SE00044 In-Line Drinking Water ORP Sensor Hach

PRODUCT INFORMATION
PROCESS ANALYSIS
ELECTROCHEMISTRY
pHD-S sc: digital differential
electrode for pH and redox
➔L
"onger service life
➔2
"4-month phased
warranty*
➔P
"lug and play with
SC controllers
New type of design for longer
service life
Due to the closed design, the reference system of the pHD-S sc electrode does not come into contact with
the fluid that is being measured. This
means that no electrode poisoning can
occur. As a result, H2S in the wastewater cannot attack the electrode. The
much less soil-sensitive salt bridge
reduces the necessary cleaning in
comparison with systems fitted with
membranes. Dilution of the electrolyte
is also prevented.
Time-saving advantages
Whether in municipal or industrial
wastewater, drinking or process water,
the service life of the pHD-S sc electrode is up to three times longer and thus
ensures lower operating costs. The differential electrode needs calibrating
and cleaning less often. HACH LANGE
gives a 24-month phased warranty* on
all pHD sc probes.
PROCESS ANALYSIS_ELECTROCHEMISTRY
Technical data
54.6 mm (2.15 inches)
43.9 mm (1.73 inches)
1-inch NPT
29.5 mm (1.16 inches)
SB-R1SV
25M1A1025-115
57.2 mm (2.25 inches)
SPARE PARTS AND ACCESSORIES
pHD-S sc salt bridge
Reference solution (500 ml)
4.5 mm (0.179 inches)
LXV427.99.10001
LXV427.99.20001
LZX914.99.xx200
32.8 mm
(1.29 inches)
pHD-S sc pH
pHD-S sc ORP
Tank rim holder for probes (1")
35.8 mm (1.41 inches)
Order information
324.0 mm (12.755 inches)
Menu-driven 1-point or 2-point calibration
1 point calibration
3 m/s
2 bar overpressure
Probe body of stainless steel and Probe body of stainless steel
and Ryton (PVDF), salt bridge
Ryton (PVDF), salt bridge of
Ryton (PVDF), glass and titanium of Ryton (PVDF), platinum and
titanium electrode with Viton
electrode with Viton O-ring
O-ring
Digital to controller SC 100 or SC 1000
0.3 kg
44 mm x 342 mm (diam. x L)
10 m PUR
264.67 mm (10.42 inches)
Data transmission
Weight
Dimensions
Probe cable
pHD-S sc ORP
Differential electrode
NTC 300 Ohm
-2000 ... 2000 mV
0 ... 14 pH
-5 ... 75 °C
Automatic or manual
59.4 mm
(2.34 inches)
Calibration:
- pH
- temperature
Max. flow rate
Max. sample pressure
Material
1-inch NPT
pHD-S sc pH
Measuring method
Temperature probe
Measuring range
Measuring range temperature
Temperature compensation
HACH LANGE Services
Contact us to place an order,
request information or receive
technical support.
*24-month phased guarantee
Support on-site by expert
sales team
www.hach-lange.com up-to-date and secure, with
downloads, information and shop
- Free replacement
within the first 12 months from date of
purchase, provided the electrode has
been properly used and maintained.
- Unconditional replacement at 50 %
of list price during the first 24 months
from date of purchase.
DOC053.52.03255.Nov04
In the event of an electrode defect,
HACH LANGE guarantees: