HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 www.hesinnovations.com Installation Instructions Folger Adam 310-6-1, -2, -3, -8, -30 Series Electric Strike Product Components 1 Electric Strike Body & Faceplate 2 #12-24 x 1/2” Mounting Screws 3 Plug In Connectors* *Only 1 Plug In Connector is used with 310-6-30 1 2 3 Electrical Specifications ELECTRICAL RATINGS FOR SOLENOID* MINIMUM WIRE GAUGE REQUIREMENTS 12VDC 24VDC 23.5 .51 SOLENOID VOLTAGE 12VDC 24VDC 96 200 feet or less .25 18 gauge 18 gauge 200 - 300 feet Solenoids are rated at +/- 10% indicated value. *Resistance value indicated above is per coil. 16 gauge 18 gauge 300 - 400 feet 14 gauge 16 gauge CONTINUOUS DUTY Resistance in Ohms Amps 1 Installation Directions 2 CAUTION! Before connecting any device at the installation site, verify input voltage using a multimeter. Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding 10% of the solenoid rating may cause severe damage to the unit and will void the warranty. Prepare Strike Finish Installing 1. If using the LCBMA (Latchbolt monitor & Locking Cam Monitor), see Diagram 1 for wiring instructions. 2. The strike body ships as either a 12 or 24 volt unit and is not field selectable. Verify the available voltage is +/- 10% of the rated voltage of the strike body. 4. Connect the Plug In Connector to the electric strike, and connect wires from the Plug In Connector leads to the power source. 5. Install the electric strike unit in jamb cutout, using the #12-24 x 1/2” mounting screws. Prepare Frame 3. Prepare frame using the template for your strike located on pages 3-7. Diagram 1: Monitoring Switches Latchbolt Monitor (LBM) White Orange Green Common Normally Open Normally Closed White Orange Green Locking Cam Monitor (LCM) Brown Blue Yellow Common Normally Open Normally Closed Brown Blue Yellow Cutout Templates 3 Inches [mm] 310-6-1 Template & Dimensions 6-15/16” [176.20] 4-3/4” [120.65] 6-15/16” [176.20] 4-3/4” [120.65] 4-3/8” [111.13] 1-3/8” [34.93] 1/8” [3.18] 1” [25.4] 11/16” 2” (Typ.) [17.45] [50.8] 1-1/4” [31.75] 14-1/2” [368.55] 13-7/8” [352.43] 5/16” [8.13] 13-25/64” [340.10] CL CL 13/16” [20.62] 1-5/8” [41.40] Reinforce jamb for tapped holes 10 gauge minimum [2 places] 1-3/8” [34.93] 14-1/2” [368.30] 5/8” [15.87] 1-3/4” [44.45] 5-1/16” [128.59] 1-5/8” [41.28] #16 Drill [.177] & tap 12-24 U.N.C. thru [5 places] Center line of electric strike & latchbolt of lock must align. 