SHEET INDEX J.A.T.C. SOUTH GREENHOUSE UPGRADE JORDAN SCHOOL DISTRICT 12723 PARK AVENUE RIVERTON, UTAH 84065 ARCHITECTURAL A0.00 A1.01 A2.01 A1.02 A0.01 COVER SHEET GREEN HOUSE FLOOR PLAN ROOF PLAN MISC. DETAILS DEMO FLOOR PLAN MECHANICAL M0.00 M1.01 M2.01 M2.02 M3.01 M3.02 M4.01 MECHANICAL COVER SHEET MECHANICAL DEMO FLOOR PLAN NEW MECHANICAL PLAN ROOF MECHANICAL PLAN MECHANICAL ISOMETRICS MECHANICAL SCHEDULE AND DETAILS MECHANICAL SPECIFICATIONS ELECTRICAL ELECTRICAL COVER SHEET DEMO ELECTRICAL PLAN NEW ELECTRICAL PLAN ELECTRICAL ONE-LINE AND DETAILS ELECTRICAL SPECIFICATIONS 845 SOUTH 220 EAST OREM, UTAH 84058 PH: (801) 229-0088 FAX: (801) 229-0089 MECHANICAL PLUMBING ELECTRICAL MKK CONSULTING ENGINEERS, INC. MKK CONSULTING ENGINEERS, INC. MKK CONSULTING ENGINEERS, INC. 4760 SOUTH HIGHLAND DRIVE, SUITE 106 SALT LAKE CITY, UTAH 84115 PHONE: 801.360.7024 4760 SOUTH HIGHLAND DRIVE, SUITE 106 SALT LAKE CITY, UTAH 84115 PHONE: 801.360.7024 4760 SOUTH HIGHLAND DRIVE, SUITE 106 SALT LAKE CITY, UTAH 84115 PHONE: 801.360.7024 Copyright © 2009, Sandstrom Architecture J.A.T.C. SOUTH - GREENHOUSE UPGRADE E0.00 E1.01 E2.01 E3.01 E4.01 GENERAL NOTES CONTRACTOR SHALL FIELD VERIFY ALL EXISITNG STRUCTURES, DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPENCIES. C. PRIOR TO STARTING DEMOLITION, THE CONTRACTOR SHALL BE RESPONSIBLE TO MAKE SURE THAT ALL REQUIRED PERMITS, BONDS, AND APPROVALS HAVE BEEN OBTAINED. ALL PERMIT AND BOND FEES ARE TO BE PAID BY THE OWNER. D. THE GENERAL CONTRACTOR IS TO REMAIN WITHIN THE CONTRACT LIMITS. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL TO PATCH, REPLACE, AND REPAIR ALL CONCRETE SIDEWALK/CURB/GUTTER, ASPHALT PAVEMENT AND SOD EFFECTED BY THE NEW CONSTRUCTION OUTSIDE OF THE CONTRACT LIMIT LINES DUE TO NEW CONSTRUCTION. E. CONTRACTOR SHALL PATCH, REPLACE AND REPAIR ALL EXISTING STRUCTURES AND FIXTURES EFFECTED BY NEW CONSTRUCTION. F. OWNER WILL OCCUPY SITE AND BUILDING DURING ENTIRE CONSTRUCTION PERIOD. COOPERATE WITH OWNER DURING CONSTRUCTION OPERATIONS TO MINIMIZE CONFLICTS AND FACILITATE OWNER USAGE. PERFORM WORK SO AS NOT TO INTERFERE WITH OWNER'S DAY-TO-DAY OPERATIONS. MAINTAIN EXISTING EXITS UNLESS OTHERWISE INDICATED. G. THE OWNER RESERVES THE RIGHT TO REMOVE ANY SALVAGEABLE MATERIALS RESULTING FROM DEMOLITION WORK AND SITE CLEARING. REMAINING MATERIAL THEN BECOME THE PROPERTY OF THE GENERAL CONTRACTOR TO BE PROPERLY DISPOSED. H. ALL STRUCTURAL FILL SHALL CONSIST OF IMPORTED GRANULAR SOIL (SEE GEOTECH REPORT). ON SITE SILT AND CLAY SOIL MAY NOT BE USED AS STRUCTURAL FILL. COORDINATE WITH GEOTECH AND STRUCTURAL SHEETS. J. FOR COMPLETE INFORMATION PERTAINING TO DEMOLITION, REFER TO INDIVIDUAL ENGINEERING PLANS. K. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PROTECT THE EXISTING ARCHITECTURAL, ELECTRICAL, PLUMBING AND MECHANICAL ITEMS DURING THE DEMOLITION PHASE. (PATCH, REPLACE, AND REPAIR TO PROVIDE A SMOOTH TRANSITION BETWEEN NEW AND OLD CONSTRUCTION.) L. CONTRACTOR SHALL TAKE NECESSARY MEASURES TO PROTECT ALL NEW FACILITIES DURING THE CONTRUCTION PERIOD UNTIL THE DESIGN GRADE AND COVER HAVE BEEN REACHED AND WORK HAS BEEN ACCEPTED BY OWNER. M. CONTRACTOR TO PROVIDE DUST BARRIER, SAFTEY BARRIER AND CONSTRUCTION SCHEDULE TO DISTRICT PRIOR TO CONSTRUCTION ACTIVITIY IN THIS AREA. SHEET NOTES 1 REMOVE EXISTING EXTERIOR CONCRETE WALKS, PREP SURFACE FOR NEW CONCRETE PAD FOR EVAP. COOLERS. NEW EXTERIOR CONCRETE PADS TO MEET 4500 PSI. SEE SPEC. LEGEND AND MECHANICAL SHEETS. SPECIFICATION LEGEND 1.) All work shall conform with ACI 301, latest edition. 2.) Use type I/II portland cement. 3.) Concrete mix - 4,500 psi compressive strength with 3/4" maximum aggregate size. 4.) Maximum w/c ratio, including fly ash = 0.50 5.) Steel reinforcing - #4 bar @ 18" o.c. ew. Position bar at 1 1/2" below to of slab. 6.) Slab thickness = 4". 1 REVISION/ISSUE V.I.F. DATE APPROX. 8' - 9" S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt EXTERIOR CAST -IN-PLACE CONCRETE 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com 12723 PARK AVENUE RIVERTON, UTAH 84065 B. JORDAN SCHOOL DISTRICT IT IS RECOMMENDED THAT ALL CONTRACTORS VISIT THE PROJECT PRIOR TO SUBMITTING THEIR BIDS. IT SHALL BE THE RESPONSIBILITY OF EACH BIDDER TO UNDERSTAND THE FULL SCOPE OF THE EXISTING CONSTRUCTION, DEMOLITION REQUIRED AND NEW CONSTRUCTION. NO ADDITIONAL COMPENSATION WILL BE GIVEN FOR NOT FULLY UNDERSTANDING THE SCOPE OF THE PROJECT. J.A.T.C. SOUTH - GREENHOUSE UPGRADE A. PROJECT NO. APPROX. 51' - 8" V.I.F. DATE SA-1527 FEBRUARY 2, 2016 KJM DRAWN BY CHECKED BY SES / CLL SHEET DESCRIPTION DEMO FLOOR PLAN 2/12/2016 4:11:09 PM SHEET NUMBER north DEMOLITION PLAN SCALE: 1/8" = 1'-0" 1 A0.01 GENERAL NOTES 10 10 8 10 10 8 8 10 A. CONTRACTOR TO VERIFY ALL WALL STRUCTURES AND BEAM LOCATIONS ABOVE PRIOR TO ANY DEMOLITION. REPORT ANY DISCREPENCY TO ARCHITECT. B. CONTRACTOR TO PROVIDE DUST BARRIER AND SCHEDULE TO DISTRICT PRIOR TO CONSTRUCITON ACTIVITY. C. CONTRACTOR TO VERIFY DIMENSIONS GIVEN FOR VERIFICATION OF WALL LAYOUT WITH ACTUAL FIELD CONDITIONS. D. IT SHALL BE THE REPONSIBILITY OF THE CONTRACTOR TO PATCH, REPAIR OR REPLACE AND EXISTING STRUCTURES AND FIXTURES AFFECTED BY DEMOLITION AND CONSTRUCTION. E. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT EXISTING ARCHITECTURAL, ELECTRICAL, MECHANICAL AND PLUMBING ITEMS DURING THE CONSTRUCTION. F. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE DUST BARRIERS AS REQUIRED DURING CONSTRUCITON TO PROTECT AREAS OF SCHOOL ADJACENT DURING CONSTRUCTION. G. ALL CABINETS ARE TO HAVE LOCKS. H. SEE ELECTRICAL SHEETS FOR LOCATIONS OF OUTLETS, SWITCHES, DATA, TELEPHONE, TELEVISION, INTERCOMS, CLOCKS, SPEAKERS, HORNS, STROBES, ETC. J. COORDINATE BETWEEN ENLARGED FLOOR PLANS AND INTERIOR ELEVATIONS FOR MISCELLANEOUS ITEMS THAT MAY ONLY BE SHOWN ON ONE OR THE OTHER. 10 9 10 7 A1.02 10 7 A1.02 7 A1.02 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com 10 2 3 4 NORTH EAST INTERIOR ELEVATION 1/4" = 1'-0" SCALE: SOUTH INTERIOR ELEVATION 4 SCALE: 1/4" = 1'-0" 3 5 6 7 8 9 10 OWNER PROVIDED 6'-0" x 38'-0" FIXED GREEN HOUSE TABLES. (NIC) OWNER PROVIDED 3'-0" x 9'-0" FIXED GREEN HOUSE TABLES. (NIC) NEW 2-BASIN UTILITY SINK WITH SPRAYERS & STOPPERS IN EACH BASIN, SEE PLUMBING SHEETS. 5'-0" x 12'-0" GALVINIZED STEEL COUNTER WITH STORAGE BELOW, SEE 'TYPICAL STUDENT WORK AREA' DETAIL. EXISTING STEEL COLUMN. NEW EMERGENCY EYEWASH AND SHOWER INSTALLED ON COLUMN. WATER PROVIDED OVERHEAD. SEE PLUMBING SHEETS. 5'-2" x 12'-2" GALVINIZED STEEL COUNTER WITH STORAGE BELOW, SEE 'TYPICAL ADA STUDENT WORK AREA' DETAIL. NEW EVAPORATIVE COOLER ON NEW CONCRETE PAD, SET AS CLOSE TO EXISTING BUILDING AS POSSIBLE. SEE MECHANICAL SHEETS. NEW WALL EXHAUST FAN, SEE MECHANICAL SHEETS. UNISTRUT SUPPORTS AS NEEDED. CLASSROOM 3' - 0" SCOPE OF WORK 2 2 3 9' - 1" 2 7 6' - 0" 1 5 A1.02 2 2 A1.02 4' - 0" 8 1 5 A1.02 1 1 A1.02 1 1 A1.02 6' - 0" 4 A1.01 5 1 5 5 6 1 5 5 DATE REVISION/ISSUE 6' - 0" 5 GREEN HOUSE 5' - 0" 3 4 8 4' - 0" M 1 1 AG. SHOP 6' - 0" 5 38' - 0" 10' - 6" 38' - 0" 10' - 6" 4' - 0" 4' - 0" M 2/12/2016 4:11:12 PM 2 M 1 5 38' - 0" 6' - 1" SA-1527 PROJECT NO. 1 DATE 8 FEBRUARY 2, 2016 KJM 6' - 0" DRAWN BY CHECKED BY SES / CLL SHEET DESCRIPTION 5' - 1" S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt CLASSROOM 12723 PARK AVENUE RIVERTON, UTAH 84065 1 JORDAN SCHOOL DISTRICT 8 A1.02 J.A.T.C. SOUTH - GREENHOUSE UPGRADE SHEET NOTES 5 5 5 5 5 5 GREEN HOUSE FLOOR PLAN A1.01 5 5 5 5 5 5 4 BID ALTERNATES 9 SCOPE OF WORK north OVERALL MAIN FLOOR SCALE: 1/8" = 1'-0" #1 1 PROVIDE BID ALTERNATE FOR STUDENT WORK AREAS TO BE CONSTRUCTED WITH STAINLESS STEEL WORKTOPS AND PLASTIC LAMINATE FACES BASED ON TMI SYSTEMS. SEE SPECIFICATION LEGEND. SHEET NUMBER A1.01 SPECIFICATION LEGEND STAINLESS STEEL WORK AREAS Manufacturer: Custom Fabricated Model #: Custom Dimensions: Per Plan Utility Requirements: None Accessories: A) Stainless steel bottom shelf. B) Provide with drawers per details. C) Finished sides and cabinet base. D) Stainless steel adjustable bullet feet on steel frame as per details. E) Stainless steel under and middle shelves as per details. F) Finished stainless steel face panel and front base sealed to floor G) Stainless steel removable base plate attached to feet at back of counter as per details. 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com Installation Instructions:A) Set and level as per plan. B) Clip and seal back splash to wall. (ALTERNATE #1) WORK AREAS Manufacturer: Model #: Dimensions: Utility Requirements: Based on TMI Systems See elevations Per Plan None Stainless Steel Counter Tops: 1.) All nominal 1" thick Stainless Steel clad countertops shown on drawings are constructed with 1" particleboard core laminated top face with HGS (.048) high-pressure decorative laminate, with BKH backer underside. Provide tight joint fasteners where needed. All exposed edges, including edges of backsplash where used, Stainless Steel banding. Exposed edges and corners are machine profiled to 1/8" radius for safety. Decorative Laminates: 1.) High pressure decorative laminate VGS (.028), NEMA Test LD-3-2005, (vertical grade). 2.) High pressure decorative laminate HGS (.048), NEMA Test LD-3-2005, (horizontal grade). 3.) High-pressure cabinet liner CLS (.020), NEMA Test LD-32005. 4.) Thermally Fused Melamine laminate tested to meet NEMA Test LD-3-2005, color as selected by Architect from grey, beige, or white. 5.) High-pressure backer BKH (.048), (.039), (.028), meeting NEMA Test LD3-2005. TURNED DOWN EDGE 2" EXHAUST FAN, SEE MECHANICAL SHEETS EVAPORATIVE COOLER DUCTWORK, SEE MECHANICAL SHEETS 30 DEGREE RETURN EXISTING MULLIONS TO REMAIN 1/2" EXISTING MULLIONS TO REMAIN NORTH EAST INTERIOR ELEVATION1 SCALE: 6 A1.02 Sim 1/2" = 1'-0" TYP. SIDE WALL PENETRATION 8 SCALE: 1/2" = 1'-0" TYP. 2" TURNED DOWN EDGE 7 STAINLESS STEEL BACK STAINLESS STEEL BACK STAINLESS STEEL BACK 1" X 4" STAINLESS STEEL BRACING (TYP) 1" X 4" STAINLESS STEEL BRACING (TYP) 1" X 4" STAINLESS STEEL BRACING (TYP) STAINLESS STEEL TOP WITH 3/4" RADIUS COVED CORNERS. STAINLESS STEEL TOP WITH 3/4" RADIUS COVED CORNERS. 6 A1.02 2" TURNED DOWN STAINLESS STEEL EDGE. Sim 6 A1.02 2" TURNED DOWN STAINLESS STEEL EDGE. STAINLESS STEEL UNDER SHELF WITH 3/4" COVE CORNERS STAINLESS STEEL DRAWER WITH LOCKS TURNED DOWN STAINLESS STEEL EDGE TURNED DOWN STAINLESS STEEL EDGE TURNED DOWN STAINLESS STEEL EDGE STAINLESS STEEL REMOVEABLE BASE STAINLESS STEEL REMOVEABLE BASE STAINLESS STEEL REMOVEABLE BASE ADJUSTABLE BULLET FEET ADJUSTABLE BULLET FEET ADJUSTABLE BULLET FEET SCALE: 3/4" = 1'-0" 3' - 1" 3/4" = 1'-0" STAINLESS STEEL DRAWER WITH LOCKS TYP. STAINLESS DETAIL 'A' 4 SCALE: 9' - 1" 3 A1.02 Sim 5 A1.02 Sim 3/4" = 1'-0" B) Pulls: Door and drawer front pulls are epoxy powder coated metal wire with 96mm spacing on screws. Pull design shall comply with the Americans with Disabilities Act (ADA). Door and drawer front pulls shall be rectangular semi-recessed, injection molded ABS plastic, screw fastened. Pull design shall be compatible with Americans with Disability Act (ADA), Federal Register Volume 56, No. 144, specifically paragraph 4.27.4. Other pulls may be acceptable pending architect approval. 3 12' - 2" 3 A1.02 Sim 4 A1.02 Sim 3 A1.02 Sim 5 A1.02 Sim 4 A1.02 C) Drawer Slides: Regular use and kneespace drawers are epoxy powder coated steel, bottom corner mounted with nylon rollers. Slides have a 100-pound load rating at full extension and a built-in, positive stop both directions, with self-closing feature. File drawer slides are full extension, epoxy powder coated steel, bottom corner mounted with nylon rollers, 150-pound load rating. Pencil drawers are equipped with Blum No. BS230M, zinc color. Slides have a lifetime warranty as offered by the slide manufacturer. D) Adjustable Shelf Supports: Injection molded polycarbonate, clear color to blend with selected interior finish, friction fit into cabinet end panels and vertical dividers, readily adjustable on 32mm (approximately 1-1/4") centers. Each shelf support has two (2) integral support pins, 5mm diameter, to interface pre-drilled holes, and to prevent accidental rotation of support. The supports automatically adapt to 3/4" or 1" thick shelving and provide nontip feature for shelving. Supports are designed to readily permit field fixing of shelf if desired. Structural load testing shall show loading to 1,140 pounds (285 pounds per support) without failure. Sim E) Locks: National Lock #M4-9054B, removable core, disc tumbler, cam style lock with strike. Each lock is furnished with two (2) keys. Lock for sliding 3/4" doors is a disc type plunger lock, sliding door type with strike. F) Finished stainless steel face panel and front base sealed to floor G) Stainless steel removable base plate attached to feet at back of counter as per details. 