LM-79-08 Test Report

Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
LM-79-08 Test Report
For
Venture Lighting International,Inc
(Brand Name: N/A)
7905 Cochran Road,Ste 300Glenwillow,Ohino 44139,USA
LED Lamp
Model name(s): OR100-40E39
Model differences: N/A
Test & Report By:
Review By:
Johnson Sun
Engineer: Johnson Sun
Manager: Tommy Liang
Date:Feb.26, 2016
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or
any agency of the Federal Government.
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
1 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
U.S. Department of Energy
Lighting FactsTM Uniform LM-79 Reporting Template
Laboratory Information:
Name of Test Laboratory
Standard-Tech Co., Ltd.
Date of Test Report
Feb.26, 2016
Test Report No.
GZE160226-A
Laboratory Contact Name
Tommy Liang
Product Information:
Organization Name
Venture Lighting International,Inc
Brand Name
N/A
Model Number
OR100-40E39
SKU (if available)
N/A
Type of Luminaire
(for integral lamps, list base type and lamp type)
LED Lamp
Luminaire Aperture (for downlights)
--
in.
Luminaire Length
--
mm
Luminaires Width
--
mm
Number of Units (modular products)
N/A
s
Integrating Sphere
Goniophotometer
Output
Output
Input Wattage
--
101.5
W
Input Current
--
0.8508
A
Input Voltage (ac)
--
120.0
V
Power Factor
--
0.9941
Off-State Power
--
0
W
Total Luminous (lm)
--
11123
lm
Luminous Efficacy (lm/W)
--
109.61
lm/w
Correlated color temperature / CCT
4109
--
K
Color rendering index / CRI
83.4
--
9
--
0.0010
--
Center beam candlepower (if applicable)
--
382
cd
Beam angle (if applicable)
--
265.9
°
Zonal lumens in the 0°-60° zone
--
28.6
%
Zonal lumens in the 60°-90° zone
--
37.8
%
Zonal lumens in the 90°-120° zone
--
23.5
%
Zonal lumens in the 120°-180° zone
--
10.1
%
Electrical Measurements:
Photometric Characteristics
R9 Value
Duv
Luminous Intensity Distribution
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
2 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
Test Specifications:
Date of Receipt
: Nov.27,2015
Date of Test
: Feb.24,2016
Test item
: Total Luminous Flux, Luminous Distribution Intensity, Luminous
Efficacy, Correlated Color Temperature, Color Rendering Index,
Chromaticity Coordinate, Electrical parameters
Reference Standard
IES LM-79-2008 Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI C78.377-2008 Specifications for the Chromaticity of Solid State
Lighting Products
CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering
Properties of Light Sources
CIE 15-2004 Technical Report Colorimetry
IESNA LM-16-93 Practical Guide to Colorimetry of Light Source
IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)
Sources and Systems
Reference Work
QD25
Instruction
Test Methods
1. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It
was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature
and color rendering index were calculated from the spectral radiant flux measurements taken at least 5
nm intervals over the range of 380 to 780 nm.
2. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It
was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature
and color rendering index were calculated from the spectral radiant flux measurements taken at least 5
nm intervals over the range of 380 to 780 nm.
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
3 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
1. Product Information:
Brand Name
N/A
Model Number
OR100-40E39
Luminaire Type
LED Lamp
Rated Voltage / Frequency
100 ~ 277Vac, 50/60Hz
Nominal Power
100W
Rated Initial Lamp Lumen
N/A
Declared CCT
4000K
LED Manufacturer
Guangzhou Hongli Opto-Electronic Co., Ltd.
LED Model
HL-A-2835HW-S1-08-HR3
Sample Receipt Date
Nov.27,2015
Sample Number
GZE160226-A1
Photo
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
4 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
2.1 Electrical, Photometric and Chromaticity Measurements
IES LM-79 2008
(Refer to Work Instruction QD25)
Test date
2016-02-24
Test Ambient:
25.1º C
Test Orientation
As intended
Stabilization Time (min)
90
Model Number
OR100-40E39
Electrical Measurement:
Sample No.
