OPGW-Bolted-Dead-End

Bolted Dead End for OPGW
The AFL Dead End is a full tension termination for Optical Ground Wire cable. Breakaway head bolts are used to apply a precise gripping force to hold the cable without
affecting optical fiber performance.
Features
Bolted Dead End with Cable Guide
• Performance: Sustained load equivalent to 95% of cable RBS
• Ultimate mechanical strength of dead end components: 40,000 lbs.
• Break-away bolts ensure proper installation torque while eliminating the need for
specialized torque wrenches
• Optional Cable Guide (recommended) to train Optical Ground Wire down or
around structure
• Drilled and tapped for grounding lug, eliminating additional accessories for electrical bonding
• Shorter than formed wire dead ends, allowing installation from the support structure
• Faster installation than competitive designs, reducing installation costs
• Optional link plate available for extension from structures (see next page)
.75" (19.05 MM) DIA.
CLEVIS OPENING
1.09" (27.7 MM)
A
5/8" BREAK-AWAY BOLT (M14-METRIC)
LINK PLATE
(ORDERED SEPARATELY)
KEEPER
3"
(76.2 MM)
© 2008, AFL, all rights reserved. PP-3-00007, Revision 3, 7.31.12
Specifications are subject to change without notice.
3
Bolted Dead End for OPGW
(Stranded Stainless Steel Tube Type Cable)
5/8" BREAK-AWAY BOLT (M14-METRIC)
LINK PLATE
(ORDERED SEPARATELY)
KEEPER
BUSHED KEEPER
3"
(76.2 MM)
ODE
HexaCore
ODES
OPGW Dead End
MiniCore
ODES
S
YYY/YYY
S for Standed Stainless Range code in Decimal
(See Valid Cable Types) Inches (See Table 1)
X
##
"G" for Cable Guide,
"N" for No Cable
Guide
NOTES:1. For installation instructions, see pg 128.
2. Bushed end keeper not considered in number of keepers.
3. Cables above 26,000 lbs RBS have to be tested.
4. This deadend is approved only for AFL cables.
CALCULATING CROSS SECTIONAL AREA OF ALUMOWELD (PERCENT)
TABLE 1
PERCENT ALUMOWELD > 33%
AW AREA PERCENT= ((AW AREA)/(AW AREA + ALUMINUM AREA)) * 100
IF THE AW AREA PERCENT IS LESS THAN 33%, ADD ONE KEEPER.
PERCENT ALUMOWELD
LESS THAN 33%
OPGW RBS
NO. OF *
KEEPERS
KEEPER
DIMENSION NO. OF *
DESIGNATION "A"
KEEPERS
KEEPER
DIMENSION
DESIGNATION "A"
14000 OR LESS
14001-17000
17001-21000
21000-26000
26001-ABOVE**
7
8
9
10
11
07
08
09
10
11
08
09
10
11
11
28.38
30.78
33.18
35.58
37.98
8
9
10
11
11
30.78
33.18
35.58
37.98
37.98
AFL CABLE DESCRIPTION
S3—109/45/673
CABLE DIA.
CROSS SECTIONAL AREA
OF ALUMOWELD (MM2)
CROSS SECTIONAL AREA
OF ALUMINUM (MM2)
* NUMBER OF KEEPERS DOES NOT INCLUDE THE END BUSHED KEEPER.
* NUMBER OF KEEPERS NOT TO EXCEED 11.
* * SEE NOTE 3.
AFL NO.
ODES350/359GXX
ODES360/369GXX
ODES370/379GXX
ODES380/389GXX
ODES390/399GXX
ODES400/409GXX
ODES410/419GXX
ODES420/429GXX
ODES430/439GXX
ODES440/449GXX
ODES450/459GXX
ODES460/469GXX
ODES470/479GXX
ODES480/489GXX
Number of Keepers
(See Table 1, Keeper
Designation and
Calculating Cross
Sectional Area of
Alumoweld)
CABLE DIAMETER RANGE
MIN
MAX
0.350
0.359
0.360
0.369
0.370
0.379
0.380
0.389
0.390
0.399
0.400
0.409
0.410
0.419
0.420
0.429
0.430
0.439
0.440
0.449
0.450
0.459
0.460
0.469
0.470
0.479
0.480
0.489
AFL NO.
