report number: itl83691 page: 1 of 9 issue date: 01/05/15 prepared for

®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL83691
PAGE: 1 OF 9
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
CATALOG NUMBER: S205-M009-T-02-1-00-0-30-00
LUMINAIRE: FABRICATED WHITE PAINTED METAL EXTERIOR HOUSING, EXTRUDED SEMISPECULAR METAL INTERIOR HOUSING WITH FORMED BLACK PAINTED METAL END
PLATES/MOUNTING BRACKET, EXTRUDED SEMI-SPECULAR METAL CIRCUIT BOARD
MOUNTING PLATE CONSISTING OF: ONE WHITE CIRCUIT BOARD WITH 9 LEDS,
ONE CLEAR PLASTIC OPTIC BELOW LEDS, CLEAR FLAT MICRO-PRISMATIC GLASS
LENS WITH HOLOGRAPHIC PLASTIC OVERLAY IN CAST WHITE PAINTED METAL
TRIM. LENS PRISMS IN.
LAMPS: NINE WHITE LIGHT EMITTING DIODES
6 7/8
(LEDS), TILTED 26-DEGREES FROM
VERTICAL BASE-UP POSITION.
INPUT ELECTRICAL: 120.0 VOLTS, 21.2 WATTS,
0.178 AMPS
MOUNTING: RECESSED
LED DRIVER: THOMAS RESEARCH PRODUCTS
10 9/16
12 5/8
LED20W-28-C0700-D, DRIVER HAS MULTIPLE
LEADS, ONLY LINE INPUT AND LED OUTPUT
LEADS CONNECTED FOR THIS TEST.
NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE
PROVIDED AT RATED INPUT VOLTAGE
(120VAC, 60Hz) TO THE DRIVER.
TEST PROCEDURE: IESNA LM-79-08
2 7/8
TEST DISTANCE = 20.0 FEET
0°
CANDELA DISTRIBUTION
0.0 45.0 90.0 135.0 180.0
0
340
340
340
340
340
5
516
458
338
247
217
15
651
633
342
141
108
25
557
597
355
99
74
35
417
482
350
71
46
45
343
354
313
44
21
55
285
266
240
15
1
65
222
204
150
2
0
75
158
145
66
0
0
85
99
91
10
0
0
90
76
66
0
0
0
95
53
41
0
0
0
105
8
0
0
0
0
115
0
0
0
0
0
125
0
0
0
0
0
135
0
0
0
0
0
145
0
0
0
0
0
155
0
0
0
0
0
165
0
0
0
0
0
175
0
0
0
0
0
180
0
0
0
0
0
ZONAL LUMEN SUMMARY
ZONE
LUMENS
0- 30
300
0- 40
478
0- 60
795
0- 90
1025
90-120
20
90-130
20
90-150
20
90-180
20
0-180
1044
FLUX
34
106
159
179
171
145
112
75
43
75˚
220
18
2
0
0
0
0
0
0
0
%FIXT
28.7
45.8
76.1
98.1
1.9
1.9
1.9
1.9
100.0
EFFICACY = 49.2 lm/W
CIE TYPE - DIRECT
PLANE
: 0-DEG
SPACING CRITERIA : 1.67
90˚
90-DEG 180-DEG
1.55
0.27
60˚
440
45˚
660
0˚
LEGEND:
0-deg
90-deg
180-deg
15˚
Checked
B HYRE
Approved
R BEATTIE
30˚
Lighting Engineer
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
•
WEBSITE: www.itlboulder.com
PAGE: 2 OF 9
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE AVERAGE AVERAGE
IN DEG
0-DEG 45-DEG 90-DEG
45
15366. 22396. 22461.
55
13551. 17849. 21257.
65
11625. 15129. 18023.
75
9566. 12417. 12949.
85
7307.
9530.
