Catalogue page DCE-C - Stanpro Lighting Systems

Project:
Contractor:
DCE-C
LED DICE
CANOPY
13W (984 or 1354 lumens)
cULus listed
Suitable for wet locations
Description
Technical Specifications
This decorative LED series is suitable for many lighting environments. It can
be wall-mounted, suspended-mounted, and canopy-mounted making it a
great luminaire to create sight uniformity. It comes standard in a wide beam
angle and is also available with optional optics for a narrow beam angle. This
contemporary design will surely compliment any outdoor lighting space while
maintaining high-performance and efficiency standards.
W-50K
Photometric Report: DCE-C-LS1-W-50K-25
Page 1 of 2
Page 1 of 2
PHOTOMETRIC DISTRIBUTION
• Die cast housing with a glass lens
• Silver UV resistant powder coat finish is standard
• Input voltage: 120-277V AC
• High quality, long life LEDs
• 5000K colour temperature
• Low starting temperature of -40°C
• 4KVAC surge protection included
DIMENSIONS
4.92"
125 mm
Filename: DCE-C-LS1-W-50K-25
K
Manufacturer: STANPRO LIGHTING SYSTEMS
G SYSTEMS
Luminaire: WITH FRAM,HEAT SINK,OPTICS,GLASS
SINK,GLASS
Luminaire Cat: DCE-C-LS1-W/50K/25
Lamp: CREE CXA1512 5000K
0K
1.96"
50 mm
Ballast Desc: LP1013-36-C0300
Lamp Output: Total luminaire Lumens: 1316.3
ens: 981.7
Max Candela: 4,877.2 at Horizontal: 0°, Vertical: 0°
140°, Vertical: 20°
Input Wattage: 13.3
", W: 11.22")
Luminous Opening: Rectangle (L: 13.39", W: 11.22")
Test: QC-2341
Test Date: 2014-12-09
6.65"
169 mm
Test Lab: STANPRO LIGHTING SYSTEMS
G SYSTEMS
Photometry : Type C
Nema Type: 4 X 4
UTOFF
SHORT
58.2
64.6
p
Roadway Summary
Flood Summary
Cutoff Classification: Horizontal
SEMICUTOFF
Vertical
Efficiency Lumens
Spread
Distribution: Spread
Type
VS
Field (10%):
92.2%
98.8
Max Cd,
90 Deg905.5
Vert:
55.9132.7
Beam (50%):
87.9
Max Cd, 75.7%
80 to <90743.4
Deg:
57.979.6
Total: 100.3% 984.4 Lumens % Lamp
50.9%
Downward Street Side:
658.5
47.1%
Downward House Side:
670.3
50.9%
Downward Total: 1,328.8
100.9%
98%
Upward Street Side:
1.2%
Upward House Side:
3.3
Upward Total:
25.5
1.9%
Total Lumens: 1,354.3
102.9%
2.3%
Efficiency Lumens
20-30
30-40
40-50
50-60
60-70
70-80
80-90
Vertical
Spread
827.5
49.9
51.2
236.0
17.1
18.6
22.2
Total: 102.7% 1,351.4
1.7%
0.3%
Zonal
Lumen Summary
Lumens Per
Zone
Zone % Lumens
% Luminaire
Zone Lumens
Total Zone
Lumens % Total
0-30 4.7%
886.190-100 67.3%
0-10
46.5
15.6
1.6%
10-20
Horizontal
Spread
Field (10%): 62.9%
Beam (50%): 17.9%
50%
1.1%
100.3%
Flood Summary
0-40 13.8%
1,028.4100-110
78.1%7.0
135.5
0-60 21.5%
1,187.5110-120
90.2% 0
211.0
60-90 26.4%
103.3120-1307.8% 0
258.8
Lumens Per Zone
Zone Lumens % Total Zone
Lumens % Total
0-10
272.8
20.7% 90-100
19.0
1.4%
0.7%
10-20
380.1
28.9% 100-110
6.5
0.5%
0%
20-30
233.1
17.7% 110-120
0
0%
0%
30-40
142.3
10.8% 120-130
0
0%
0%
40-50
93.0
7.1% 130-140
0
0%
0%
50-60
66.1
5.0% 140-150
0
0%
0%
60-70
46.4
3.5% 150-160
0
0%
0%
70-80
31.9
2.4% 160-170
0
0%
0%
80-90
24.9
1.9% 170-180
0
0%
Lumen and specification chart
70-10017.4%
75.9130-1405.8% 0
171.3
90-120 5.3%
25.5140-1501.9% 0
51.7
0-90 3.7%
1,290.8150-160
98.1% 0
35.9
90-180 2.7%
25.5160-1701.9% 0
26.9
0-180 2.2%
1,316.3170-180100% 0
21.5
LED
package
S1
Voltage
120V
277V
System
Wattage
13
Drive current
/LED
300mA
Delivered
Lumens
General specifications
Delivered
lm/W
Lumens
With optics
1354
104.2
Lumen maintenance
lm/W
PF
THD
BUG
Reported L70
Without optics
984
75.7
0.99
0.95
11.86%
18.20%
121
>60 000
TM21
calculated
192 000
ordering guide
DCE
C
file:///C:/ProgramData/PhotometricsPro/temp/DCE-C-LS1-W-50K-25_rep.htm
csPro/temp/DCE-C-LS1-W-50K_rep.htm
8/5/2015
L
12/2/2015
S1
W
50K
Series
Direction
Lamp type
Lumen package
Voltage
Colour temperature
Casting colour
Options
DCE
C - Canopy
L - LED
S1 - Refer to lumen and
specification chart
W - 120-277V
50K - 5000K
Blank - Silver (standard)
SP - Special colour
25 - 25 degree optics
2233 rue de l’Aviation, Dorval, QC H9P 2X6
514.739.9984, 1.866.280.2332 •
1.866.265.8801 • www.stanprols.com
LM80 at (hrs)
10 000