Voltage (Vac)
Frequency (Hz )
Current (A)
Power (W)
Power Factor
THD %
GZE160226
120.0
60
0.8508
101.5
0.9941
9.74
-A1
277.1
60
0.3920
99.80
0.9188
13.55
Sphere-Spectroradiometer Method:
Parameter
Result
Test Voltage (V)
120.0
R1
82
R9
9
Frequency (Hz)
60
R2
91
R10
78
83.4
R3
96
R11
79
9
R4
81
R12
61
4109
R5
82
R13
84
Color Rendering Index (CRI)
R9
CCT (K)
Special Color Rendering Indices
Chromaticity (x, y)
x=0.3764
y=0.3763
R6
87
R14
98
Chromaticity (u’, v’)
u'=0.2226
v'=0.5008
R7
85
R15
76
R8
64
--
--
Duv
0.0010
Goniophotometer Method:
Parameter
Result
Test Voltage (V)
120.0
Frequency (Hz)
60
Total Luminous (lm)
11123
Luminous Efficacy (lm/W)
109.61
Beam Angle°
265.9
Center Beam Candle Power (cd)
382
Goniophotometer Method:
Parameter
Result
Test Voltage (V)
277.0
Frequency (Hz)
60
Total Luminous (lm)
11088
Luminous Efficacy (lm/W)
111.11
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
5 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
Spectral Power Distribution & Chromaticity Diagram
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
6 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
Zonal Lumen Tabulation:
Zonal Lumen Summary
Zone
Lumens % Luminaire
0-30
538.1
4.8%
0-40
1,146.6
10.3%
0-60
3,176.4
28.6%
60-90
4,207.7
37.8%
70-100
3,911.6
35.2%
90-120
2,617.1
23.5%
0-90
7,384.1
66.4%
90-180
3,740.1
33.6%
0-180
11,124.2
100%
Lumens Per Zone
Zone Lumens % Total
Zone
Lumens % Total
0-10
38.9
0.3%
90-100
1,031.0
9.3%
10-20
151.9
1.4%
100-110
836.1
7.5%
20-30
347.3
3.1%
110-120
750.1
6.7%
30-40
608.5
5.5%
120-130
558.4
5%
40-50
887.3
8.0%
130-140
325.5
2.9%
50-60 1,142.6
10.3%
140-150
159.3
1.4%
60-70 1,327.1
11.9%
150-160
68.1
0.6%
70-80 1,430.0
12.9%
160-170
11.0
0.1%
80-90 1,450.7
13.0%
170-180
0.8
0%
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
7 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
Photometric Data
Illuminance Plots
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
8 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
ISOCANDELA DIAGRAM
ISOLUX DIAGRAM
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
9 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
Candela Table - Type C
0
22.5
45
67.5
90
112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0
382
382
382
382
382
382
382
382
382
382
382
382
382
382
382
382
382
1
382
382
382
381
382
382
382
382
382
382
382
382
382
380
381
381
382
2
384
382
381
381
382
382
380
383
384
383
382
383
383
382
380
382
384
3
385
384
383
384
384
382
384
385
386
385
385
385
385
384
385
384
385
4
387
387
387
387
386
386
387
386
388
389
388
388
389
388
388
387
387
5
391
390
390
390
391
391
390
390
391
394
393
394
394
393
392
392
391
6
397
396
396
397
397
397
395
397
399
399
398
401
401
398
397
397
397
7
404
403
403
405
403
403
403
405
407
408
408
408
409
407
405
404
404
8
412
412
412
413
412
412
413
413
417
418
418
417
419
416
414
413
412
9
423
423
422
424
425
423
423
424
426
429
429
430
431
427
422
422
423
10
436
436
435
436
436
435
433
438
439
442
440
444
445
440
435
435
436
11
449
449
449
451
449
450
450
452
455
456
457
460
458
455
452
447
449
12
463
463
466
466
466
462
465
467
470
472
473
476
474
470
467
462
463
13
479
479
482
481
483
481
483
487
486
488
491
494
490
486
483
479
479
14
495
498
500
498
501
500
501
506
503
505
510
512
509
505
503
496
495
15
512
517
521
519
519
519
522
524
523
525
530
532
526
523
521
514
512
16
530
534
542
540
538
537
543
544
540
543
550