5741.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
32.5
35.0
37.5
40.0
42.5
45.0
47.5
50.0
52.5
55.0
57.5
60.0
62.5
65.0
67.5
70.0
72.5
75.0
77.5
80.0
82.5
85.0
87.5
90.0
92.5
95.0
97.5
100.0
102.5
105.0
107.5
110.0
112.5
115.0
117.5
120.0
122.5
125.0
127.5
130.0
132.5
135.0
137.5
140.0
142.5
145.0
147.5
150.0
152.5
155.0
157.5
0.0
340
427
516
594
641
656
651
637
618
591
557
518
479
445
417
391
373
357
343
329
315
300
285
271
254
239
222
206
190
172
158
142
127
113
99
88
76
64
53
40
27
16
8
5
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5.0
340
422
511
591
641
656
652
637
619
592
558
519
480
446
416
392
374
358
342
328
314
300
285
270
255
240
223
206
190
173
159
143
128
114
100
88
76
64
54
40
26
15
8
4
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15.0
340
420
506
581
634
653
653
639
622
597
564
525
488
452
422
395
374
358
342
327
312
298
283
268
254
238
222
205
189
173
159
144
129
114
101
88
76
64
53
39
24
14
7
4
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
CANDELA DISTRIBUTION
LATERAL ANGLE
25.0 35.0 45.0 55.0 65.0
340
340
340
340
340
413
411
396
386
372
494
476
458
435
408
570
546
520
483
443
625
602
575
531
480
648
634
610
571
513
651
646
633
603
547
639
640
635
619
572
623
628
628
622
587
603
610
614
613
592
576
589
597
599
587
543
561
575
581
575
503
528
548
559
557
466
487
516
534
535
433
452
482
504
511
405
420
446
472
485
380
393
413
437
456
361
367
383
403
425
343
345
354
369
391
327
325
327
338
357
310
307
305
310
324
294
288
284
283
292
280
272
266
259
264
266
258
249
240
240
251
244
234
223
218
237
230
219
206
198
220
214
204
189
178
205
199
189
173
160
189
183
174
158
142
172
169
158
143
125
158
155
145
129
112
144
141
132
115
97
130
127
118
103
84
114
113
105
90
72
100
98
91
77
60
88
85
78
65
48
75
73
66
53
37
64
60
53
41
26
52
48
41
30
12
37
32
25
14
2
22
16
10
5
0
11
7
4
0
0
6
4
0
0
0
3
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
•
WEBSITE: www.itlboulder.com
PAGE: 3 OF 9
75.0
340
359
379
400
420
441
468
490
509
523
531
532
526
512
495
476
453
429
401
371
340
308
277
248
220
195
172
150
129
110
94
78
64
51
40
29
20
10
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
85.0
340
346
352
358
364
370
382
392
403
411
418
423
425
424
418
410
397
382
363
342
320
292
267
242
216
191
165
138
115
94
77
59
44
32
21
12
6
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
90.0 112.5 135.0 157.5
340
340
340
340
339
315
295
278
338
285
247
225
338
261
212
186
339
241
182
154
340
221
156
129
342
208
141
115
345
196
127
103
350
185
116
95
353
174
107
86
355
166
99
80
357
157
92
73
356
149
85
65
354
141
77
58
350
133
71
51
345
125
64
45
337
117
57
38
327
110
51
32
313
101
44
25
298
92
37
19
280
84
29
13
260
74
21
8
240
66
15
5
219
59
11
2
197
51
7
0
174
43
4
0
150
35
2
0
127
26
0
0
105
18
0
0
84
8
0
0
66
3
0
0
49
1
0
0
34
0
0
0
22
0
0
0
10
0
0
0
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
160.0
162.5
165.0
167.5
170.0
172.5
175.0
177.5
180.0
0.0
0
0
0
0
0
0
0
0
0
5.0
0
0
0
0
0
0
0
0
0
15.0
0
0
0
0
0
0
0
0
0
CANDELA DISTRIBUTION
LATERAL ANGLE
25.0 35.0 45.0 55.0 65.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
•
WEBSITE: www.itlboulder.com
PAGE: 4 OF 9
75.0
0
0
0
0
0
0
0
0
0
85.0
0
0
0
0
0
0
0
0
0
90.0 112.5 135.0 157.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
•