3' - 0" Sim SCALE: 2' - 6" 3' - 0" S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt 2/12/2016 4:11:13 PM STAINLESS STEEL UNDER SHELF WITH 3/4" COVE CORNERS TYP. STAINLESS DETAIL 'B' Accessories: A) Hinges: Five knuckle, institutional grade, 2-3/4" overlay type with hospital tip. Steel is minimum .095" thick and have a minimum of nine (9) edge and leaf fastenings and are epoxy powder coated “chrome” color to match Owner’s standard requirements. Hinges pass ANSI-BHMA standard A156.9, Grade 1 requirement for both vertical and horizontal set and sag (pair of hinges will hold minimum of 310 pounds); copy of test result provided upon request. Hinges are secured with specifically engineered screws. Doors 48" and over in height have three (3) hinges per door. Magnetic door catch with minimum five (5) pound pull provided, attached with screws and slotted for adjustment. STAINLESS STEEL DRAWER WITH LOCKS STAINLESS STEEL CABINET DOOR WITH LOCKS STAINLESS STEEL UNDER SHELF WITH 3/4" COVE CORNERS AND TURN DOWN EDGE 5 Edging Materials: 1.) 3mm PVC banding, machine applied with waterproof hot melt adhesive with external edges and outside corners of door and drawer fronts, and countertops, machine profiled to 1/8" radius for safety. PVC edge banding to match laminate color selected by Architect. 2" TURNED DOWN STAINLESS STEEL EDGE. 1" X 4" STAINLESS STEEL BRACING (TYP) STAINLESS STEEL UNDER SHELF WITH 3/4" COVE CORNERS AND TURN DOWN EDGE TYP. STAINLESS DETAIL 'C' 6 STAINLESS STEEL TOP WITH 3/4" RADIUS COVED CORNERS. Sim STAINLESS STEEL DRAWER WITH LOCKS 4 A1.02 3" = 1'-0" SCALE: Laminate Color Selection: 1.) Color selection for high pressure decorative laminate to be from manufacturers= full range of colors/price groups. 2.) Selections for cabinet surfaces, grade VGS, are offered from the current year Wilsonart, Formica, or Pionite Series. A maximum of one (1) color to be selected per unit face and five (5) colors per project. 3.) Selections for countertop grades, HGS, shall be selected from the current year Wilsonart, Formica, or Pionite standard and premium solid and pattern offering. A maximum of five (5) colors per project. 4.) Basic cabinet body color to include surfaces of all components, including drawer boxes, to be covered with melamine laminate as a minimum requirement; drawer boxes not matching basic color will be rejected. DATE PROJECT NO. DATE 12723 PARK AVENUE RIVERTON, UTAH 84065 STAINLESS STEEL TOP JORDAN SCHOOL DISTRICT REMOVE EXISTING END WALL GLAZING PANEL FOR EVAPORATIVE COOLER DUCTWORK, REPLACE WITH METAL INSULATED SOLID PANEL AS NEEDED WITH DUCTWORK OPENING, PAINTED TO MATCH EXISTING J.A.T.C. SOUTH - GREENHOUSE UPGRADE REMOVE EXISTING SIDE WALL GLAZING PANELS FOR EXHAUST FAN, REPLACE WITH METAL INSULATED SOLID PANEL AS NEEDED WITH DUCTWORK OPENING, PAINTED TO MATCH EXISTING Core Materials: 1.) Particleboard: Medium density 45-50 pound industrial grade particleboard of fir or pine meeting or exceeding ANSI A 208.11993, M-3 requirements. Thickness' used are 1/4", 1/2", 3/4", and 1". 2.) Hardboard: Prefinished hardboard in 1/4" thickness meeting or exceeding commercial standards CS-251. REVISION/ISSUE SA-1527 FEBRUARY 2, 2016 KJM DRAWN BY CHECKED BY SES / CLL SHEET DESCRIPTION MISC. DETAILS Installation Instructions: A) Set and level as per plan. B) Clip and seal back splash to wall. BAE BID - STAINLESS 362929 ALT.#1 - D8920 - D3300 BASE BID - STAINLESS 363529 BASE BID - STAINLESS 363529 BASE BID - STAINLESS 363529 ALT.#1 - B1060 ALT.#1 - B1060 ALT.#1 - D8920 - D3300 BASE BID - STAINLESS 363529 BASE BID - STAINLESS 363529 BASE BID - STAINLESS 363529 BID ALTERNATES #1 TYPICAL ADA STUDENT WORK AREA SCALE: BASE BID - STAINLESS 363529 3/4" = 1'-0" 2 TYPICAL STUDENT WORK AREA SCALE: 3/4" = 1'-0" 1 PROVIDE BID ALTERNATE FOR STUDENT WORK AREAS TO BE CONSTRUCTED WITH STAINLESS STEEL WORKTOPS AND PLASTIC LAMINATE FACES BASED ON TMI SYSTEMS. SEE SPECIFICATION LEGEND. SHEET NUMBER A1.02 GENERAL NOTES EXISTING 6" METAL STUDS (VIF) 6" CFMF R-19 BATT INSULATION 12" MIN. 5/8" EXT. SHEATHING FLASHING MEMBRANE (12'' MIN. HEIGHT) 1" RIGID INSULATION W/ BACKING THERMOPLASTIC ROOF MEMBRANE THERMAL INSULATION 12" MIN. ABSOLUTELY ALL MECHANICAL UNITS SHALL BE MOUNTED ON TOP OF A INSULATED CURB. SLEEPER INSTALLATION WILL NOT BE ALLOWED. SEE MECHANICAL C. (2) C6 x 1 5/8 16 GAGE UP TO 6' FASTENER D. HOT AIR WELD 6" B. A EXTEND SINGLE PLY ROOFING UP TO CURB FLASHING FASTENER ALL MECHANICAL UNITS AND OTHER ROOF PENETRATIONS MAY NOT BE SHOWN. REFER TO MECHANICAL AND PLUMBING SHEETS. PROVIDE FLASHINGS, CRICKETS, AND REGLETS AT EACH UNIT, SHOWN OR NOT. VERIFY EACH LOCATION ON MECHANICAL AND PLUMBING SHEETS. EXISTING 6" METAL STUDS (VIF) FLASHING MEMBRANE CAP A. EXISTING ROOFING 1 1/2" 1 1/2" 2-TRACKS 6x1 1/2x16 GAGE TRACK ROOF DECK PLUMBING VENT STACK A SECTION NOTES: VENT STACKS AND OTHER PIPES SHOULD HAVE A MINIMUM OF 12 IN.OF CLEARANCE ON ALL SIDES FROM WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITAE PROPER FLASHING. OPENING THRU WALL TYP. PIPE PENETRATION DETAIL SCALE: 1 1/2" = 1'-0" TYP. CURB DETAIL 6 SCALE: 1 1/2" = 1'-0" 5 1/16" 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com ALL GENERAL ROOF SLOPES SHALL BE A MIN. OF 1/4" PER FT. ALL MANUFACTURED & INSTALLED TAPERS & OR CRICKETED AREAS SHALL HAVE A POSITIVE SLOPE TO DRAINS & AWAY FROM ADJACENT WALLS AS REQ'D. E. ALL PARAPETS, CURBS FOR ARCHITECTURAL, MECHANICAL & ELECTRICAL SHALL BE MIN. OF 12" ABOVE HIGHEST ADJACENT ROOF & OR CRICKET, W/ NONCOMBUSTABLE CANT STRIPS INSTALLED AT THE BASE UNDERNEATH ROOF MEMBRANE. F. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY ALL DECK BEARING TO PARAPETS HEIGHTS PRIOR TO INSTALLATION. G. SEE DETAILS A2.01 FOR PIPE PENETRATION DETAILS. REFER TO MECHANICAL SHEETS FOR LOCATIONS. H. SEE DETAIL A2.01 FOR MECHANICAL UNIT W/ CURB DETAIL. SHEET NOTES 2-SCREWS (TYP.) 1 1/2" @ 16" CUT OFF ALL ROOFING INSULATION ANCHORS TO WITHIN 2" OF ROOF DECK IN ALL AREAS WHERE THE STRUCTURE IS TO BE EXPOSED. 1 2 NEW ROOF TOP EXHAUST FAN ON CURBS. SEE TYPICAL DECK PENETRATION DETAIL (2/A2.01). SEE MECHAINCAL SHEETS. EXISTING SINGLE PLY ROOFING. WATER CUT-OFF MASTIC STAINLESS STEEL CLAMPING RING PRE-MOLDED PIPE FLASHING FASTENER 1 1/2" THERMAL INSULATION MIN B ELEVATION TYP. WALL PENETRATION DETAIL SCALE: 3/4" = 1'-0" 3 CONTRACTOR TO VERIFY THAT HSS6x6x3/8 HAVE BEEN WELDED TO BOTT. OF EXISTING JOISTS AND DIAG <'S ARE INSTALLED ROOF DECK PLUMBING VENT STACK TYP. PIPE FLASHING DETAIL S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt SCALE: 1 1/2" = 1'-0" 4 FRAME OPENINGS WITH <3x3x1/4 EXIST 30K12 JOISTS @ 5'-0" O.C. (VIF) E <5x3x1/4 2 CURB OF MECHANICAL UNIT WITH 1,400# MAX COPE L5x3 OR 3x3 TO FIT INTO TOP CHORD ANGLES TYPICAL NOTE: AT <5x3 SUPPORT BY JOIST WELD OPENING THRU DECK D <5x3x1/4 UNDER PERIMETER OF MECHANICAL UNIT 3/16" OPENING 3/16" 1 2 A2.01 D PLAN DETAIL 3 A2.01 CURB OF MECHANICAL UNIT WITH 1,400# MAX COPE L5x3 OR 3x3 TO FIT INTO TOP CHORD ANGLES TYPICAL Sim DATE C 12723 PARK AVENUE RIVERTON, UTAH 84065 ADD 3-C6x1 5/8x16 GAGE STUDS FRO NEW JAMB EACH SIDE THERMOPLASTIC ROOF MEMBRANE JORDAN SCHOOL DISTRICT HOT AIR WELD J.A.T.C. SOUTH - GREENHOUSE UPGRADE NEW TRACK 14 GAGEx6 WTIH 3" LEGS REVISION/ISSUE Sim EXISTING 1 1/2" DECK 3/16" PROJECT NO. DATE SA-1527 FEBRUARY 2, 2016 KJM DRAWN BY D IF 4" OR MORE THEN WELD <2x2x1/8 TO NEAREST BOTT. CHORD PANEL POINT CHECKED BY SES / CLL SHEET DESCRIPTION ROOF PLAN E 2/12/2016 4:11:14 PM SHEET NUMBER north TYP. DECK PENETRATION SCALE: 3/4" = 1'-0" 2 ROOF PLAN SCALE: 1/8" = 1'-0" 1 A2.01 MECHANICAL LEGEND GENERAL NOTES (FOR ALL MECHANICAL DRAWINGS) PLUMBING DOMESTIC COLD WATER HWR HEATING WATER RETURN DOMESTIC HOT WATER VALVES & SPECIALTIES 180 NP STRAINER W/ BLOW-OFF VALVE & HOSE END CONSULTING ENGINEERS, INC. NG NATURAL GAS V PLUMBING VENT PIPE CHV CHEMICAL VENT PIPE SAN SANITARY WASTE PIPE HORIZONTAL CLEANOUT TEMPERATURE CONTROL VALVE, 2-WAY 500 West 18th Street, Suite 200 Cheyenne, WY 82001-4368 307.634.7647 VERTICAL CLEANOUT SOLENOID VALVE THE INSTALLATION OR REMOVAL OF DUCTS, PIPES AND EQUIPMENT MAY REQUIRE THE REMOVAL OF EXISTING WALLS AND CEILINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING THESE WALLS AND/OR CEILINGS SO THEY MATCH THE EXISTING WHERE NOT REPLACED UNDER ARCHITECTURAL DIVISION. 3. ALL FIXTURES AND EQUIPMENT REMOVED, AND NOT REUSED, ARE TO BE RETURNED TO OWNER. Mechanical, Electrical & Energy Consultants 7600 East Orchard Road, Suite 250-S Greenwood Village, CO 80111-2518 303.796.6000 www.mkkeng.com HVAC DUCTWORK 4. PATCH OPENINGS (AIR TIGHT) IN DUCTS WHICH ARE TO REMAIN ACTIVE AND HAVE HAD A SECTION REMOVED. ALSO REPAIR DUCT INSULATION SO THAT IT IS CONTINUOUS. 5. INFORMATION ON THE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF THE REMODEL WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY CONTRACT DOCUMENTS. 6. CONTRACTOR TO SEAL ALL AUDIBLE AND VISIBLE LEAKS ON ALL REUSED SUPPLY DUCTWORK. 7. CONTRACTOR IS TO PROVIDE COMPLETE CONNECTIONS TO ALL NEW AND RELOCATED OWNER FURNISHED EQUIPMENT. 8. ALL PIPING AND DUCTS INDICATED TO BE REMOVED UNDER THIS CONTRACT SHALL BE REMOVED COMPLETELY TO POINTS OF CONNECTION AT THE MAINS OR BRANCHES AND CAPPED. 9. WORK UNDER THIS CONTRACT IS IN OCCUPIED SPACES, STORAGE ROOMS AND EQUIPMENT ROOMS. CONTRACTOR IS TO SCHEDULE AND COORDINATE THE WORK AND ANY EXISTING EQUIPMENT DOWNTIME WITH THE OWNER OR PROPERTY MANAGER PRIOR TO BEGINNING WORK. 175 North 27th Street, Suite 1312 Billings, MT 59101-2048 406.256.1141 MANUAL AIR VENT FIRE DAMPER AUTOMATIC AIR VENT S SMOKE DAMPER PRESSURE - TEMP. TAP FS COMBINATION FIRE / SMOKE DAMPER CONTROLS LEGEND (SYMBOLS LOCATED IN TC SCHEMATICS) DP FLOW PRESSURE GAUGE W/ PIG TAIL & COCK REF TURNING VANES SHOWN IN 90° ELBOW. REFRIGERENT DETECTOR CONTROL WIRING THERMOMETER HI CONTROL AIR PIPING PIPE EXPANSION JOINT TEMPERATURE CONTROL DAMPER (T.C.) OPPOSED BLADE DAMPER ( O.B.D. ) FLEXIBLE PIPE CONNECTOR (STAINLESS STEEL BRAIDED) M FLEXIBLE EQUIPMENT CONNECTOR (RUBBER DOUBLE BELLOWS) 24/12 PIPE UNION MAIN AIR DUCT SIZES ARE OUTSIDE SHEET METAL DIMENSIONS. 1st NO. IS SIZE OF SURFACE SHOWN. 2nd NO. IS DUCT DEPTH. LETTERS AFTER DIM. CORRESPOND TO FOLLOWING: ANALOG INPUT OR OUTPUT SYMBOL FLOW T AIR FLOW MEASURING STATION H HUMIDISTAT/HUMIDITY SENSOR ICE SNOW/ICE SENSOR CO CARBON MONOXIDE SENSOR CO2 CARBON DIOXIDE SENSOR NO2 NITROGEN DIOXIDE SENSOR FILTER COIL C SECTION THRU OUTSIDE AIR INTAKE OR SUPPLY AIR DUCT SECTION THRU RETURN AIR OR EXHAUST DUCT T VARIABLE FREQUENCY DRIVE SUPPLY AIR DUCT DOWN BFV 3-WAY BUTTERFLY VALVE FLEXIBLE CONNECTION M END SWITCH 12. CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING BID, AND VERIFY DIMENSIONS AND EXISTING CONDITIONS RELATED TO THE WORK. SWITCH 13. ALL EXISTING EQUIPMENT AND MATERIALS CALLED TO BE REMOVED UNDER THIS CONTRACT SHALL BE REMOVED FROM OCCUPIED SPACES DAILY. FLOW SWITCH HAND HELD OPERATORS TERMINAL LAP TOP WORK STATION DUCT AVERAGING TEMPERATURE SENSOR 2-WAY BUTTERFLY VALVE M S EMERGENCY PULL SWITCH BINARY INPUT OR OUTPUT SYMBOL MOD LU PS MODULATING 3-WAY & 2-WAY VALVES HI MODEM LO PRINTER 2P FLEXIBLE DUCT 2P F D HI 2 POSITION 3-WAY & 2-WAY VALVES DUCT SMOKE DETECTOR LO DSP DUCT STATIC PRESSURE SENSOR BSD BUILDING STATIC PRESSURE SENSOR LO LT 14. ALL CUTTING, PATCHING AND CORE DRILLING FOR THE INSTALLATION OF NEW EQUIPMENT, DUCTS, HANGERS, ETC. SHALL BE HELD TO A MINIMUM AND BE ACCOMPLISHED IN A CAREFUL MANNER. ALL PATCHING SHALL MATCH EXISTING CONSTRUCTION, TEXTURE AND FINISH AND BE DONE BY SKILLED CRAFTSMAN OF THE TRADES INVOLVED AT THE CONTRACTOR'S EXPENSE. 15. CONTRACTOR TO COORDINATE THE LOCATION OF ALL DUCTWORK, CEILING DEVICES, GRILLES, REGISTERS AND DIFFUSERS WITH REFLECTED CEILING PLAN AND STRUCTURE PRIOR TO BEGINNING WORK. 16. DUCT DIMENSIONS GIVEN ARE OUTSIDE SHEET METAL DIMENSIONS. 17. MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY INDICATE EVERY REQUIRED OFFSET, FITTING, ETC. DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK, VERIFY ALL SPACE REQUIREMENTS COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE SPACE PROVIDED WITHOUT EXTRA CHARGES TO THE OWNER. 18. