ESTA Report

MAC III Profile, Standard Lens , Zoom at Minimum (11.5°) Photometric Report
Martin R&D Optics Laboratory, 31-Jul-2008
Data sheet conforms to American National Standard E1.9 - 2001
Product
Catalog number
Lens Option
Spread
IES file
MAC III Profile
90206000
Standard
Minimum
MACIIIProfile_Standard_Minimum.ies
Procedure
The goniometer consists of a computerized goniometer IRB 6000 and a single cell THOMA Color
Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data
collection. The goniometer is initialized so that the center of the luminaire's front lens is positioned 7
m from the luxmeter. The luminaire is rotated around the center of the lens per IESNA's type B
photometry in 1° increments in the horizontal plane (rotational) and 1° increments in the vertical plane
(radial). Readings are taken using a manufacturer-calibrated test lamp and normalized to the lamp's
nominal output.
Test lamp
Model
Rated wattage
Rated life
Rated color temp.
Rated voltage
Rated output
Osram HTI 1500W/60/P50 Lok-it!
1500 W
750 hours
6000 K
100 V
145000 lumens
Test conditions
Lamp wattage
AC supply
Lamp adjustment
Lamp age
Focus
Gate diameter
Color inserted
Effects inserted
1500 W
227 V/50Hz
Peak distribution
9 hours
Open gobo
32 mm
no
no
Ballast
Type
Ballast factor
Electronic
1.000
Output
Total
One-tenth peak
Half-peak
Efficiency
Efficacy
31500 lumens
31300 lumens
21200 lumens
22 %
18 lumens per watt
Illuminance
Cutoff angle
One-tenth-peak angle
Half-peak angle
Cutoff diameter
One-tenth-peak diam.
Half-peak diam.
11.5°
11°
7°
0.201 x distance
0.193 x distance
0.122 x distance
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
Intended throw
Focus range
Luminous intensity
Luminaire type
4 - 45 meters
4 meters to infinity
2394000 candela
Far field
100%=23,940 lux at 10m
(distance from origin)=(throw distance) X (throw distance multiplier)
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
MAC III Profile, Standard Lens , Zoom at Median (34°) Photometric Report
Martin R&D Optics Laboratory, 31-Jul-2008
Data sheet conforms to American National Standard E1.9 - 2001
Product
Catalog number
Lens Option
Spread
IES file
MAC III Profile
90206000
Standard
Median
MACIIIProfile_Standard_Median.ies
Procedure
The goniometer consists of a computerized goniometer IRB 6000 and a single cell THOMA Color
Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data
collection. The goniometer is initialized so that the center of the luminaire's front lens is positioned 7
m from the luxmeter. The luminaire is rotated around the center of the lens per IESNA's type B
photometry in 2° increments in the horizontal plane (rotational) and 2° increments in the vertical plane
(radial). Readings are taken using a manufacturer-calibrated test lamp and normalized to the lamp's
nominal output.
Test lamp
Model
Rated wattage
Rated life
Rated color temp.
Rated voltage
Rated output
Osram HTI 1500W/60/P50 Lok-it!
1500 W
750 hours
6000 K
100 V
145000 lumens
Test conditions
Lamp wattage
AC supply
Lamp adjustment
Lamp age
Focus
Gate diameter
Color inserted
Effects inserted
1500 W
227 V/50Hz
Peak distribution
9 hours
Open gobo
32 mm
no
no
Ballast
Type
Ballast factor
Electronic
1.000
Output
Total
One-tenth peak
Half-peak
Efficiency
Efficacy
33300 lumens
33300 lumens
22100 lumens
23 %
19 lumens per watt
Illuminance
Cutoff angle
One-tenth-peak angle
Half-peak angle
Cutoff diameter
One-tenth-peak diam.
Half-peak diam.
34°
32°
22°
0.611 x distance
0.573 x distance
0.389 x distance
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
Intended throw
Focus range
Luminous intensity
Luminaire type
4 - 45 meters
4 meters to infinity
259000 candela
Far field
100%=2,590 lux at 10m
(distance from origin)=(throw distance) X (throw distance multiplier)
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
MAC III Profile, Standard Lens , Zoom at Maximum (55°) Photometric Report
Martin R&D Optics Laboratory, 31-Jul-2008
Data sheet conforms to American National Standard E1.9 - 2001
Product
Catalog number
Lens Option
Spread
IES file
MAC III Profile
90206000
Standard
Maximum
MACIIIProfile_Standard_Maximum.ies
Procedure
The goniometer consists of a computerized goniometer IRB 6000 and a single cell THOMA Color
Analyzer TF5 luxmeter that provides luminous intensity measurements for computerized data
collection. The goniometer is initialized so that the center of the luminaire's front lens is positioned 7
m from the luxmeter. The luminaire is rotated around the center of the lens per IESNA's type B
photometry in 2° increments in the horizontal plane (rotational) and 2° increments in the vertical plane
(radial). Readings are taken using a manufacturer-calibrated test lamp and normalized to the lamp's
nominal output.
Test lamp
Model
Rated wattage
Rated life
Rated color temp.
Rated voltage
Rated output
Osram HTI 1500W/60/P50 Lok-it!
1500 W
750 hours
6000 K
100 V
145000 lumens
Test conditions
Lamp wattage
AC supply
Lamp adjustment
Lamp age
Focus
Gate diameter
Color inserted
Effects inserted
1500 W
227 V/50Hz
Peak distribution
9 hours
Open gobo
32 mm
no
no
Ballast
Type
Ballast factor
Electronic
1.000
Output
Total
One-tenth peak
Half-peak
Efficiency
Efficacy
33900 lumens
33800 lumens
21500 lumens
23 %
19 lumens per watt
Illuminance
Cutoff angle
One-tenth-peak angle
Half-peak angle
Cutoff diameter
One-tenth-peak diam.
Half-peak diam.
55°
53°
35°
1.041 x distance
0.997 x distance
0.631 x distance
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
Intended throw
Focus range
Luminous intensity
Luminaire type
4 - 45 meters
4 meters to infinity
100000 candela
Far field
100%=1,000 lux at 10m
(distance from origin)=(throw distance) X (throw distance multiplier)
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10
Olof Palmes Allé 18, 8200 Århus N, Denmark
Tel. +45 87 40 00 00 | Fax +45 87 40 00 10