162-960 1 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. A IF THE END REACTION IS 350# OR LESS THE FOLLOWING PERIMETER ANCHORING USING "F" PERIMETERS CAN BE USED. 162-017 "F" PERIMETER AT 1" FRAMING 162-176 AT 1/4" FRAMING PERIMETER ANCHORING TO CALCULATE END REACTIONS PERIMETER FASTENER 24" ON CENTER OR AS REQUIRED MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF) B IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. DRILL 1/2" DIA. HOLE FOR HOLE PLUGS. DRILL CLEARANCE HOLE FOR 1/4" FASTENER. MAXIMUM FASTENER SPACING IS 24". SEE BELOW FOR ADDITIONAL HEAD AND SILL FASTENERS. INTERIOR SEAL REQUIRED ONLY AT VISION AREAS 2 EQUALS END REACTION IN POUNDS EXAMPLE A 5' X 7' X 20 PSF 2 HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS = 350# CONTINUOUS SNAP-IN FILLER 162-021 6" SYSTEM 162-020 7-1/2" SYSTEM LENGTH EQUALS DLO MINUS 3-1/2" WHEN SHEAR BLOCKS ONLY OCCUR. LENGTH EQUALS DLO MINUS 9" WHEN "F" AND "T" ANCHORS OCCUR. IF THE END REACTION IS 350# OR LESS THE FOLLOWING PERIMETER ANCHORING USING "F" PERIMETERS CAN BE USED. USE GLAZING TEMPORARIES TO HOLD FRAMING MEMBERS TO PERIMETERS UNTIL PRESSURE PLATES ARE INSTALLED. 162-017 "F" PERIMETER AT 1" FRAMING 162-176 AT 1/4" FRAMING PERIMETER FASTENER 24" ON CENTER OR AS REQUIRED HEAD AND SILL CONDITIONS WITH FINISHED INTERIORS SHIM SILL CLOSE TO SETTING BLOCKS DO NOT LET PERIMETER SEAL COVER WEEP HOLES SNAP-IN SHIM SUPPORTS 162-316 6" SYSTEM 162-317 7-1/2" SYSTEM 1/4" FASTENER SHIMS AT THE HEAD AND SILL, INSTALL FASTENERS 6" EACH SIDE OF VERTICALS AND NO MORE THAN 24" ON CENTER. AT LEAST 3 FASTENERS ARE REQUIRED PER LITE OPENING. 420-460 OR 027-633 HOLE PLUG 420-460 OR 027-633 HOLE PLUG 6" PERIMETER PRESSURE PLATE 162-505 1" FRAMING 162-506 1/4" FRAMING REFERENCE FABRICATION DETAILS SHEET #2. 6" LAST BAY HORIZ. REQUIRES NOTCH. REFERENCE DETAILS SHEET #3. 1/4" FASTENER THIS ANCHORING PROVIDES ADEQUATE SUPPORT FOR THE WALL PROVIDED THE END REACTION AT THE VERTICALS DOES NOT EXCEED 750#. HOWEVER, THE PERIMETER STRUCTURE AND THE PERIMETER FASTENERS ABILITY TO CARRY THE LOAD MUST BE CHECKED PER JOB. CONTACT FACTORY ENGINEERING FOR ASSISTANCE. AT PERIMETER PRESSURE PLATES TOP AND BOTTOM END CAPS REQUIRED FOR ALL VERTICALS REFERENCE INSTRUCTIONS 162-970 JAMB CONDITION AT FINISHED INTERIOR IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. 