Modular Alarm Reporting ProTalk B1285-P1 PLC Module R Key Features + Provides connectivity with Modicon and Allen Bradley PLCs + + + + + RS232, RS485 and Ethernet ports Real-time monitoring E-mail capability PLC communication failure alarms Failsafe operation without the Main module ProTalk Alarm Reporting Units BARNETT ENGINEERING LTD. ProTalk B1285-P1 PLC Module R Specifications Serial Ports RS232 (DTE) DB9 or RS485 selectable (note 1) Network Port Ethernet Current Consumption 150 mA @ +12V, 100 mA @ 24V with all indicators on Physical 8.9” wide x 2.42” high x 4.32” deep, steel, powder coated matte black, mounting ears for panel installation Front Panel LED indicators and connector markings System Connectors DB15 male (bottom of case), DB15 female (top of case) Environment -40oC to +60oC Note 1 - Plug-in compression screw terminal strip. Programmable Features Digital Alarms Alarm on either a 0 or 1. Analog Alarms Settings for binary maximum and minimum with the corresponding decimal maximum and minimum. Setting range for the decimal values is between -9999 and +9999, values outside of this range are adjusted using the Units setting. High and low setpoints with hysteresis (1 to 25%). Comm Watch Alarms One Comm Watch per unit ID. Poll Fail count in master mode determines if there is a failure; in slave mode it is the Poll Fail Timer, up to 65530 scaled in sec or min. *for all alarms above Latched or momentary operation. 1 to 7 digit DTMF TX code can be used for signaling applications. Activated by assigning it to one of the 8 groups or disabled. Totalizers An analog register can be interpreted as a totalizer (does not alarm). Units Applies units to analog alarms and totalizers using a three part selection: prefix: none, thousand, million, milli, centi, kilo, mega, giga measurement: none, cubic meters, cubic yards, cubic feet, PSI, pounds, meters, RPM, gallon, barrels, percent, parts per million rate: none, per day, per hour, per minute, per second Coil Output Used for setting/clearing a bit location in the PLC. 1 to 7 digit DTMF On and Off codes control the bit setting. Major/Minor Alarms Ethernet link failure and e-mail undeliverable can be set as a major or minor alarm. Protocols Modbus master or slave, RTU or TCP, Allen Bradley DF1, PLC5 or SLC500 master. Port Settings Baud rate: 300, 1200, 2400, 4800, 9600, 19,200, 38,400, 57,600 or, 115,200. Parity: even, odd, none. Connector: RS232 or RS485. Communications Timers (Master mode only) Poll Interval: up to 65530 msec in 10 msec steps. Poll Timeout: up to 65530 msec in 10 msec steps. Poll Retries: 1 to 5. Ethernet Port IP address, subnet mask, default gateway, e-mail server and enable. Block Addresses Settings for each Block: the PLC node, the first register address, the type of register: bit, analog, bit array, comm watch or unused. BARNETT ENGINEERING LTD. Telephone: (800) 268-2646 www.barnett-engg.com
© Copyright 2025 Paperzz