HQT12FSD - ACC Compressors

HQT12FSD
PRODUCT SPECIFICATION
OPERATION:
Application:
Refrigerant:
Operation:
Cooling:
LBP / HST
R600a
Max. Ambient Temp:
(1) Max. Steady Discharge Temp:
(1,2) Max. Peak Discharge Temp:
Max. Steady Condensing Temp:
(2) Max. Peak Condensing Temp:
Max. Winding Temp:
Capillary / Valve
Static
Max. Impurities:
Max.Total Compressor Water Content:
43°C
120°C
135°C
55°C
70°C
130°C
30 mg
100 mg
COMPRESSOR:
Displacement:
Bore:
Stroke:
(3) Net Wt:
Case Size:
Oil Charge:
12.0 cc
27.00 mm
21.12 mm
Oil Type:
(4) Viscosity:
Suction Muffler:
8.8 kg
2 (h = 175.5 mm)
400 cc
Mineral
7 cst.
Semi-direct
h
ELECTRICAL:
Power Supply:
Voltage Limits:
Frequency:
Phase:
200 - 240V
170 - 264V
50 / 60 Hz
1 ph
Motor Type:
Electronic Control:
Rated Speed:
(5) Locked Rotor Current:
Phase Winding Resistance at 25°C:
Brushless, Sensorless, PMM
FSD38
1600 - 3600 rpm range
1.5 A / Electr.ly shutted down
11.5 ohm
The compressor terminals MUST NEVER be connected directly to the power supply!
(1) Measured 5cm. from the shell with insulated thermocouples
(2) For transient conditions during 'Pull Down'
(3) Net weight is with oil but without electrics
(4) Measured at 40°C
(5) Line current / Phase current
For rated performance, the suction line must be connected
to the stub marked 'AS' on the attached drawing.
AE 1586.1
Apr '07
Page 1
ACC reserves the right to change the data without prior notice
HQT12FSD
PRODUCT SPECIFICATION
PERFORMANCE:
220V 50Hz
(Graphs are at ASHRAE conditions)
Amps 1,50
1,25
3600 rpm
1,00
2400 rpm
0,75
1600 rpm
0,50
0,25
Input 200
Watts 180
160
140
120
100
80
60
40
C.o.P.2,40
3600 rpm
2400 rpm
1600 rpm
1600 rpm
2,30
2400 rpm
2,20
3600 rpm
2,10
2,00
1,90
1,80
1,70
1,60
1,50
1,40
1,30
410
3600 rpm
385
WATTS
360
335
2400 rpm
310
285
260
235
210
1600 rpm
185
160
135
Test Conditions:
Condensing Temp:
Liquid Temp:
Gas Return Temp:
Ambient Temp:
110
85
ASHRAE
55°C
32°C
32°C
32°C
CECOMAF
55°C
55°C
32°C
32°C
60
-35
AE 1586.1
-30
Apr '07
-25
-20
-15
Evaporating Temperature (°C)
Page 2
-10
-5
ACC reserves the right to change the data without prior notice
HQT12FSD
PRODUCT SPECIFICATION
220V 50Hz
PERFORMANCE:
ASHRAE:
Evaporating Temperature °C
-30
-25
-23,3
-20
-15
-10
Capacity
W
68
92
101
120
153
192
W/W
1,5
1,71
1,78
1,92
2,12
2,32
65
1,23
88
1,40
115
1,58
146
1,74
183
1,91
53
0,45
63
0,52
66
0,55
73
0,60
84
0,67
96
0,75
114
1,43
150
1,61
164
1,67
195
1,80
251
2,00
319
2,21
94
1,18
123
1,32
161
1,48
206
1,63
262
1,82
80
0,65
93
0,76
98
0,80
109
0,87
126
0,99
144
1,10
157
1,32
206
1,51
223
1,58
262
1,71
326
1,92
395
2,13
129
1,08
169
1,24
215
1,41
268
1,58
325
1,75
119
0,98
136
1,08
153
1,19
170
1,31
186
1,44
C.o.P.
1600 rpm
CECOMAF:
Capacity
W
C.o.P.
W/W
Input Power
ASHRAE:
Current
A
Capacity
W
C.o.P.
2400 rpm
CECOMAF:
W
W/W
Capacity
W
C.o.P.
W/W
Input Power
ASHRAE:
Current
A
Capacity
W
C.o.P.
3600 rpm
CECOMAF:
W
W/W
Capacity
W
C.o.P.
W/W
Input Power
Current
AE 1586.1
Apr '07
W
A
Page 3
141
1,12
ACC reserves the right to change the data without prior notice
HQT12FSD
PRODUCT SPECIFICATION
A) Autologic Mode Connection
- the compressor terminals MUST NEVER be connected directly to the power supply
CABLE CLAMP
LINE
L
NEUTRAL
THERMOSTAT
J1
N
L or N
TURBO (OPTIONAL)
L or N
EARTH
ELECTRONIC
CONTROL
EARTH
EXTERNAL HERMETIC
CONNECTOR
PHASE 1
NOT CONNECTED
PHASE 3
J2
PHASE 2
PHASE 1
MOTOR
PHASE 2
COMPRESSOR
B) Slave Mode Connection
PHASE 3
- the compressor terminals MUST NEVER be connected directly to the power supply
B.1) Serial
CABLE CLAMP
VCC
RX
RX
TX
LINE
J3
L
NEUTRAL
N
J1
EARTH
ELECTRONIC
CONTROL
EARTH
EXTERNAL HERMETIC
CONNECTOR
PHASE 1
NOT CONNECTED
PHASE 3
J2
PHASE 2
PHASE 1
MOTOR
PHASE 2
COMPRESSOR
PHASE 3
B.2) Frequency Modulation
CABLE CLAMP
LINE
VCC
J3
Signal
L
NEUTRAL
N
J1
EARTH
ELECTRONIC
CONTROL
EARTH
PHASE 1
NOT CONNECTED
PHASE 3
J2
PHASE 2
PHASE 1
MOTOR
COMPRESSOR
AE 1586.1
EXTERNAL HERMETIC
CONNECTOR
Apr '07
Page 4
PHASE 2
PHASE 3
ACC reserves the right to change the data without prior notice
HQT12FSD
PRODUCT SPECIFICATION
Recommended Transport Positions when
fitted into appliances
Mounting
Accessories
2
y
1
x
5
4
3
y
x = 26mm or 28.5mm
y = 9mm or 10.3mm
Other sizes available
1. Rubber grommet
2. Sleeve
3. Washer
4. Steel Pin
5. Clip
1
Upright
Tubes Down
Electrics Up
x
Compressor Labels
Warning
Connect to the
electronic
control only
PRODUCTION DATE
LOGO
ELECTRONIC
CONTROL
MODEL
use only with
control type
MANUFACTURER
< SUCTION
REFRIGERANT
CHECK
DIGIT
BAR CODE
VERSION CODE
APPROVALS
SERIAL
NUMBER
Electronic Control Label
LEAKAGE TEST
WARNING
MARKS
ELECTRICAL
CHARACTERISTICS
APPROVALS
ELECTRONIC
DRIVER TYPE
PRODUCT CODE
& DATE
AE 1586.1
Apr '07
Page 5
ACC reserves the right to change the data without prior notice