PERIMETER ANCHORING

162-960 1 OF 5
USE THESE INSTRUCTIONS IN CONJUNCTION
WITH INSTALLATION INSTRUCTIONS 162-970.
A
IF THE END REACTION IS 350# OR LESS
THE FOLLOWING PERIMETER ANCHORING
USING "F" PERIMETERS CAN BE USED.
162-017 "F"
PERIMETER AT
1" FRAMING
162-176 AT
1/4" FRAMING
PERIMETER ANCHORING
TO CALCULATE END REACTIONS
PERIMETER
FASTENER 24"
ON CENTER OR
AS REQUIRED
MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF)
B
IF THE END REACTION IS 350# TO 750#
THE FOLLOWING PERIMETER ANCHORING
CAN BE USED.
DRILL 1/2" DIA. HOLE FOR HOLE PLUGS.
DRILL CLEARANCE HOLE FOR 1/4" FASTENER.
MAXIMUM FASTENER SPACING IS 24".
SEE BELOW FOR ADDITIONAL HEAD AND SILL
FASTENERS.
INTERIOR SEAL
REQUIRED ONLY AT
VISION AREAS
2
EQUALS END REACTION IN POUNDS
EXAMPLE
A
5' X 7' X 20 PSF
2
HEAD AND SILL
CONDITIONS
WITH EXPOSED
INTERIORS
= 350#
CONTINUOUS
SNAP-IN FILLER
162-021 6" SYSTEM
162-020 7-1/2" SYSTEM
LENGTH EQUALS DLO MINUS 3-1/2"
WHEN SHEAR BLOCKS ONLY OCCUR.
LENGTH EQUALS DLO MINUS 9"
WHEN "F" AND "T" ANCHORS OCCUR.
IF THE END REACTION IS 350# OR LESS
THE FOLLOWING PERIMETER ANCHORING
USING "F" PERIMETERS CAN BE USED.
USE GLAZING
TEMPORARIES TO
HOLD FRAMING MEMBERS
TO PERIMETERS UNTIL
PRESSURE PLATES
ARE INSTALLED.
162-017 "F"
PERIMETER AT
1" FRAMING
162-176 AT
1/4" FRAMING
PERIMETER
FASTENER 24"
ON CENTER OR
AS REQUIRED
HEAD AND SILL
CONDITIONS
WITH FINISHED
INTERIORS
SHIM SILL
CLOSE TO
SETTING
BLOCKS
DO NOT LET
PERIMETER SEAL
COVER WEEP
HOLES
SNAP-IN SHIM
SUPPORTS
162-316 6" SYSTEM
162-317 7-1/2" SYSTEM
1/4"
FASTENER
SHIMS
AT THE HEAD AND SILL, INSTALL FASTENERS
6" EACH SIDE OF VERTICALS AND NO MORE
THAN 24" ON CENTER. AT LEAST 3 FASTENERS
ARE REQUIRED PER LITE OPENING.
420-460
OR
027-633
HOLE
PLUG
420-460
OR
027-633
HOLE
PLUG
6"
PERIMETER PRESSURE PLATE
162-505 1" FRAMING
162-506 1/4" FRAMING
REFERENCE FABRICATION
DETAILS SHEET #2.
6"
LAST BAY
HORIZ. REQUIRES
NOTCH. REFERENCE
DETAILS SHEET #3.
1/4" FASTENER
THIS ANCHORING PROVIDES ADEQUATE SUPPORT
FOR THE WALL PROVIDED THE END REACTION AT
THE VERTICALS DOES NOT EXCEED 750#.
HOWEVER, THE PERIMETER STRUCTURE AND THE
PERIMETER FASTENERS ABILITY TO CARRY THE
LOAD MUST BE CHECKED PER JOB.
CONTACT FACTORY ENGINEERING FOR ASSISTANCE.
AT PERIMETER PRESSURE PLATES
TOP AND BOTTOM END CAPS REQUIRED
FOR ALL VERTICALS
REFERENCE INSTRUCTIONS 162-970
JAMB CONDITION
AT FINISHED
INTERIOR
IF THE END REACTION IS 350# TO 750#
THE FOLLOWING PERIMETER ANCHORING
CAN BE USED.
