InterpretingHumidityInstrument Specifications Helping you make a better measurement. WebinarPresenters&HumidityExperts BruceMcDuffee MichaelBoetzkes DavidLove Agenda&LearningObjectives • ExaminethemetrologicalmeaningofAccuracy • SeehowspecificationsusethetermAccuracy • Lookingbeyond“Accuracy” • Initialperformance • LongTermDrift(performanceafteraperiodoftime) • Measurementsawayfromthecalibrationtemperaturepoints • Howtocompareinstruments WhatisAccuracy? Choosethebestanswer: A. Theclosenessofameasurementtothetruevalue B. Closenessofagreementbetweenameasuredquantityvalueandatrue quantityvalueofameasurand C. the condition or quality of being true, correct, or exact; freedom from error or defect; precision or exactness; correctness D. Anumericalindicationoftheoverallperformanceofaninstrumentduringthe manufacturer’srecommendedcalibrationinterval AccurateDefinitionofAccuracy TheVIM(BIPM- Internationalvocabularyofmetrology– Basicandgeneralconceptsandassociatedterms) “closenessofagreementbetweenameasuredquantity valueandatruequantityvalueofameasurand” Bureau international des poids et mesures AccurateDefinitionofAccuracy “closenessofagreementbetweenameasured quantityvalueandatruequantityvalueofa measurand” • Measurand - quantityintendedtobemeasured • MeasuredQuantityValue- quantityvaluerepresentingameasurementresult • TrueQuantityValue- quantityvalueconsistentwiththedefinitionofaquantity • QuantityValue- numberandreferencetogetherexpressingmagnitudeofa quantity,forexample5°C,543meters Bureau international des poids et mesures WhatdoesNISTsay? TN1297AppendixD(referencetoVIM) • “closenessoftheagreementbetweentheresult ofameasurementandthevalueofthe measurand” NISTComments: • Accuracyisaqualitativeconcept • Oneshouldnotuseaccuracyquantitatively,that is,associatenumberswithit;numbersshould beassociatedwithmeasuresofuncertainty instead. CommonMisconceptions • Accuracyspecificationcoverseverything. • Theothervaluesonthedatasheetareall includedintheaccuracyspecification. • Instrumentsaysaccuracyis+/-1%RHthenIcan expecttheerrortobelessthan1%RHwhenI senditinforcalibrationnextyear. • Theinstrumentcanbeusedatanytemperature andstillhasanaccuracyof1%RH. U = k u12 + u 22 + u32 + u 42 + u52........ Whatdoestheaccuracyspecificationmean? ManufacturinglimitofdifferencebetweentheUnitUnderTestandtheReference • Typicallyincludes • Linearity • Repeatability • Hysteresis • Typicallyignores • Referenceuncertainty • Longtermdrift Comments&Questions Ifwedon’t gettoyourquestion today,we’llrespond viaemail afterthewebinar. LookingBeyondAccuracy • Otherkeyparameters • Calibrationuncertainty • Longtermdrift • Temperaturecompensation • Oftenneedtolookbeyondthe webpagespecifications • • • • Datasheets Product/Usermanuals Askthemanufacturer Calibrationcertificate CalibrationUncertainty • Providescontextto“Accuracy”specification. • Everymeasurementhasuncertainty(evenNIST) • Akeypartofthetraceabilityofameasurement • Itistheindicationofhowtheaccuracyof measurementshavedegradedthroughthe chainofcalibrationsgoingbacktoNISTand essentiallybacktoSI. Drift • Allinstrumentswilldriftbut notallbythesameamount • Notalwaysonthedatasheet CommonCausesofDriftinRelativeHumidity Particulate Vapor • Dust - Slowingdownofresponsetime (increasehysteresis) • Salts - Createasaltsolutiononsensor surfaceincreaseslocalhumidity • Outgassingofproductsinchambersmay effectdielectricinsensors,orcause delamination. • Protection - mechanicalfilters • Protection - highqualitysensorstested forthechemical DriftinRHSensorsCausedbyChemicals • Chemicalresistanceguides • Specifyallowable concentrationsofchemicals • Foundinusermanuals