ODES490/499GXX
ODES500/509GXX
ODES510/519GXX
ODES520/529GXX
ODES530/539GXX
ODES540/549GXX
ODES550/559GXX
ODES560/569GXX
ODES570/579GXX
ODES580/589GXX
ODES590/599GXX
ODES600/609GXX
ODES610/619GXX
ODES620/629GXX
CABLE DIAMETER RANGE
MIN
MAX
0.490
0.499
0.500
0.509
0.510
0.519
0.520
0.529
0.530
0.539
0.540
0.549
0.550
0.559
0.560
0.569
0.570
0.579
0.580
0.589
0.590
0.599
0.600
0.609
0.610
0.619
0.620
0.629
AFL NO.
ODES630/639GXX
ODES640/649GXX
ODES650/659GXX
ODES660/669GXX
ODES670/679GXX
ODES680/689GXX
ODES690/699GXX
ODES700/709GXX
ODES710/719GXX
ODES720/729GXX
ODES730/739GXX
ODES740/749GXX
CABLE DIAMETER RANGE
MIN
MAX
0.630
0.639
0.640
0.649
0.650
0.659
0.660
0.669
0.670
0.679
0.680
0.689
0.690
0.699
0.700
0.709
0.710
0.719
0.720
0.729
0.730
0.739
0.740
0.749
© 2008, AFL, all rights reserved. PP-3-00007, Revision 3, 7.31.12
Specifications are subject to change without notice.
4
Bolted Dead End for OPGW
(Core Tube Type Cable)
LINK PLATE
(ORDERED SEPARATELY)
5/8" BREAK-AWAY BOLT (M14-METRIC)
KEEPER
3"
(76.2 MM)
ODE
CentraCore AlumaCore Slotted Core
ODEC
ODEC
ODEC
OPGW Dead End
C
YYY/YYY
Used for Alumacore, Range code in Decimal
Centracore, and Slotted Inches (See Table 1)
Core
X
##
"G" for Cable Guide,
"N" for No Cable
Guide
Number of Keepers
(See Table 1, Keeper
Designation)
NOTES:1. For installation instructions, see pg 128.
2. This deadend is approved only for AFL cables.
3. Cables above 30,000 lbs RBS have to be tested.
TABLE 1
OPGW RBS
14000 OR LESS
14001 - 17000
17001 - 21000
21000 - 26000
26001 - 30000
IF > 30001*
NO. OF *
KEEPERS
7
8
9
10
11
12
KEEPER
DESIGNATION
07
08
09
10
11
12
DIMENSION
"A"
25.98
28.38
30.78
33.18
35.58
37.98
* SEE NOTE 3
AFL NO.
ODEC350/359GXX
ODEC360/369GXX
ODEC370/379GXX
ODEC380/389GXX
ODEC390/399GXX
ODEC400/409GXX
ODEC410/419GXX
ODEC420/429GXX
ODEC430/439GXX
ODEC440/449GXX
ODEC450/459GXX
ODEC460/469GXX
ODEC470/479GXX
ODEC480/489GXX
CABLE DIAMETER RANGE
MIN
MAX
0.350
0.359
0.360
0.369
0.370
0.379
0.380
0.389
0.390
0.399
0.400
0.409
0.410
0.419
0.420
0.429
0.430
0.439
0.440
0.449
0.450
0.459
0.460
0.469
0.470
0.479
0.480
0.489
AFL NO.
ODEC490/499GXX
ODEC500/509GXX
ODEC510/519GXX
ODEC520/529GXX
ODEC530/539GXX
ODEC540/549GXX
ODEC550/559GXX
ODEC560/569GXX
ODEC570/579GXX
ODEC580/589GXX
ODEC590/599GXX
ODEC600/609GXX
ODEC610/619GXX
ODEC620/629GXX
CABLE DIAMETER RANGE
MIN
MAX
0.490
0.499
0.500
0.509
0.510
0.519
0.520
0.529
0.530
0.539
0.540
0.549
0.550
0.559
0.560
0.569
0.570
0.579
0.580
0.589
0.590
0.599
0.600
0.609
0.610
0.619
0.620
0.629
AFL NO.
ODEC630/639GXX
ODEC640/649GXX
ODEC650/659GXX
ODEC660/669GXX
ODEC670/679GXX
ODEC680/689GXX
ODEC690/699GXX
ODEC700/709GXX
ODEC710/719GXX
ODEC720/729GXX
ODEC730/739GXX
ODEC740/749GXX
CABLE DIAMETER RANGE
MIN
MAX
0.630
0.639
0.640
0.649
0.650
0.659
0.660
0.669
0.670
0.679
0.680
0.689
0.690
0.699
0.700
0.709
0.710
0.719
0.720
0.729
0.730
0.739
0.740
0.749
© 2008, AFL, all rights reserved. PP-3-00007, Revision 3, 7.31.12
Specifications are subject to change without notice.
5