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR TO MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO PERFORM HIS WORK. WATER DIFFERENTIAL PRESSURE SENSOR/CONTROLLED CPU 19. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE CODES, LOCAL CODES AND OWNER'S STANDARDS INDICATED BY THE CONSTRUCTION DOCUMENTS. MONITOR 20. ALL EXTERIOR WALL AND ROOF PENETRATIONS SHALL BE SEALED WATERPROOF. COMPUTER UNIT 21. XX-## REFERS TO EQUIPMENT DESIGNATION. SEE SPECIFICATIONS AND EQUIPMENT SCHEDULES FOR FURTHER INFORMATION IN REFERENCE TO THAT DESIGNATED PIECE OF EQUIPMENT. HI LOW TEMPERATURE DETECTION THERMOSTAT T 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com CONSULTING ENGINEERS, INC. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com 10. CONTRACTOR SHALL MAKE ARRANGEMENTS FOR PARKING, COORDINATE ANY EQUIPMENT DOWNTIME, AND COORDINATE GENERAL WORK SCHEDULE WITH THE PROPERTY MANAGER. 11. THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF THE EXISTING EQUIPMENT LOCATIONS, EXISTING PIPE ROUTING AND EXISTING DUCT ROUTING. CONTRACTOR IS TO INSTALL NEW EQUIPMENT, DUCTS, AND PIPING IN LOCATIONS REQUIRED TO AVOID INTERFERENCE WITH EXISTING FACILITIES, EQUIPMENT, DUCTS AND PIPING. CONTRACTOR IS RESPONSIBLE FOR RAISING AND LOWERING EXISTING EQUIPMENT AND MAKING PROPER OFFSETS IN DUCTS AND PIPING TO AVOID CONFLICTS. T BFV BACKDRAFT DAMPER ES ROOM THERMOSTAT/TEMP SENSOR SUBSCRIPTS: S - W/STAINLESS STEEL COVER A - W/SETPOINT ADJUSTMENT I - W/TEMP INDICATION AI - W/TEMP AND ADJUSTMENT G - W/LOCKING GUARD N - NIGHT OA, RA OR EXH DUCT DOWN CHANGE OF ELEVATION UP (UP) DOWN (DN) IN DIRECTION OF AIR FLOW EMER FS MOTOR STARTER VFD XXX XXX REMOTE BULB SENSOR/CONTROLLER RETURN/TRANSFER/EXHAUST AIR TAG. SEE SCHEDULE FOR TYPE. RETURN AIR GRILLE W/SOUND BOOT SHADING INDICATES OPEN END XXX XXX FAN SUPPLY DIFFUSER. ALL DIFFUSERS FOUR-WAY THROW UNLESS NOTED OR THROWS SHOW IN PLAN. SEE SCHEDULE FOR TYPE. S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt CURRENT TRANSFORMER GAUGE PUMP Ø - ROUND DUCTWORK D - DOUBLE WALL CONSTRUCTION UL - UNLINED DUCTWORK V - OVAL DUCTWORK UP LOW CT DAMPER ACTUATOR PIPE CAP DIFFERENTIAL PRESSURE SENSOR ON DEMOLITION PLANS EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN HEAVY LINE WEIGHT, EXISTING MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS NEW MECHANICAL SYSTEMS ARE SHOWN HEAVY LINE WEIGHT. 2. 50 years and counting! NON-POTABLE WATER CHECK VALVE BALL VALVE DOMESTIC HOT WATER ( TEMP. SHOWN ) DOMESTIC HOT WATER CIRCULATING SHUT-OFF VALVE CALIBRATED BALANCING SHUT-OFF VALVE. 1. WATER TEMPERATURE SENSOR WITH WELL ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 HEATING WATER SUPPLY JORDAN TECHNICAL HWS SA-1527 JORDAN TECHNICAL CENTER PIPING ABBREVIATIONS AFF AFG ALT BHP BTU C CFM SCFM CU FT CU IN Cv dB DB DCW DEG OR ° DHW DIA DN (E) EAT EFF ELEV ESP EWT EXH F ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ALTITUDE BRAKE HORSEPOWER BRITISH THERMAL UNIT COMMON PORT CUBIC FEET PER MINUTE CFM, STANDARD CONDITIONS CUBIC FEET CUBIC INCH COEFFICIENT, VALVE FLOW DECIBEL DRY BULB DOMESTIC COLD WATER DEGREE DOMESTIC HOT WATER DIAMETER DOWN EXISTING ENTERING AIR TEMP. EFFICIENCY ELEVATION EXTERNAL STATIC PRESSURE ENTERING WATER TEMP. EXHAUST FAHRENHEIT FLA FPM FPS FT FU GA GAL GPH GPM HD HG HGT HORZ HP HR HWC HZ ID IE IJS IN IN W.C. KW KWH LAT LBS OR # FULL LOAD AMPS FEET PER MINUTE FEET PER SECOND FOOT, FEET, FEET WATER COLUMN FIXTURE UNITS GAUGE GALLONS GALLONS PER HOUR GALLONS PER MINUTE HEAD MERCURY HEIGHT HORIZONTAL HORSEPOWER HOUR(S) HOT WATER CIRCULATING (DOMESTIC) HERTZ INSIDE DIAMETER INVERT ELEVATION IN JOIST SPACE INCHES INCHES IN INCHES WATER COLUMN KILOWATT KILOWATT HOUR LEAVING AIR TEMPERATURE POUNDS LF LRA LWT MAX MBH MCA MIN N/A N.C. N.O. NC NIC NO OR # NTS OA OD % PH OR Ø PPM PRESS PSF PSI PSIA PSIG RA RECIRC LINEAR FEET LOCKED ROTOR AMPS LEAVING WATER TEMPERATURE MAXIMUM BTU PER HOUR (THOUSAND) MINIMUM CIRCUIT AMPS MINIMUM NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN NOISE CRITERIA NOT IN CONTRACT NUMBER NOT TO SCALE OUTSIDE AIR OUTSIDE DIAMETER PERCENT PHASE (ELECTRICAL) PARTS PER MILLION PRESSURE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PSI ABSOLUTE PSI GAUGE RETURN AIR RECIRCULATE RH RLA RPM SA SENS SL SP SPEC SQ STD TD TEMP THRU TJO TONS TSP TSTAT TYP V VAV VEL VERT VOL W WB WPD WT RELATIVE HUMIDITY RUNNING LOAD AMPS REVOLUTIONS PER MINUTE SUPPLY AIR SENSIBLE SEA LEVEL STATIC PRESSURE SPECIFICATION SQUARE STANDARD TEMPERATURE DIFFERENCE TEMPERATURE THROUGH THROUGH JOIST OPENINGS TONS OF REFRIGERATION TOTAL STATIC PRESSURE THERMOSTAT TYPICAL VOLT VARIABLE AIR VOLUME VELOCITY VERTICAL VOLUME WATT WET-BULB WATER PRESSURE DROP WEIGHT DATE PROJECT NO. DATE REVISION/ISSUE SA-1227 FEBRUARY 2 2016 DRAWN BY --- CHECKED BY --- SHEET DESCRIPTION MECHANICAL COVER SHEET 11/9/2015 4:39:56 PM SHEET NUMBER M0.00 FLAG NOTES (THIS SHEET): 1. EXISTING TRENCH DRAIN TO REMAIN. POWER WASH INSIDE OF TRENCH DRAINS. AUGER WASTE LINES DOWNSTREAM EXISTING WASTE PIPING LOCATED IN SLAB FROM ALL TRENCH DRAINS. 2. EXISTING SOIL INTERCEPTOR TO REMAIN. CONTRACTOR SHALL CLEAN INTERCEPTOR AND AUGER WASTE LINES DOWN STREAM OF INTERCEPTOR. 3. EXISTING HOT WATER UNIT HEATER TO BE REMOVED. MAINTAIN EXISTING HEATING WATER MAINS AND BRANCHES. 4. EXISTING BOILER TO REMAIN. 5. EXISTING WATER HEAT TO REMAIN. 6. EXISTING EXHAUST FAN TO BE REMOVED. 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com CONSULTING ENGINEERS, INC. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com 1-1/4" 3/4" 1-1/2" 2" 1/2" 1-1/2" 4 B-1 2" 1-1/4" P-1 5 WH-1 1" FS-1 UH-6 3 3 UH-1 TD-1 3" 1 2" 3" 1 SAN 2 3 UH-2 UH-5 1-1/2" 1-1/2" SAN TD-1 3" HWS HWR 1 HWS HWR S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt 3 DATE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 2" TD-1 JORDAN TECHNICAL SA-1527 JORDAN TECHNICAL CENTER HWS HWR SAN HWS HWR 1-1/2" REVISION/ISSUE 3" PROJECT NO. TD-1 DATE UH-4 UH-3 6 3 SA-1227 1 6 3 FEBRUARY 2 2016 DRAWN BY --- CHECKED BY --- SHEET DESCRIPTION MECHANICAL DEMO FLOOR PLAN 11/9/2015 4:39:56 PM SHEET NUMBER NORTH MECHANICAL DEMO FLOOR PLAN SCALE: 3/32" = 1' 1 M1.01 FLAG NOTES (THIS SHEET): 1. EXISTING BOILER TO REMAIN. 2. EXISTING WATER HEATER TO REMAIN. 3. UH-#, NEW HOT WATER UNIT HEATER, SEE SCHEDULE FOR CAPACITIES AND PIPING DETAIL FOR CONNECTION REQUIREMENTS. MOUNT UNIT HEATER WITH BOTTOM AT ± 16'-0" A.F.F. CONTRACTOR SHALL COORDINATE EXACT HEIGHT WITH OWNER, ENGINEER AND ARCHITECT. 4. EC-#, NEW EVAPORATIVE COOLER, SEE SCHEDULE FOR CAPACITIES AND PIPING DETAIL FOR CONNECTION REQUIREMENTS. 5. EF-#, NEW EXHAUST FAN, SEE SCHEDULE FOR CAPACITIES AND DETAIL FOR DUCTING REQUIREMENTS. 6. BFP-1, NEW REDUCED PRESSURE BACKFLOW PREVENTER FOR GREENHOUSE IRRIGATION. SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. ROUTE DRAIN TO FLOOR SINK. PROVIDE LINE SIZE PRV DOWN STREAM OF BFP-1, SET OUT LET PRESSURE AT 45 PSIG. TYPICAL. 7. ZV-#, IRRIGATION ZONE VALVE, SEE PLAN FOR ZONE NUMBER AND ZONE VALVE SCHEDULE FOR ADDITIONAL INFORMATION. TYPICAL 6 BFP-1 8. HR-1, HOSE REEL, SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. 2 WH-1 E1 15 72/48 9. S-1, SINK WITH SI-1, SOLIDS SEPARATOR, SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. NP 10. ROUTE 3/4” NP WATER LINE DOWN IN CORNER OF GREENHOUSE, PENETRATE EXTERIOR WALL, ROUTE OUTSIDE AND CONNECT TO EACH EC. 1-1/4" 3/4" 1-1/2" 2" 1/2" 1-1/2" 1 B-1 16 2" 14 P-1 13 FS-1 1" NP 11 3/4" TO S-1 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com CONSULTING ENGINEERS, INC. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com 3" A S-1 EF-1 1" 1" 1" 11. EF'S VFD'S 5 12. EC'S VFD 1-1/2" 13. EXISTING GREENHOUSE CONTROL PANEL - SEE CONTROL SEQUENCE FOR WORK REQUIRED. 8 3 UH-2 2" 14. 44"Ø UP, SEE M2.02 FOR CONTINUATION. B B HR-1 UH-1 3 15. MOUNT BOTTOM OF GRILLE AT 14'-0" A.F.F. H H 3/4" HWS HWR NP SAN NP NP HWS HWR CF-1 CF-1 ZV-2A ZV-2B ZV-1A ZV-1B ZV-5B ZV-5A 16. RELOCATE EXISTING CONTROL CONDUITS TO ALLOW EXHAUST AIR GRILLE TO BE INSTALLED UNENCUMBERED HB-1 HB-1 ZV-3A ZV-3B 17. PROVIDE NETAFIM MODEL VN-BL SPRINKLER HEAD 3'-0" ON CENTER. MOUNT HEADS 3'-0" ABOVE TABLE TOP. TYPICAL. FROM ZONE VALVE TO HEAD USE NETAFIM 3/4" PE PIPING. PROVIDE CONTINUOUS SUPPORT FOR PIPING OVER TABLES. 18. FLOOR SINK FS-1. REFER TO SCHEDULE FOR MORE INFORMATION, CONTRACTOR SHALL INSTALL 2" AIR ADMITTANCE VALVE AAV-1, REFER TO SCHEDULE FOR MORE INFORMATION. 3" EE-1 TD-1 ZV-8B ZV-8A CF-1 8 B CF-1 ZV-6B ZV-6A HR-1 ZV-7B ZV-7A H B ZV-4B ZV-4A H KEEP TOP HORIZONTAL UNISTRUT AS ONE STRIP ACROSS ALL DUCTS HB-1 HB-1 60/86 GRILLE SAN 3 11/9/2015 4:39:56 PM UH-3 3 INSTALL UNISTRUT FRAME PER EC-# 28/37 GLASS 8 96" 36" H B CF-1 H 60" HR-1 CF-1 B BLOCK WALL HB-1 HB-1 1-1/2" 1-1/2" ZV-9B ZV-9A ZV-11B ZV-11A CF-1 CF-1 REVISION/ISSUE B HR-1 H B DATE 3 UH-6 8 UH-5 3 HWS HWR NP SAN SCALE: NO SCALE ZV-13B ZV-13A 3" NP HWS HWR SECTION A ZV-12B ZV-12A TD-1 NP 60" 4" CONCRETE PAD 7 ZV-10B ZV-10A H S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt UH-4 ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 9 TD-1 JORDAN TECHNICAL SI-1 SAN SA-1527 JORDAN TECHNICAL CENTER SAN HB-1 HB-1 CF-1 CF-1 PROJECT NO. 3" 18 TD-1 DATE SA-1227 FEBRUARY 2 2016 12 S1 21,670 12 S1 21,670 M S1 21,670 12 M NP D 10 M AAV-1 DRAWN BY --- CHECKED BY --- SHEET DESCRIPTION NEW MECHANICAL PLAN 28/37, (TYP.) EC-1 4 EC-2 4 EC-3 4 SHEET NUMBER A M2.01 NORTH MECHANICAL FLOOR PLAN SCALE: 3/32" = 1' 1 M2.01 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com FLAG NOTES (THIS SHEET): 1. 2. 44" DOWN THROUGH ROOF INTO MECHANICAL ROOM. FIELD ROUTE DUCT PENETRATION THROUGH ROOF TO PENETRATE BETWEEN AND CLEAR EXHAUST AND INTAKE STACKS FOR EXISTING BOILER. FIELD ROUTE TO PENETRATE WALL ABOVE HHW PIPING PENETRATION THROUGH WALL INTO GREENHOUSE. CONSULTING ENGINEERS, INC. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com 44"Ø 1 EF-2 EF-#, NEW EXHAUST FAN, SEE SCHEDULE FOR CAPACITIES AND DETAIL FOR DUCTING REQUIREMENTS. DATE PROJECT NO. DATE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 JORDAN TECHNICAL S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt SA-1527 JORDAN TECHNICAL CENTER 2 REVISION/ISSUE SA-1227 FEBRUARY 2 2016 DRAWN BY --- CHECKED BY --- SHEET DESCRIPTION MECHANICAL ROOF PLAN 11/9/2015 4:39:56 PM SHEET NUMBER NORTH MECHANICAL ROOF PLAN SCALE: 3/32" = 1' 1 M2.02 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com CONSULTING ENGINEERS, INC. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com 1-1/2" v 3/4" N O TI UA IN 01 NT 2. O M C E R SE FO (E LL N AI DR FI E LV VA D 1 SL O PE -2 SC NP NP SAN ID CH NO EN LE R )T SO SI- PE O SL D FS -1 N TIO A OL F S I F AL 0" A U OID N E, 6 N A E M LV OL S VA -1 Y V WA R P EE VE R L TH L VA FIL FS -1 1 NP SL -3 SC PE O FLAG NOTES (THIS SHEET): 1. CONNECT WASTE LINE DOWNSTREAM OF TRENCH DRAIN CONNECTION. S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt IDE S N I IDE S T OU NOTE: SUPPORT ALL PIPING INSIDE AND OUTSIDE FROM FLOOR AND HOUSEKEEPING PAD WITH UNISTRUT EVAPORATIVE COOLER ISOMETRIC S-1 AND SI-1 ISOMETRIC SCALE: N.T.S. SCALE: N.T.S. DATE PROJECT NO. DATE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 -1 1 S- -1 SC N IO UN SA SA-1527 JORDAN TECHNICAL CENTER N TIO A L ISO.) L UA, (TYP N MALVE VA E OP L S E OP L S .) P Y , (T JORDAN TECHNICAL NP REVISION/ISSUE SA-1227 FEBRUARY 2 2016 DRAWN BY --- CHECKED BY --- SHEET DESCRIPTION MECHANICAL ISOMETRICS 11/9/2015 4:39:56 PM SHEET NUMBER MECHANICAL ISOMETRICS SCALE: N.T.S. 1 M3.01 IRRIGATION VALVE SCHEDULE ITEM SERVICE VALVE SIZE CONNECTION MANUFACTURER & SIZE MODEL # IN. X IN. NOTES: GRILLES, REGISTERS, & DIFFUSERS SCHEDULE ZV-1A TABLE 1 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-1B TABLE1 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-2A TABLE 2 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-2B TABLE 2 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY S1 SUPPLY REGISTER 86/60 --- NO ZV3A TABLE 3 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY E1 SUPPLY REGISTER 72/48 --- NO ZV-3B TABLE 3 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-4A TABLE 4 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-4B TABLE 4 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-5A TABLE 5 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-5B TABLE 5 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-6A TABLE 6 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-6B TABLE 6 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY CONTROLS: ZV-7A TABLE 7 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY THE GREENHOUSE HAS BEEN PROVIDED