High Technology, Inc Centrifuges 2017 Catalog Centrifuge Selection Guide HTI PowerSpin™ Centrifuge Selection Guide C806 C8724 C822 This guide should help you choose the right HTI centrifuge for your specific needs. CMH30 C881M Urine Sample Centrifugation: A note of caution if you spin Urine specimens: If you have a fixed speed centrifuge, chances are very good it is set the RCF and speed for spinning blood samples only. Urine specimens must be spun at a greatly reduced RCF in order to properly prep the sample. If your facility is subject to CLIA and you spin urine samples in a blood centrifuge, the CLIA inspector may not allow the centrifuge to pass inspection. You will be asked to either stop spinning urine samples, or acquire a centrifuge capable of spinning at the correct RCF for separating urine samples. Speed (RPM) vs. g-Force (RCF): The most important factor when choosing a centrifuge is the g-Force, or RCF, not the speed. The RCF determines the ability of a centrifuge to separate the specimen. Most specimens must be spun within a specific RCF range in order to properly prep the sample for testing and analysis. The guide below will help you select a model based on RCF, RPM, # of tubes, specimens and other attributes. CLIA, Calibration and speed checking: Your lab or practice may be subject to CLIA regulations if what you do is considered to be "moderately complex", or "highly complex". CLIA, (Clinical Laboratory Improvement Amendment of 1988); may dictate that your centrifuges need to be "Calibrated" every 6 months. CLIA inspectors may visit your facility to make sure you are maintaining your equipment and following protocols; and that your equipment is capable of performing the protocols properly, etc. Digital Photo-Tachometer • RPMs instantly display on large LCD screen • Standard adhesive reflective tape included • Highly accurate scientific tool, includes case Calibration involves using a tachometer to check the speed of your centrifuge for accuracy. CLIA inspectors will "pass" a centrifuge that operates within plus or minus 100 RPM of the actual setting. If for example, your centrifuge is set to spin at 3,400 RPM; CLIA will pass it if it is anywhere between 3,300 and 3,500 RPM; as long as your protocol calls for spinning in that range as well. To check your centrifuge you can purchase a tachometer, item # C800-75. Model SKU Number of Tubes Tube Capacity Blood Item No. C800-75 Specimens Fecal Urine Description Photo-Tachometer DNA Microhematocrit Protein Speed Rotor Maximum RPM Maximum RCF (g) FX C806 6 2-15 ml Yes No No With Adapters No Fixed Fixed 3400 1320 FX C808 8 2-15 ml Yes No No With Adapters No Fixed Fixed 3400 1320 LX C856 6 2-15 ml Yes Yes Yes With Adapters No Variable Fixed 300-4,000 Up to 1,828 LX C858 8 2-15 ml Yes Yes Yes With Adapters No Variable Fixed 300-4,000 Up to 1,828 PX C826 6 2-15 ml Yes No No With Adapters No Fixed Fixed 3,500 1,640 PX C828 8 2-15 ml Yes No No With Adapters No Fixed Fixed 3,500 1,640 HX C822 6 2-15 ml Yes No No With Adapters No Fixed Horizontal 3,400 1,680 DX C8724 24 2-15 ml Yes Yes Yes With Adapters No Variable Fixed 500-4,000 2,508 DX C8706 6 2-15 ml Yes Yes Yes With Adapters No Variable Horizontal 500-4,000 2,508 DX C8760 4 60 ml 60 mL No No No No Variable Fixed 500-4,000 2,508 2,508 14,075 DX C8704 4 2-50 ml Yes Yes Yes With Adapters No Variable Horizontal 500-4,000 CMH CMH30 24 Capillary MH No No Yes No Fixed Horizontal 12,000 BX C881 6 2-12 ml Yes Yes Yes With Adapters No Variable Fixed 5,000 2,570 BX C882 24 Capillary MH No No Yes No Variable Horizontal 11,000 13,250 BX C883 24 0.5-3 ml Yes No No No Yes Variable Fixed 13,000 15,495 How to calculate RCF: RCF = Relative Centrifugal Force (also known as “G-Force”) Centrifuge RCF Calculation: RCF = 1.12 x R(mm) x Krpm x Krpm where R: Centrifuge rotor radius (mm) and Krpm: Centrifuge speed in thousands High Technology, Inc. www.htidiagnostics.com Example: If rotor radius is 102mm, speed is 3.4Krpm (3400rpm), then RCF = 1.12 x 102 x 3.4 x 3.4 = 1320g (508) 660-2221 Walpole, MA USA PowerSpin™ Centrifuges, FX / LX PowerSpin™ Centrifuges, Models FX and LX HTI® PowerSpin™ Series centrifuges are compact, economical and quiet. We offer both fixed (FX) and variable (LX) speed models with fixed angle rotors, for 6 or 8 tubes to spin 7.5 – 15 ml tubes. By using adapters, you can also