552
544
540
541
533
530
17
551
554
562
560
559
557
564
566
559
563
571
574
567
560
564
554
551
18
572
575
584
582
581
579
587
588
582
586
592
596
588
582
585
577
572
19
594
597
606
605
604
603
609
611
605
610
613
618
607
603
607
599
594
20
615
619
626
627
626
627
631
635
626
632
635
642
629
625
628
621
615
21
637
639
646
650
650
651
654
660
650
654
658
666
650
646
650
645
637
22
662
662
668
675
675
675
676
682
675
679
681
691
675
668
672
669
662
23
688
684
689
698
701
699
697
704
701
704
702
713
698
690
695
691
688
24
713
708
710
720
726
722
719
726
728
725
722
733
722
711
716
713
713
25
738
731
730
742
752
743
739
747
753
747
741
756
748
733
737
735
738
26
764
754
752
765
779
764
760
768
779
769
761
778
774
755
759
759
764
27
794
776
773
791
806
787
782
789
807
793
782
800
800
778
779
782
794
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
10 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
28
823
798
795
814
835
811
804
813
838
818
803
823
828
801
799
807
823
29
851
820
816
839
865
836
823
836
866
842
824
847
855
824
818
830
851
30
879
842
837
861
895
860
844
856
897
866
845
867
879
844
838
852
879
31
906
864
858
882
925
882
864
876
925
887
866
887
902
865
859
873
906
32
931
885
877
903
952
902
882
894
951
906
884
908
925
884
879
894
931
33
955
905
897
925
980
922
902
915
978
927
904
928
948
904
898
916
955
34
980
927
915
948 1006
942
921
935 1005
947
923
948
970
923
916
936
980
35 1002
950
932
969 1032
961
940
953 1029
967
941
967
991
941
935
956 1002
36 1023
966
948
990 1057
980
959
971 1054
985
960
988 1011
958
953
976 1023
37 1043
987
967 1011 1081
999
978
990 1078 1003
978 1010 1029
975
972
995 1043
997 1007 1100 1022
996 1031 1049
992
988 1013 1063
38 1063 1005
984 1032 1102 1018
39 1081 1023 1002 1052 1122 1035 1013 1026 1123 1040 1015 1050 1065 1009 1005 1033 1081
40 1099 1042 1019 1073 1140 1052 1030 1045 1143 1059 1033 1069 1082 1027 1022 1052 1099
41 1115 1061 1037 1090 1157 1069 1049 1064 1161 1075 1052 1088 1098 1044 1038 1070 1115
42 1132 1078 1054 1110 1173 1086 1067 1081 1179 1090 1069 1107 1114 1061 1054 1087 1132
43 1147 1096 1071 1129 1189 1101 1087 1098 1196 1105 1089 1124 1129 1077 1071 1103 1147
44 1161 1113 1088 1150 1203 1117 1105 1115 1210 1118 1108 1141 1143 1094 1089 1123 1161
45 1175 1129 1104 1166 1218 1132 1124 1133 1225 1131 1127 1158 1158 1110 1105 1139 1175
46 1188 1146 1120 1183 1231 1147 1142 1148 1242 1144 1142 1175 1172 1126 1121 1156 1188
47 1202 1161 1136 1201 1245 1161 1159 1163 1255 1158 1158 1190 1184 1140 1134 1172 1202
48 1214 1175 1152 1218 1258 1175 1175 1178 1269 1171 1171 1206 1198 1154 1146 1187 1214
49 1226 1190 1166 1232 1270 1189 1192 1192 1281 1184 1184 1222 1211 1167 1155 1203 1226
50 1239 1203 1178 1247 1282 1203 1206 1204 1294 1197 1194 1237 1223 1181 1165 1216 1239
51 1251 1216 1190 1262 1293 1217 1218 1218 1304 1209 1205 1250 1235 1194 1176 1231 1251
52 1262 1228 1202 1274 1306 1229 1229 1229 1313 1220 1214 1264 1246 1206 1188 1244 1262
53 1273 1241 1214 1287 1315 1241 1240 1240 1322 1232 1222 1277 1256 1219 1198 1256 1273
54 1283 1254 1224 1300 1326 1253 1251 1253 1331 1245 1233 1288 1266 1231 1208 1269 1283
55 1292 1265 1237 1314 1337 1268 1263 1267 1340 1256 1243 1301 1276 1246 1220 1282 1292
56 1301 1278 1246 1324 1344 1279 1271 1280 1349 1266 1249 1314 1288 1261 1232 1297 1301
57 1312 1287 1256 1334 1351 1289 1278 1291 1359 1276 1259 1324 1297 1273 1245 1308 1312
