HBN Economy 12" Partial Cutoff High-Bay Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • 12" Economy fluorescent luminaire replaces HID systems. • Steel or aluminum body provides maximum thermal control, long life and durability of components. • Available up to 4 lamp cross section. • Partial cutoff designed to improve vertical light levels. • Optional end mount sensor for a variety of sensor dimensions. • Extended body protects sensor against damage due to forklift strikes. • Optional wrap wireguard or lens. • Excellent lumen maintenance (95% versus ~65% for typical metal halide). • Superior color rendering (82 CRI, versus 65-70 for metal halide). • Made In USA. Meets ARRA & Buy American requirements. Construction • Partial cutoff economy housing • Multiple reflector options available for high and low-bay mounting and distribution applications • Standard mounting holes and v-hangers included • Additional mounting hardware available • Optional wrap lens or wireguard • Weight: 1x4-7lbs. Certifications • UL 1598 listed for Canada and U.S. • Luminaires bear appropriate listing labels. • Emergency-equipped fixtures labeled UL 924. Electrical • • • • • • • • Application Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Lamp frequency: > 42 kHz Power Factor: >0.9% @ full load, 100V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Current & Short Circuit with self-recovery Compliant to FCC 47CFR Part 18 Non-consumer Class A Sound Rating Optional emergency battery backup Optional step down transformer, drops 480 VAC to 277 VAC ORDERING INFORMATION – MODEL – – – • Open fixtures suitable up to 50°C/122°F • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Manufacturing • Factory • Warehouses • Storage • Commercial • High-Bay • Industrial • Low-Bay EXAMPLE HBN-1X4-4L-T8-UL1-HP-IS-ST-EA-HA-WG-C8-SH4 – – – – HBN Standard LAMP TYPE BALLAST FACTOR2 BALLAST GRADE T5HO T5HO T8 T8 LP Low Power ST Standard HBNE Extended SIZE BALLAST VOLTAGE1 Body Sensor Body 1x4 1x4 Nominal LAMP QTY 3L 3 Lamp UL x Universal 120-277 VAC UHx 347-480 VAC 4L 4 Lamp (.75-.78) MP Medium Power (.85-.88) MN Neutral Power (.97-1.04) HP High Power (1.15-1.20) BALLAST STARTING3 IS Instant Start ISD Instant Start Step Dimming PS Programmed FOOTNOTES Start 1. Numeral indicates number of ballasts per fixture. 2. "MN" Ballast factor not for use with T8/ISD or T8/PS. 3. When using UL2, identify number of lamps powered by each ballast before starting method. Largest number first. Ex: 22PS = 4LT5HO. 4. Contact factory for additional cord & mounting options. 5. Numeral indicates number of lamps controlled, HBA is std. For Wattstopper, specify -WS after sensor option. Grade UE Ultra Efficient REFLECTOR MATERIAL EA Enhanced Aluminum 95% WA White Aluminum Reflector 90-91% – – – OTHER UP10 WG WW CA 10% Uplight Zinc Wireguard White Wireguard Clear Acrylic Wrap Lens VNT Vented Body HB 2 Point Mount Dedicated Hanging Brackets HBTB Hanging Brackets + Top Mount Box DSTB Dottie Slots + Top Mount Box BODY MATERIAL CR 22 Gauge Cold Rolled Steel Body TRS Step Down Transformer (Takes 480 to 277 VAC) – CORD PLUG4 C6 6' Cord, No Plug C6/ 6' Cord & L715 Plug (L7-15P) C6/515 6' Cord & Plug (515P) PQC15 15' Cord/ Quick Connect – OTHER LF Factory Lamps (Lamp spec elsewhere) EB Emergency Battery Backup 1PK Individually Boxed Fixture OCC SENSOR5 SHx Standard 360° View High-Bay Sensor RHx Rectangular Aisle View High-Bay Sensor SLx Standard 360° View Low-Bay Sensor PLx Extreme Low 360° View Low-Bay Sensor Page 1/3 - Revised: 11/02/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HBN Economy 12" Partial Cutoff High-Bay PHOTOMETRIC DATA PHOTOMETRIC DATA: HBN-1X4-4L-T8-UL1-HP-IS-ST-EA LUMINAIRE DATA INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY 90 Ballast Ballast Factor Lamp Fixture Lumens Watts Fixture Efficiency Mounting Shielding Angle Spacing Criterion Luminous Opening in feet HBN-1X4-4L-T8-UL1-HP-IS-ST-EA 1X4 12" Economy High-Bay 4L32-HP 1.00 F32 10486 156 90% Suspended 0° = 90 90° = 90 0° = 1.32 90° = 1.16 Length: 4.01 Width: 0.98 Height: 