1/2" HOLE
SNAP-IN FILLER
AND SEAL ONLY
REQUIRED AT
VISION AREAS
SHIM SILL
CLOSE TO
SETTING
BLOCKS
DO NOT LET
PERIMETER SEAL
COVER WEEP
HOLES
B
PERIMETER PRESSURE PLATES CAN BE
USED WITH "F" AND "T" ANCHORS
REFERENCE SHEET #2
JAMB CONDITION
AT EXPOSED
INTERIOR
TUBULAR MULLIONS MAY ALSO BE USED AT JAMBS
95449-70
07/11/08
DRAWING:
1
1600 SYSTEM
STOCK LENGTH INSTRUCTIONS
PART NUMBER
162-960 1 OF 5
ORDER:
SHT:
162-960 2 OF 5
C
IF THE END REACTION IS 750# AND
GREATER "F" AND "T" ANCHORS ARE
REQUIRED AT EACH VERTICAL.
PERIMETER MEMBERS MAY BE ANCHORED AS
SHOWN IN METHODS "A" OR "B" DEPENDING
UPON THE JOB CONDITIONS.
"F" OR "T" ANCHORS SHOULD NOT BE USED
IN CONDUCTION WITH STEEL REINFORCING
WITHOUT CHECKING THE STRUCTURAL
INTEGRITY OF THE ANCHORS.
CONTACT FACTORY ENGINEERING FOR
ASSISTANCE.
STRUCTURAL INTEGRITY OF
ANCHOR AND FASTENERS MUST BE
CHECKED BY FACTORY ENGINEERS.
PERIMETER MEMBERS MAY BE ANCHORED AS
SHOWN IN METHODS "A" OR "B" DEPENDING
UPON THE JOB CONDITIONS.
USE THIS SHEAR BLOCK WITH OPEN BACK
HORIZONTALS WHEN POSSIBLE. IF TUBULAR
HORIZONTALS ARE USED A NOTCH IS
REQUIRED. REFERENCE FABRICATION
DETAILS ON SHEET #4.
REFERENCE INSTALLATION INSTRUCTION 162-983
EXTERIOR FRAME PERIMETERS
PRESSURE PLATE FABRICATION
WHEN USING "F" AND "T" ANCHORS SHOWN
FOR PERIMETER ANCHORING "C", THE
FOLLOWING PERIMETER FRAMING CAN BE
USED AT THE HEAD AND SILL ONLY. "F"
ANCHORS REQUIRE TUBULAR VERTICAL
MULLIONS AT JAMBS.
LENGTH OF HORIZONTAL PRESSURE PLATE
EQUALS DAYLITE OPENING MINUS 3/4".
ATTACHMENT HOLES ARE FACTORY PUNCHED
AT 3" ON CENTER. .266 DIA.(H DRILL).
BUT CAN NOT BE USED WITH SHEAR BLOCK/
ANCHOR SHOWN FOR PERIMETER ANCHORING "D".
USE SHEAR BLOCKS
162-384 6" SYSTEM
162-385 7 1/2" SYSTEM
WEEP HOLES ARE TO BE LOCATED
3-5/8" FROM EACH END AS SHOWN
DRILL 5/16" HOLES
SILL POSITION SHOWN. UNLESS NOTED
OTHERWISE WEEPS NOT REQUIRED AT HEAD
3-5/8"
25/32"
PERIMETER ANCHORING
D
HEAD/SILL SHEAR BLOCK/ANCHORS.
REFERENCE STEP #4, SHEET #2,
AND STEP #7, SHEET #3 IN THE
162-970 INSTALLATION INSTRUCTIONS.
1-1/4"
USE THESE INSTRUCTIONS IN CONJUNCTION
WITH INSTALLATION INSTRUCTIONS 162-970.
WEEP HOLES
"F" ANCHORS CAN NOT BE USED WITH
OPEN BACK VERTICAL JAMBS.