WITH A LINK4 CUSTOM GREENHOUSE CONTROL SYSTEM. THE MODIFICATIONS AND ADDITIONAL MECHANICAL EQUIPMENT SHALL BE CONTROLLED FROM THIS PANEL EXCEPT AS NOTED BELOW. ZV-7B TABLE 7- FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-8A TABLE 8 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-8B TABLE 8 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZONE VALVES ZV-9A TABLE 9 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-9B TABLE 9 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-10A TABLE 10 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-10B TABLE 10 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-11A TABLE 11 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-11B TABLE 11 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY CONNECT ALL NEW ZONE VALVES TO EXISTING LINK4 CONTROLLER. UNIT HEATER: UTILIZE EXISTING CONTROLS FOR EACH UNIT HEATER; RELOCATE EXISTING CONTROL CONNECTION TO NEW CONNECTIONS FOR EACH UNIT HEATER. EQUIP TAG TYPE FACE SIZE IN. MOUNTING TYPE DAMPER MATERIAL REQUIRED MANUFACTURER & MODEL PLAN INFO XXXX XXXX SPECIFIC NOTES ALUM KRUEGER AF880 NECK / CFM ALUM KRUEGER AF880 NECK / CFM 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com UNIT HEATER SCHEDULE ITEM TYPE CFM MBH HEATING WATER % EWT LWT GPM °F °F GLY AIR WPD EAT FT F LAT F MOTOR DATA HP V-PH PIPE SIZE IN MANUFACTURER & MODEL # NOTES CONTROLS CONSULTING ENGINEERS, INC. UH-1 VERT 2220 97.0 180 160 0 9.7 0.8 50 100 1/6 115/1 1-1/4 TRANE P146 IRRIGATION SYSTEM UH-2 VERT 2220 97.0 180 160 0 9.7 0.8 50 100 1/6 115/1 1-1/4 TRANE P146 IRRIGATION SYSTEM UH-3 VERT 2220 97.0 180 160 0 9.7 0.8 50 100 1/6 115/1 1-1/4 TRANE P146 IRRIGATION SYSTEM UH-4 VERT 3200 133.0 180 160 0 13.3 1.3 50 100 1/4 115/1 1-1/4 TRANE P202 IRRIGATION SYSTEM UH-5 VERT 3200 133.0 180 160 0 13.3 1.3 50 100 1/4 115/1 1-1/4 TRANE P202 IRRIGATION SYSTEM UH-6 VERT 3200 133.0 180 160 0 13.3 1.3 50 100 1/4 115/1 1-1/4 TRANE P202 IRRIGATION SYSTEM 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com NOTES: EVAPORATIVE COOLER SCHEDULE 1/29/2016 ZV-12A TABLE 12 -SPRAY 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE ITEM 2-WAY ZV-12B TABLE 12 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-13A TABLE 13 -SPRAY 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY ZV-13B TABLE 13 - FUTURE DRIP 3/4 3/4 X 3/4 NETAFIM SERIES 80 CONTROL VALVE 2-WAY SERVICE CFM CONTROL VALVE. SUPPLY AIR FAN DATA FAN ESP RPM MOTOR DATA TYPE IN. WC HP V-PH STRTR @ ALT MAX VEL FPM DIRECT EVAPORATIVE COOLER DATA SENS. EAT LAT GPH MAX dP CAP °F °F AIR MBH DB/WB DB/WB IN OP WGT LBS MANUFACTURER & MODEL NO. NOTES EC-1 GREENHOUSE 21670 CENT 0.1 380 7.5 460-3 VFD 500 462 97.7/62.8 69/62 55 0.05 1400 ESSIC AS20012B/20012W EC-2 GREENHOUSE 21670 CENT 0.1 380 7.5 460-3 VFD 500 462 97.7/62.8 69/62 55 0.05 1400 ESSIC AS20012B/20012W EC-3 GREENHOUSE 21670 CENT 0.1 380 7.5 460-3 VFD 500 462 97.7/62.8 69/62 55 0.05 1400 ESSIC AS20012B/20012W CONTROLS NOTES: ~ ~ RETURN SUPPLY FAN SCHEDULE 1/29/2016 ITEM TYPE AREA SERVED EXHAUST FANS: EXISTING EXHAUST FANS ARE BEING REMOVED; NEW EXHAUST FANS ARE BEING LOCATED ON THE OPPOSITE END OF THE GREEN HOUSE. CONTROL OF EXHAUST FANS SHALL BE FROM THE SAME CONTROLLER AS THE EVAPORATIVE COOLERS. EXHAUST FAN MODULATION SHALL BE IN RESPONSE TO EVAPORATIVE COOLER FAN MODULATION, THE SPACE SHALL BE MAINTAINED AT A 0.03” WG NEGATIVE WITH RESPECT TO THE OUTDOORS. NEITHER FAN SHALL BE ALLOWED TO OPERATE AT LESS THAN 20% FLOW (HERTZ). UNIT HEATER PIPING DETAIL CFM FAN RPM ESP INWC DRIVE TYPE dBA/ SONES BHP MOTOR DATA H.P. RPM V-PH MANUFACTURER & MODEL NO. NOTES STRTR OP WT LBS EF-1 UTILITY SET GREENHOUSE 17000 1119 0.25 BELT 79.0 7.9 10 1750 460-3 VFD 67 COOK CPS-300 1 EF-2 WALL PROPELLER GREENHOUSE 45000 500 0.25 BELT 52.0 5.3 7 1/2 1750 460-3 VFD 904 COOK 60XMWH 2 CF-1 CAGED PROPPELLER GREENHOUSE 6000 800 0 DIRECT 66 - 1/4 800 115-1 MAN 53 COOK CAC-ACH CONTROLS NOTES: 1. ROOF CURB, BACKDRAFT DAMPER, BIRDSCREEN, AND DISCONNECT SWITCH. NO SCALE 2. INLET GUARD, MOTORIZED DAMPER, BIRDSCREEN, AND DISCONNECT SWITCH. PLUMBING FIXTURE AND EQUIPMENT SCHEDULE PLAN FIXTURE CODE ICC/ANSI A117.1 MANUFACTURER SERIES TRIM SERIES SUPPLIES AIR ADMITTANCE VALVE --- DRAIN CW WASTE COMPLIANT # AAV-1 TRAP / STUDOR MINI-VENT HW / WASTE VENT TEPID WATER NOTES / REMARKS CONSUMPTION --- --- --- --- --- --- --- --- 2" --- PROVIDE VENTED WALL BOX --- --- INTEGRAL --- --- SEE --- --- --- --- W/MANUFACTURER'S MATCHING S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt MAXI-VENT BFP-1 REDUCED PRESSURE --- FEBCO PRIN. BACKFLOW PREVENTOR EE-1 EMERGENCY EYE 860 / 860U 1/2" - 2" --- GUARDIAN G1825 PLANS --- --- WASH, PEDESTAL MOUNTED EE-MV-1 EYE WASH FLOOR SINK HOSE BIBB HB-2 P-TRAP INTEGRAL --- 3/4" 2" 1 1/2" --- PROVIDE W/EE-MV-1 --- --- 3/4" 3/4" --- --- --- ANSI Z358.1-2004 COMPLIANT P-TRAP INTEGRAL --- --- 3" 2" --- FULL , 1/2 GRATE VALVE --- GUARDIAN G3600 --- --- MIXING VALVE FS-1 W/ISO. AIR GAP DRAIN W/ISO. VALVE --- --- J.R. SMITH 3060 JOSAM 49520A-NB CHICAGO 952-CP --- --- --- ROUND, MEDIUM DUTY --- --- FAUCET W/ISO. --- --- 3/4" --- --- --- --- 1, CHROME PLATED VALVE HR-1 HOSE REEL --- HANNAY FN716-19-20J --- --- --- --- --- 3/4" --- --- --- --- PROVIDE 50 FT, 1/2" HOSE PRV-1 WATER PRESSURE --- WATTS 223 --- --- W/ISO. --- --- SEE --- --- --- --- 1, W/STRAINER, PRESSURE REDUCING VALVE SI-1 SOLIDS INTERCEPTOR S-1 SS SCULLERY SINK VALVE --- --- FM SA-1 SHOCK ABSORBER --- J.R. SMITH 8714 JUST SB-260-24LR W/ 2 J-35 BLA STOPS 12" DEPTH JOSAM 75000 --- --- W4W-L9E1-369AB-317-PR CHICAGO --- W/STOPS 613-A ADAPTA FACUET SPRAYER CHROME --- --- (WTR-HAMMER ARRESTERS) LEGEND: PLANS --- CP. --- --- --- SEE SEE PLANS PLANS --- LK35 1/2" 1/2" 2" 1 1/2" 1.5 GPM 2, 2 FAUCETS; 2 SETS OF SUPPLIES; PUNCH HOLES TO MATCH FAUCET --- SEE SEE --- --- --- 1 PLANS PLANS CH = CHILD HEIGHT, CM = CEILING MOUNTED, CP = CHROME PLATED, CT = COUNTERTOP, FM = FLOOR MOUNTED, FV = FLUSH VALVE, PA = PRESSURE ASSIST, SS = STAINLESS STEEL, TP = PROVIDE TRAP PRIMER (TP-1) ADJACENT TO FIXTURE, WM = WALL MOUNTED (PROVIDE WITH A FLOOR MOUNTED CONCEALED CARRIER), UCT = UNDER COUNTERTOP PROJECT NO. DATE GENERAL NOTES: 1. WHERE FIXTURE/EQUIPMENT MODEL NUMBERS ARE GIVEN THESE ARE FOR REFERENCE ONLY. WRITTEN 2. 3. 4. 5. SPECIFICATION REQUIREMENTS AND SCHEDULE NOTES HOLD PRESIDENCE. THE MORE STRIGENT SHALL APPLY SEE ARCHITECTURAL DWGS FOR MOUNTING HEIGHTS ON ALL WALL MOUNTED FIXTURES/EQUIPMENT, ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER ANY VALUES WITHIN THIS SCHEDULE. THE MINIMUM WASTE/VENT PIPE SIZE FOR BURIED PIPE SHALL BE 2". ALL ACCESIBLE FIXTURES SHALL COMPLY WITH ICC/ANSI A117.1 (ADA), REFERENCE ARCH DWGS FOR SPECIFIC LOCATIONS. SEE NOTE # ALL FIXTURES AND EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. REVISION/ISSUE --- P-TRAP --- DATE GUAGE & RELIEF VALVE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 WHEN INSIDE AIR TEMPERATURE IS ABOVE 79 DEG. F (ADJ.) AND OUTSIDE AIR TEMPERATURE IS ABOVE 75 DEG. F (ADJ.) EVAPORATIVE COOLER ISOLATION DAMPERS SHALL BE OPENED, EVAPORATIVE COOLERS FANS SHALL BE ENABLED AND MODULATED BETWEEN 20% TO FULL AIRFLOW TO MAINTAIN SPACE TEMPERATURE AT 80 DEG. F. (ADJ.). WHEN OUTDOOR AIR CANNOT SATISFY SPACE TEMPERATURE SETPOINT, THE NON-POTABLE SUPPLY WATER ISOLATION VALVE SHALL BE OPENED AND THE DRAIN ISOLATION VALVE SHALL BE CLOSED. EVAPORATIVE COOLER FANS SHALL AGAIN BE MODULATED BETWEEN 20% TO FULL AIRFLOW TO MAINTAIN SPACE TEMPERATURE. 3/4 JORDAN TECHNICAL PROVIDE A STANDALONE CONTROLLER FOR THE EVAPORATIVE COOLER AND EXHAUST FAN SYSTEM. SA-1527 JORDAN TECHNICAL CENTER EVAPORATIVE COOLERS: # WHERE NOTED THE PLUMBING FIXTURE, EQUIPMENT AND ASSOCIATED ACCESSORIES SA-1227 FEBRUARY 2 2016 DRAWN BY --- CHECKED BY --- SHALL BE ICC/ANSI A117.1 (ADA) COMPLIANT. EXPOSED CW, HW AND W PIPING ALONG WITH MIXING VALVE SHALL INSULATED. PIPING WITHIN CASEWORK THAT OPENS FOR FIXTURE USE IS CONSIDERED EXPOSED. SHEET DESCRIPTION MECHANICAL SCHEDULES AND DETAILS 11/9/2015 4:39:56 PM SHEET NUMBER SPECIFIC NOTES: 1. EQUIPMENT AND/OR ISOLATION VALVE SHALL BE CONCEALED (WITHIN ADJACENT WALL OR WITHIN CASEWORK). WHERE LOCATED IN WALL/CEILING COORDINATE FINAL DEVICE AND ACCESS DOOR LOCATION WITH ARCHITECT. 2. PROVIDE WITH ASSE 1070 RATED THERMAL MIXING VALVE (WMV-1) LOCATED DOWNSTREM OF FIXTURE STOPS UNLESS SERVED FROM AN ASSE 1070 RATED GROUP-FIXTURE THERMAL MIXING VALVE. MECHANICAL ISOMETRICS SCALE: N.T.S. 1 M3.02 D. 1.02 EXAMINATION OF PREMISES VISIT THE PREMISES BEFORE SUBMITTING BID AS NO EXTRAS WILL BE ALLOWED FOR LACK OF KNOWLEDGE OF EXISTING CONDITIONS. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SITE CONDITIONS TO THE OWNER PRIOR TO BID. E. HANDICAPPED FIXTURES 1. INSULATION OF PIPES UNDER HANDICAPPED LAVATORIES: INSULATE ANGLE STOP ASSEMBLIES AND DRAIN LINES WITH FOAM INSERT COVERED WITH 1/8" MINIMUM ABRASIVE RESISTANT EXTERIOR COVER WITH FASTENERS LOCATED OUT OF SIGHT, BROCAR TRAP WRAP KIT 500R AND 500HS, OR EQUIVALENT. FIELD-APPLIED JACKETS FIELD-APPLIED JACKETS SHALL COMPLY WITH ASTM C 921, TYPE I, UNLESS OTHERWISE INDICATED. 1.03 CODES AND STANDARDS COMPLY WITH ALL APPLICABLE CODES, LAWS, INDUSTRY STANDARDS AND UTILITY COMPANY REGULATIONS. METAL JACKET: 1. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, AVAILABLE PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1.04 UTILITIES INTERRUPTIONS COORDINATE ALL MECHANICAL UTILITY INTERRUPTIONS WITH THE PROPERTY MANAGER. PLAN WORK SO THAT THE DURATION OF THE INTERRUPTIONS IS KEPT TO A MINIMUM. SECTION 15600 - HEAT AND REFRIGERATION 1.01 PIPING MATERIALS A. PIPING 1. LOW PRESSURE (124 PSI AND LESS) LOW TEMPERATURE (249°F AND LESS) CONTRACTOR'S OPTION, EITHER STEEL OR COPPER FOR WATER PIPE AS OUTLINED BELOW. ALL FITTINGS TO BE LONG RADIUS PATTERN. A. 2. a. ALUMINUM JACKET: COMPLY WITH ASTM B 209, ALLOY 3003, 3005, 3105, OR 5005, TEMPER H-14. B. b. SHEET AND ROLL STOCK READY FOR SHOP OR FIELD SIZING. c. FINISH AND THICKNESS ARE INDICATED IN FIELD-APPLIED JACKET SCHEDULES. d. MOISTURE BARRIER FOR OUTDOOR POLYETHYLENE AND KRAFT PAPER. APPLICATIONS: 3-MIL- THICK, HEAT-BONDED e. FACTORY-FABRICATED FITTING COVERS: DESIGNER NOTE:EDIT IF NOT REQUIRED. C. 1) SAME MATERIAL, FINISH, AND THICKNESS AS JACKET. 1.09 PRODUCT OPTIONS AND SUBSTITUTIONS A. SOME MATERIALS ARE SPECIFIED BY MANUFACTURER'S NAME. MATERIALS OF EQUIVALENT QUALITY MAY BE USED IF EQUIVALENT. D. 2) PREFORMED 2-PIECE OR GORE, 45- AND 90-DEGREE, SHORT- AND LONG-RADIUS ELBOWS. 7) VALVE COVERS. 8) FIELD FABRICATE FITTING COVERS ONLY IF FACTORY-FABRICATED FITTING COVERS ARE NOT AVAILABLE. END OF SECTION CONTRACTOR TO BE RESPONSIBLE FOR ANY CHANGES AND COSTS TO ACCOMMODATE ANY EQUIPMENT EXCEPT THE FIRST NAMED IN THE SPECIFICATION. 1.01 SCOPE OF WORK DO THE WORK IN ACCORDANCE WITH THE NFPA RECOMMENDATIONS AND COMPLY WITH ALL JURISDICTIONAL CODES. 1.02 1.12 PROTECTION OF WORK AND PROPERTY A. BE RESPONSIBLE FOR THE PROTECTION OF EXISTING FACILITIES WHETHER OR NOT SUCH FACILITY IS TO BE REMOVED OR RELOCATED. MOVE OR REMOVE ANY FACILITY SO AS NOT TO CAUSE INTERRUPTION OF THE WORK OR OWNER'S OPERATION. CLOSE ENDS OF PIPE AND DUCTWORK DURING CONSTRUCTION WITH CAPS OR PLUGS TO PREVENT ENTRY OF FOREIGN MATERIAL. C. 1.14 S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt 1.16 MOTORS MOTORS SHALL INCLUDE THERMAL OVERLOAD PROTECTION AND SHALL BE GUARANTEED TO OPERATE CONTINUOUSLY AT FULL LOAD WITH TEMPERATURE RISE IN ANY PART NOT TO EXCEED NEMA STANDARDS. MOTOR SHALL BE COMMERCIALLY, DYNAMICALLY BALANCED AND TESTED AT THE FACTORY BEFORE SHIPMENT AND SELECTED FOR QUIET OPERATION. 1.17 STARTERS PROVIDE STARTERS OF CURRENT AND CAPACITY RATINGS TO SERVE THE MOTOR INTENDED. STARTERS SHALL BE BUILT AND SIZED IN ACCORDANCE WITH NEMA STANDARDS FOR INDUSTRIAL CONTROL EXCEPT NO CONTACTORS SHALL BE SMALLER THAN NEMA SIZE 1. ALL THREE PHASE STARTERS TO HAVE AN AMBIENT COMPENSATED TRIP FREE, THERMAL OVERLOAD RELAY IN EACH UNGROUNDED PHASE CONDUCTOR. THERMAL OVERLOAD RELAYS SHALL BE BLOCK TYPE WITH BUILT-IN HEATERS OR AN ADJUSTABLE DIAL TO SET TO EXACT MOTOR FULL LOAD AMPS. 1.18 FLUSHING, CLEANING AND STERILIZING BEFORE FINAL CONNECTIONS ARE MADE IN THE PIPING SYSTEMS, SYSTEMS SHALL BE BLOWN OUT WITH AIR AND THEN COMPLETELY WASHED OUT WITH CLEANING COMPOUNDS COMPATIBLE WITH FINAL FLUID TO AVOID CONTAMINATION. THE SYSTEMS SHALL THEN BE FLUSHED FOR THE COMPLETE REMOVAL OF ALL FOREIGN MATERIALS. FURNISH ALL TEMPORARY CONNECTIONS, VALVES, ETC., REQUIRED FOR THIS PURPOSE. 