Features
• 12" Economy fluorescent luminaire replaces HID systems.
• Steel or aluminum body provides maximum thermal control, long life
and durability of components.
• Available up to 4 lamp cross section.
• Partial cutoff designed to improve vertical light levels.
• Optional end mount sensor for a variety of sensor dimensions.
• Extended body protects sensor against damage due to forklift strikes.
• Optional wrap wireguard or lens.
• Excellent lumen maintenance (95% versus ~65% for typical metal halide).
• Superior color rendering (82 CRI, versus 65-70 for metal halide).
• Made In USA. Meets ARRA & Buy American requirements.
Construction
• Partial cutoff economy housing
• Multiple reflector options available for high and low-bay mounting
and distribution applications
• Standard mounting holes and v-hangers included
• Additional mounting hardware available
• Optional wrap lens or wireguard
• Weight: 1x4-7lbs.
Certifications
• UL 1598 listed for Canada and U.S.
• Luminaires bear appropriate listing labels.
• Emergency-equipped fixtures labeled UL 924.
Electrical
•
•
•
•
•
•
•
•
Application
Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max)
Lamp frequency: > 42 kHz
Power Factor: >0.9% @ full load, 100V through 277V
Harmonic Distortion: THD < 20% @ full load
Protection: Over-Voltage, Over-Current & Short Circuit with self-recovery
Compliant to FCC 47CFR Part 18 Non-consumer Class A Sound Rating
Optional emergency battery backup
Optional step down transformer, drops 480 VAC to 277 VAC
ORDERING INFORMATION
–
MODEL
–
–
–
• Open fixtures suitable up to 50°C/122°F
• Suitable for use with most wired or wireless lighting control systems
• Suitable for dry & damp locations:
• Manufacturing
• Factory
• Warehouses
• Storage
• Commercial
• High-Bay
• Industrial
• Low-Bay
EXAMPLE HBN-1X4-4L-T8-UL1-HP-IS-ST-EA-HA-WG-C8-SH4
–
–
–
–
HBN Standard
LAMP
TYPE
BALLAST
FACTOR2
BALLAST
GRADE
T5HO T5HO
T8 T8
LP Low Power
ST Standard
HBNE Extended
SIZE
BALLAST
VOLTAGE1
Body
Sensor
Body
1x4 1x4
Nominal
LAMP QTY
3L 3 Lamp
UL x Universal
120-277
VAC
UHx 347-480
VAC
4L 4 Lamp
(.75-.78)
MP Medium
Power
(.85-.88)
MN Neutral
Power
(.97-1.04)
HP High Power
(1.15-1.20)
BALLAST
STARTING3
IS Instant Start
ISD Instant Start
Step Dimming
PS Programmed
FOOTNOTES
Start
1. Numeral indicates number of ballasts per fixture.
2. "MN" Ballast factor not for use with T8/ISD or T8/PS.
3. When using UL2, identify number of lamps powered by
each ballast before starting method. Largest number first.
Ex: 22PS = 4LT5HO.
4. Contact factory for additional cord & mounting options.
5. Numeral indicates number of lamps controlled, HBA is std.
For Wattstopper, specify -WS after sensor option.
Grade
UE Ultra Efficient
REFLECTOR
MATERIAL
EA Enhanced
Aluminum 95%
WA White Aluminum
Reflector 90-91%
–
–
–
OTHER
UP10
WG
WW
CA
10% Uplight
Zinc Wireguard
White Wireguard
Clear Acrylic
Wrap Lens
VNT Vented Body
HB 2 Point Mount
Dedicated Hanging
Brackets
HBTB Hanging Brackets +
Top Mount Box
DSTB Dottie Slots +
Top Mount Box
BODY
MATERIAL
CR 22 Gauge Cold
Rolled Steel Body
TRS Step Down
Transformer (Takes
480 to 277 VAC)
–
CORD
PLUG4
C6 6' Cord, No
Plug
C6/ 6' Cord &
L715 Plug
(L7-15P)
C6/515 6' Cord &
Plug (515P)
PQC15 15' Cord/
Quick
Connect
–
OTHER
LF Factory
Lamps
(Lamp spec
elsewhere)
EB Emergency
Battery
Backup
1PK Individually
Boxed
Fixture
OCC
SENSOR5
SHx Standard 360°
View High-Bay
Sensor
RHx Rectangular Aisle
View High-Bay
Sensor
SLx Standard 360°
View Low-Bay
Sensor
PLx Extreme Low
360° View
Low-Bay Sensor
Page 1/3 - Revised: 11/02/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
HBN
Economy 12" Partial Cutoff High-Bay
PHOTOMETRIC DATA
PHOTOMETRIC DATA: HBN-1X4-4L-T8-UL1-HP-IS-ST-EA
LUMINAIRE DATA
INDOOR CANDELA PLOT
ZONAL LUMEN SUMMARY
90
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Fixture Efficiency
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
HBN-1X4-4L-T8-UL1-HP-IS-ST-EA
1X4 12" Economy High-Bay
4L32-HP
1.00
F32
10486
156
90%
Suspended
0° = 90 90° = 90
0° = 1.32 90° = 1.16
Length: 4.01
Width: 0.98
Height: 0.24
RCR
RC
50
108
92
79
69
61
54
49
44
40
37
34
10
108
83
66
54
46
39
34
30
27
24
22
70
105
94
85
77
70
64
59
55
51
48
45
50
105
90
77
67
60
53
48
43
40
36
34
25
40
72
100
1725
60
AVG. LUMINANCE (Candela/Sq. M.)