VERTICAL HOLE PREPS ARE THE SAME
AS TYPICAL SHEAR BLOCKS.
"F" ANCHOR FOR JAMBS
162-308 AT 6" SYSTEM
162-311 AT 7 1/2" SYSTEM
162-354 AT 10 1/2" SYSTEM
STRUCTURAL SHIMMING IS REQUIRED AT
SILL TO ACCOMPLISH DESIGNED
PERIMETER SEAL WIDTH.
"T" ANCHOR FOR INTERMEDIATE VERTICAL
162-309 AT 6" SYSTEM
162-312 AT 7 1/2" SYSTEM
162-355 AT 10 1/2" SYSTEM
JAMB SHEAR BLOCK/ANCHOR
162-314 AT 6" SYSTEM
162-315 AT 7 1/2" SYSTEM
MULLION SHEAR BLOCK/ANCHOR
162-342 AT 6" SYSTEM
162-343 AT 7 1/2" SYSTEM
HEAD CONDITION
3" MAX
PERIMETER FRAME
162-203 1" FOR 6" SYSTEM
162-204 1" FOR 7 1/2" SYSTEM
162-205 1/4" FOR 6" SYSTEM
162-206 1/4" FOR 7 1/2" SYSTEM
ATTACHMENT
HOLES
DLO MINUS 3/4"
STOCK LENGTH
PART NUMBER 162-335
SHIM SILL
CLOSE TO
SETTING
BLOCKS
162-505
1" FRAMING
162-506
1/4" FRAMING
TYPICAL
VERTICAL
MULLION
SILL CONDITION
DO NOT LET
PERIMETER SEAL
COVER WEEP
HOLES
TYPICAL
"T" ANCHOR
FASTENER PREPS AS REQUIRED.
CONTACT FACTORY ENGINEERING FOR
ASSISTANCE.
VERTICAL PRESSURE
PLATE LENGTH EQUALS
VERTICAL MULLION
HEIGHT.
JAMB CONDITION
CLIPS AS
REQUIRED
FOR WIND
LOAD
TYPICAL VERTICAL MULLION
ATTACHMENT HOLES ARE FACTORY PUNCHED
AT 3" ON CENTER. .266 DIA.(H DRILL).
95449-70
07/11/08
DRAWING:
1
1600 SYSTEM
STOCK LENGTH INSTRUCTIONS
PART NUMBER
162-960 2 OF 5
ORDER:
SHT:
162-960 3 OF 5
7/32"
COVER
BOTTOM
EXTRUSION
162-006
5/16" DIA. WEEP
HOLES. LOCATED AT
BOTH ENDS.
REFERENCE APPROVED SHOP DRAWINGS FOR
VERTICAL LENGTHS AND HORIZONTAL LOCATIONS.
SPLICE FIXNG SCREW, STOP SCREW AND JAMB
SIDE F-ANCHOR ALIGNMENT PREPS ARE ALL
SIMILAR TO PREPS NOTED BELOW. REFERENCE
SHOP DRAWINGS AND 162-970 INSTRUCTIONS.
REFERENCE APPROVED SHOP DRAWINGS FOR
VERTICAL LENGTHS AND HORIZONTAL LOCATIONS.
SPLICE FIXNG SCREW, STOP SCREW AND JAMB
SIDE F-ANCHOR ALIGNMENT PREPS ARE ALL
SIMILAR TO PREPS NOTED BELOW. REFERENCE
SHOP DRAWINGS AND 162-970 INSTRUCTIONS.
6" SYSTEM
2"
EXTRUSION
162-204
SHOWN
DLO MINUS 1/16"
VERTICAL EXTERIOR
COVER LENGTH EQUALS
PRESSURE PLATE LENGTH
UNLESS NOTED OTHERWISE
ON APPROVED SHOP DRAWINGS
EXTRUSION
162-003
SHOWN
+0
-1/32"
7/8"
1 1/4"
HORIZONTAL
TOP OR BOTTOM
HORIZONTAL
TOP OR BOTTOM
+0
-1/32"
TYP.