1.19 AFTER FLUSHING, STERILIZE THE DOMESTIC WATER SYSTEM IN ACCORDANCE WITH AWWA STANDARD C651-85, DISINFECTING WATER MAINS, AND ALL SUBSEQUENT ADDENDA. AFTER MINIMUM CONTACT PERIOD, FLUSH THE SYSTEM WITH CLEAN WATER UNTIL THE RESIDUAL CHLORINE IS NO GREATER THAN THE CITY WATER. SUBMIT TO THE ARCHITECT, WRITTEN CERTIFICATION THAT STERILIZATION HAS BEEN PERFORMED. PROVIDE A COPY TO THE OWNER. PROVIDE A TEST ANALYSIS BY THE STATE HEALTH DEPARTMENT OF A RANDOM WATER SAMPLE, IF REQUESTED BY THE ARCHITECT. HWS/HWR PIPING 1. ALL HOT WATER SUPPLY LINES AND CIRCULATING WATER LINES INSULATE WITH U.L. FAN, DRIVE AND MOTOR SECTION FAN AND DRIVE ASSEMBLIES: STATICALLY AND DYNAMICALLY BALANCED AND DESIGNED FOR CONTINUOUS OPERATION AT MAXIMUM-RATED FAN SPEED AND MOTOR HORSEPOWER. SHAFTS: DESIGNED FOR CONTINUOUS OPERATION AT MAXIMUM-RATED FAN SPEED AND MOTOR HORSEPOWER, AND WITH FIELD-ADJUSTABLE ALIGNMENT. FAN HOUSINGS: STEEL FRAME AND PANEL. FAN SHAFT BEARINGS: GREASE-LUBRICATED, TAPERED-ROLLER BEARINGS: SELF-ALIGNING, PILLOW-BLOCK TYPE WITH DOUBLE-LOCKING COLLARS AND 2-PIECE, CAST-IRON HOUSING WITH GREASE LINES EXTENDED TO OUTSIDE UNIT AND A RATED LIFE OF L50 200,000 HOURS ACCORDING TO ABMA 11. MOTOR: COMPLY WITH NEMA DESIGNATION, TEMPERATURE RATING, SERVICE FACTOR, ENCLOSURE TYPE, AND EFFICIENCY REQUIREMENTS FOR MOTORS. ENCLOSURE TYPE: TOTALLY ENCLOSED, FAN COOLED. NEMA PREMIUM (TM) EFFICIENT MOTORS AS DEFINED IN NEMA MG 1. MOTOR SIZES: MINIMUM SIZE AS INDICATED. IF NOT INDICATED, LARGE ENOUGH SO DRIVEN LOAD WILL NOT REQUIRE MOTOR TO OPERATE IN SERVICE FACTOR RANGE ABOVE 1.0. WASTE AND VENT PIPING A. MATERIALS; WASTE AND VENT PIPING (INSIDE BUILDING) 1. BELOW GRADE: COATED SERVICE WETH CAST IRON WITH BELL AND SPIGOT FITTINGS WITH ELASTOMERIC JOINTS (ASTM C564 GASKETS) OR COATED HUBLESS CAST IRON WITH GASKET (ASTM C564) TYPE 304 STAINLESS STEEL SHIELD AND WORM DRIVE AND CLAMP FITTINGS OR CAST IRON COUPLINGS WITH TYPE 304 STEEL BOLTS AND GASKETS (ASTM C564) APPROVED FOR BELOW GRADE APPLICATIONS AND INSTALLED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. BELL AND SPIGOT TYPE PIPE SHALL BE USED UNDER BUILDING SLABS, NO HUB PIPING IN NOT ALLOWED. 2. SECURE FIXTURES TO WALLS AND FLOOR OR COUNTERTOPS IN ACCORDANCE WITH MANUFACTURER'S ROUGHING-IN AND SETTING REQUIREMENTS AND FORM A RIGID INSTALLATION. 3. ALL PIPE AT THE FIXTURES WHICH MAY BE EXPOSED TO VIEW SHALL BE BRASS CHROME FINISH, FINISHED WITH CHROME ESCUTCHEONS WHERE THEY PROJECT FROM WALLS AND FLOORS. 4. B. CONTROLLERS, ELECTRICAL DEVICES, AND WIRING: COMPLY WITH REQUIREMENTS FOR ELECTRICAL DEVICES AND CONNECTIONS SPECIFIED IN ELECTRICAL SECTIONS. MOUNT UNIT-MOUNTED DISCONNECT SWITCHES ON EXTERIOR OF UNIT. STOP VALVES SHALL BE FURNISHED AND INSTALLED AT ALL FIXTURES, FOR ALL EQUIPMENT AND AT ROUGH-IN LOCATIONS. 5. FURNISH AND INSTALL AIR GAP FITTING ON DISHWASHER WASTE. 6. ALL PLUMBING TRIM, VALVES, ETC. TO MEET LOCAL WATER CONSERVATION CODE AS DETERMINED BY AUTHORITY HAVING JURISDICTION. 7. SECURELY ANCHOR FLUSH VALVES BEHIND OR WITHIN WALLS TO BE RIGID AND NOT SUBJECT TO MOVEMENT DUE TO PUSH OR PULL ACTION ON THE VALVE. ADJUSTING AND CLEANING 1. AT COMPLETION, THOROUGHLY CLEAN PLUMBING FIXTURES AND EQUIPMENT. INCLUDING, BUT NOT LIMITED TO STRAINERS, AERATORS AND VALVES. A. B. C. D. E. F. ACCESSORIES AND OPTIONS TO INCLUDE: WALL SHUTTERS, MOTORIZED TYPE - INTERCONNECT ALUMINUM BLADES, EACH PIVOT ON NYLON BEARINGS, EXTRUDED ALUMINUM FRAME. LINE VOLTAGE MOTOR (110V, 208V, 230V, 460V) IS POWER OPEN, SPRING RETURN, ELECTRICALLY INTERLOCKED IN PARALLEL WITH FAN. WALL SLEEVE - GALVANIZED STEEL. WEATHER SHIELD WITH FRONT GUARD - GALVANIZED STEEL. TOTALLY ENCLOSED MOTOR V-BELT DRIVE FAN GUARD - INLET - EXTRUDED ALUMINUM FRAME GUARD OSHA APPROVED SEE SCHEDULE FOR CAPACITY, MOTOR, AND ACCESSORY REQUIREMENTS. ACCEPTABLE MANUFACTURERS COOK ACME GREENHECK CIRCULATING FAN ALUMINUM PADDLE WITH STEEL HUB/SPIDER PROPELLER - LOCKING TILT POWDER COATED I-BEAM MOUNTING BRACKET - OSHA COMPLIANT DOUBLE LOCKING, CHROME PLATED STEEL WIRE GUARD TWO-SPEED, TOTALLY ENCLOSED PERMANENTLY LUBRICATED BALL BEARING MOTOR W/PULL CORD STYLE OPERATING SWITCH - FACTORY PRE-WIRED 12 FOOT CORD. SEE SCHEDULE FOR CAPACITIES. DIRECT EVAPORATIVE SECTION EVAPORATIVE HUMIDIFIER SECTION: SPRAY TREE ASSEMBLY: BRASS NOZZLES AND GALVANIZED PIPING, GALVANIZED ELIMINATOR PLATES WITH FLOODING NOZZLES AND HEADER, AND GALVANIZED ANTI-SPLASH BAFFLES, MEDIA. FILL AND DRAIN ASSEMBLY: PROVIDE A MECHANICAL FILL VALVE. PROVIDE A THREE-WAY FILL VALVE AND TWO-WAY DRAIN VALVE. TANK: WELDED STEEL TANK COPPER SUCTION SCREENS, DRAIN, OVERFLOW AND SUCTION CONNECTIONS. MAKEUP CONNECTION WITH BRASS FLOAT VALVE, AND WITH QUICK-FILL CONNECTION. ABOVE GRADE: SERVICE WEIGHT CAST IRON WITH BELL AND SPIGOT FITTINGS WITH ELASTOMERIC JOINTS (ASTM C564 GASKETS), HUBLESS CAST IRON WITH GASKET (ASTM C564) AND STAINLESS STEEL SHIELD AND WORM DRIVE CLAMP FITTINGS INSTALLED PER MANUFACTURER'S RECOMMENDATIONS, GALVANIZED STEEL PIPE WITH CAST IRON DRAINAGE FITTINGS WITH THREADED JOINTS OR DWV COPPER WITH WROUGHT COPPER OR CAST BRASS FITTINGS USING 95-5 (TIN/ANTIMONY) SOLDER JOINTS. 1.04 FIXTURES AND EQUIPMENT A. FIXTURES 1. INSTALL ALL FIXTURES AND/OR ROUGH-IN ACCORDING TO THE SPECIFICATIONS. 1.01 MATERIALS A. DOMESTIC COLD WATER AND NON-POTABLE WATER PIPE, VALVES AND FITTINGS. 1. INSULATE WITH U.L. APPROVED, FLAME RESISTANT, WHITE VAPOR BARRIER JACKETED, GLASS FIBER SNAP-ON INSULATION 1/2" THICK. INSULATE VALVES AND FITTINGS WITH GLASS FIBER BLANKET INSULATION AND PREMOLDED PVC COVERS (COVERS TO BE U.L. 25/50 RATED). WHERE THE USE OF PVC COVERS IN PLENUMS, ETC., IS RESTRICTED BY VARIOUS CODES VALVES AND FITTINGS SHALL BE INSULATED BY WRAPPING WITH BLANKET INSULATION. COVER BLANKETS TO SAME DEPTH AS THE PIPE INSULATION WITH INSULATING CEMENT, TROWELED SMOOTH. IT IS THE CONTRACTOR'S AND MANUFACTURER'S RESPONSIBILITY TO ASSURE THEMSELVES THAT THE CODE AUTHORITY WILL APPROVE ANY PRODUCT TO BE INSTALLED ON THE PROJECT. MAXIMUM K-VALUE SHALL BE 0.24 BTU-IN/HR-SQ FT/DEGREES. C. UNIT CASING GENERAL FABRICATION REQUIREMENTS FOR CASINGS: FORMING: FORM WALLS, ROOFS, AND FLOORS WITH AT LEAST TWO BREAKS AT EACH JOINT. CASING JOINTS: SHEET METAL SCREWS OR POP RIVETS. SEALING: SEAL ALL JOINTS WITH WATER-RESISTANT SEALANT. VALVES AND SPECIALTIES BALL VALVES: BRONZE, FULL PORT, 400 LB. W.O.G. STRAINERS: 250 LB. BRONZE OR CAST IRON "Y" TYPE W/STAINLESS STEEL SCREEN. PRESSURE TEMP. TAPS: UNIVERSAL CONTROLS CORPORATION #45-PT-N. SISCO BNO-500 1/2 NPT, NORDEL CORE OR EQUIVALENT. 1.03 CLEANOUTS A. INSTALL FULL SIZE BRASS CLEANOUT PLUGS WHEREVER PIPES CHANGE DIRECTION 45 DEGREES OR MORE OR OTHERWISE REQUIRED. FOR PROPER CLEANING OF THE ENTIRE DRAINAGE SYSTEMS. BRASS PLUGS WITH CHROME PLATED COVER PLATES FOR WALLS, SCORIATED BRASS COVER FOR FLOOR INSTALLED FLUSH WITH FLOOR AND BRASS COVER WITH CARPET RING FOR CARPETED AREA, FLUSH WITH CARPET. WHEN OUTSIDE, HEAVY DUTY CAST IRON TRACTOR COVER SET IN TWO FOOT SQUARE BY 6" DEEP CONCRETE PAD OR IN CONCRETE OR ASPHALT SURFACE. "Y" IN THE LINE AND VERTICAL RISER OF C.I. PIPE. THE FAN FRAME AND VENTURI SHALL BE CONSTRUCTED OF 16 GAUGE PAINTED STEEL ON SIZES 42" THRU 48" AND 14 GA. PAINTED STEEL ON FAN SIZES 54" THRU 60". THE FAN ASSEMBLY SHALL BE BOLTED TO THE VENTURI FOR EASE OF REMOVAL AND MAINTENANCE. FAN BEARINGS SHALL BE HEAVY DUTY BALL OR ROLLER TYPE AND SELECTED FOR BASIC RATING LIFE (L10) OF 80,000 HOURS AT MAXIMUM SPEED AND HORSEPOWER PER ABMA STD 9 OR 11. FAN BLADES SHALL BE STATICALLY AND DYNAMICALLY BALANCED AT THE SPECIFIED RPM. ALL FANS HAVE OPEN DRIP PROOF MOTORS UNLESS NOTED OTHERWISE. DIRECT EVAPORATIVE COOLERS EC-# WATER PIPING A. PIPING (INSIDE BUILDING) 1. NON-BURIED LINES, TYPE "L" HARD DRAWN COPPER, WROUGHT COPPER FITTINGS AND LEAD FREE SOLDER: 96-4 (TIN/SILVER), SILVABRILE 100, OR CANFIELD 100% WATERSAFE (SILVER-TIN COPPER) SOLDER. WHERE COPPER TUBE IS JOINED TO BRASS OR BRONZE, USE BCuP2 CLASSIFICATION BRAZING ALLOY. 2. PROPELLER SHALL BE OF THE BELT DRIVEN TYPE AND SHALL INCORPORATE A HEAVY DUTY CAST ALUMINUM PROPELLER. THE PROPELLER SHALL CONSIST OF SIX CAST ALUMINUM BLADES MOUNTED IN A CAST ALUMINUM HUB. THE DESIGN SHALL PERMIT THE REPLACEMENT OF BLADES WITHOUT THE NECESSITY OF REPLACING THE ENTIRE PROPELLER. THE PITCH OF THE BLADES SHALL BE SET AT THE FACTORY AND LOCKED INTO PLACE BY MEANS OF A TAPER LOCK PIN. ACCEPTABLE MANUFACTURERS:TRANE VULCAN MODINE ENGINEERED AIR V SERIES FIRE PROTECTION SHOP DRAWINGS CONTRACTOR TO SUBMIT FIRE PROTECTION SHOP DRAWINGS TO ENGINEER FOR APPROVAL PRIOR TO SUBMITTING TO BUILDING DEPARTMENT. SECTION 15250 - INSULATION DOMESTIC HOT WATER PIPING AND FITTINGS. 1. ALL HOT WATER SUPPLY LINES AND CIRCULATING WATER LINES INSULATE WITH U.L. APPROVED, FRAME RESISTANT, WHITE ALL SERVICE JACKETED, GLASS FIBER SNAP-ON PIPE INSULATION 1" THICK. INSULATE FITTINGS WITH GLASS FIBER BLANKET INSULATION AND PREMOLDED PVC COVERS. MAXIMUM K-VALUE SHALL BE 0.24 BTU-IN/HR-SQ FT/DEGREES. INSTALL FLEXIBLE CONNECTIONS BETWEEN FAN DISCHARGE DUCTWORK. ENSURE METAL BANDS OF CONNECTORS ARE PARALLEL WITH A MINIMUM OF ONE INCH FLEX BETWEEN DUCTWORK AND FAN WHILE RUNNING. SEE SCHEDULE FOR CAPACITIES. SPRINKLER HEADS TO BE UL LISTED STANDARD SPRAY SPRINKLER HEADS, NOMINAL TEMPERATURE RATINGS (165°F) EXCEPT WHERE HIGH TEMPERATURE HEADS ARE REQUIRED. NEW HEADS TO BE SAME MAKE AND MODEL AS EXISTING. END OF SECTION B. C. G. 2. 1.02 DO NOT OPERATE FAN FOR ANY PURPOSE UNTIL DUCTWORK IS CLEAN, FILTERS ARE IN PLACE AND BEARINGS LUBRICATED. PANEL PROPELLER WALL FAN COMPLETE WITH FRAME AND MOTOR SIDE GUARD. EACH WARRANTY FOR LONGER THAN THE ONE YEAR DESCRIBED ABOVE (THAT COMES WITH EQUIPMENT USED ON THE JOB) SHALL BE PASSED ONTO THE OWNER WITH DATES OF START AND END OF WARRANTY. 1.15 PROJECT RECORD DRAWINGS PROVIDE THE ARCHITECT WITH ONE CLEAN SET OF PLANS AND SPECIFICATIONS CORRECTED UP-TO-DATE AS JOB PROGRESSES. B. VERTICAL MODEL WITH ADJUSTABLE DIFFUSER COPPER TUBE AND ALUMINUM FIN COIL. DIRECT DRIVE PROPELLER FAN WITH SAFETY FAN GUARD. MOTOR SHALL HAVE BUILT_IN OVERLOADS. SUSPEND AS REQUIRED. SECTION 15400 - PLUMBING SUBMIT COMPLETED BALANCE REPORTS TO OWNER AND ENGINEER FOR THEIR REVIEW AND RECORDS. CENTRIFUGAL FANS A. MOUNT UNITS ON COMMON FAN AND MOTOR INERTIA BASE WITH SPRING VIBRATION ISOLATORS. SEE SECTION 15050. WET SPRINKLER SYSTEM F. GENERAL. DRAWINGS SHOW THE EXTENT AND GENERAL ARRANGEMENT OF THE SYSTEM. CENTER ALL HEADS IN CEILING TILE. END OF SECTION 1.01 ACCEPTABLE MANUFACTURERS: COOK GREENHECK PEERLESS, TWIN CITY NEW YORK BLOWER BARRY BLOWER PROPELLER FAN EF-2 H. WARRANTY A. ALL MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE SPECIFIED. GUARANTEE ALL WORKMANSHIP, MATERIAL AND EQUIPMENT AND REPLACE ANY FOUND DEFECTIVE WITHOUT COST TO THE OWNER, FOR ONE YEAR AFTER FINAL ACCEPTANCE, AS DEFINED IN GENERAL CONDITIONS. B. 11/9/2015 4:39:56 PM ADJUST AND BALANCE ALL AIR AND WATER SYSTEMS. CHECK, ADJUST AND BALANCE ALL SYSTEMS TO MEET THE DESIGN CONDITIONS AND TABULATE ALL INFORMATION ON ACCEPTABLE FORMS. ALL SYSTEMS SHALL BE CHECKED FOR PROPER PERFORMANCE DURING DESIGN CONDITIONS, BOTH HEATING AND COOLING D. VALVES AND SPECIALTIES. BALL VALVES: BRONZE, FULLPORT, 400 LB. W.O.G. PLUG VALVES: 175 LB. W.O.G. BALANCING VALVES: 250 PSIG AT 250°F BELL AND GOSSETT CB (1/2"-3") OR EQUIVALENT. STRAINERS: 250 LB. SEMI-STEEL ORCAST IRON "Y" TYPE SCREWED WITH STAINLESS STEEL SCREEN. 20 MESH STANDARD. EQUIPMENT 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com SEE SCHEDULE FOR CAPACITIES. UNIT HEATER UH-# 1.13 BALANCING A. THE BALANCING OF THE SYSTEM SHALL BE PART OF THIS CONTRACT, INCLUDE IN BID THE COST OF BALANCING AND ADJUSTING. B. FLEXIBLE PIPE CONNECTORS: FLEXIBLE STAINLESS STEEL OR BRONZE ANNULAR HOSE AND BRAID. MASONS ESS GU-MN, BSSGU-RF OR BBF, OR EQUIVALENT. 4. SECTION 15300 - FIRE PROTECTION B. 3. 6) BEVELED COLLARS. PERFORMANCE SPECIFICATION. WHEN ANY ITEM IS SPECIFIED BY REQUIREMENT TO MEET A PERFORMANCE, INDUSTRY OR REGULATING BODY STANDARD OR IS SPECIFIED BY A GENERIC SPEC, (NO MANUFACTURER'S NAME LISTED) NO PRIOR APPROVAL BY THE CONSULTING MECHANICAL ENGINEER IS NEEDED UNLESS SPECIFICALLY CALLED FOR IN THESE SPECIFICATIONS. 1.11 INSTALLATION AND ARRANGEMENT INSTALL ALL WORK TO PERMIT REMOVAL OF COILS, SHAFTS AND WHEELS, FILTERS, AND ALL OTHER PARTS WHICH MIGHT REQUIRE PERIODIC REPLACEMENT OR MAINTENANCE. MATERIAL IS CONNECTED TO NON-FERROUS MATERIAL AND WHERE FERROUS MATERIAL IS CONNECTED TO DOMESTIC WATER PIPING. COUPLINGS (WATERWAYS') CAN BE USED WHENEVER UNIONS ARE NOT REQUIRED. 