2588
50
3450
0
10
20
30
50
30
105
86
71
60
52
45
40
35
32
29
27
%Fixt
22
36
65
90
70
70
30
108
87
72
61
52
46
40
36
32
29
27
%Lamp
2603
4226
7544
10486
80
40
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _
80
70
108
97
87
79
72
66
61
57
53
49
46
Lumens
0-30
0-40
0-60
0-90
863
COEFFICIENTS OF UTILIZATION (%)
RW
0
1
2
3
4
5
6
7
8
9
10
Zone
Average Luminance Angle
Luminaire
10
105
82
66
54
45
39
34
30
27
24
22
50
100
86
74
65
57
51
46
42
38
35
33
30
100
82
69
58
50
44
39
35
31
29
26
0
10
100
79
64
53
45
39
34
30
27
24
22
0
90
72
59
49
41
36
31
27
24
22
20
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90
3383
3392
3338
3370
3267
3133
2990
2838
2632
2380
2157
1879
1602
1340
1137
919
720
396
3383
3389
3398
319
3223
3072
2879
2699
2484
2241
2000
1751
1541
1333
1095
886
645
351
3383
3366
3387
3244
3112
2936
2761
2526
2316
2133
1978
1797
1559
1353
1208
993
701
429
3383
3418
3323
3167
3038
2867
2635
2480
2344
2204
2005
1752
1632
1527
1360
1062
787
493
3383
3450
3318
3154
3004
2795
2595
2464
2351
2227
1991
1758
1717
1630
1385
1103
814
519
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
MOUNTING OPTIONS - SUSPENDED
DOTTIE SLOT WITH V-HANGER
GRIPPLE LOOP
Included
Order Separately
HB 2-POINT HANGING BRACKETS
V-HANGER
Optional - Factory Installed
Included
DOTTIE SLOT WITH V-HANGER
GRIPPLE LOOP
Order Separately
TOP BOX FOR POWER SUPPLY
Included
Optional
4"
OR
GRIPPLE LOOP
Order Separately
4"
2"
Page 2/3 - Revised: 11/02/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
HBN
Economy 12" Partial Cutoff High-Bay
FIXTURE DIMENSIONS
END VIEW 4 LAMP
END VIEW 3 LAMP
11.726"
11.726"
2.616"
2.616"
TOP VIEW
48.000"
11.726"
*Drawings N.T.S.
EXISTING VS. PROPOSED HIGH-BAY SYSTEM
Existing
High-Bay System
MH250
MH320PS
MH400
HPS400
Proposed
High-Bay System
Lamp Quantity
& Type
1
1
1
1
Std. MH250
PS MH320
Std. MH400
Std. HPS400
Lamp Quantity
& Type
Initial
Lamp
Lumens
Lumen
Maintenance
EOL (1)
Lumens All
Lamps
Total
Fixture
Lumens
20,500
31,700
38,000
50,000
58%
62%
58%
70%
11,890
19,654
22,040
35,000
11,890
19,654
22,040
35,000
Initial
Lamp
Lumens
Lumen
Maintenance
EOL (1)
Lumens All
Lamps
Total
Fixture
Lumens
EOL (1)
Ballast Fixture
Lumens Per
Factor Efficiency
Fixture
1.00
1.00
1.00
1.00
0.75
0.75
0.75
0.75
8,198
14,741
16,530
26,250
EOL (1)
Ballast Fixture
Lumens Per
Factor Efficiency
Fixture
S/P (2)
Ratio
Net (3)
EOL
Lumens
Fixture
Input
Watts
1.49
1.49
1.49
0.62
12,171
20,119
22,561
18,080
295
368
458
464
S/P (2)
Ratio
Net (3)
EOL
Lumens
Fixture
Input
Watts
2L-T5HO
3L-T5HO
4L-T5HO
2
3
4
FP54T5HO
FP54T5HO
FP54T5HO
5,000
5,000
5,000
93%
93%
93%
4,650
4,650
4,650
9,300
13,950
18,600
1.00
1.00
1.00
0.92
0.92
0.92
8,556
12,834
17,112
1.62
1.62
1.62
12,465
18,698
24,930
117
176
234
4L-T8 Plus
4
F32T8/841
2,950
90%
2,655
10,620
1.14
0.90
10,896
1.62
15,874
147
(1) EOL = End of life (2) S/P Ratio = Scotopic to Photopic Lumens (3) Net EOL Lumens = EOL Lumens Per Fixture x (S/P).78 [.78 exponent]
*Lamp/ballast system values shown are a general reference intended to supply a quick comparison of several common
lamp/ballast systems, the associated energy consumption, and net lumen output.
*Values shown are based on normal operating temperatures (25°C T8 and 35°C T5) and at 277 volts.
*Fixture efficiency percentages are generally representative of each system type, actual values will vary.
*There are many operating variables that affect system output, in addition to rating variances from brand to brand.
*All T8 electronic ballast values shown are based on Ultra Efficient (aka 3rd Generation) T8 ballasts.
*All T5 and T8 lamp values shown are for basic grade lamps. Extended life and higher lumen lamp types are available.
*In addition to those shown, there are a wide variety of systems to choose from, each with distinct features and cost points.
*Please consult the lamp/ballast manufacturer's catalogs for the detailed information required to model your system.
Page 3/3 - Revised: 11/02/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com