200 V ≤ 22 V, ≥ 180 V
≤ 30 V, ≥ 150 V
Supply ≤ 28V, ≥ 300 V
Return ≤ 10 V, ≥ 47 V
Supply ≤ 30 V, ≥ 150 V
Return ≤ 10 V, ≥ 47 V
KEMA/CENELEC
ED — Explosion Proof.
EEx d IIC T5 (Tamb = 70 C); EEx d IIC T6
(Tamb = 40 C).
Enclosure Type: IP65.
ID — Intrinsically Safe.
EEx ia IIC T5 (Tamb = -45 to +40 °C); EEx ia IIC T54
(Tamb = -45 to +70 °C).
Enclosure Type: IP65.
Ui = 30V dc.
Ii = 200 mA.
Pi = 0.9 W.
Ci = 0.012 µF.
Li = 0.
A–D
C–D
A–D
C–D
(2) When connected in accordance with Rosemount drawings
00275-0082 and 3031-1024.
May be protected by one or more of the following U.S. Patent Nos.4,559,836; 4,717,159; 5,710,370; 5,773,726; 4,633,713;
and various foreign patents. Other foreign patents issued and pending.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
Coplanar, MV, and Multivariable are trademarks of Rosemount Inc.
PlantWeb is a mark of the Fisher-Rosemount group of companies.
Mass ProBar, ProBar, and Annubar are registered trademarks of Dieterich Standard Inc.
HART is a registered trademark of the HART Communications Foundation.
Monel is a registered trademark of International Nickel Co.
Teflon is a registered trademark of E. I. du Pont de Nemours & Co.
Hastelloy C and Hastelloy C-276 are registered trademarks of Cabot Corp.
Windows is a trademark of Microsoft Corp.
Dieterich Standard Inc.
Rosemount Inc.
Fisher-Rosemount Limited
Fisher-Rosemount
5601 North 71st Street
Boulder, CO 80301
Tel (303) 530-9600
Fax (303) 530-7064
8200 Market Boulevard
Chanhassen, MN 55317 USA
Tel 1-800-999-9307
Telex 4310012
Fax (612) 949-7001
Heath Place
Bognor Regis
West Sussex PO22 9SH
England
Tel 44 (1243) 863 121
Fax 44 (1243) 867 5541
Singapore Pte Ltd.
1 Pandan Crescent
Singapore 128461
Tel (65) 777-8211
Fax (65) 777-0947
Tlx RS 61117 FRSPL
PR
INT
IN
U. S. A.
ED
© 1998 Rosemount Inc.
http://www.rosemount.com
¢00809-0100-4716;¤
00813-0100-4761 Rev. DA 11/98
Flow-374