TemperatureCompensation • Specificationsusuallyprovideaccuracyatasingle temperatureorsmallrange(+/-5°C) • Errorincreasesoutsideofthisrange • Examples: • +0.02%RHperKelvindependentontheprocessand electronicstemperature(foradeviationof25°C) • At-20…+40°C±(1.0+0.008xreading) • At-40…+180°C±(1.5+0.015xreadings) Comments&Questions Ifwedon’t gettoyourquestion today,we’llrespond viaemail afterthewebinar. SampleSpecificationsfor65%RHat23°C Specification InstrumentA Accuracy Accuracy Includes: - Non-linearity - Hysteresis - Repeatability InstrumentB AnnualDrift InstrumentD ±0.8%RH ±1.3%RH+0.003*mv ±1%RH (± 1.495%RH) Measurement Uncertainty Includes: - Non-linearity - Hysteresis - Repeatability - CalibrationUncertainty CalibrationUncertainty InstrumentC ±1%RH+0.007*mv (± 1.46%RH) ±1%RH ±0.5%RH <1%RH NormalizingSpecifications InstrumentA InstrumentC Standard Uncertainty Comment Parameter U Distribution Divisor Accuracy(Linearity, Repeatability,Hysteresis) 1 Rectangular 1.732 0.577 FromDataSheet CalibrationUncertainty 1 Normal 2 0.500 FromDataSheet AnnualDrift 1 FromHistorical DataSheet Rectangular 1.732 0.577 CombinedUncertainty 0.957 ExpandedUncertaintyk=2 ±2.0%RH Parameter U Measurement Uncertainty (Linearity,Repeatability, Hysteresis,Calibration Uncertainty) 1.46 AnnualDrift 1 Distribution Divisor Standard Uncertainty Comment Normal 2 0.730 FromDataSheet Rectangular 1.732 0.577 BestEstimate CombinedUncertainty 0.9307 ExpandedUncertaintyk=2 ±1.9%RH InstrumentD InstrumentB Parameter Accuracy U 0.8 CalibrationUncertainty AnnualDrift 0.5 1 Distribution Rectangular Divisor 1.732 Standard Uncertainty Comment 0.462 FromDataSheet FromCalibration Certificate Normal 2 0.250 Rectangular 1.732 0.577 FromDataSheet CombinedUncertainty 0.780 ExpandedUncertaintyk=2 ±1.6%RH Parameter U Distribution Divisor Accuracy(Linearity, Repeatability,Hysteresis) 1.5 Rectangular 1.732 CalibrationUncertainty AnnualDrift 0.6 1 Standard Uncertainty Comment 0.863 Normal 2 0.300 Rectangular 1.732 0.577 CombinedUncertainty 1.081 ExpandedUncertaintyk=2 ±2.2%RH FromDataSheet FromAssociated CalibratorData Sheet BestEstimate Takeaways 1. TheAccuracySpecificationdoesnotprovidethewholepictureof instrumentperformance,especiallyforlongtermperformance(1 Year). 2. DataSheetsareonlythebeginningtounderstandinginstrument performance,theydonotalwayscontainalltheinformationrequired tomakeaninformeddecision. 3. Themostimportantvalueofinstrumentperformanceisthe1year performancevalue. Comments&Questions Ifwedon’t gettoyourquestion today,we’llrespond viaemail afterthewebinar. HumidityAcademy • Resourcesformakingabettermeasurement • • • • • Psychrometric charts Technicalnotes Humiditycalculator Applicationnotes more www.rotronic-usa.com/humidity-academy NextWebinar Traceability– WhatisitandHowtoAchieveit? Thursday,January14th 1:00PMEST Registeratwww.rotronic-usa.com/humidity-webinars Takeaways • Howdoestraceabilityaffectthemeasurementsthatwetake? • HowcanIprovetraceabilityofmymeasurements? • HowcanIensurethatmysuppliersareactuallyprovidingtraceablecalibration results? Helpingyoumakeabetterhumidity measurement– andmore. Transmitters,portablemetersand loggersfor: • • • • • • • Humidity CarbonDioxide LowDewPoint WaterActivity DifferentialPressure MonitoringsystemsforcGMP ISO17025calibrations(humidityand temperature) Postwebinarsurvey Thankyou! email:[email protected] USandSouthAmerica:www.rotronic-usa.com Canada:www.rotronic.ca OutsideAmericas:www.rotronic.com Futurewebinarregistrations: www.rotronic-usa.com/humidity-webinars Ondemand www.rotronic-usa.com/humidity-academy/humidity-webinars/webinars-on-demand/
© Copyright 2026 Paperzz