4) FLANGE AND UNION COVERS. 5) END CAPS. CONSULTING ENGINEERS, INC. ACCESSORIES TO INCLUDE: INLET/OUTLET SCREENS: GALVANIZED STEEL WELDED GRID. ACCESS DOOR: SHAPED TO CONFORM TO SCROLL WITH QUICK OPENING LATCHES AND GASKETS. PROVIDE WITH A FACTORY INSTALLED AUTOMATIC BELT TENSIONER TO MAINTAIN PROPER BELT TENSION. VALVES AND SPECIALTIES 1. GLOBE VALVES OR PLUG VALVES MAY BE USED AS BALANCING VALVES. PROVIDE ADJUSTABLE MEMORY STOPS ON ALL VALVES USED FOR BALANCING SERVICE. DIELECTRIC UNIONS ARE TO BE USED AT ALL CONNECTIONS WHERE FERROUS 2. 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com PROVIDE V_BELT DRIVE AND OSHA APPROVED METAL GUARD WITH PROVISIONS FOR BELT TENSION ADJUSTMENT, LUBRICATION AND USE OF TACHOMETER WITH GUARD IN PLACE. MOTORS AND STARTERS AS DETAILED IN MECHANICAL/ELECTRICAL EQUIPMENT SCHEDULE. COPPER PIPE 1. HOT WATER HEATING PIPING, CHILLED WATER PIPING AND CONDENSER WATER PIPING INCLUDING THOSE FILLED WITH GLYCOL SOLUTIONS. FOR NON-BURIED LINES; TYPE "L" HARD DRAWN COPPER ASTM B88 WITH WROUGHT COPPER FITTINGS AND 95-5 (TIN/ANTIMONY), 96-4 (TIN/SILVER) OR CANFIELD 100% WATERSAFE (SILVER/TIN/COPPER) SOLDER. WHERE COPPER PIPE IS JOINTED TO BRASS USE BCUP2 CLASSIFICATION BRAZING ALLOY. 3) TEE COVERS. BIDDER'S CHOICE MATERIALS OR EQUIPMENT LISTED BY SEVERAL MANUFACTURER'S NAMES ARE INTENDED TO BE BIDDER'S CHOICE, AND ANY OF THE LISTED MANUFACTURERS MAY BE BID WITHOUT SOLICITING PRIOR APPROVAL. 1.10 SHOP DRAWINGS A. SUBMIT SHOP DRAWINGS FOR ALL EQUIPMENT NAMED IN THESE SPECIFICATIONS, SHOWING ANY CHANGES REQUIRED IN PIPING, DUCTING, ELECTRICAL WIRING, ETC. BE RESPONSIBLE TO MAKE ALL CHANGES REQUIRED TO ACCOMMODATE AND TO PAY FOR THESE CHANGES. SUBMIT AT LEAST 3 COPIES. DO NOT BEGIN UNTIL AT LEAST 1 COPY IS RETURNED. FITTINGS ON EXPOSED PIPE 2" AND UNDER MAY BE 125 LB. CAST IRON SCREWED, OR FOR ANY WATER LINES, 150 LB. MALLEABLE IRON SCREWED. FITTINGS ON CONCEALED PIPE, USE FORGED STEEL, STANDARD WEIGHT, BUTT WELD OR SOCKET WELDED. EQUIPMENT SCHEDULE GRILLES, REGISTERS AND DIFFUSERS ALL PERFORATED FACE SUPPLY DIFFUSERS TO HAVE ROUNDNECK. ALL PERFORATED FACE AND LOUVER FACE DIFFUSERS, REGISTERS AND GRILLES TO HAVE OFF WHITE BAKED ENAMEL FINISH AND REMOVABLE FACE OR CORE. WHEN THESE DIFFUSERS, REGISTERS OR GRILLES ARE USED IN GRID OR GYP. BOARD CEILINGS, FRAME TO BE SUITABLE FOR TYPE OF CEILING IN WHICH THEY ARE INSTALLED. ALL DIFFUSERS AND REGISTERS SHALL BE EQUIPPED WITH OPPOSED BLADE DAMPERS UNLESS SUPPLIED FROM A SPIN-IN FITTING WITH DAMPER. SIZE AND CFM AS SHOWN ON PLANS. ALL CEILING DIFFUSERS TO BE 4-WAY THROW UNLESS NOTED OTHERWISE ON PLANS. CENTRIFUGAL FAN EF-1 CENTRIFUGAL FAN WITH FLAT BLADE, MOUNT ON 14" CURB. WHEEL LICENSED TO BEAR THE AMCA CERTIFIED RATING SEAL. FAN RATINGS SHALL BE IN ACCORDANCE WITH AMCA STANDARD 2408.69. FAN WHEEL AND HOUSING SHALL BE CONTINUOUS WELDED CONSTRUCTION. HOT ROLLED STEEL, GROUND AND POLISHED FAN SHAFT. HEAVY DUTY PILLOW BLOCK TYPE, SELF_ALIGNING, GREASE LUBRICATED BEARINGS SELECTED FOR BASIC RATING LIFE(L10) OF 80,000 HOURS AT MAXIMUM SPEED AND HORSEPOWER PER ABMA STD 9 OR 11. FAN SHALL BE STATICALLY AND DYNAMICALLY BALANCED. RUN TEST FAN, AT THE FACTORY, AT OPERATING RPM OR MAXIMUM CLASS RPM WITH MOTOR AND DRIVE IN PLACE. RPR PRODUCTS, INC.; INSUL-MATE. 1.07 DRAWINGS MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE SCALED FOR DIMENSIONS. INSTALL THE SYSTEMS COMPLETE IN THE SPACE PROVIDED WITHOUT EXTRA CHARGES TO THE OWNER. C. STEEL PIPE 1. HEATING WATER PIPING 4" AND LESS; SCHEDULE 40, ASTM-A106 GRADE B GALVANIZED STEEL PIPING WITH 150 LB. GALVANIZED, MALLEABLE IRON, SCREWED FITTINGS. CLASSIFICATION ALLOY. ITW INSULATION SYSTEMS; ALUMINUM AND STAINLESS STEEL JACKETING. 1.06 PERMITS, FEES AND NOTICES PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS DIVISION. DO NOT INCLUDE THE COST OF THE "PLANT INVESTMENT FEE" FOR SEWER AND WATER OR GAS APPLICATION FEE CHARGED BY THE UTILITY COMPANY. B. D. END OF SECTION CHILDERS BRAND, SPECIALTY CONSTRUCTION BRANDS, INC., A BUSINESS OF H. B. FULLER COMPANY; METAL JACKETING SYSTEMS. 1.05 EQUIPMENT FURNISHED BY OWNER NONE. ADJUST FLUSH VALVES, FAUCETS, SHOWERS AND BUBBLERS FOR PROPER FLOW, AFTER CLEANING AND FLUSHING OPERATIONS ARE ACCOMPLISHED. ACCEPTABLE MANUFACTURERS: COOK GREENHECK PEERLESS TWIN CITYMA NEW YORK BLOWER BARRY BLOWER COMMERCIAL SECTION 15900 CONTROL SEE SCHEDULE FOR CAPACITIES. ACCEPTABLE MANUFACTURERS: ESSICS PHOENIX INDUSTRIES END OF SECTION SECTION 15800 - AIR DISTRIBUTION 1.01 MATERIALS & EQUIPMENT A. DUCTWORK AND FITTINGS 1. SIZES SHOWN ON THE DRAWINGS ARE OUTSIDE (SHEET METAL) DUCT DIMENSIONS DUCTWORK SHALL BE SHEET-METAL FURNISHED AND INSTALLED IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS OR INTERNATIONAL MECHANICAL CODE, WHICH EVER IS MORE STRINGENT. ALL DUCTWORK TO BE ASTM A525 AND ASTM A527 GALVANIZED SHEET STEEL, LOCK FORMING QUALITY, HAVING G-90 ZINC COATING IN PERFORMANCE WITH ASTM A90. WRAP ALL SUPPLY DUCT ON THE OUTSIDE WITH INSULATION. DUCT LINER IS NOT ALLOWED. DUCT PRESSURE SHALL NOT BE LESS THAN 3" TOTAL STATIC STATIC PRESSURE FOR SUPPLY DUCT; -1/2" W.G. FOR RETURN DUCT. USE THIS SECTION FOR DUCT WRAP AND LINER. 2. A. ROUND DUCT TAKE-OFF FITTINGS SPIN-IN FITTING FOR ROUND DUCT CONNECTION. FACTORY FABRICATED 26 GAUGE(ALL DIAMETERS) G-90 GALVANIZED SHEET METAL FOR INSULATED DUCTS. BUTTERFLY DAMPER WITH QUADRANT OPERATOR AND LOCK NUT ON ALL APPLICATIONS EXCEPT VAV SYSTEM UP STREAM OF VAV BOX. B. LATERAL TAKE-OFF FITTING FACTORY FABRICATED 26 GAUGE (ALL DIAMETERS) G-90 GALVANIZED SHEET METAL FITTINGS WITH 45 DEGREE ANGLE TAKE-OFF, ADHESIVE COATED GASKET, 1" MOUNTING FLANGE AND BUTTERFLY DAMPER WITH QUADRANT OPERATOR AND LOCK NUT ON ALL APPLICATIONS EXCEPT VAV SYSTEMS UPSTREAM OF VAV BOX. C. DUCT SEALANT NON-HARDENING, WATER RESISTANT, NON COMBUSTIBLE, LIQUID OR MASTIC OR WITH TAPE AS RECOMMENDED BY MANUFACTURER. ALL SEALANTS SHALL HAVE APPROVED FIRE RATING FOR PLENUM APPLICATION AS REQUIRED BY CODE AUTHORITY. 1.01 DESCRIPTION A. WORK INCLUDED 1. PROVIDE AN AUTOMATIC TEMPERATURE CONTROL (ATC) SYSTEM OF DIRECT DIGITAL CONTROLS WITH SOLID STATE ELECTRONIC AND ELECTRIC COMPONENTS IF REQUIRED, TO COMPRISE A COMPLETE SYSTEM, FURNISHED AND INSTALLED BY THE CONTRACTOR. 2. DIRECT DIGITAL CONTROL SHALL BE DEFINED AS A CONTROL TECHNIQUE THROUGH WHICH THE PROCESS VARIABLE IS CONTINUOUSLY MONITORED BY A DIGITAL MICROPROCESSOR COMPUTER WHICH ACCOMPLISHES LOOP CONTROL BY CALCULATING A CONTROL SOLUTION FOR OUTPUT TO A CONTROL DEVICE. 3. THE SYSTEM SHALL BE COMPLETE IN ALL RESPECTS, PUT IN OPERATION AND CALIBRATED UNDER OCCUPIED CONDITIONS. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL SEQUENCES OF OPERATIONS EVEN IF EQUIPMENT AND CONTROLS ARE FURNISHED BY OTHERS. FOR SEQUENCES SPECIFIED IN OTHER SECTIONS, IF EQUIPMENT AND CONTROLS ARE FURNISHED BY OTHERS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING SEQUENCES OF CONTROLS AND COORDINATION. DATE PROJECT NO. 1.02 WIRING A. ALL WIRING SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (LATEST EDITION), LOCAL CODES AND THE ELECTRICAL DIVISION OF THESE SPECIFICATIONS. B. DATE DRAWN BY ALL CONTROL INTERLOCKS AND WIRING DONE AT THE FACTORY, AND 120 V POWER CIRCUITS TO EACH CONTROL PANEL OR CONTROL PANELS SHALL BE WIRED BY THE CONTRACTOR. POWER CIRCUITS SHALL BE PROVIDED UNDER THE ELECTRICAL DIVISION. CHECKED BY C. IF 120 VOLT POWER CIRCUITS ARE REQUIRED, POWER CIRCUITS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 1.03 WARRANTY A. IN ACCORDANCE WITH SECTION 15010 THE CONTROL SYSTEM SHALL BE WARRANTEED TO BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIAL FOR THE PERIOD OF ONE YEAR. THE CONTRACTOR SHALL MAKE ALL NECESSARY REPAIRS, ADJUSTMENTS AND REPLACEMENT AT NO COST TO THE OWNER DURING THE WARRANTY PERIOD. 1.04 ACCEPTABLE MANUFACTURERS AND INSTALLERS THE CONTRACTOR IS RESPONSIBLE FOR ALL CONTROLS FIELD INSTALLED OR MANUFACTURER INSTALLED. CONTRACTOR MAY SUBCONTRACT ANY OR ALL WORK BUT MUST BE RESPONSIBLE FOR THE SUBCONTRACTOR'S WORK. REVISION/ISSUE SA-1227 FEBRUARY 2 2016 ----- SHEET DESCRIPTION MECHANICAL SPECIFICATIONS SHEET NUMBER MECHANICAL SPECIFICATIONS SCALE: NO SCALE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 1.01 SCOPE OF WORK WORK SHALL CONSIST OF FURNISHING ALL LABOR AND MATERIALS NECESSARY FOR THE INSTALLATION OF COMPLETE AND OPERATING MECHANICAL SYSTEMS. COORDINATE ALL MECHANICAL WORK WITH THE PROGRESS OF ALL OTHER TRADES. 2. JORDAN TECHNICAL APPROVED, FRAME RESISTANT, WHITE ALL SERVICE JACKETED, GLASS FIBER SNAP-ON PIPE INSULATION 1-1/2" THICK. INSULATE FITTINGS WITH GLASS FIBER BLANKET INSULATION AND PREMOLDED PVC COVERS. MAXIMUM K-VALUE SHALL BE 0.24 BTU-IN/HR-SQ FT/DEGREES. SA-1527 JORDAN TECHNICAL CENTER DIVISION 15 MECHANICAL SECTION 15010 GENERAL PROVISIONS 1 M4.01 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com GENERAL NOTES (FOR ALL ELECTRICAL SHEETS) NOTE: ALL SYMBOLS SHOWN ON LEGEND STRAIGHT BLADE DUPLEX RECEPTACLE SUBSCRIPTS: AC = 6" ABOVE COUNTER DISCONNECT SWITCH STRAIGHT BLADE GFI DUPLEX RECEPT MAGNETIC MOTOR STARTER SUBSCRIPTS: MS CONNECTION TO MOTOR MAGNETIC MOTOR STARTER SUBSCRIPTS: MS = MULTISPEED SSRV = SOLID-STATE, REDUCED VOLTAGE VF = MULTISPEED SSRV = SOLID-STATE, REDUCED VOLTAGE WALL MOUNTED OUTLET BOX = VARIABLE FREQUENCY SAFETY DISCONNECT SWITCH COMBINATION DISCONNECT AND STARTER CONNECTION TO PRE-WIRED EQUIPMENT PANELBOARD VF CIRCUIT BREAKER, MOLDED-CASE, THERMAL-MAGNETIC FIXED SUBSCRIPTS: AT CL = CURRENT LIMITING IC = INSULATED CASE ST = SHUNT TRIP KI = KEY INTERLOCK ZSI = ZONE-SELECTIVE INTERLOCKING ENCLOSED CIRCUIT BREAKER, MOLDED-CASE, THERMAL-MAGNETIC FIXED CURRENT TRANSFORMER CIRCUIT HOMERUN TO PANEL OR CABINET, NO. OF ARROWS INDICATE NO. OF CIRCUITS GROUND FAULT PROTECTION SEALOFF SWITCHING WALL MOUNTED SWITCH SUBSCRIPTS: T = THERMAL OVERLOAD S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt LV = LOW VOLTAGE 4. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER. 500 West 18th Street, Suite 200 Cheyenne, WY 82001-4368 307.634.7647 5. ALL 120V BRANCH CIRCUITS SHALL BE 3-WIRE (PHASE,NEUTRAL,GROUND). PHASE, NEUTRAL, AND GROUND CONDUCTORS SHALL BE SIZE 12 AWG UNLESS OTHERWISE NOTED. BRANCH CIRCUITS SHOWN AS A SINGLE HOMERUN SHALL NOT BE COMBINED WITH OTHER CIRCUITS. ALL BRANCH CIRCUITS AND FEEDERS SHALL HAVE EQUIPMENT GROUNDING CONDUCTORS INSTALLED IN THE RACEWAY. 6. THE CONTRACTOR SHALL MAINTAIN FIRE-RATINGS FOR ALL CONDUIT PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION. 7. ALL MOUNTING OF ELECTRICAL DEVICES (LUMINAIRES, TRANSFORMERS, PANELS, OUTLETS, CONDUIT RUNS, ETC.) SHALL COMPLY WITH STATE AND LOCAL SEISMIC REQUIREMENTS. ALL LUMINAIRES SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING SUPPORT HANGERS IN COMPLIANCE WITH IBC AND NEC REQUIREMENTS. 8. ADA COMPLIANCE: ELECTRICAL DEVICES PROJECTING FROM THE WALLS WITH THEIR LEADING EDGES BETWEEN 27" AND 80" AFF SHALL PROTRUDE NO MORE THAN 4" INTO WALKWAYS OR CORRIDORS. 9. GFCI DEVICES SHALL BE PROVIDED AS NOTED AND SHALL COMPLY WITH NEC AND LOCAL REQUIREMENTS. NO FEED-THRU GFCI PROTECTION SHALL BE PERMITTED FOR DOWNSTREAM DEVICES. GFCI DUPLEX RECEPTACLES SHALL BE UL 943 2006 "LOCK-OUT" ACTION OR "NOTIFICATION" COMPLIANT. 175 North 27th Street, Suite 1312 Billings, MT 59101-2048 406.256.1141 GFCI = GROUND FAULT CIRCUIT INTERRUPTER CONDUIT RUN CONDUIT STUB-OUT - CAP & MARK 7600 East Orchard Road, Suite 250-S Greenwood Village, CO 80111-2518 303.796.6000 www.mkkeng.com EAT = ELECTRONIC ADJUSTABLE TRIP POWER TRANSFORMER CIRCUIT TURNED DOWN COORDINATE ALL EQUIPMENT LOCATIONS WITH THE OWNER PRIOR TO ROUGH-IN. COORDINATE THE WIRING DEVICE LOCATIONS WITH THE ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, AND EQUIPMENT INSTALLATION DRAWINGS. COORDINATE THE LOCATION OF THE MECHANICAL EQUIPMENT WITH THE MECHANICAL PLANS AND THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. COORDINATE THE LOCATION OF THE LUMINAIRES WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. = ADJUSTABLE INSTANTANEOUS TRIP ENCLOSED FUSED DISCONNECT SWITCH CIRCUIT TURNED UP Mechanical, Electrical & Energy Consultants = VARIABLE FREQUENCY TRANSFORMER CIRCUITING 3. 