WEBSITE: www.itlboulder.com
PAGE: 5 OF 9
CANDELA DISTRIBUTION
LATERAL ANGLE
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0
32.5
35.0
37.5
40.0
42.5
45.0
47.5
50.0
52.5
55.0
57.5
60.0
62.5
65.0
67.5
70.0
72.5
75.0
77.5
80.0
82.5
85.0
87.5
90.0
92.5
95.0
97.5
100.0
102.5
105.0
107.5
110.0
112.5
115.0
117.5
120.0
122.5
125.0
127.5
130.0
132.5
135.0
137.5
140.0
142.5
145.0
147.5
150.0
152.5
155.0
157.5
180.0
340
275
217
176
144
120
108
97
89
81
74
67
59
52
46
39
33
27
21
15
10
5
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
•
WEBSITE: www.itlboulder.com
PAGE: 6 OF 9
CANDELA DISTRIBUTION
LATERAL ANGLE
160.0
162.5
165.0
167.5
170.0
172.5
175.0
177.5
180.0
180.0
0
0
0
0
0
0
0
0
0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
5-DEGREE
ZONAL LUMEN SUMMARY
0- 5
8
5- 10
26
10- 15
44
15- 20
61
20- 25
75
25- 30
84
30- 35
89
35- 40
90
40- 45
88
45- 50
83
50- 55
76
55- 60
69
60- 65
61
65- 70
51
70- 75
42
75- 80
33
80- 85
25
85- 90
18
90- 95
12
95-100
6
100-105
2
105-110
0
110-115
0
115-120
0
120-125
0
125-130
0
130-135
0
135-140
0
140-145
0
145-150
0
150-155
0
155-160
0
160-165
0
165-170
0
170-175
0
175-180
0
WEBSITE: www.itlboulder.com
PAGE: 7 OF 9
10-DEGREE
ZONAL LUMEN SUMMARY
0- 10
34
0- 20
140
0- 30
300
0- 40
478
0- 50
650
0- 60
795
0- 70
907
0- 80
982
0- 90
1025
0-100
1042
0-110
1044
0-120
1044
0-130
1044
0-140
1044
0-150
1044
0-160
1044
0-170
1044
0-180
1044
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
•
WEBSITE: www.itlboulder.com
REPORT NUMBER: ITL83691
PAGE: 8 OF 9
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
1
2
3
4
5
6
7
8
9
10
119119119119
108103 98 94
98 89 82 77
89 79 71 64
82 70 61 54
76 63 54 47
70 57 48 41
65 52 43 37
61 47 39 33
57 43 35 30
53 40 32 27
116116116116
105100 96 92
95 87 81 76
87 77 69 63
80 69 60 54
73 62 53 47
68 56 47 41
63 51 42 37
59 46 38 33
55 43 35 30
52 39 32 27
110110110
95 92 89
84 78 73
74 67 62
66 59 53
59 52 46
54 46 41
49 42 36
45 38 32
41 34 29
38 31 27
105105105
91 88 86
80 75 71
71 65 61
63 57 52
57 51 45
52 45 40
47 41 36
43 37 32
40 34 29
37 31 26
100100100
87 85 83
77 73 70
68 63 59
61 56 51
55 49 45
50 44 40
46 40 35
42 36 32
39 33 29
36 30 26
0
0
98
81
67
57
49
43
38
33
30
27
24
ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE
BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES
ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS TEST SAMPLE.
NOTE:
THE ZONAL CAVITY CALCULATION TECHNIQUE IS ACCURATE WHEN
LUMINAIRES WITH SYMMETRIC CANDELA DISTRIBUTIONS ARE EMPLOYED
AND WHEN THE LUMINAIRES ARE LOCATED SYMMETRICALLY THROUGHOUT
THE ROOM. THIS UNIT HAS SPECIAL CHARACTERISTICS AND THEREFORE
THESE COEFFICIENTS SHOULD BE USED WITH CAUTION.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
®
NVLAP LAB CODE: 200925-0
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303) 442-1255
•
FAX: (970) 535-3114
•
INDEPENDENT TESTING LABORATORIES, INC.
4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA
E-MAIL: [email protected]
REPORT NUMBER: ITL83691
ISSUE DATE: 01/05/15
PREPARED FOR: FRAQTIR BY THE LIGHTING QUOTIENT
•
WEBSITE: www.itlboulder.com
PAGE: 9 OF 9
ADDRESS: 114 BOSTON POST ROAD
WEST HAVEN, CT 06516
THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY
THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT
BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.