Powerpak datasheet.indd

PowerPak
System
Data Sheet
Genelec 8030.LSE PowerPak™
Multi-Channel Monitoring System
ronments, the LSE™ 7060A subwoofer
Directivity Control Waveguide™ (DCW™),
features a single 10” proprietary driver with
effectively reducing diffraction and improving
Continuing the tradition of providing well fac-
a 120 Watt power amplifier, a frequency
imaging. Powered by a pair of 40 Watt ampli-
tored active monitoring products, Genelec
response of 29 Hz to 85 Hz (120 Hz) +/-3
fiers, the Genelec 8030A monitors offer a
introduces the 8030.LSE PowerPak™, a
dB, and has the ability to deliver an SPL of
wide frequency response of 58 Hz to 20 kHz
new comprehensive multi-channel monitoring
108 dB at 1 meter. In addition, the 7060A
(+/-2.0 dB) from a 5” woofer and 3/4” hard-domed
system specifically designed for post-production
boasts Genelec’s new 6.1 bass management
tweeter. In addition to low harmonic distortion,
suites and recording studios with control rooms
system, which has six signal input and output
the 8030A also offers rear panel bass and
measuring less than 85 m3 (3000 cubic feet) (W
channels (L/C/R Front and L/C/R Rear), as
treble tilt room response controls. The MDE™
x D x H). The 8030.LSE PowerPak™ system is
well as a discrete LFE signal input with a
enclosure of the Genelec 8030A active moni-
a perfectly tailored solution and simplifies the
selectable 85/120 Hz low-pass filter and a
tors is made of die cast aluminum, featuring
process of creating a new multi-channel moni-
summed signal output, providing flexibility and
rugged construction while also providing effi-
toring system or upgrading an existing stereo
easy connection.
cient heat dissipation capability and shielding
monitoring environment to 5.1 surround.
The built-in bass management unit splits the
against RF interference. Each speaker is also
The 8030.LSE PowerPak™ system consists
six main channel input signals into low and high
magnetically shielded for additional protection
of five Genelec 8030A two-way, bi-amplified
frequency components, accurately dividing the
when used in close proximity to video monitors.
active monitors, one Genelec 7060A LSE™
input signal between the subwoofer and main
The Iso-Pod™ table stand delivered with each
Series Active Subwoofer, and a Genelec
speakers. A dedicated LFE In input connector
8030A has adjustable tilt so that the acoustical
Acousti/Tape™ frequency/wavelength mea-
enables easy set-up and accurate monitoring of
axis can be pointed precisely towards the lis-
suring tape. In addition, a Genelec 8030.LSE
the LFE channel in 5.1 and 6.1 digital surround
tener for best sound reproduction. The isolation
PowerPak setup guide is included for accurate
sound systems.
feature prevents colouration caused by conduc-
speaker placement, wiring and fine-tuning.
The system also includes five Genelec
tion of unwanted vibration to the mixing console
The cornerstone of the system is Genelec’s
8030A two-way, bi-amplified active monitors.
revolutionary 7060A LSE™ Series Active
The 8030A is a compact close-field system
The 8030.LSE PowerPak™ once properly
Subwoofer which employs Genelec’s propri-
featuring Genelec’s proprietary Minimum Dif-
set up will provide an accurate and stable rep-
etary Laminar Spiral Enclosure™ (LSE™)
fraction Enclosure™ (MDE™). The rounded
resentation of any multichannel audio signal,
technology. Designed for multi-channel pro-
corners and continuously curving forms of the
yet its compact size makes it applicable to
fessional surround sound monitoring envi-
enclosure blend seamlessly into the improved
almost any listening environment.
or other mounting surface.