58 1321 1295 1263 1345 1360 1300 1280 1299 1364 1284 1268 1335 1304 1283 1253 1319 1321
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
11 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
59 1327 1304 1269 1354 1366 1307 1281 1303 1371 1294 1275 1344 1310 1291 1259 1328 1327
60 1333 1313 1276 1362 1371 1316 1282 1309 1377 1302 1279 1350 1314 1299 1265 1335 1333
61 1339 1318 1278 1368 1375 1321 1281 1316 1381 1305 1280 1356 1318 1305 1271 1343 1339
62 1341 1322 1279 1375 1378 1325 1283 1324 1382 1310 1280 1362 1321 1309 1274 1349 1341
63 1344 1326 1280 1379 1382 1330 1287 1329 1382 1314 1285 1368 1324 1317 1278 1354 1344
64 1346 1332 1282 1384 1386 1333 1289 1333 1383 1319 1290 1373 1327 1323 1283 1357 1346
65 1348 1338 1286 1388 1388 1339 1290 1338 1387 1325 1292 1377 1329 1331 1287 1362 1348
66 1351 1344 1288 1392 1389 1344 1293 1342 1389 1328 1292 1382 1333 1337 1291 1365 1351
67 1353 1349 1289 1396 1391 1349 1295 1345 1391 1329 1295 1387 1334 1341 1294 1370 1353
68 1357 1350 1290 1400 1396 1354 1296 1348 1393 1333 1298 1389 1336 1345 1298 1371 1357
69 1359 1352 1289 1402 1398 1357 1296 1351 1396 1336 1299 1392 1339 1350 1303 1373 1359
70 1362 1354 1289 1405 1397 1359 1296 1352 1395 1336 1300 1394 1339 1355 1308 1375 1362
71 1362 1356 1290 1407 1396 1361 1296 1355 1394 1337 1303 1398 1339 1359 1309 1376 1362
72 1360 1359 1292 1409 1396 1365 1295 1355 1394 1339 1304 1400 1337 1362 1310 1378 1360
73 1361 1361 1291 1413 1396 1365 1297 1357 1394 1339 1303 1401 1335 1362 1312 1379 1361
74 1360 1360 1291 1412 1398 1365 1296 1361 1395 1340 1303 1400 1336 1365 1316 1382 1360
75 1359 1359 1291 1413 1396 1365 1296 1360 1393 1338 1301 1400 1334 1366 1316 1378 1359
76 1355 1356 1287 1410 1393 1364 1294 1358 1391 1336 1300 1401 1331 1363 1314 1377 1355
77 1352 1355 1284 1410 1392 1364 1291 1357 1387 1334 1298 1399 1329 1363 1312 1375 1352
78 1351 1353 1282 1407 1389 1361 1288 1357 1385 1333 1298 1398 1328 1363 1312 1373 1351
79 1349 1352 1281 1406 1386 1360 1284 1355 1381 1329 1296 1396 1325 1362 1311 1373 1349
80 1349 1350 1278 1405 1383 1358 1281 1354 1380 1327 1293 1395 1325 1361 1311 1372 1349
81 1347 1349 1275 1402 1380 1355 1277 1351 1379 1325 1290 1392 1319 1359 1307 1371 1347
82 1345 1346 1271 1399 1379 1352 1273 1348 1376 1324 1286 1390 1317 1357 1304 1367 1345
83 1343 1343 1269 1395 1376 1350 1269 1347 1374 1323 1284 1387 1315 1355 1303 1366 1343
84 1341 1342 1266 1394 1374 1346 1265 1347 1372 1322 1282 1386 1315 1353 1302 1365 1341
85 1342 1342 1265 1391 1372 1343 1263 1346 1373 1322 1281 1384 1316 1352 1302 1366 1342
86 1341 1342 1263 1389 1371 1341 1262 1346 1373 1321 1279 1382 1315 1351 1301 1365 1341
87 1337 1338 1259 1386 1370 1339 1260 1344 1369 1318 1277 1380 1312 1348 1296 1360 1337
88 1329 1330 1254 1382 1370 1336 1255 1336 1360 1307 1269 1376 1308 1344 1288 1352 1329
89 1316 1315 1241 1374 1367 1325 1238 1307 1344 1286 1247 1361 1299 1328 1272 1337 1316
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
12 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
90 1299 1290 1215 1337 1323 1276 1189 1216 1273 1221 1195 1307 1254 1283 1237 1291 1299
91 1208 1200 1162 1284 1272 1225 1115 1093 1160 1100 1120 1246 1205 1228 1163 1174 1208
92 1091 1076 1087 1229 1221 1175 1047
965 1044
975 1046 1180 1151 1164 1092 1048 1091
93
973
951 1019 1171 1169 1118
977
849
926
859
976 1123 1095 1105 1016
916
973
94
878
852
945 1113 1117 1058
906
824
888
822
900 1067 1042 1050