spin tubes ranging from 2 – 7 ml. An optional Tube Holdster™ allows you to have up to 18 tubes or adapters at your fingertips, side-mounted on the centrifuge. PowerSpins are pre-drilled/tapped to accept optional Tube Holdsters. LX Color Coded Quick Speed setting reference: Brown Fecal Yellow Urine Red Blood Shown with optional Tube Holdster™ C856 Model LX Centrifuge Actual Size: 10.2” x 11.8“ x 8” Shipping Dimension: 13.4” x 14.8” x 10.6“ Net Weight: 15 lbs Shipping Weight: 18 lbs Tube Adapters C800-04 C800-05 C800-03 Tube Shield Specifications: • Standard 6 or 8 place rotor for 2 to 15 ml tubes • Adapters for 2 ml or 4-7 ml tubes (part # C800-04 & C800-03) • 0-30 minute timer with bell tone signal • Quiet at full speed, only 58 decibels • Latching lid with safety switch triggered to shut-off power to the motor when the lid is opened • Stainless Steel rotor chamber is easily accessible for cleaning and disinfection • Maintenance-free brushless motors • Suction cup rubber feet for stability while reducing vibration • Lid window for strobe tachometer RPM check • One Year Limited Warranty Item No. C806 C806H C808 C808H C856 C856E C856H C856H-E C858 C858E C858H C858H-E C800-01 C800-02 C800-03 C800-04 C800-05 C800-18 Description FX, 6 Place Fixed Speed Centrifuge, 3400 rpm FX, C806 with Tube Holdster FX, 8 Place Fixed Speed Centrifuge, 3400 rpm FX, C808 with Tube Holdster LX, 6 Place Variable Speed Centrifuge, 300 - 4000 rpm LX, 6 Place, same as above, 220V LX, C856 with Tube Holdster LX, C856E with Tube Holdster, 220V LX, 8 Place Variable Speed Centrifuge, 300 - 4000 rpm LX, 8 Place, same as above, 220V LX, C858 with Tube Holdster LX, C858E with Tube Holdster, 220V 8 Place Rotor for PowerSpin Centrifuges Tube Shield, Pkg. of 2 Short Tube Adapters, for 4-7 ml tubes, Pk/10 Small Tube adapters, for 2 ml tubes, Pk/2 Greiner Tube Lift Adapters, Pk/12 Tube Holdster, 18 Place C806 Model FX Centrifuge PowerSpin™ Model Rotor radius Fecal Speed Fecal Time Urine Speed Urine Time Blood Speed Blood Time FX C806 / C808 102 mm RPM RCF N/A N/A 3400 1320 10-15 minutes LX C856 / C858 102 mm RPM RCF 1400 224 10 minutes 2000 456 5 minutes 3100/4000 1097/1828 10 minutes RPM = Revolutions Per Minute RCF = Relative Centrifugal Force (also known as “G-Force”) High Technology, Inc. www.htidiagnostics.com (508) 660-2221 Walpole, MA USA HX C822 130 mm RPM RCF PX C826 / C828 102 mm RPM RCF N/A N/A N/A N/A 3400 1680 10 minutes 3500 1640 10 minutes PowerSpin™ Centrifuges PowerSpin™ PortaSpin™ Centrifuge, PX Mobile The PortaSpin PX allows you to take your practice on the road. Whether you are a mobile vet, visiting nurse or doctor, we have a PortaSpin that will meet your needs. Available with 6 or 8 place rotors and adapters to fit tubes ranging from 2 – 15 ml. Standard with 12 Volt car lighter adapter, a 110V electrical outlet adapter is optional for use back at the lab. When using this unit you will most likely not be in your lab setting so you will not have you standard bench-top tube rack. We strongly recommend purchasing the optional Tube Holdster, attaches easily to the side of the centrifuge and will hold up to 18 tubes or adapters. Item No. C826 C826H Description PX, PortaSpin 6 Place Mobile Centrifuge PX, PortaSpin 6 Place Mobile Centrifuge with Tube Holdster PX, PortaSpin 8 Place Mobile Centrifuge PX, PortaSpin 8 Place Mobile Centrifuge with Tube Holdster PX, PortaSpin 12V DC Car Adapter PX, PortaSpin 110V AC Adapter PX, PortaSpin 220V AC Adapter Short Tube Adapters, for 4-7 ml tubes, Pk/10 Small Tube adapters, for 2 ml tubes, Pk/2 Greiner Tube Lift Adapters, Pk/12 Fuse for PowerSpin Centrifuges Tube Holdster, 18 Place C828 C828H C826-06 C826-12 C826-12E C800-03 C800-04 C800-05 C800-10 C800-18 C826H Model PX PortaSpin™ Actual Size: 10.2” x 11.8“ x 8” Shipping Dimension: 13.4” x 14.8” x 10.6“ Net Weight: 15 lbs Shipping Weight: 18 lbs PortaSpin features a level built into the lid to make sure you are level before and during your run. A sturdy stainless steel handle makes carrying the centrifuge easy. Specifications: • • • • • • • • PowerSpin™ Centrifuge, HX Horizontal Spin Designed for the professionals on the go Plugs into a car 12V power outlet 3500 RPM fixed speed for blood 30 minute timer Convenient stainless steel carrying handle Lid mounted "fish-eye" level to level before spinning Optional AC