50 years and counting! GROUND CONNECTION AS NOTED FUSES OUTLET BOX REFER TO THE ARCHITECTURAL PLANS, ELEVATIONS, AND DIAGRAMS FOR LOCATIONS OF THE FLOOR AND WALL DEVICES. IF DEVICES ARE NOT NOTED OTHERWISE THEY SHALL BE MOUNTED LONG AXIS VERTICAL AT THE FOLLOWING HEIGHTS AFF TO CENTER OF DEVICE: SWITCHES +48", RECEPTACLES +18", VOICE/DATA JACKS +18". CONSULTING ENGINEERS, INC. METER STRAIGHT BLADE DOUBLE DUPLEX RECEPT. (FOURPLEX) STRAIGHT BLADE GFI DUPLEX RECEPT ON S.O. CORD REEL 2. ABBREVIATIONS NOTE: ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED. AC AFC AFF AFG AIC CB CT EM EWC FLA GFI HP LC MCA MCB MLO OC SPD - ABOVE COUNTER - ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AMPS INTERRUPTING CURRENT - CIRCUIT BREAKER - CURRENT TRANSFORMER - EMERGENCY - ELECTRIC WATER COOLER - FULL LOAD AMPS - GROUND FAULT INTERRUPTER - HORSEPOWER - LIGHTING CONTACTOR - MINIMUM CIRCUIT AMPS - MAIN CIRCUIT BREAKER - MAIN LUGS ONLY - OVER CURRENT - SURGE PROTECTIVE DEVICE TVSS UG VFD WG WP XFMR - TRANSIENT VOLTAGE SURGE SUPPRESSOR - UNDERGROUND - VARIABLE FREQUENCY DRIVE - WIREGUARD - WEATHERPROOF - TRANSFORMER 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com 2/2/2016 10. THE INFORMATION ON THESE DRAWINGS HAS BEEN ASCERTAINED FROM EXISTING DRAWINGS AND FIELD OBSERVATIONS. THIS INFORMATION IS AS ACCURATE AS CONDITIONS WOULD ALLOW. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE, PRIOR TO BID, AND BECOME FAMILIAR WITH THE EXTENT OF THE WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE THAT ARE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. 11. ON DEMOLITION PLANS: ALL ITEMS SHOWN IN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. ALL ITEMS SHOWN IN HEAVY LINE WEIGHT SHALL BE REMOVED, UNLESS NOTED OTHERWISE. 12. ON NEW FLOOR PLANS: ALL ITEMS SHOWN IN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. ALL ITEMS SHOWN IN HEAVY LINE WEIGHT ARE NEW OR RELOCATED AS NOTED. 13. THE NEW WIRING REQUIRED IN REMODELED AREAS SHALL BE FISHED THROUGH EXISTING WALLS OR CONCEALED IN NEW WALLS OR ABOVE CEILINGS. SURFACE MOUNTED CONDUIT SHALL NOT BE USED IN ANY FINISHED AREAS. CONTRACTOR SHALL NOT ROUTE ANY CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS NOTED TO DO SO. 14. ITEMS THAT ARE SHOWN TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL ASSOCIATED CONDUIT, WIRE, AND HANGERS BACK TO THE POINT OF ORIGIN OR THE NEAREST EXISTING ITEM THAT IS REMAINING, UNLESS NOTED OTHERWISE. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH, AFTER CONDUCTORS HAVE BEEN REMOVED. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE. IF EXISTING CONDUITS ARE ROUTED IN CONCRETE FLOOR SLABS, WALLS OR CEILINGS, THEY SHALL BE CUT BACK TO WITHIN CONCRETE AND FILLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. 15. MAINTAIN CIRCUIT CONTINUITY FOR EXISTING ITEMS THAT ARE REMAINING OR BEING RELOCATED. 16. ELECTRICAL DEVICE IDENTIFICATION LABELS: PROVIDE ADHESIVE FILM LABEL, MACHINE PRINTED, IN BLACK, BY THERMAL TRANSFER OR EQUIVALENT PROCESS WITH MINIMUM LETTER HEIGHT OF 3/8" ON ALL ELECTRICAL DEVICES. LABEL SHALL IDENTIFY ORIGINATING PANEL AND CIRCUIT NUMBER IN THE FOLLOWING FORMAT: PANEL-CKT. REFERENCE SPECIFICATIONS FOR ADDITIONAL LABELING REQUIREMENTS. WHERE THE PROJECT SPECIFICATIONS INDICATE MORE STRINGENT LABELING REQUIREMENTS, THOSE REQUIREMENTS SHALL TAKE PRECEDENCE. 17. PROVIDE TYPED UPDATED PANEL DIRECTORIES FOR EXISTING PANELS AFFECTED BY REMODEL WORK. PROVIDE NEW CIRCUIT BREAKER NUMBER IDENTIFICATION AS REQUIRED. DATE PROJECT NO. DATE DRAWN BY CHECKED BY ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 SCHEMATIC WIRING GRAPHICS THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. JORDAN TECHNICAL POWER 1. SA-1527 JORDAN TECHNICAL CENTER ELECTRICAL LEGEND CONSULTING ENGINEERS, INC. ARE NOT NECESSARILY USED. REVISION/ISSUE SA-1227 FEBRUARY 2 2016 LDF GMG SHEET DESCRIPTION ELECTRICAL COVER SHEET 11/9/2015 4:39:56 PM SHEET NUMBER ELECTRICAL COVER SHEET SCALE: NO SCALE 1 E0.00 FLAG NOTES THIS SHEET: 1. ALL EXISTING ELECTRICAL GEAR IN THIS ROOM TO REMAIN. 2. REMOVE CONNECTION TO UNIT HEATER BACK TO SERVING SOURCE OR NEAREST REMAINING DEVICE. 3. REMOVE CONNECTION TO EXHAUST FAN BACK TO SERVING SOURCE OR NEAREST REMAINING DEVICE. 4. EXISTING GREENHOUSE CONTROLS TO REMAIN 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com CONSULTING ENGINEERS, INC. LCP "L3" "L2B" "L2" "L10" 1 "L1" "T1" LCA "H2" "T2" "H1" LCP "L4" 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com UH-1 UH-6 2 2/2/2016 2 4 GS-1 GS-1 GS-1 GS-1 GS-1 GS-1 GS-1 GS-1 GEF-2 WP GS-1 GS-1 GS-1 WP GEF-1 GEF-1 GEF-1 GEF-2 2 2 S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt UH-2 UH-5 WP WP DATE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 GS-1 JORDAN TECHNICAL SA-1527 JORDAN TECHNICAL CENTER WP REVISION/ISSUE GEF-2 WP WP PROJECT NO. 2 SA-1227 2 DATE UH-4 UH-3 EF-5 EF-6 WP GEF-2 GEF-2 FEBRUARY 2 2016 DRAWN BY CHECKED BY LDF GMG SHEET DESCRIPTION 3 3 DEMO ELECTRICAL PLAN 11/9/2015 4:39:56 PM SHEET NUMBER ELECTRICAL DEMO FLOOR PLAN SCALE: 3/32" = 1' 1 E1.01 GENERAL NOTES: A. PROVIDE NEW COVERS FOR EXISTING GFI, WP RECEPTACLES WHERE NEEDED. 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com FLAG NOTES (THIS SHEET): 1. EXHAUST FAN LOCATED ON ROOF ABOVE. 2. NEW COMBINATION VFD/DISCONNECT FOR CONNECTION TO EVAPORATIVE COOLER; VFD FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. TO BE LOCKABLE IN THE OPEN POSITION. 3. PROVIDE HUBBEL HBL45123R-HBLP0B1D-5221,52CM21 CORD REEL ASSEMBLY OR APPROVED EQUIVALENT. NEMA 4X RATED REEL ENCLOSURE WITH 45' S.O. CORD AND WP, GFI DUPLEX RECEPTACLE. 4. PROVIDE DEDICATED 20A, WP, GFI RECEPTACLE FOR CONNECTION TO GROW BED HEATING SYSTEM, TYPICAL OF (6). 5. NEW COMBINATION VFD/DISCONNECT FOR CONNECTION TO EXHAUST FAN; VFD FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. TO BE LOCKABLE IN THE OPEN POSITION. "L3" "L2B" L4-23 5 L4-25 L4-27 L4-29 L4-31 L4-33 4 TYP. 2/2/2016 5 EF-2 H1-(21,23,25) EF-1 H1-(15,17,19) WP WP WP WP WP WP WP UH-2 L10-31 (PART) WP UH-1 L10-31 (PART) WP L10-39 WP CF-1 L4-41 (PART) CF-1 L4-41 (PART) CF-1 L4-39 (PART) CF-1 L4-39 (PART) WP L10-41 L10-32 3 3 WP WP UH-4 L10-33 (PART) UH-3 L10-33 (PART) WP CF-1 L4-37 (PART) CF-1 L4-37 (PART) WP CF-1 L4-35 (PART) CF-1 L4-35 (PART) L10-34 DATE L10-36 3 ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 3 L10-37 JORDAN TECHNICAL WP 3 S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com SA-1527 JORDAN TECHNICAL CENTER "L2" "L10" LCP "L1" "T1" LCA "H2" "T2" "H1" LCP "L4" 1 CONSULTING ENGINEERS, INC. REVISION/ISSUE 3 WP WP UH-6 L10-35 (PART) WP WP UH-5 L10-35 (PART) CF-1 L4-34 (PART) CF-1 L4-34 (PART) PROJECT NO. DATE WP L10-38 (PART) WP EC-1 H2-(17,19,21) 2 EC-2 H2-(8,10,12) 2 2 SA-1227 FEBRUARY 2 2016 EC-3 H2-(14,16,18) DRAWN BY L10-38 (PART) CHECKED BY LDF GMG SHEET DESCRIPTION WP NEW ELECTRICAL PLAN 11/9/2015 4:39:56 PM SHEET NUMBER ELECTRICAL FLOOR PLAN SCALE: 3/32" = 1' 1 E2.01 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com CONSULTING ENGINEERS, INC. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com DATE PROJECT NO. DATE ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 JORDAN TECHNICAL S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt SA-1527 JORDAN TECHNICAL CENTER 2/2/2016 REVISION/ISSUE SA-1227 FEBRUARY 2 2016 DRAWN BY CHECKED BY LDF GMG SHEET DESCRIPTION ELECTRICAL ONE-LINE AND SCHEDULES 11/9/2015 4:39:56 PM SHEET NUMBER ELECTRICAL DETAILS SCALE: NO SCALE 1 E3.01 DIVISION 16 - ELECTRICAL SPECIFICATION SECTION 16070 - HANGERS AND SUPPORTS 4. FLEXIBLE METAL CONDUIT SHALL BE UTILIZED FOR ALL CONNECTIONS TO VIBRATING EQUIPMENT SUCH AS MOTORS (MINIMUM OF 2'-0", MAXIMUM OF 6'-0"), CONNECTIONS TO LAY-IN TYPE LIGHT FIXTURES OR IN REMODEL AREAS SPECIFICALLY NOTED FOR "FISHING" IN EXISTING WALLS OR NON-ACCESSIBLE CEILINGS. MINIMUM SIZE 3/4" EXCLUDING FIXTURE WHIPS FOR WHICH MINIMUM SIZE ALLOWED IS 1/2". 5. RIGID NONMETALLIC CONDUIT (PVC) SHALL BE UTILIZED FOR ABOVE AND BELOW GRADE APPLICATIONS IN ACCORDANCE WITH ARTICLE 352 OF THE NATIONAL ELECTRIC CODE. CONNECTIONS TO BE MADE BY THE USE OF A SUITABLE SOLVENT-TYPE CEMENT. 6. SURFACE METALLIC RACEWAYS SHALL BE LIMITED TO ONLY AREAS SPECIFICALLY NOTED AND OF SIZE AND TYPE SPECIFIED ON THE DRAWINGS. 7. ALL CONDUITS EXPOSED OR CONCEALED SHALL BE ROUTED PARALLEL OR PERPENDICULAR WITH THE BUILDING WALLS. SUPPORT CONDUIT AS REQUIRED BY THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. 8. PROVIDE EXPANSION TYPE FITTINGS FOR ALL CONDUITS, WHICH CROSS EXPANSION JOINTS. 9. LIQUID TIGHT FLEXIBLE METAL CONDUIT REQUIRED FOR ALL WET OR DAMP LOCATIONS. SECTION 16010 - BASIC ELECTRICAL REQUIREMENTS. 1. PROVIDE HANGERS AND SUPPORTS FOR EQUIPMENT, RACEWAYS AND CABLES, INCLUDING WEIGHT OF WIRE IN RACEWAYS. ALL SYSTEMS CABLING SHALL BE SUPPORTED BY BRIDAL RINGS OR SIMILAR MEANS. 2. USE HOT-DIPPED GALVANIZED MATERIAL OR NONMETALLIC, U-CHANNEL SYSTEMS FOR ALL DAMP AND OUTDOOR LOCATIONS. 3. STEEL MATERIAL SHALL BE USED FOR DRY LOCATIONS. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS FOR COMPLETION OF ALL ELECTRICAL SYSTEMS DESCRIBED HERE IN. ALL ELECTRICAL EQUIPMENT AND MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS, GOVERNING AUTHORITIES, AND IN A NEAT AND WORKMEN LIKE MANNER BY SKILLED AND COMPETENT ELECTRICIANS IN CONFORMANCE WITH THE STANDARD PRACTICES OF THE ELECTRICAL INDUSTRY. ALL ELECTRICAL SYSTEMS SHALL BE COMPLETE AND OPERATIONAL TO THE BENEFIT OF THE OWNER. A. GOOD WORKMANSHIP AND APPEARANCE ARE CONSIDERED EQUAL TO PROPER OPERATION. SECTION 16075 - ELECTRICAL IDENTIFICATION B. THE CONTRACTOR SHALL PROVIDE ALL FORSEEABLE ELECTRICAL EQUIPMENT AND ACCESSORIES NECESSARY, WHETHER SPECIFICALLY STATED OR NOT, TO MAKE THE REQUIRED ELECTRICAL SYSTEMS COMPLETE AND OPERATIONAL. 1. PROVIDE LABELING FOR RACEWAYS AND CABLES. 2. COLOR CODING OF PHASE CONDUCTORS: A. B. B. C. D. 277/480 VOLTS PHASE A: PHASE B: PHASE C: NEUTRAL: GROUND: TRAVELERS: "PROVIDE" MEANS CONTRACTOR IS RESPONSIBLE FOR THE FURNISHING AND INSTALLATION OF. "EXPOSED" MEANS WHERE IT CAN BE SEEN AFTER THE BUILDING IS COMPLETED SUCH AS IN EQUIPMENT ROOMS, UNFINISHED AREAS, ACCESSIBLE TUNNELS, ETC. WHERE CONDUIT/EQUIPMENT IS ACCESSIBLE. "CONCEALED" MEANS WHERE IT CANNOT BE SEEN AFTER THE BUILDING IS COMPLETED SUCH AS IN SPACES AS CHASES, TRENCHES, ABOVE CEILINGS, IN WALLS AND BURIED WHERE CONDUIT/WIRE IS INACCESSIBLE WHEN BUILDING IS COMPLETED. STANDARDS FOR MATERIALS: ALL MATERIALS SHALL BE NEW EXCEPT AS OTHERWISE STATED, AND SHALL CONFORM WITH THE CURRENT APPLICABLE INDUSTRY STANDARDS, NEMA STANDARDS AND UNDERWRITERS' LABORATORIES STANDARDS. 4. COORDINATE AND ORDER THE PROGRESS OF ELECTRICAL WORK TO CONFORM TO THE OWNER'S SCHEDULE AND THE PROGRESS OF THE WORK OF THE OTHER TRADES. 5. APPLY FOR AND PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS DIVISION OF WORK. 6. PROVIDE TEMPORARY LIGHTING AND POWER AS REQUIRED. 7. VISIT THE PROJECT BEFORE SUBMITTING A BID AS NO EXTRAS WILL BE ALLOWED FOR LACK OF KNOWLEDGE OF OBVIOUS EXISTING CONDITIONS. 8. DRAWINGS ARE DIAGRAMMATIC IN NATURE. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK. COMPLY WITH THE LATEST FEDERAL, STATE AND LOCAL CODES REQUIREMENTS, AND ORDINANCES, WITH THE NATIONAL ELECTRICAL CODE OF THE NATIONAL FIRE PROTECTION ASSOCIATION, AND WITH REQUIREMENTS OF THE POWER AND TELEPHONE COMPANIES FURNISHING SERVICES TO THE PROJECT. THE FOLLOWING IS A BRIEF LIST OF APPLICABLE CODES: A. NFPA NO. 70 - NATIONAL ELECTRICAL CODE, LATEST EDITION B. NFPA NO. 72 - FIRE ALARM, LATEST EDITION C. NFPA NO. 101 - LIFE SAFETY CODE, LATEST EDITION D. IBC & UBC, LATEST EDITION E. LOCAL BUILDING CODES, LATEST EDITION 10. ALL EQUIPMENT AND MATERIALS SHALL BE NEW UNLESS NOTED OTHERWISE AND ACCEPTABLE FOR INSTALLATION ONLY IF LABELED OR LISTED AS DEFINED IN NFPA 70, ARTICLE 100, BY UL OR BY A RECOGNIZED TESTING LABORATORY WHERE STANDARDS HAVE BEEN ESTABLISHED AND ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. LABELED OR LISTED EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ANY INSTRUCTIONS OR LABELING PROVIDED WITH THE EQUIPMENT. 1. 2. 3. 4. S:\Current Jobs\SA-1527 JTC Green House - Jordan School District\CD's\Architectural\Revit\SA-1527 Jordan Technical Center 11-6-2015.rvt COORDINATE UG SITE UTILITIES WITH APPROPRIATE UTILITY COMPANY PRIOR TO WORK. 14. PRODUCT ALTERATIONS AND SUBSTITUTIONS: SHOULD THE CONTRACTOR WISH TO HAVE PRODUCTS CONSIDERED OTHER THAN THOSE SPECIFIED, CONTRACTOR MUST SUBMIT THOSE ITEMS AS REQUIRED IN DIVISION 1. CONTRACTOR WILL BE REQUIRED TO SUBMIT THE TOTAL SAVINGS (ANTICIPATED SAVINGS) TO THE OWNER. 15. