310-6-1 Install Instructions

HES, Inc.
22630 N. 17th Ave.
Phoenix, AZ 85027
800-626-7590
www.hesinnovations.com
Installation Instructions
Folger Adam 310-6-1, -2, -3, -8, -30 Series Electric Strike
Product Components
1
Electric Strike Body & Faceplate
2
#12-24 x 1/2” Mounting Screws
3
Plug In Connectors*
*Only 1 Plug In Connector is used with 310-6-30
1
2
3
Electrical Specifications
ELECTRICAL RATINGS FOR SOLENOID*
MINIMUM WIRE GAUGE REQUIREMENTS
12VDC
24VDC
23.5
.51
SOLENOID VOLTAGE
12VDC
24VDC
96
200 feet or less
.25
18 gauge
18 gauge
200 - 300 feet
Solenoids are rated at +/- 10% indicated value.
*Resistance value indicated above is per coil.
16 gauge
18 gauge
300 - 400 feet
14 gauge
16 gauge
CONTINUOUS DUTY
Resistance in Ohms
Amps
1
Installation Directions
2
CAUTION! Before connecting any device at the installation site, verify input voltage using a multimeter.
Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding
10% of the solenoid rating may cause severe damage to the unit and will void the warranty.
Prepare Strike
Finish Installing
1. If using the LCBMA (Latchbolt monitor & Locking Cam
Monitor), see Diagram 1 for wiring instructions.
2. The strike body ships as either a 12 or 24 volt
unit and is not field selectable. Verify the available
voltage is +/- 10% of the rated voltage of the strike body.
4. Connect the Plug In Connector to the electric strike, and
connect wires from the Plug In Connector leads to the
power source.
5. Install the electric strike unit in jamb cutout, using the
#12-24 x 1/2” mounting screws.
Prepare Frame
3. Prepare frame using the template for your strike
located on pages 3-7.
Diagram 1: Monitoring Switches
Latchbolt Monitor (LBM)
White
Orange
Green
Common
Normally Open
Normally Closed
White
Orange
Green
Locking Cam Monitor (LCM)
Brown
Blue
Yellow
Common
Normally Open
Normally Closed
Brown
Blue
Yellow
Cutout Templates
3
Inches [mm]
310-6-1 Template & Dimensions
6-15/16”
[176.20]
4-3/4”
[120.65]
6-15/16”
[176.20]
4-3/4”
[120.65]
4-3/8”
[111.13]
1-3/8”
[34.93]
1/8”
[3.18]
1”
[25.4]
11/16” 2” (Typ.)
[17.45] [50.8]
1-1/4”
[31.75]
14-1/2”
[368.55]
13-7/8”
[352.43]
5/16”
[8.13]
13-25/64”
[340.10]
CL
CL
13/16”
[20.62]
1-5/8”
[41.40]
Reinforce jamb
for tapped holes
10 gauge minimum
[2 places]
1-3/8”
[34.93]
14-1/2”
[368.30]
5/8”
[15.87]
1-3/4”
[44.45]
5-1/16”
[128.59]
1-5/8”
[41.28]
#16 Drill [.177] &
tap 12-24 U.N.C.
thru [5 places]
Center line of electric
strike & latchbolt of
lock must align.
6-15/16”
[176.20]
1-5/8”
[41.28]
13/16”
[20.64]
4-3/8”
[111.13]
5-1/16”
[128.59]
6-15/16”
[176.20]
5/16”
[7.94]
15/16”
[23.81]
2-1/8”
[53.98]
Cutout Templates
4
Inches [mm]
310-6-2 Template & Dimensions
7-1/4”
[184.15]
7-1/4”
[184.15]
5”
[127]
4-3/4”
[120.65]
4-3/4”
[120.65]
1-3/8”
[34.93]
1/8”
[3.18]
11/16” 2” (Typ.)
[17.45] [50.8]
1”
[25.4]
1-1/4”
[31.75]
15-9/64”
[384.56]
5/16”
[8.13]
14-1/2”
[368.30]
13-25/64”
[340.10]
CL
CL
13/16”
[20.62]
1-5/8”
[41.40]
Reinforce jamb
for tapped holes
10 gauge minimum
[2 places]
1-3/8”
[34.93]
15-1/8”
[384.18]
5/8”
[15.87]
1-3/4”
[44.45]
5-1/16”
[128.59]
1-5/8”
[41.28]
#16 Drill [.177] &
tap 12-24 U.N.C.
thru [5 places]
Center line of electric
strike & latchbolt of
lock must align.