3 1/2"
HORIZONTAL
CENTER LINE
DRILL .182 DIA. HOLES
(#14 DRILL)
VERTICAL DRILL
FIXTURE 162-374
FIXTURE "V" NOTCH
IS HORIZONTAL C/L
HORIZONTAL
CENTER LINE
EDGE OF DRILL
FIXTURE IS ALSO
TOP OR BOTTOM
OF HORIZONTAL.
DRILL .173 DIA. HOLES
(#17 DRILL)
DRILL .173 DIA. HOLES
(#17 DRILL)
WEEP LOCATION FOR DEEP
AND CUSTOM COVERS
1 1/2"
7/8"
HORIZONTAL
CENTER LINE
VERTICAL DRILL
FIXTURE 162-351
FIXTURE "V" NOTCH
IS HORIZONTAL C/L
+0
-1/32"
1 3/8"
2"
HORIZONTAL
TOP OR BOTTOM
9/32"
EXTRUSION
162-064
SHOWN
EXTRUSION
162-095
EXTRUSION
162-094
EXTRUSION
162-001
SHOWN
REFERENCE APPROVED SHOP DRAWINGS FOR
VERTICAL LENGTHS AND HORIZONTAL LOCATIONS.
SPLICE FIXNG SCREW, STOP SCREW AND JAMB
SIDE F-ANCHOR ALIGNMENT PREPS ARE ALL
SIMILAR TO PREPS NOTED BELOW. REFERENCE
SHOP DRAWINGS AND 162-970 INSTRUCTIONS.
10-1/2" SYSTEM
7-1/2" SYSTEM
EXTRUSION
162-203
SHOWN
VERTICAL MULLI0N FABRICATION
1 1/4"
LENGTH OF HORIZONTAL COVER
EQUALS DAYLITE OPENING MINUS 1/16".
VERTICAL MULLI0N FABRICATION
VERTICAL MULLI0N FABRICATION
1 1/4"
EXTERIOR COVER FABRICATION
EDGE OF DRILL
FIXTURE IS ALSO
TOP OR BOTTOM
OF HORIZONTAL.
VERTICAL DRILL
FIXTURE 162-351
FIXTURE "V" NOTCH
IS HORIZONTAL C/L
EDGE OF DRILL
FIXTURE IS ALSO
TOP OR BOTTOM
OF HORIZONTAL.
AT 10-1/2" SYSTEM
DRILL THESE
4 HOLES
AT 6" SYSTEM
DRILL THESE
2 HOLES
AT 7-1/2" SYSTEM
DRILL THESE
2 HOLES
95449-73
03/12/09
DRAWING:
1
1600 SYSTEM
STOCK LENGTH INSTRUCTIONS
PART NUMBER
162-960 3 OF 5
ORDER:
SHT:
162-960 4 OF 5
HORIZONTAL FABRICATION
HORIZONTAL FABRICATION
HORIZONTAL FABRICATION
HORIZONTAL FABRICATION
HORIZONTAL AND OPEN BACK FILLER LENGTH
EQUALS DAYLITE OPENING MINUS 1/32".
5/8"
5/8"
NOTCH
POSITION ON
END OF
HORIZONTAL
EXTRUSION
162-094
SHOWN
POSITION 162-375
BY ALIGNING SPRING
PINS WITH EXTRUSION
EDGE
.228 DIA. HOLE (#1 DRILL)
.438 X 82° CTSK OR COIN
EXTRUSION
162-090
SHOWN
13/16"
4-5/8"
NOTCH
0.111
DRILL THESE 2
HOLES FOR LAST
BAY SHEAR
BLOCKS
13/16"
1 1/4"
5/8"
EXTRUSION
162-001
SHOWN
OPEN BACK HORIZONTAL NOTCH FOR "F" SHEAR
BLOCK AT TYPE "D" ANCHORING.
