DGTkex Digital Gas Detector CH4O C3H8 CH4 C2H5OH

DGTkex Digital Gas Detector
Conforms with the ATEX directive for use
in Zone 1, 21, 2 and 22 areas
Can be fitted with catalytic or NDIR sensor
Easy to read display
Non-intrusive parameter setting and
calibration via IR link
•
•
•
•
AVACO DGTkex gas detector is designed for
detecting combustible gases and organic
vapours. It is certified for use in Zone 1, 21, 2
and 22 areas.
C4H10
CH4
C5H12
Easy to read display provides on-site information
about gas concentration. Flameproof enclosure
is suitable for demanding conditions.
The catalytic sensor has fast response,
extremely wide range of detectable gases, and
significantly better poison resistance than
traditional type pellistors.
C3H8
NDIR (Non Dispersive Infrared) sensor is more
selective, resistant to chemical attack by most
weak acids, solvents, bases and corrosive
gases (e.g. silicone, tetraethyl lead and sulphur
compounds) and it works in oxygen free
environments.
CH4O
APPLICATION
•
•
•
•
•
•
•
•
Process industry
Chemical industry
Metal industry
Natural gas stations
Engine rooms
Casting industry
Solvent stores
Painting halls
ISO 9001:2000
C2H5OH
C5H10
C6H14
ATEX
DGTkex Digital Gas Detector
CAT
NDIR
CAT
NDIR
CAT
NDIR
Pentane (C5H12)
●
●
Propane (C3H8)
●
●
Ammonia (NH3)
●
Carbon Monoxide (CO)
●
Acetone (C3H6O)
●
●
Propanol (iso-) (C3H8O)
●
Butane (C4H10)
●
●
Xylene (C8H10)
●
Toluene (C7H8)
●
●
Ethanol (C2H6O)
●
●
MEK (C4H8O)
●
Cyclohexane (C6H12)
●
●
Ethyl Acetate (C4H8O2)
●
Methane (CH4)
●
●
Cyclopentane (C5H10)
●
●
Hexane (C6H14)
●
●
Methanol (CH4O)
●
●
Hydrogen (H2)
●
Heptane (C7H16)
●
●
Octane (C8H18)
●
●
●
Other combustible gases: ask the manufacturer
TYPICAL RANGE
Freely chosen within 0 and 100% LEL
OUTPUT SIGNAL
4…20 mA, linear response
OPERATING VOLTAGE
24 V DC ±20%, 120 mA (max)
T90 RESPONSE TIME (typical)
< 20 seconds CAT, <60 seconds NDIR
OPERATING HUMIDITY
0…95% RH, non-condensing
OPERATING TEMPERATURE
Zone 1 and 2 -40…+65°C, zone 21 and 22 -20…+65°C
OPERATING PRESSURE
Normal air pressure ±10%
INGRESS PROTECTION
IP65
WEIGHT
1,66 kg
ENCLOSURE
Aluminium, Ø110mm, d127mm
CALIBRATION
The detectors are factory calibrated according to the measuring
range
The calibration and maintenance services shall be carried out by
authorized maintenance personnel
INSTALLATION
Installation instructions follow the delivery. The installation has to
be done according to the EN 60079-14 standard.
ACCESSORIES
Test gas hose
attachment kit
● naturally aspirated for
long term use
● closed model for
short term use
Stainless steel
protection cover,
ceiling assembly kit
Pipe assembly kit
VTT 06 ATEX 062 with Supplements 1-3
(Notified Body Number 0537)
II 2 G Ex d IIC T6
II 2 D Ex tD A21 T85 °C IP 65
Equipment or Protective Systems Intended for use in Potentially explosives atmospheres Directive
94/9/EC
Compliance with the Essential Health and Safety Requirements has been assured by compliance with
EN 60079-0 (2004)
EN 60079-1 (2004)
DETECTOR Oy reserves the right to make any changes, without notice, to the technical characteristics of its equipment.
DETECTOR Oy
Telekatu 8
FI-20360 TURKU
FINLAND
Tel. +358 207 756 480
Fax +358 207 756 498
www.detector.fi
[email protected]
Code No. 20715512 rev. 1.9
Hammarvägen 1
232 37 Arlöv
[email protected]
040 - 664 28 50
www.palgo.se