1/2" HOLE SNAP-IN FILLER AND SEAL ONLY REQUIRED AT VISION AREAS SHIM SILL CLOSE TO SETTING BLOCKS DO NOT LET PERIMETER SEAL COVER WEEP HOLES B PERIMETER PRESSURE PLATES CAN BE USED WITH "F" AND "T" ANCHORS REFERENCE SHEET #2 JAMB CONDITION AT EXPOSED INTERIOR TUBULAR MULLIONS MAY ALSO BE USED AT JAMBS 95449-70 07/11/08 DRAWING: 1 1600 SYSTEM STOCK LENGTH INSTRUCTIONS PART NUMBER 162-960 1 OF 5 ORDER: SHT: 162-960 2 OF 5 C IF THE END REACTION IS 750# AND GREATER "F" AND "T" ANCHORS ARE REQUIRED AT EACH VERTICAL. PERIMETER MEMBERS MAY BE ANCHORED AS SHOWN IN METHODS "A" OR "B" DEPENDING UPON THE JOB CONDITIONS. "F" OR "T" ANCHORS SHOULD NOT BE USED IN CONDUCTION WITH STEEL REINFORCING WITHOUT CHECKING THE STRUCTURAL INTEGRITY OF THE ANCHORS. CONTACT FACTORY ENGINEERING FOR ASSISTANCE. STRUCTURAL INTEGRITY OF ANCHOR AND FASTENERS MUST BE CHECKED BY FACTORY ENGINEERS. PERIMETER MEMBERS MAY BE ANCHORED AS SHOWN IN METHODS "A" OR "B" DEPENDING UPON THE JOB CONDITIONS. USE THIS SHEAR BLOCK WITH OPEN BACK HORIZONTALS WHEN POSSIBLE. IF TUBULAR HORIZONTALS ARE USED A NOTCH IS REQUIRED. REFERENCE FABRICATION DETAILS ON SHEET #4. REFERENCE INSTALLATION INSTRUCTION 162-983 EXTERIOR FRAME PERIMETERS PRESSURE PLATE FABRICATION WHEN USING "F" AND "T" ANCHORS SHOWN FOR PERIMETER ANCHORING "C", THE FOLLOWING PERIMETER FRAMING CAN BE USED AT THE HEAD AND SILL ONLY. "F" ANCHORS REQUIRE TUBULAR VERTICAL MULLIONS AT JAMBS. LENGTH OF HORIZONTAL PRESSURE PLATE EQUALS DAYLITE OPENING MINUS 3/4". ATTACHMENT HOLES ARE FACTORY PUNCHED AT 3" ON CENTER. .266 DIA.(H DRILL). BUT CAN NOT BE USED WITH SHEAR BLOCK/ ANCHOR SHOWN FOR PERIMETER ANCHORING "D". USE SHEAR BLOCKS 162-384 6" SYSTEM 162-385 7 1/2" SYSTEM WEEP HOLES ARE TO BE LOCATED 3-5/8" FROM EACH END AS SHOWN DRILL 5/16" HOLES SILL POSITION SHOWN. UNLESS NOTED OTHERWISE WEEPS NOT REQUIRED AT HEAD 3-5/8" 25/32" PERIMETER ANCHORING D HEAD/SILL SHEAR BLOCK/ANCHORS. REFERENCE STEP #4, SHEET #2, AND STEP #7, SHEET #3 IN THE 162-970 INSTALLATION INSTRUCTIONS. 1-1/4" USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. WEEP HOLES "F" ANCHORS CAN NOT BE USED WITH OPEN BACK VERTICAL JAMBS. VERTICAL HOLE PREPS ARE THE SAME AS TYPICAL SHEAR BLOCKS. "F" ANCHOR FOR JAMBS 162-308 AT 6" SYSTEM 162-311 AT 7 1/2" SYSTEM 162-354 AT 10 1/2" SYSTEM STRUCTURAL SHIMMING IS REQUIRED AT SILL TO ACCOMPLISH DESIGNED PERIMETER SEAL WIDTH. "T" ANCHOR FOR INTERMEDIATE VERTICAL 162-309 AT 6" SYSTEM 162-312 AT 7 1/2" SYSTEM 162-355 AT 10 1/2" SYSTEM JAMB SHEAR BLOCK/ANCHOR 162-314 AT 6" SYSTEM 162-315 AT 7 1/2" SYSTEM MULLION SHEAR BLOCK/ANCHOR 162-342 AT 6" SYSTEM 162-343 AT 7 1/2" SYSTEM HEAD CONDITION 3" MAX PERIMETER FRAME 162-203 1" FOR 6" SYSTEM 162-204 1" FOR 7 1/2" SYSTEM 162-205 1/4" FOR 6" SYSTEM 162-206 1/4" FOR 7 1/2" SYSTEM ATTACHMENT HOLES DLO MINUS 3/4" STOCK LENGTH PART NUMBER 162-335 SHIM SILL CLOSE TO SETTING BLOCKS 162-505 1" FRAMING 162-506 1/4" FRAMING TYPICAL VERTICAL MULLION SILL CONDITION DO NOT LET PERIMETER SEAL COVER WEEP HOLES TYPICAL "T" ANCHOR FASTENER PREPS AS REQUIRED. CONTACT FACTORY ENGINEERING FOR ASSISTANCE. VERTICAL PRESSURE PLATE LENGTH EQUALS VERTICAL MULLION HEIGHT. JAMB CONDITION CLIPS AS REQUIRED FOR WIND LOAD TYPICAL VERTICAL MULLION ATTACHMENT HOLES ARE FACTORY PUNCHED AT 3" ON CENTER. .266 DIA.