8030.LSE PowerPak™ Data Sheet
SYSTEM SPECIFICATIONS
Free field frequency response
(+/- 3 dB)
7060A BASS MANAGEMENT SYSTEM
7060A
8030A
29 Hz…85 Hz
(Main channels)
58 Hz...20 kHz
Maximum short term sine wave
averaged SPL output
≥ 108 dB SPL
≥ 100 dB SPL
Maximum peak SPL output
≥ 113 dB SPL
≥ 106 dB SPL
Self generated noise level in
free field @ 1 m on axis
(A-weighted)
≤ 15 dB
≤ 10 dB
Harmonic distortion
@ 95 dB SPL
<2%
@ 85 dB SPL
< 2 % (50...150 Hz)
< 0.5 % (> 150 Hz)
Drivers (Magnetically shielded)
205 mm (10”)
7060A
130 mm (5”) woofer
19 mm (3/4”) dome tweeter
Weight
26 kg (57 lbs)
5.6 kg (12.3 lbs)
Dimensions
Height
Width
Depth
527 mm (20 3/4”)
462 mm (18 316”)
360 mm (14 3/16”)
299 mm (11 13/16”)*
189 mm (7 7/16”)
178 mm (7”)
*Including Iso-Pod™ table stand
AMPLIFIER SECTION
7060A
8030A
Short term amplifier output
power (Long term output power
is limited by driver unit
protection circuitry)
Bass
Treble
120 W
N/A
40 W
40 W
Amplifier system distortion
at nominal output
THD
≤ 0.05 %
≤ 0.05 %
220, 230, 240, 100/200
or 115/230 V according
to region
100, 120, 220 or 230 V
according to region
15 VA
150 VA
10 VA
80 VA
Mains voltage
Power consumption (average)
Idle
Full output
Subsonic filter
(18 dB/octave) below
29 Hz
Upper bandwidth/LFE cutoff
85 Hz/120 Hz selectable
Connectors
Input
Output
7 XLR female (6 Main + 1 LFE)
7 XLR male (6 Main + 1 Sum Out)
XLR pin sequence
pin 1 gnd
pin 2 +
pin 3 -
Input impedance
10 kOhm balanced
Input level for 100 dB SPL
output @ 1 m
Variable from +6 to –12 dBu
Crossover frequency,
(sub/main channels)
85 Hz
Crossover slopes
Lowpass
Highpass
36 dB/octave
12 dB/octave
Midband rejection >400 Hz
≥ 50 dB
Bass roll-off control operating
range in 2 dB steps
From 0 to –6 dB @ 30 Hz
Phase matching control
in 90° steps
From 0 to 270° @ 85 Hz
Bypass
Bypasses the bass management for the main channels
LFE sensitivity
Adjustable 0 / +10 dB
Redirect
Redirects LFE channel signal above 85 Hz to center channel
Sum In
Changes subwoofer to Sum In mode, main inputs defeated
Test tone for phase adjustment
85 Hz
Remote LED connector (RJ11)
Input for optional Power/Overload+Bypass remote controls
8030.LSE POWERPAK ACOUSTIC SPECIFICATIONS
8030.LSE PowerPak
Recommended listening
distance
1.7 to 2.5 m (5 to 8 ft)
Typical max short term
RMS SPL all channels driven
108 dB, Flat response weighting
Suggested acoustic space max.
85 m3 (3000 cubic feet)
www.genelec.com
Genelec Document BBAGE030. Copyright Genelec Oy 1.2005. All data subject to change without prior notice
International enquiries:
In the U.S. please contact
In China please contact:
Genelec, Olvitie 5
Genelec, Inc., 7 Tech Circle
Genelec China Representative Office
FIN-74100, Iisalmi, Finland
Natick, MA 01760
Soho New Town, 88 Jianguo Road
Phone +358 17 83881
Phone 508 652 0900
D-1504, Chaoyang District
Fax +358 17 812 267
Fax 508 652 0909
Beijing 100022, China
Email [email protected]
Email [email protected]
Phone +86 10 8580 2180 Fax +86 10 8580 2181
Email [email protected]