DRILL THESE 2
HOLES FOR TYPICAL
SHEAR BLOCKS
HORIZONTAL END
DRILL FIXTURE 162-352
6", 7-1/2" AND 10-1/2" SYSTEMS
TUBULAR HORIZONTAL NOTCH FOR "F" SHEAR
BLOCK AT TYPE "D" ANCHORING.
HEAD/SILL END
DRILL FIXTURE 162-393
AT PERIMETER FRAME
EXTRUSION 162-001 SHOWN
13/16"
2 3/16"
NOTCH
1 1/4"
EXTRUSION
162-065
SHOWN
1/4"
2 1/4"
1/4"
NOTCH
1 5/8"
NOTCH
1 1/4"
ADDITIONAL SHEAR BLOCK PREP FOR 10-1/2" SYSTEM
1 1/4"
5/8"
.228 DIA. HOLE (#1 DRILL)
.438 X 82° CTSK
5/8"
13/16"
EXTRUSION
162-065
SHOWN
5/8"
.182 DIA. TAPPING HOLE (#14 DRILL)
.228 DIA. HOLE (#1 DRILL)
.438 X 82° CTSK
EXTRUSION
162-203
SHOWN
5/8"
POSITION 162-393 BY ALIGNING
SPRING PINS WITH EXTRUSION EDGES
5/8"
EXTRUSION
162-065
SHOWN
5/8"
.228 DIA. HOLE (#1 DRILL)
.438 X 82° CTSK OR COIN
5/8"
NOTCH MUST BE MADE AFTER LAST BAY SHEAR BLOCK
HOLE PREPS.
4 5/8" NOTCH
1 1/4"
5/8"
ADDITIONAL LAST BAY SHEAR BLOCK PREP AND NOTCH
FOR 10-1/2" SYSTEM
.228 DIA. CLEAR HOLE (#1 DRILL)
13/16"
95449-70
07/11/08
DRAWING:
1
1600 SYSTEM
STOCK LENGTH INSTRUCTIONS
PART NUMBER
162-960 4 OF 5
ORDER:
SHT:
162-960 5 OF 5
HORIZONTAL FABRICATION
LAST BAY HORIZONTAL NOTCH FOR SHEAR BLOCK
AT TYPE "B" ANCHORING.
ADAPTER FABRICATION
PERIMETER FILLER FABRICATION
SPANDREL ADAPTERS
PERIMETER FILLER NOTCH BOTH ENDS
ALL HEAD AND SILL FILLERS.
ADAPTERS ARE SQUARE CUT
EXTRUSION 162-001 SHOWN
EXTRUSION
162-019
VERTICAL ADAPTER LENGTH
EQUALS DAYLITE OPENING
PLUS 1-3/8"
EXTRUSION
162-019
BELOW A VERTICAL SPLICE, VERTICAL
ADAPTER LENGTH
EQUALS DAYLITE OPENING
PLUS 3/16"
PERIMETER FABRICATION
3/8"
NOTCH
1-1/2"
EXTRUSION
162-022
EXTRUSION
162-023
1-1/2"
3/8"
1/4"
HORIZONTAL ADAPTER LENGTH
EQUALS DAYLITE OPENING
MINUS 1/16"
2" NOTCH
1/4"
HORIZONTAL LENGTH EQUALS
DAYLITE OPENING PLUS 1-1/2"
VERTICAL MULLION NOTCH FOR "F" PERIMETER
AT TYPE "A" ANCHORING.
10-1/2" SYSTEM TUBULAR HORIZONTAL NOTCH AT TYPE "C"
ANCHORING.
NOTCH TONGUE
15/16" NOTCH
EXTRUSION 162-065 SHOWN
5 3/4" NOTCH
6 23/32" NOTCH
162-001
SHOWN
VERTICAL FILLERS ARE SQUARE
CUT AND THE SAME LENGTH
AS VERTICAL MULLIONS.
NOTCH TONGUE
15/16" NOTCH
5/16"
162-013
SHOWN
95449-70
07/11/08
DRAWING:
1
1600 SYSTEM
STOCK LENGTH INSTRUCTIONS
PART NUMBER
162-960 5 OF 5
ORDER:
SHT: