LM-534B Tone channel selective level meter Auto-sweep function enables automated measurement of all channels! Output of selected channel signals is enabled! [Overview] [Features] There are cases where multiple channel signals (determined by frequency band) are multiplexed to transfer on a single transmission line of remote monitoring control equipment, telemeter, etc. When signal levels of a specific channel are measured on this kind of transmission lines using an ordinary flat level meter, the other signals should be stopped. However, LM-534B does not require stopping other signals so that a specific channel signal level can be easily measured. Signal-out function (signal output) enables outputting signals of a specific channel; so, if you use it together with a level variation recorder, it enables monitoring of a specific channel for a long period of time. ◆ Various filters such as 50 baud (18 CH) ,200 baud (8 CH),300 baud (2 CH),600 baud (3 CH),1200 baud (1 CH) and f0 ±50 Hz (200 Hz to 4 kHz in 50 Hz step) are provided. ◆ Just a single operation enables starting measurement of each channel out of multiplexed signals. ◆ The band-pass filter of f0 ±50 Hz (f0: 200 Hz to 4 kHz in in 50 Hz step) enables measuring single-frequency signals used in control signal, etc. ◆ Switching to a flat level meter enables measuring the total level of all channels. ◆ Auto-sweep function provides automatic measurement of all channels (CH) of each filter and stores them to memory. ◆ Peak hold function records max. and min. values; so, it provides easy checking of level fluctuation. ◆ Setting input impedance to HIGH enables measuring a line where DC is superimposed. ◆ Measurement results saved to MMC (multimedia card) in CSV format can be transfered to a PC and edited with spreadsheet software. ◆ Small-sized and handy. ◆ Dry cell battery can be used in addition to the attached AC adapter. Successor to LM-534. [Differences] - LM-534B: Supports only printers for outputting measurement results to an external device. - LM-534B: Supports only MMC for outputting measurement results to an external device. External appearance Application ◆ Measurement of signals multiplexed on a dedicated circuit. Transmission line Signal transmission device Signal transmission device Wireless channel Power line carrier circuit Transmission line carrier circuit Receiving part Receiving part Remote monitoring and control system, etc. Remote monitoring and control system, etc. Space Mark LM-534B LM-534B Receive filter Resistance attenuator Limiting amplifier Frequency discriminator Output converter FS oscillator Resistance attenuator Transmission filter ◆ Measurement of signals multiplexed on a telephone line (only for HIGH connection) Uplink Downlink Automatic metering device (HIGH connection) (HIGH connection) (HIGH connection) (HIGH connection) Network Various sensors Centralized monitoring center LM-534B User's premise LM-534B Functionality ◆ Signal-out (signal output) function Signal-out (signal output) function enables outputting signals of a specific channel. Transferring these signals to a connected level variation recorder (our DLR-202, etc.) enables the long-term measurement of level fluctuation. Transmission line Remote monitoring device ◆ Measurement with peak hold function Display and record max. and min. values of measured signal levels. LM-534B Level variation Level variation recorder recorder Remote monitoring device ◆ Auto-sweep function Measure consecutive signal levels in multiplexed signals of each channel automatically. Measurement data is saved to memory. ◆ Monitoring of specific frequency with band-pass filter Band-pass filter enables measuring signal levels automatically up to 77 points (200 Hz to 4 kHz frequency band in 50 Hz step). It is best fitted for monitoring of signal level of a specific frequency (monitoring control signal, etc.) and measuring noise components of a communication line. ◆ Saving measurement results Measurement results can be saved to MMC (multimedia card) in CSV format. Measurement results saved in MMC can be edited with spreadsheet software on a PC. Oi El ectri c LM- 534B TONECHANEL CHAKER < S I G N A L F I L T E R : C H : f 0 : B W : 6 0 0 Ω - < N O O U T > 20 0 . d B m M A X + 1 5 . 