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS AS REQUIRED IN DIVISION 1 FOR ALL MATERIALS AND EQUIPMENT. IF THE SHOP DRAWINGS DEVIATE FROM THE CONTRACT DOCUMENTS ADVISE THE ENGINEER OF THE DEVIATIONS VIA WRITTEN FORMAT, ACCOMPANYING THE SHOP DRAWINGS. INCLUDE THE REASON FOR THE DEVIATION(S). COORDINATE ALL REQUIRED CHANGES WITH THE OTHER TRADES AFFECTED. IF THE CHANGES ARE OCCASIONED BY THE CONTRACTOR, THE CONTRACTOR SHALL PAY ANY COSTS INVOLVED. SHOP DRAWINGS SHALL INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: A. B. C. D. E. F. G. H. PROVIDE TESTING OF ALL ELECTRICAL SYSTEMS AND COMPONENTS AS REQUIRED BY ALL APPLICABLE BUILDING CODES AND ORDINANCES, UL, NEMA, ANSI, ICEA, NECA, ETC., AND AS RECOMMENDED BY THE ELECTRICAL EQUIPMENT MANUFACTURERS. FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND INCLUDE AN ALLOWANCE FOR THE REMOVAL AND RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEMS TO ALL OTHER WORK REQUIRED ON THIS PROJECT. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE END RESULT AS INDICATED ON THE DRAWINGS. WHERE THE REUSE OF EXISTING CONDUITS, OUTLETS, JUNCTION BOXES, ETC., IS PERMISSIBLE, MAKE CERTAIN THAT THE WIRING FOR THEM IS CONTINUOUS FROM OUTLET TO OUTLET AND THAT ALL SPLICES AND INSULATIONS ARE IN GOOD CONDITION. PROVIDE MODIFICATIONS TO ASSURE THAT CIRCUITS, OR SYSTEM SHALL NOT PASS THROUGH OUTLETS OR JUNCTION BOXES WHICH MAY BE RENDERED INACCESSIBLE BY CHANGES TO BE MADE TO THE PROJECT. EXISTING CONDUITS, WIRE, DEVICES, ETC., WHICH SHALL BE REMOVED SHALL BECOME THE PROPERTY OF THE OWNER UNLESS OTHERWISE NOTED. CONNECT NEW WORK TO EXISTING IN A MANNER THAT WILL ASSURE PROPER RACEWAY GROUNDING THROUGHOUT IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE. REMODEL WORK, CUTTING AND PATCHING: THIS CONTRACTOR SHALL PERFORM ALL CUTTING, CHANNELING, CHASING, DRILLING, ETC., AS REQUIRED TO INSTALL OR REMOVE ELECTRICAL EQUIPMENT IN AREAS OF REMODELING. THIS WORK SHALL BE PERFORMED SO AS TO MINIMIZE DAMAGE TO PORTIONS OF WALL FINISHES, SURFACES, PLASTERING, OR THE STRUCTURES WHICH ARE TO BE REUSED, RESURFACED, PLASTERED, OR PAINTED UNDER OTHER DIVISIONS OF THESE SPECIFICATIONS. A. CONNECTIONS SHALL BE EITHER BOLTED-PRESSURE-TYPE, COMPRESSION TYPE OR EXOTHERMIC-WELDED TYPE. 2. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR IN ALL FEEDER AND BRANCH CIRCUITS AND ALL FLEXIBLE AND NONMETALLIC RACEWAYS. 3. GROUNDING CONDUCTOR MATERIAL: COPPER. B. OUTLET BOXES SHALL BE LOCATED SO THAT TRANSMISSION OF SOUND TRHOUGH COMMON WALLS WILL NOT OCCUR. C. ENCLOSURES EXPOSED TO WEATHER OR DAMP LOCATIONS SHALL BE WEATHERPROOF TYPE. 2. PROVIDE COVERS SET TO COME FLUSH WITH FINISHED WALLS. 3. PULL BOXES AND JUNCTION BOXES: JUNCTION BOXES AND PULL BOXES WILL BE PROVIDED AS REQUIRED. SIZE OF BOXES SHALL BE IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE REQUIREMENTS. A. 7600 East Orchard Rd. #250S Greenwood Village, CO 80111 Phone: 303.796.6000 Fax: 303.796.6098 www.mkkeng.com ENCLOSURES SHALL BE NEMA TYPE SUITABLE FOR THE SURROUNDING AREA AND CONDITIONS. SECTION 16140 - WIRING DEVICES 1. RECEPTACLES SHALL BE 20 AMP HUBBELL HBL5352 SERIES SPECIFICATION GRADE, OR ACCEPTABLE. GFI AND EXTERIOR RECEPTACLES SHALL BE HUBBELL GF5352 SERIES, OR ACCEPTABLE AND IF REQUIRED PROVIDE WP IN USE METAL TYPE COVER, OR ACCEPTABLE. PROVIDE DEVICE COLOR AS DIRECTED BY THE ARCHITECT, OR TO MATCH BASE BUILDING STANDARDS, WHICHEVER IS APPLICABLE. 2. PROVIDE SPECIAL PURPOSE OUTLETS AS REQUIRED FOR EQUIPMENT PROVIDED BY OTHERS. 3. DEVICE PLATES SHALL BE HIGH ABUSIVE NYLON, COLOR TO MATCH DEVICE, OR TO MATCH BASE BUILDING STANDARDS, WHICHEVER IS APPLICABLE. 4. MOUNT DEVICES IN ACCORDANCE WITH THE FOLLOWING SCHEDULE EXCEPT WHERE OTHERWISE NOTED ON THE DRAWINGS OR IN AREAS WITH COUNTERS, BASEBOARD HEATERS OR IN AREAS OF BLOCK OR BRICK CONSTRUCTION: * EXCEPT IN AREAS WITH COUNTERS, BASEBOARD HEATERS, OR IN AREAS OF BLOCK OR BRICK CONSTRUCTION. SECTION 16180 - EQUIPMENT WIRING SYSTEMS 2. PROVIDE SAFETY SWITCHES AND/OR THERMAL OVERLOAD SWITCHES AS REQUIRED. 3. HEATER UNITS IN ALL MOTOR STARTERS SHALL BE SIZED FOR APPROXIMATELY ONE HUNDRED FIFTEEN PERCENT (115%) OF FULL LOAD MOTOR CURRENT. CHECK AND COORDINATE ALL THERMAL PROTECTIVE DEVICES WITH THE EQUIPMENT THEY PROTECT. 4. PROVIDE FOR EACH MOTOR, ONE-HALF (1/2) HORSEPOWER AND BELOW, A HORSEPOWER RATED DISCONNECT SWITCH AND THERMAL OVERLOAD PROTECTION UNLESS INTERNALLY PROVIDED WITH THE MOTOR. THERMAL OVERLOAD SWITCHES FOR SINGLE PHASE MOTORS SHALL BE ALLEN-BRADLEY BULLETIN 600 OR ACCEPTABLE. 5. CAREFULLY COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER APPLICABLE DIVISIONS. SECTION 16120 - CONDUCTORS AND CABLES 600-V AND LESS MINIMUM SIZE NO. 12 EXCEPT FOR CONTROL OR SIGNAL CIRCUITS, WHICH MAY BE NO. 14 OR SMALLER. INCREASE CONDUCTOR SIZE AS NECESSARY TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3 PERCENT AND SERVICE/FEEDER VOLTAGE DROP TO 2 PERCENT. ALL WIRING SHALL BE AS FOLLOWS: A. BRANCH CIRCUITS CONCEALED IN CEILINGS, WALLS, AND PARTITIONS, AND CONCEALED IN CONCRETE OR BELOW SLABS-ON-GRADE: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY. B. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS: TYPE SO, HARD SERVICE CORD. C. CLASS 1 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY. D. CLASS 2 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY OR POWER-LIMITED CABLE, CONCEALED IN BUILDING FINISHES. SECTION 16410 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS 1. SWITCH AND FUSE UNITS SHALL BE COMPLETE WITH REJECTION TYPE FUSES, DEAD FRONT WHEN CLOSED, WITH FUSES INACCESSIBLE UNTIL COMPLETELY CLEARED FROM CONTACT WITH THE MAINS. SWITCHES SHALL BE HEAVY DUTY, HORSEPOWER RATED AND SHALL HAVE QUICK-MAKE AND QUICK-BREAK MECHANISM, WITH EXTERNAL OPERATING HANDLE, AND INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. 2. CIRCUIT BREAKERS SHALL BE MOLDED-CASE, THERMAL-MAGNETIC TYPE, WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. CIRCUIT BREAKERS RATED 250 AMPS AND LARGER SHALL HAVE ADJUSTABLE MAGNETIC TRIP SETTING. 3. ALL CONDUCTORS SHALL BE COPPER; SOLID CONDUCTOR FOR NO.12 AWG AND SMALLER, STRANDED FOR NO. 10 AWG AND LARGER. 4. SPLICES FOR NO. 6 AWG AND SMALLER SHALL BE MADE WITH TWIST-ON WIRE CONNECTORS. 5. SPLICES FOR NO. 4 AWG AND LARGER SHALL BE MADE WITH SOLDERLESS OR COMPRESSION TYPE CU/ALR LUGS. 3. ENCLOSURES: NEMA TYPE SUITABLE FOR THE SURROUNDING AREA AND CONDITIONS. 6. WIRING FOR CONTROL SYSTEMS SHALL BE INSTALLED IN CONJUNCTION WITH MECHANICAL AND MISCELLANEOUS EQUIPMENT. 4. 7. INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 6 INCHES OF SLACK TO ALLOW FOR CONNECTION TO DEVICE. ENCLOSED SWITCHES AND CIRCUIT BREAKERS SHALL BE AS MANUFACTURED BY EATON CORP.; CUTLER-HAMMER, GENERAL ELECTRIC CO., SIEMENS ENERGY AND AUTOMATION, INC., OR SQUARE D CO. MANUFACTURER OF SWITCHES AND CIRCUIT BREAKERS SHALL BE SAME AS PANELBOARDS. 8. TESTING: PERFORM THE FOLLOWING FIELD QUALITY-CONTROL TESTING: 5. PROVIDE ENCLOSED SWITCHES FOR MOTOR OVERCURRENT PROTECTION, AND PROVIDE ENCLOSED SWITCHES OR CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION OF ALL OTHER EQUIPMENT AS REQUIRED BY THE CURRENT ISSUE OF THE NATIONAL ELECTRICAL CODE. A. TORQUE TEST CONDUCTOR CONNECTIONS AND TERMINATIONS TO MANUFACTURER'S RECOMMENDED VALUES. B. PERFORM CONTINUITY TEST ON ALL POWER AND EQUIPMENT BRANCH CIRCUIT CONDUCTORS. VERIFY PROPER PHASING CONNECTIONS. C. INSULATION TEST: MEASURE THE INSULATION OF FEEDER CONDUCTORS. MEASUREMENTS SHALL BE TAKEN BETWEEN CONDUCTORS, AND CONDUCTORS AND GROUND. RESISTANCE SHALL BE 1,000,000 OHMS OR MORE WHEN TESTED AT 500 VOLTS BY MEGGER WITHOUT CIRCUIT LOADS. 2/2/2016 CONVENIENCE RECEPTACLES: LONG AXIS VERTICAL AT 1'-6" AFF TO CENTER * ALL OUTAGES ON PORTIONS OF EXISTING ELECTRICAL SYSTEMS SHALL BE MINIMIZED AND SHALL BE AT A TIME AND OF A DURATION AS ACCEPTED BY THE OWNER. DATE 1. 1. LOW-VOLTAGE FUSES: DUAL-ELEMENT FUSES ACCURATELY RATED, OF THE CORRECT VOLTAGE AND CAPACITY TO PROTECT THE EQUIPMENT OR CIRCUITS SHALL BE PROVIDED. ALL FUSES SHALL BE PROPERLY COORDINATED AND SHALL BE OF THE SAME MANUFACTURER. ONE SET OF SPARE FUSES FOR EACH SIZE SHALL BE PROVIDED. 2. FUSES SHALL BE AS MANUFACTURED BY BUSSMANN REJECTION TYPE "FUSETRON" OR APPROVED EQUAL. CONTROL FUSES SHALL BE BUSSMANN ONE-TIME NONRENEWABLE. PROJECT NO. ALL CONDUCTORS SHALL BE ENCLOSED BY CONDUIT SIZED IN ACCORDANCE WITH CHAPTER 9, TABLE 4 OF THE NATIONAL ELECTRICAL CODE. MINIMUM SIZE 3/4 INCH. ALL CONDUITS SHALL BE CONCEALED IN FINISHED AREAS. 3. 3. GALVANIZED RIGID METAL CONDUIT (RMC) AND INTERMEDIATE METAL CONDUIT (IMC) SHALL BE UTILIZED FOR ABOVE AND BELOW GRADE APPLICATIONS IN ACCORDANCE WITH ARTICLES 344 AND 342 OF THE NATIONAL ELECTRICAL CODE. ALL COUPLINGS SHALL BE THREADED. REVISION/ISSUE SECTION 16491 - FUSES SECTION 16130 - RACEWAYS 2. CONDUIT SYSTEMS, SUPPORTS, CABINETS, EQUIPMENT, TRANSFORMERS, FIXTURES, THE GROUNDED CIRCUIT CONDUCTOR, ETC. SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE CURRENT ISSUE OF THE NATIONAL ELECTRICAL CODE. PROVIDE ALL BONDING JUMPERS AND WIRE, GROUNDING BUSHINGS, CLAMPS, ETC. AS REQUIRED FOR COMPLETE GROUNDING. FOUR INCH SQUARE OR OCTAGONAL, ZINC-COATED SHEET STEEL TYPE. 6. SECTION 16060 - GROUNDING AND BONDING 1. A. PROVIDE BRANCH CIRCUITS TO EQUIPMENT PROVIDED BY OTHERS AND TO MECHANICAL EQUIPMENT AND MAKE ALL CONNECTIONS. TEMPERATURE CONTROL EQUIPMENT WIRING AND CONNECTIONS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. PRODUCT DATA FOR ELECTRICAL IDENTIFICATION. PRODUCT DATA FOR BOXES, ENCLOSURES AND CABINETS. PRODUCT DATA FOR WIRING DEVICES. PRODUCT DATA FOR EQUIPMENT WIRING SYSTEMS. PRODUCT DATA AND DRAWINGS FOR ENCLOSED SWITCHES AND CIRCUIT BREAKERS. PRODUCT DATA FOR FUSES. TEST REPORTS AS REQUIRED. CERTIFICATES OF OPERATION AS REQUIRED. 16. PROJECT RECORD DRAWINGS: AT COMPLETION OF WORK, DELIVER COMPLETED PROJECT RECORD DOCUMENTS TO ARCHITECT/ENGINEER. PROJECT RECORD DOCUMENTS SHALL BE IN CADD AND SHALL INCLUDE ANY SPECIAL SYSTEMS (FIRE ALARM, ETC.) AND "PROJECT RECORD" SHOP DRAWINGS. CONSULTING ENGINEERS, INC. OUTLET BOXES: 1. 12. MAKE PROVISIONS FOR SAFE DELIVERY AND SECURE STORAGE OF ALL MATERIALS. 13. WARRANTIES: PROVIDE A WRITTEN WARRANTY TO THE OWNER COVERING THE ENTIRE ELECTRICAL WORK EXCLUDING INCANDESCENT AND FLUORESCENT LAMPS, TO BE FREE FROM DEFECTIVE MATERIALS, EQUIPMENT AND WORKMANSHIP FOR A PERIOD OF ONE YEAR AFTER DATE OF ACCEPTANCE. ALL DEFECTIVE EQUIPMENT OR MATERIALS WHICH APPEAR DURING THE WARRANTY PERIOD SHALL BE REPLACED OR REPAIRED BY THE ELECTRICAL CONTRACTOR IN A TIMELY FASHION AT NO COST TO THE OWNER. 1. CAREFULLY COORDINATE WITH THE REQUIRED REMODELING WORK, CUTTING AND PATCHING ETC., PERFORMED BY OTHER TRADES. REMOVE OR RELOCATE EXISTING ELECTRICAL CONDUITS, WIRES, DEVICES, FIXTURES AND OTHER EQUIPMENT AS NECESSARY. 2. B. SECTION 16137 - BOXES, ENCLOSURES AND CABINETS BLACK RED BLUE WHITE GREEN PINK 5. 1. COORDINATE CORE DRILL LOCATIONS WITH STRUCTURAL PRIOR TO WORK. 120/208 VOLTS PHASE A: PHASE B: PHASE C: NEUTRAL: GROUND: TRAVELERS: SECTION 16095 - DEMOLITION FOR REMODELING 11. PROVIDE ALL CORE DRILLING, CHANNELING, CUTTING, PATCHING, SLEEVES, ETC. AS REQUIRED FOR INSTALLATION OF ELECTRICAL EQUIPMENT. SEAL HOLES, FIREPROOFING WHERE NECESSARY, AND REFINISH ALL REPAIR WORK TO ORIGINAL CONDITION WHERE DAMAGED BY ELECTRICAL WORK. A. BROWN ORANGE YELLOW GRAY GREEN PURPLE SECTION 16080 - ELECTRICAL TESTING 1. 11/9/2015 4:39:56 PM WIRING FOR CONTROL SYSTEMS SHALL BE COLOR-CODED IN ACCORDANCE WITH THE WIRING DIAGRAMS FURNISHED WITH THE EQUIPMENT. DEFINITIONS AND STANDARDS: A. 9. CONDUCTORS NO. 8 AWG AND SMALLER SHALL BE FACTORY COLOR CODED. WIRE NO. 6 AWG AND LARGER MAY BE COLOR CODED BY FIELD PAINTING OR COLOR TAPING A 6-INCH LENGTH OF EXPOSED END. ENTER ADDRESS HERE 845 SOUTH 220 EAST OREM, UTAH 84058 3. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE GENERAL CONDITIONS, SUPPLEMENTAL GENERAL CONDITIONS OF THE PROJECT SPECIFICATIONS, ANY BASE BUILDING SPECIFICATIONS AND BUILDING CRITERIA, AND ALL CONTRACT SPECIFICATIONS AND DOCUMENTS. JORDAN TECHNICAL 2. 845 South 220 East Orem, UT 84058 Phone: 801.229.0088 Fax: 801.229.0089 www.sandstromarchitecture.com SA-1527 JORDAN TECHNICAL CENTER 1. DATE FEBRUARY 2 2016 DRAWN BY SPARE FUSE CABINET: IF REQUIRED, WALL MOUNT SIZE AS REQUIRED FOR STORAGE OF SPARE FUSES SPECIFIED WITH 15 PERCENT SPARE CAPACITY. SA-1227 CHECKED BY LDF GMG SHEET DESCRIPTION ELECTRICAL SPECIFICATIONS ELECTRICAL METALLIC TUBING (EMT) SHALL BE UTILIZED FOR ALL DRY, ABOVE GRADE OR ABOVE FLOOR FEEDERS AND BRANCH CIRCUIT HOMERUN APPLICATIONS IN ACCORDANCE WITH ARTICLE 358 OF THE NATIONAL ELECTRICAL CODE. COUPLINGS SHALL BE STEEL SET SCREW TYPE. SHEET NUMBER ELECTRICAL SPECIFICATIONS SCALE: NO SCALE 1 E4.01
© Copyright 2026 Paperzz