PowerPak System Data Sheet Genelec 8030.LSE PowerPak™ Multi-Channel Monitoring System ronments, the LSE™ 7060A subwoofer Directivity Control Waveguide™ (DCW™), features a single 10” proprietary driver with effectively reducing diffraction and improving Continuing the tradition of providing well fac- a 120 Watt power amplifier, a frequency imaging. Powered by a pair of 40 Watt ampli- tored active monitoring products, Genelec response of 29 Hz to 85 Hz (120 Hz) +/-3 fiers, the Genelec 8030A monitors offer a introduces the 8030.LSE PowerPak™, a dB, and has the ability to deliver an SPL of wide frequency response of 58 Hz to 20 kHz new comprehensive multi-channel monitoring 108 dB at 1 meter. In addition, the 7060A (+/-2.0 dB) from a 5” woofer and 3/4” hard-domed system specifically designed for post-production boasts Genelec’s new 6.1 bass management tweeter. In addition to low harmonic distortion, suites and recording studios with control rooms system, which has six signal input and output the 8030A also offers rear panel bass and measuring less than 85 m3 (3000 cubic feet) (W channels (L/C/R Front and L/C/R Rear), as treble tilt room response controls. The MDE™ x D x H). The 8030.LSE PowerPak™ system is well as a discrete LFE signal input with a enclosure of the Genelec 8030A active moni- a perfectly tailored solution and simplifies the selectable 85/120 Hz low-pass filter and a tors is made of die cast aluminum, featuring process of creating a new multi-channel moni- summed signal output, providing flexibility and rugged construction while also providing effi- toring system or upgrading an existing stereo easy connection. cient heat dissipation capability and shielding monitoring environment to 5.1 surround. The built-in bass management unit splits the against RF interference. Each speaker is also The 8030.LSE PowerPak™ system consists six main channel input signals into low and high magnetically shielded for additional protection of five Genelec 8030A two-way, bi-amplified frequency components, accurately dividing the when used in close proximity to video monitors. active monitors, one Genelec 7060A LSE™ input signal between the subwoofer and main The Iso-Pod™ table stand delivered with each Series Active Subwoofer, and a Genelec speakers. A dedicated LFE In input connector 8030A has adjustable tilt so that the acoustical Acousti/Tape™ frequency/wavelength mea- enables easy set-up and accurate monitoring of axis can be pointed precisely towards the lis- suring tape. In addition, a Genelec 8030.LSE the LFE channel in 5.1 and 6.1 digital surround tener for best sound reproduction. The isolation PowerPak setup guide is included for accurate sound systems. feature prevents colouration caused by conduc- speaker placement, wiring and fine-tuning. The system also includes five Genelec tion of unwanted vibration to the mixing console The cornerstone of the system is Genelec’s 8030A two-way, bi-amplified active monitors. revolutionary 7060A LSE™ Series Active The 8030A is a compact close-field system The 8030.LSE PowerPak™ once properly Subwoofer which employs Genelec’s propri- featuring Genelec’s proprietary Minimum Dif- set up will provide an accurate and stable rep- etary Laminar Spiral Enclosure™ (LSE™) fraction Enclosure™ (MDE™). The rounded resentation of any multichannel audio signal, technology. Designed for multi-channel pro- corners and continuously curving forms of the yet its compact size makes it applicable to fessional surround sound monitoring envi- enclosure blend seamlessly into the improved almost any listening environment. or other mounting surface. 8030.LSE PowerPak™ Data Sheet SYSTEM SPECIFICATIONS Free field frequency response (+/- 3 dB) 7060A BASS MANAGEMENT SYSTEM 7060A 8030A 29 Hz…85 Hz (Main channels) 58 Hz...20 kHz Maximum short term sine wave averaged SPL output ≥ 108 dB SPL ≥ 100 dB SPL Maximum peak SPL output ≥ 113 dB SPL ≥ 106 dB SPL Self generated noise level in free field @ 1 m on axis (A-weighted) ≤ 15 dB ≤ 10 dB Harmonic distortion @ 95 dB SPL <2% @ 85 dB SPL < 2 % (50...150 Hz) < 0.5 % (> 150 Hz) Drivers (Magnetically shielded) 205 mm (10”) 7060A 130 mm (5”) woofer 19 mm (3/4”) dome tweeter Weight 26 kg (57 lbs) 5.6 kg (12.3 lbs) Dimensions Height Width Depth 527 mm (20 3/4”) 462 mm (18 316”) 360 mm (14 3/16”) 299 mm (11 13/16”)* 189 mm (7 7/16”) 178 mm (7”) *Including Iso-Pod™ table stand AMPLIFIER SECTION 7060A 8030A Short term amplifier output power (Long term output power is limited by driver unit protection circuitry) Bass Treble 120 W N/A 40 W 40 W Amplifier system distortion at nominal output THD ≤ 0.05 % ≤ 0.05 % 220, 230, 240, 100/200 or 115/230 V according to region 100, 120, 220 or 230 V according to region 15 VA 150 VA 10 VA 80 VA Mains voltage Power consumption (average) Idle Full output Subsonic filter (18 dB/octave) below 29 Hz Upper bandwidth/LFE cutoff 85 Hz/120 Hz selectable Connectors Input Output 7 XLR female (6 Main + 1 LFE) 7 XLR male (6 Main + 1 Sum Out) XLR pin sequence pin 1 gnd pin 2 + pin 3 - Input impedance 10 kOhm balanced Input level for 100 dB SPL output @ 1 m Variable from +6 to –12 dBu Crossover frequency, (sub/main channels) 85 Hz Crossover slopes Lowpass Highpass 36 dB/octave 12 dB/octave Midband rejection >400 Hz ≥ 50 dB Bass roll-off control operating range in 2 dB steps From 0 to –6 dB @ 30 Hz Phase matching control in 90° steps From 0 to 270° @ 85 Hz Bypass Bypasses the bass management for the main channels LFE sensitivity Adjustable 0 / +10 dB Redirect Redirects LFE channel signal above 85 Hz to center channel Sum In Changes subwoofer to Sum In mode, main inputs defeated Test tone for phase adjustment 85 Hz Remote LED connector (RJ11) Input for optional Power/Overload+Bypass remote controls 8030.LSE POWERPAK ACOUSTIC SPECIFICATIONS 8030.LSE PowerPak Recommended listening distance 1.7 to 2.5 m (5 to 8 ft) Typical max short term RMS SPL all channels driven 108 dB, Flat response weighting Suggested acoustic space max. 85 m3 (3000 cubic feet) www.genelec.com Genelec Document BBAGE030. Copyright Genelec Oy 1.2005. All data subject to change without prior notice International enquiries: In the U.S. please contact In China please contact: Genelec, Olvitie 5 Genelec, Inc., 7 Tech Circle Genelec China Representative Office FIN-74100, Iisalmi, Finland Natick, MA 01760 Soho New Town, 88 Jianguo Road Phone +358 17 83881 Phone 508 652 0900 D-1504, Chaoyang District Fax +358 17 812 267 Fax 508 652 0909 Beijing 100022, China Email [email protected] Email [email protected] Phone +86 10 8580 2180 Fax +86 10 8580 2181 Email [email protected]
© Copyright 2026 Paperzz