(H DRILL). 95449-70 07/11/08 DRAWING: 1 1600 SYSTEM STOCK LENGTH INSTRUCTIONS PART NUMBER 162-960 2 OF 5 ORDER: SHT: 162-960 3 OF 5 7/32" COVER BOTTOM EXTRUSION 162-006 5/16" DIA. WEEP HOLES. LOCATED AT BOTH ENDS. REFERENCE APPROVED SHOP DRAWINGS FOR VERTICAL LENGTHS AND HORIZONTAL LOCATIONS. SPLICE FIXNG SCREW, STOP SCREW AND JAMB SIDE F-ANCHOR ALIGNMENT PREPS ARE ALL SIMILAR TO PREPS NOTED BELOW. REFERENCE SHOP DRAWINGS AND 162-970 INSTRUCTIONS. REFERENCE APPROVED SHOP DRAWINGS FOR VERTICAL LENGTHS AND HORIZONTAL LOCATIONS. SPLICE FIXNG SCREW, STOP SCREW AND JAMB SIDE F-ANCHOR ALIGNMENT PREPS ARE ALL SIMILAR TO PREPS NOTED BELOW. REFERENCE SHOP DRAWINGS AND 162-970 INSTRUCTIONS. 6" SYSTEM 2" EXTRUSION 162-204 SHOWN DLO MINUS 1/16" VERTICAL EXTERIOR COVER LENGTH EQUALS PRESSURE PLATE LENGTH UNLESS NOTED OTHERWISE ON APPROVED SHOP DRAWINGS EXTRUSION 162-003 SHOWN +0 -1/32" 7/8" 1 1/4" HORIZONTAL TOP OR BOTTOM HORIZONTAL TOP OR BOTTOM +0 -1/32" TYP. 3 1/2" HORIZONTAL CENTER LINE DRILL .182 DIA. HOLES (#14 DRILL) VERTICAL DRILL FIXTURE 162-374 FIXTURE "V" NOTCH IS HORIZONTAL C/L HORIZONTAL CENTER LINE EDGE OF DRILL FIXTURE IS ALSO TOP OR BOTTOM OF HORIZONTAL. DRILL .173 DIA. HOLES (#17 DRILL) DRILL .173 DIA. HOLES (#17 DRILL) WEEP LOCATION FOR DEEP AND CUSTOM COVERS 1 1/2" 7/8" HORIZONTAL CENTER LINE VERTICAL DRILL FIXTURE 162-351 FIXTURE "V" NOTCH IS HORIZONTAL C/L +0 -1/32" 1 3/8" 2" HORIZONTAL TOP OR BOTTOM 9/32" EXTRUSION 162-064 SHOWN EXTRUSION 162-095 EXTRUSION 162-094 EXTRUSION 162-001 SHOWN REFERENCE APPROVED SHOP DRAWINGS FOR VERTICAL LENGTHS AND HORIZONTAL LOCATIONS. SPLICE FIXNG SCREW, STOP SCREW AND JAMB SIDE F-ANCHOR ALIGNMENT PREPS ARE ALL SIMILAR TO PREPS NOTED BELOW. REFERENCE SHOP DRAWINGS AND 162-970 INSTRUCTIONS. 10-1/2" SYSTEM 7-1/2" SYSTEM EXTRUSION 162-203 SHOWN VERTICAL MULLI0N FABRICATION 1 1/4" LENGTH OF HORIZONTAL COVER EQUALS DAYLITE OPENING MINUS 1/16". VERTICAL MULLI0N FABRICATION VERTICAL MULLI0N FABRICATION 1 1/4" EXTERIOR COVER FABRICATION EDGE OF DRILL FIXTURE IS ALSO TOP OR BOTTOM OF HORIZONTAL. VERTICAL DRILL FIXTURE 162-351 FIXTURE "V" NOTCH IS HORIZONTAL C/L EDGE OF DRILL FIXTURE IS ALSO TOP OR BOTTOM OF HORIZONTAL. AT 10-1/2" SYSTEM DRILL THESE 4 HOLES AT 6" SYSTEM DRILL THESE 2 HOLES AT 7-1/2" SYSTEM DRILL THESE 2 HOLES 95449-73 03/12/09 DRAWING: 1 1600 SYSTEM STOCK LENGTH INSTRUCTIONS PART NUMBER 162-960 3 OF 5 ORDER: SHT: 162-960 4 OF 5 HORIZONTAL FABRICATION HORIZONTAL FABRICATION HORIZONTAL FABRICATION HORIZONTAL FABRICATION HORIZONTAL AND OPEN BACK FILLER LENGTH EQUALS DAYLITE OPENING MINUS 1/32". 