942
852
878
95
853
832
875 1052 1066
999
832
803
859
800
828 1008
990
991
866
834
853
96
833
816
803
989 1013
941
776
787
848
794
771
949
939
932
808
819
833
97
822
804
752
932
959
889
730
777
838
780
730
890
903
873
760
808
822
98
820
791
712
879
945
836
696
764
828
765
702
836
900
816
728
798
820
99
810
777
689
824
938
786
666
751
808
756
684
786
897
764
706
786
810
100
796
769
670
773
933
741
642
809
796
784
660
742
893
718
688
795
796
101
785
844
648
729
925
699
615
918
840
891
642
699
887
680
666
895
785
102
876
955
631
691
920
663
588 1025
947
999
631
662
882
641
648 1006
876
103
978 1068
614
657
913
629
562 1091 1052 1080
605
628
876
606
630 1117
978
104 1082 1105
591
626
912
598
525 1088 1138 1068
578
599
869
580
600 1122 1082
105 1114 1088
568
594
910
563
510 1077 1124 1058
566
570
865
555
577 1105 1114
106 1096 1074
555
566
908
530
499 1061 1112 1045
575
546
864
532
573 1091 1096
107 1084 1061
569
550
898
507
516 1039 1099 1020
604
523
861
509
588 1077 1084
108 1072 1040
608
524
889
475
561 1012 1083
996
657
500
851
486
634 1056 1072
109 1057 1016
653
506
881
456
607
996 1059
978
694
476
842
464
676 1032 1057
110 1036
997
699
489
874
437
645
977 1039
960
732
462
833
445
719 1014 1036
111 1016
979
733
475
865
425
690
954 1024
938
761
463
820
438
746
992 1016
112
998
961
759
474
849
432
722
930 1007
911
769
476
803
453
765
971
998
113
980
934
774
496
841
448
733
907
983
893
760
498
806
473
773
948
980
114
962
912
758
517
861
472
743
890
958
873
741
519
840
496
750
921
962
115
939
895
744
535
898
492
717
860
942
845
719
534
877
516
731
904
939
116
918
872
721
555
934
509
704
835
925
818
699
550
913
533
705
882
918
117
904
845
704
574
975
525
682
818
896
799
675
566
949
544
679
853
904
118
884
825
683
587 1016
532
661
794
872
771
659
573
987
554
656
833
884
119
855
807
669
588 1052
537
643
766
857
742
635
565 1023
553
623
816
855
120
838
778
647
579 1084
530
622
751
828
717
617
559 1048
542
599
788
838
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
13 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
121
821
759
630
571 1106
524
605
725
795
691
598
551 1057
528
578
765
821
122
793
738
615
563 1104
516
586
701
772
664
581
543 1044
518
560
746
793
123
771
715
596
555 1091
508
574
681
742
632
560
536 1031
509
542
719
771
124
744
692
583
550 1076
500
556
656
684
602
547
531 1016
501
528
697
744
125
601
669
567
543 1060
495
540
634
537
576
531
529 1000
494
509
673
601
126
458
648
551
538 1043
493
525
610
406
546
510
523
983
491
493
648
458
127
387
625
530
531 1025
488
506
588
331
525
488
518
965
492
481
625
387
128
317
603
507
525 1008
484
481
565
258
503
467
517
947
489
469
600
317
129
281
578
482
521
988
482
459
544
233
476
443
513
927
484
461
575
281
130
344
545
457
517
969
481
436
518
283
446
422
510
907
481
441
542
344
131
374
510
432
507
950
479
409
488
273
413
395
504
887
477
418
504
374
132
366
467
405
501
929
475
383
455
257
372
371
498
866
472
397
462
366
133
358
419
382
495
908
472
356
415
246
337
348
494
844
465
371
412
358
134
346
376
356
485
888
469
329
372
234
300
328
490
823
459
344
369
346
135
335
332
337
485
867
466
311
331
219
268
311
485
803
455
309
331
335
136
322
291
314
482
847
464
293
290
203
236
288
481
784
451
280
292
322
137
307
253
297
479
828
461
276
249
192
193
273
475
764
447
259
256
307
138
285
217
279
475
808
460
264
218
190
161
255
469
744
444
233
215
285
139
264
186
262
470
786
457
248
171
200
116
239
462