7-1/4”
[184.15]
1-5/8”
[41.28]
13/16”
[20.64]
5”
[127]
5-1/16”
[128.59]
7-1/4”
[184.15]
5/16”
[7.94]
15/16”
[23.81]
2-1/8”
[53.98]
Cutout Templates
5
Inches [mm]
310-6-3 Template & Dimensions
7-9/16”
[192.07]
7-9/16”
[192.07]
5-5/8”
[142.88]
4-3/4”
[120.65]
4-3/4”
[120.65]
1-3/8”
[34.93]
1/8”
[3.18]
11/16” 2” (Typ.)
[17.45] [50.8]
1”
[25.4]
1-1/4”
[31.75]
15-25/64”
[400.30]
5/16”
[8.13]
15-1/8”
[384.18]
13-25/64”
[340.10]
CL
CL
13/16”
[20.62]
1-5/8”
[41.40]
Reinforce jamb
for tapped holes
10 gauge minimum
[2 places]
1-3/8”
[34.93]
15-3/4”
[400.05]
5/8”
[15.87]
1-3/4”
[44.45]
5-1/16”
[128.59]
1-5/8”
[41.28]
#16 Drill [.177] &
tap 12-24 U.N.C.
thru [5 places]
Center line of electric
strike & latchbolt of
lock must align.
7-9/16”
[192.07]
1-5/8”
[41.28]
13/16”
[20.64]
5-5/8”
[142.88]
5-1/16”
[128.59]
7-9/16”
[192.07]
5/16”
[7.94]
15/16”
[23.81]
2-1/8”
[53.98]
Cutout Templates
6
Inches [mm]
310-6-8 Template & Dimensions
9”
[228.60]
4-3/4”
[120.65]
1-3/8”
[34.93]
11/16”
[17.45]
1/8”
[3.18]
4-3/4”
[120.65]
1-3/16”
[30.23]
1”
[25.4]
2” (Typ.)
[50.8]
12”
[304.8]
10-5/32”
[258.06]
9-1/2”
[241.3]
1/3”
[8.38]
9”
[228.6]
CL
13/16”
[20.62]
1-5/8”
[41.40]
#16 Drill [.177] &
tap 12-24 U.N.C.
thru [5 places]
Center line of electric
strike & latchbolt of
lock must align.
Reinforce jamb for tapped
holes 10 gauge minimum
[2 places]
5/8”
[31.75]
1-3/4”
[44.45]
1-3/8”
[34.93]
1-5/8”
[41.28]
5-1/16”
[128.59]
4-3/4”
[120.65]
15/16”
[23.81]
10-1/8”
[257.18]
4-3/4”
[120.65]
1-3/4”
[44.45]
13/16”
[20.64]
5/16”
[7.94]
2”
[50.8]
Cutout Templates
7
Inches [mm]
310-6-30 Template & Dimensions
6-1/4”
[158.75]
6-1/4”
[158.75]
3”
[76.20]
4-3/4”
[120.65]
4-3/4”
[120.65]
1-3/8”
[34.93]
1/8”
[3.18]
11/16” 2” (Typ.)
[17.45] [50.8]
1”
[25.4]
1-1/4”
[31.75]
13-1/8”
[333.76]
12-1/2”
[317.50]
5/16”
[8.13]
13-25/64”
[340.10]
CL
CL
13/16”
[20.62]
1-5/8”
[41.40]
Reinforce jamb
for tapped holes
10 gauge minimum
[2 places]
1-3/8”
[34.93]
13-1/8”
[333.38]
5/8”
[15.87]
1-3/4”
[44.45]
5-1/16”
[128.59]
1-5/8”
[41.28]
#16 Drill [.177] &
tap 12-24 U.N.C.
thru [5 places]
Center line of electric
strike & latchbolt of
lock must align.
6-1/4”
[158.75]
1-5/8”
[41.28]
13/16”
[20.64]
3”
[76.20]
5-1/16”
[128.59]
6-1/4”
[158.75]
5/16”
[7.94]
15/16”
[23.81]
2-1/8”
[53.98]
Installation Directions
8
This page intentionally
left blank.
3810006.004 rev A
© 2010 HES, Inc.