5/8" 5/8" NOTCH POSITION ON END OF HORIZONTAL EXTRUSION 162-094 SHOWN POSITION 162-375 BY ALIGNING SPRING PINS WITH EXTRUSION EDGE .228 DIA. HOLE (#1 DRILL) .438 X 82° CTSK OR COIN EXTRUSION 162-090 SHOWN 13/16" 4-5/8" NOTCH 0.111 DRILL THESE 2 HOLES FOR LAST BAY SHEAR BLOCKS 13/16" 1 1/4" 5/8" EXTRUSION 162-001 SHOWN OPEN BACK HORIZONTAL NOTCH FOR "F" SHEAR BLOCK AT TYPE "D" ANCHORING. DRILL THESE 2 HOLES FOR TYPICAL SHEAR BLOCKS HORIZONTAL END DRILL FIXTURE 162-352 6", 7-1/2" AND 10-1/2" SYSTEMS TUBULAR HORIZONTAL NOTCH FOR "F" SHEAR BLOCK AT TYPE "D" ANCHORING. HEAD/SILL END DRILL FIXTURE 162-393 AT PERIMETER FRAME EXTRUSION 162-001 SHOWN 13/16" 2 3/16" NOTCH 1 1/4" EXTRUSION 162-065 SHOWN 1/4" 2 1/4" 1/4" NOTCH 1 5/8" NOTCH 1 1/4" ADDITIONAL SHEAR BLOCK PREP FOR 10-1/2" SYSTEM 1 1/4" 5/8" .228 DIA. HOLE (#1 DRILL) .438 X 82° CTSK 5/8" 13/16" EXTRUSION 162-065 SHOWN 5/8" .182 DIA. TAPPING HOLE (#14 DRILL) .228 DIA. HOLE (#1 DRILL) .438 X 82° CTSK EXTRUSION 162-203 SHOWN 5/8" POSITION 162-393 BY ALIGNING SPRING PINS WITH EXTRUSION EDGES 5/8" EXTRUSION 162-065 SHOWN 5/8" .228 DIA. HOLE (#1 DRILL) .438 X 82° CTSK OR COIN 5/8" NOTCH MUST BE MADE AFTER LAST BAY SHEAR BLOCK HOLE PREPS. 4 5/8" NOTCH 1 1/4" 5/8" ADDITIONAL LAST BAY SHEAR BLOCK PREP AND NOTCH FOR 10-1/2" SYSTEM .228 DIA. CLEAR HOLE (#1 DRILL) 13/16" 95449-70 07/11/08 DRAWING: 1 1600 SYSTEM STOCK LENGTH INSTRUCTIONS PART NUMBER 162-960 4 OF 5 ORDER: SHT: 162-960 5 OF 5 HORIZONTAL FABRICATION LAST BAY HORIZONTAL NOTCH FOR SHEAR BLOCK AT TYPE "B" ANCHORING. ADAPTER FABRICATION PERIMETER FILLER FABRICATION SPANDREL ADAPTERS PERIMETER FILLER NOTCH BOTH ENDS ALL HEAD AND SILL FILLERS. ADAPTERS ARE SQUARE CUT EXTRUSION 162-001 SHOWN EXTRUSION 162-019 VERTICAL ADAPTER LENGTH EQUALS DAYLITE OPENING PLUS 1-3/8" EXTRUSION 162-019 BELOW A VERTICAL SPLICE, VERTICAL ADAPTER LENGTH EQUALS DAYLITE OPENING PLUS 3/16" PERIMETER FABRICATION 3/8" NOTCH 1-1/2" EXTRUSION 162-022 EXTRUSION 162-023 1-1/2" 3/8" 1/4" HORIZONTAL ADAPTER LENGTH EQUALS DAYLITE OPENING MINUS 1/16" 2" NOTCH 1/4" HORIZONTAL LENGTH EQUALS DAYLITE OPENING PLUS 1-1/2" VERTICAL MULLION NOTCH FOR "F" PERIMETER AT TYPE "A" ANCHORING. 10-1/2" SYSTEM TUBULAR HORIZONTAL NOTCH AT TYPE "C" ANCHORING. NOTCH TONGUE 15/16" NOTCH EXTRUSION 162-065 SHOWN 5 3/4" NOTCH 6 23/32" NOTCH 162-001 SHOWN VERTICAL FILLERS ARE SQUARE CUT AND THE SAME LENGTH AS VERTICAL MULLIONS. NOTCH TONGUE 15/16" NOTCH 5/16" 162-013 SHOWN 95449-70 07/11/08 DRAWING: 1 1600 SYSTEM STOCK LENGTH INSTRUCTIONS PART NUMBER 162-960 5 OF 5 ORDER: SHT:
© Copyright 2025 Paperzz