723
440
215
179
264
140
253
163
247
462
764
451
232
133
203
71
225
451
703
436
190
158
253
141
238
120
231
452
741
444
217
106
141
32
208
440
679
428
163
115
238
142
220
76
215
441
715
438
204
84
77
16
195
427
654
419
146
73
220
143
153
44
202
430
686
432
192
85
27
47
183
412
629
409
134
47
153
144
80
62
189
420
656
425
184
84
17
76
169
399
604
398
129
60
80
145
42
93
176
411
629
416
176
73
51
117
157
383
581
389
126
90
42
146
83
122
167
401
602
407
171
57
94
141
149
368
556
380
123
114
83
147
117
123
159
388
576
397
170
44
124
127
141
352
531
370
122
114
117
148
112
114
151
374
547
388
170
38
114
114
131
335
505
359
115
101
112
149
97
111
145
358
516
380
170
35
99
98
120
316
477
345
110
95
97
150
82
106
140
343
484
373
171
31
86
89
106
299
449
329
115
94
82
151
67
96
135
329
453
364
172
27
76
76
92
280
421
315
118
88
67
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
14 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
152
54
83
133
317
424
351
175
22
59
63
72
263
397
301
121
75
54
153
43
71
126
303
397
338
175
20
50
52
51
244
373
287
118
60
43
154
34
59
115
288
370
325
175
22
40
42
26
223
345
271
108
50
34
155
26
48
102
271
341
311
171
21
29
32
12
203
320
256
93
43
26
156
20
42
80
256
314
294
169
10
22
25
6
184
297
240
75
37
20
157
15
38
59
240
290
276
161
5
20
21
6
160
273
226
53
33
15
158
13
36
40
222
264
258
148
6
16
18
11
126
249
209
31
31
13
159
12
34
24
204
239
236
133
15
7
10
17
88
226
188
15
30
12
160
11
31
17
179
216
213
115
28
4
5
22
48
205
161
9
28
11
161
10
29
22
145
191
188
84
46
5
4
25
20
178
125
12
26
10
162
10
28
32
96
158
156
54
50
9
4
27
17
144
78
16
24
10
163
10
26
40
52
116
111
27
54
14
6
26
24
95
37
26
23
10
164
10
24
43
19
64
62
13
52
18
9
22
42
49
11
29
21
10
165
10
22
36
6
28
28
17
50
17
9
22
56
15
4
28
19
10
166
9
20
28
4
11
11
28
45
16
8
20
51
8
5
22
17
9
167
9
17
18
16
15
15
46
40
15
8
18
45
14
16
15
15
9
168
8
15
8
26
31
32
54
35
15
8
14
34
34
23
7
12
8
169
8
12
3
23
46
45
47
30
13
7
10
28
41
21
3
9
8
170
7
9
3
19
41
41
38
25
11
6
10
17
29
17
3
6
7
171
5
4
3
15
32
32
30
20
10
6
8
13
26
14
3
3
5
172
3
3
3
12
23
23
21
16
8
5
6
11
20
10
3
3
3
173
3
3
5
9
16
16
16
12
7
4
5
8
14
8
4
3
3
174
2
3
5
7
11
11
11
9
5
3
3
7
9
6
4
3
2
175
2
3
5
5
7
7
8
6
4
3
3
5
7
5
4
3
2
176
3
3
4
4
5
5
6
5
3
2
3
4
5
4
3
3
3
177
3
3
3
3
3
3
4
3
2
2
2
3
3
2
3
2
3
178
2
2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
179
2
2
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
180
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
15 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
16 / 17
Report No.: GZE160226-A
NVLAP LAB CODE 201011-0
3. Test Equipment
Equipment ID
Equipment Name
Last Calibration Date
Next Calibration Date
ST-R-336
2 meter Integrating Sphere
2015-07-01
2016-06-30
ST-R-331
Spectral analysis system HAAS-2000
2015-07-01
2016-06-30
D204
Standard Lamp
2015-07-01
2016-06-30
PF2010
Power Meter for Integrating Sphere
2015-07-01
2016-06-30
EE-09
Goniophotometer system
2015-07-01
2016-06-30
D908S
Standard Lamp
2015-07-01
2016-06-30
PF210
Power Meter for Goniophotometer
2015-07-01
2016-06-30
ST-R-181A
Temperature Tester
2015-07-01
2016-06-30
Uncertainty
Photometric Measurement (Sphere):1.74%
Chromaticity Measurement(Sphere):14.3K
Photometric Measurement(Goniophotometer):1.62%
****** END OF DATASHEET PACKAGE ******
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320
Fax: 8620-32290422
http://www.standard-tech.com
17 / 17