Gauge from the front of the reel first and always begin alignment on the left side of the reel. After gauging from the front, gauge from the bottom of the reel using the same process. When gauging, move carriage or tooling bar so the gauge reads 1-1/2 times opposite of initial reading, as shown below. Initial Reading Opposite Number Setting Initial Reading Opposite Number Setting 0.010 -0.015 -0.010 0.015 0.015 -0.023 -0.015 0.023 0.020 -0.030 -0.020 0.030 0.025 -0.038 -0.025 0.038 0.030 -0.045 -0.030 0.045 0.035 -0.053 -0.035 0.053 0.040 -0.060 -0.040 0.060 0.045 -0.068 -0.045 0.068 0.050 -0.075 -0.050 0.075 0.055 -0.083 -0.055 0.083 0.060 -0.090 -0.060 0.090 0.065 -0.098 -0.065 0.098 0.070 -0.105 -0.070 0.105 0.075 -0.113 -0.075 0.113 0.080 -0.120 -0.080 0.120 0.085 -0.128 -0.085 0.128 0.090 -0.135 -0.090 0.135 0.095 -0.143 -0.095 0.143 0.100 -0.150 -0.100 0.150 NOTE: The gauge reads to the “ten-thousandths” of an inch and the last digit will read either zero or five. This is actually ½ of a thousandths. DISREGARD THIS LAST DIGIT as if it doesn't exist.