6-15/16” [176.20] 1-5/8” [41.28] 13/16” [20.64] 4-3/8” [111.13] 5-1/16” [128.59] 6-15/16” [176.20] 5/16” [7.94] 15/16” [23.81] 2-1/8” [53.98] Cutout Templates 4 Inches [mm] 310-6-2 Template & Dimensions 7-1/4” [184.15] 7-1/4” [184.15] 5” [127] 4-3/4” [120.65] 4-3/4” [120.65] 1-3/8” [34.93] 1/8” [3.18] 11/16” 2” (Typ.) [17.45] [50.8] 1” [25.4] 1-1/4” [31.75] 15-9/64” [384.56] 5/16” [8.13] 14-1/2” [368.30] 13-25/64” [340.10] CL CL 13/16” [20.62] 1-5/8” [41.40] Reinforce jamb for tapped holes 10 gauge minimum [2 places] 1-3/8” [34.93] 15-1/8” [384.18] 5/8” [15.87] 1-3/4” [44.45] 5-1/16” [128.59] 1-5/8” [41.28] #16 Drill [.177] & tap 12-24 U.N.C. thru [5 places] Center line of electric strike & latchbolt of lock must align. 7-1/4” [184.15] 1-5/8” [41.28] 13/16” [20.64] 5” [127] 5-1/16” [128.59] 7-1/4” [184.15] 5/16” [7.94] 15/16” [23.81] 2-1/8” [53.98] Cutout Templates 5 Inches [mm] 310-6-3 Template & Dimensions 7-9/16” [192.07] 7-9/16” [192.07] 5-5/8” [142.88] 4-3/4” [120.65] 4-3/4” [120.65] 1-3/8” [34.93] 1/8” [3.18] 11/16” 2” (Typ.) [17.45] [50.8] 1” [25.4] 1-1/4” [31.75] 15-25/64” [400.30] 5/16” [8.13] 15-1/8” [384.18] 13-25/64” [340.10] CL CL 13/16” [20.62] 1-5/8” [41.40] Reinforce jamb for tapped holes 10 gauge minimum [2 places] 1-3/8” [34.93] 15-3/4” [400.05] 5/8” [15.87] 1-3/4” [44.45] 5-1/16” [128.59] 1-5/8” [41.28] #16 Drill [.177] & tap 12-24 U.N.C. thru [5 places] Center line of electric strike & latchbolt of lock must align. 7-9/16” [192.07] 1-5/8” [41.28] 13/16” [20.64] 5-5/8” [142.88] 5-1/16” [128.59] 7-9/16” [192.07] 5/16” [7.94] 15/16” [23.81] 2-1/8” [53.98] Cutout Templates 6 Inches [mm] 310-6-8 Template & Dimensions 9” [228.60] 4-3/4” [120.65] 1-3/8” [34.93] 11/16” [17.45] 1/8” [3.18] 4-3/4” [120.65] 1-3/16” [30.23] 1” [25.4] 2” (Typ.) [50.8] 12” [304.8] 10-5/32” [258.06] 9-1/2” [241.3] 1/3” [8.38] 9” [228.6] CL 13/16” [20.62] 1-5/8” [41.40] #16 Drill [.177] & tap 12-24 U.N.C. thru [5 places] Center line of electric strike & latchbolt of lock must align. Reinforce jamb for tapped holes 10 gauge minimum [2 places] 5/8” [31.75] 1-3/4” [44.45] 1-3/8” [34.93] 1-5/8” [41.28] 5-1/16” [128.59] 4-3/4” [120.65] 15/16” [23.81] 10-1/8” [257.18] 4-3/4” [120.65] 1-3/4” [44.45] 13/16” [20.64] 5/16” [7.94] 2” [50.8] Cutout Templates 7 Inches [mm] 310-6-30 Template & Dimensions 6-1/4” [158.75] 6-1/4” [158.75] 3” [76.20] 4-3/4” [120.65] 4-3/4” [120.65] 1-3/8” [34.93] 1/8” [3.18] 11/16” 2” (Typ.) [17.45] [50.8] 1” [25.4] 1-1/4” [31.75] 13-1/8” [333.76] 12-1/2” [317.50] 5/16” [8.13] 13-25/64” [340.10] CL CL 13/16” [20.62] 1-5/8” [41.40] Reinforce jamb for tapped holes 10 gauge minimum [2 places] 1-3/8” [34.93] 13-1/8” [333.38] 5/8” [15.87] 1-3/4” [44.45] 5-1/16” [128.59] 1-5/8” [41.28] #16 Drill [.177] & tap 12-24 U.N.C. thru [5 places] Center line of electric strike & latchbolt of lock must align. 6-1/4” [158.75] 1-5/8” [41.28] 13/16” [20.64] 3” [76.20] 5-1/16” [128.59] 6-1/4” [158.75] 5/16” [7.94] 15/16” [23.81] 2-1/8” [53.98] Installation Directions 8 This page intentionally left blank. 3810006.004 rev A © 2010 HES, Inc.
© Copyright 2026 Paperzz