0.24 RCR RC 50 108 92 79 69 61 54 49 44 40 37 34 10 108 83 66 54 46 39 34 30 27 24 22 70 105 94 85 77 70 64 59 55 51 48 45 50 105 90 77 67 60 53 48 43 40 36 34 25 40 72 100 1725 60 AVG. LUMINANCE (Candela/Sq. M.) 2588 50 3450 0 10 20 30 50 30 105 86 71 60 52 45 40 35 32 29 27 %Fixt 22 36 65 90 70 70 30 108 87 72 61 52 46 40 36 32 29 27 %Lamp 2603 4226 7544 10486 80 40 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ 80 70 108 97 87 79 72 66 61 57 53 49 46 Lumens 0-30 0-40 0-60 0-90 863 COEFFICIENTS OF UTILIZATION (%) RW 0 1 2 3 4 5 6 7 8 9 10 Zone Average Luminance Angle Luminaire 10 105 82 66 54 45 39 34 30 27 24 22 50 100 86 74 65 57 51 46 42 38 35 33 30 100 82 69 58 50 44 39 35 31 29 26 0 10 100 79 64 53 45 39 34 30 27 24 22 0 90 72 59 49 41 36 31 27 24 22 20 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90 3383 3392 3338 3370 3267 3133 2990 2838 2632 2380 2157 1879 1602 1340 1137 919 720 396 3383 3389 3398 319 3223 3072 2879 2699 2484 2241 2000 1751 1541 1333 1095 886 645 351 3383 3366 3387 3244 3112 2936 2761 2526 2316 2133 1978 1797 1559 1353 1208 993 701 429 3383 3418 3323 3167 3038 2867 2635 2480 2344 2204 2005 1752 1632 1527 1360 1062 787 493 3383 3450 3318 3154 3004 2795 2595 2464 2351 2227 1991 1758 1717 1630 1385 1103 814 519 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance MOUNTING OPTIONS - SUSPENDED DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Included Order Separately HB 2-POINT HANGING BRACKETS V-HANGER Optional - Factory Installed Included DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Order Separately TOP BOX FOR POWER SUPPLY Included Optional 4" OR GRIPPLE LOOP Order Separately 4" 2" Page 2/3 - Revised: 11/02/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HBN Economy 12" Partial Cutoff High-Bay FIXTURE DIMENSIONS END VIEW 4 LAMP END VIEW 3 LAMP 11.726" 11.726" 2.616" 2.616" TOP VIEW 48.000" 11.726" *Drawings N.T.S. EXISTING VS. PROPOSED HIGH-BAY SYSTEM Existing High-Bay System MH250 MH320PS MH400 HPS400 Proposed High-Bay System Lamp Quantity & Type 1 1 1 1 Std. MH250 PS MH320 Std. MH400 Std. HPS400 Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens 20,500 31,700 38,000 50,000 58% 62% 58% 70% 11,890 19,654 22,040 35,000 11,890 19,654 22,040 35,000 Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture 1.00 1.00 1.00 1.00 0.75 0.75 0.75 0.75 8,198 14,741 16,530 26,250 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 1.49 1.49 1.49 0.62 12,171 20,119 22,561 18,080 295 368 458 464 S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 2L-T5HO 3L-T5HO 4L-T5HO 2 3 4 FP54T5HO FP54T5HO FP54T5HO 5,000 5,000 5,000 93% 93% 93% 4,650 4,650 4,650 9,300 13,950 18,600 1.00 1.00 1.00 0.92 0.92 0.92 8,556 12,834 17,112 1.62 1.62 1.62 12,465 18,698 24,930 117 176 234 4L-T8 Plus 4 F32T8/841 2,950 90% 2,655 10,620 1.14 0.90 10,896 1.62 15,874 147 (1) EOL = End of life (2) S/P Ratio = Scotopic to Photopic Lumens (3) Net EOL Lumens = EOL Lumens Per Fixture x (S/P).78 [.78 exponent] *Lamp/ballast system values shown are a general reference intended to supply a quick comparison of several common lamp/ballast systems, the associated energy consumption, and net lumen output. *Values shown are based on normal operating temperatures (25°C T8 and 35°C T5) and at 277 volts. *Fixture efficiency percentages are generally representative of each system type, actual values will vary. *There are many operating variables that affect system output, in addition to rating variances from brand to brand. *All T8 electronic ballast values shown are based on Ultra Efficient (aka 3rd Generation) T8 ballasts. *All T5 and T8 lamp values shown are for basic grade lamps. Extended life and higher lumen lamp types are available. *In addition to those shown, there are a wide variety of systems to choose from, each with distinct features and cost points. *Please consult the lamp/ballast manufacturer's catalogs for the detailed information required to model your system. Page 3/3 - Revised: 11/02/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
© Copyright 2026 Paperzz