0 d B m M I N - 2 3 . 3 d B m M M C > 0 9 : 1 2 : 3 4 HIGH 600Ω 600Ω FILTER TYPE FLAT Measurement results 5 0 B 1 4 2 5 H z 1 0 0 H z BPF 50B BPF 200B BPF 600B BPF 1200B BPF f0±50Hz PEAK HOLD REAL MAX/MIN AUTO SWEEP BPF 300B SIGNAL OUT ENTER DATA SAVE MEMORY READ SELECT WRITE Description of operation part Filter selection part of a measured channel. FLAT means the total level of all channels. Operation part Connection setting part of a transmission line. Set either 600 Ohm termination or HIGH connection. Auto-sweep setting part. Measure automatically consecutive signal levels of all channels selected with a filter. Peak hold setting part. Set peak holds (max. and min. values). Signal-out setting part. Output signals of a selected channel to an external device (measuring a level at the same time). Menu selection part. Select a menu in the LCD display. Data save setting part. Save measurement results to MMC. Internal memory operation part. ■ Specifications No. Item 1 Environme Performance guarantee Operation guarantee 2 Power Battery AC adapter Built-in battery (backup) 3 External Dimension/ Mass 4 T erminal Measurement terminal AC adapter jack 5 Insulation AC terminals (AC adapter) ■ Standards Specifications 0 to 40 degC/ 20 to 85% (non condensing) Same as the performance guarantee AA x 4 Usable at AC 100V ±10% (50/60 Hz) by using ACP-311M AC adapter Backup for settings and clock available (approx. 2 days with super capacitor) Approx. H 208 x W 96 x D 50 mm (protruding parts not included)/ approx. C2-11P ACP-311M for AC adapter connection DC 500 V/ 1000 MOhm or more AA size rechargeable battery (battery voltage 1.2 V) can be used. No. Item 1 Level T erminal Measureme Input impedance Measurement frequency Level measurement range Specifications C2-11P 600 Ohm±5% balanced/ HIGH(50 KOhm or higher) 150 Hz to 10 kHz at FLAT Level measurement : -70 to +20 dBm with overflow/underflow display At signal-out : -50 to +5 dBm with overflow/underflow display Resolution 0.1 dB Measurement accuracy ±1 dB Maximum input level +20 dBm 2 Signal Output impedance 600 Ohm ±5% balanced Output part Output frequency range 200 Hz to 10 kHz Input/Output level deviation ±1.0 dB (between -50 and +5 dBm) 3 Frequency 50 baud Center frequency : f0 = 425 to 3315 Hz (170 Hz step/18 CH) Selection Passband width (BW) : 100 Hz 200 baud Center frequency : f0 = 800 to 2800 Hz (400 Hz step/6 CH) and f0 = 1700 Hz, 2100 Hz (2 CH) Passband width (BW) : 260 Hz 300 baud Center frequency : f0 = 1080 Hz, 1750 Hz (2 CH) Passband width (BW) : 260 Hz 600 baud Center frequency : f0 = 1200 Hz, 1500 Hz, 2400 Hz Passband width (BW) : 460 Hz 1200 baud Center frequency : f0 = 1700 Hz Passband width (BW) : 1000 Hz : f0 ±50 Hz Center frequency : f0 = 200 Hz to 4 kHz (50 Hz step/77 points) Passband width (BW) : 100 Hz Accessories Measurement cordPWT-123 (MIPS-electric clips) AC adapter ACP-311M Dry battery AA Case PC-800 (soft case) Instruction manual 1 1 4 1 1 Carrying case (PC-800) Note: Specifications and external appearance are subject to change without notice for improvement. Inquiries Head Office 3-6, Kikuna 7-chome, Kohoku-ku, Yokohama, 222-0011, Japan TEL:81-45-433-3051 FAX:81-45-401-2194 Hokkaido Branch 4-4-18, Odori Higashi, Chuo-ku, Sapporo, 060-0041, Japan Tohoku Branch 3-12-2, Ake Dori, Izumi-ku, Sendai, 981-3206, Japan TEL:81-22-377-1721 FAX:81-22-377-1726 Chubu Branch 2-4-17, Tsurumai Showa-ku, Nagoya, 466-0064, Japan TEL:81-52-882-4651 FAX:81-52-882-4652 Osaka Branch 1-21-39, Esaka-cho, Suita, Osaka, 564-0063, Japan TEL:81-6-6388-6001 FAX:81-6-6388-6502 Hiroshima Branch Kyushu Branch KA1501286B 5-5, Fukuro-cho, Naka-ku, Hiroshima, 730-0036, Japan 4-8-25, Tenjin Chuo-ku, Fukuoka, 810-0001, Japan TEL:81-11-222-7395 FAX:81-11-271-1560 TEL:81-82-241-8680 FAX:81-82-241-8283 TEL:81-92-731-2201 FAX:81-92-731-2238 You can find the latest information of new products on our web site. http://www.ooi.co.jp E-mail : [email protected]
© Copyright 2026 Paperzz