power adapter available One Year Limited Warranty The horizontal spin fixed speed PowerSpin™ HX centrifuge spins at 3400 RPM. The horizontal rotor insures a clean, complete separation of cellular components. Using a horizontal rotor for spinning Serum Separator Tubes (SSTs) creates a tight uniform horizontal seal, reducing the risk of red cell leakage. The C822 features a Zero RPM safety lock, so the lid can not be opened while the rotor is in motion. A digital timer and LCD display provide user with the precise control of the spin cycle. Powerful brushless motor is maintenance free for years of dependable use. Stainless steel guard bowl is easy to clean and maintain. Actual Size: 14.4” x 11.6“ x 8.9” Shipping Dim.: 16.5” x 13” x 10“ Net Weight: 22 lbs Shipping Weight: 25 lbs Specifications: • • • • • • • • Horizontal Six place rotor for 2 to 10 ml tubes Quiet at full speed, only 58 decibels Stainless Steel chamber for easy cleaning and disinfection HX models run at fixed speed 3400 RPM 0-99 minute digital timer Suction cup rubber feet add stability while reducing vibration Lid window for strobe tachometer RPM check One Year Limited Warranty Item No. C822 C822-01 C822-02 C800-03 C800-04 C800-34 Description HX, 6 Place Horizontal Spin Centrifuge 6 Place Swing Out Rotor Tube Shield, Pkg. of 2 Short Tube Adapters, for 4-7 ml tubes, Pk/10 Small Tube adapters, for 2 ml tubes, Pk/2 Microhematocrit Adapters, 4 tubes each, Pk/2 C822 Model HX Horizontal Centrifuge C800-34 Microhematocrit Adapters High Technology, Inc. www.htidiagnostics.com (508) 660-2221 Walpole, MA USA PowerSpin™ Centrifuges, DX HTI® is proud to present the PowerSpin™ DX Centrifuge With 4 rotor options this centrifuge is a great answer for every day laboratory tasks. - 24 place fixed rotor for 2-15ml tubes ( #C8724 ) - 6 place horizontal rotor for 2-15ml tubes ( #C8706 ) - 4 place horizontal rotor for up to 50ml tubes ( #C8704 ) - 4 place fixed rotor for 60ml syringes ( #C8760 ) The PowerSpin™ DX has variable speed 500 – 4000 RPM, to ensure a clean and complete separation. Quiet and dependable, with a maintenance free motor, it can be used to process blood, urine, semen and other specimens. Model #C8724 The all digital front panel makes it easy to select speed and run time. Oversized LCD display shows status, time, speed (RPM) and RCF (g). Precise speed control enables you to comply with CLIA recommendations for specific specimens. • Zero RPM Safety Latching System prevents lid from being opened while rotor is spinning • Quiet running, only 50 decibels at 3400 RPM • 99 minute digital timer , 1 sec increment • 500-4000 RPM, 100 RPM increment • Remembers last setting for quick repeat runs • Adjustable Acceleration and Deceleration • Stainless steel rotor chamber for easy cleaning • Suction cup rubber feet eliminate vibration •Available in 110V and 220V - Contact HTI for details Professional Digital Non-Contact Photo-Tachometer • • • • • • Highly accurate, scientific tool Easy to operate Standard adhesive reflective tape (included) Aim and measure--RPMs instantly display on large LCD screen. Includes custom protective cushioned storage case Order pn# C800-75 High Technology, Inc. www.htidiagnostics.com (508) 660-2221 Walpole, MA USA Model C8724 • 24 place fixed angle rotor ( pn#C8600-03 — rotor only) • Designed to accept 10ml blood tubes and up to 15ml urine tubes • 2ml tubes with small tube adaptor (pn# C800-04 — set of 2) • 5ml tubes with short tube adaptor (pn# C800-03 — set of 10) Model C8706 • 6 place horizontal rotor ( pn#C8600-01 — rotor only) • Specifically designed to keep tubes vertical at rest • Designed to accept 10ml blood tubes and up to 15ml urine tubes • 2ml tubes with small tube adaptor (pn# C800-04 — set of 2) • 5ml tubes with short tube adaptor (pn# C800-03 — set of 10) Model C8760 • • 4 place fixed angle rotor ( pn#C8600-05 — rotor only) Designed to accept 60ml Syringes Model C8704 UNICO Model Item • 4 place horizontal rotor ( pn#C8600-02 — rotor only) • Designed to accept 50ml tubes • With adaptors can accept most of the tubes used in laboratory • 6 to 15ml tubes with adaptor (pn# C8604-02 — set of 2) • 3 to 5ml tubes with adaptor (pn# C8604-03 — set of 2) • 0.5 to 2ml tubes with adaptor (pn# C8604-04 — set of 2) Speed Max. RCF Rotor Tube Size Tube Holdster 24 place PowerSpin™ DX C8724 500 – 4000 RPM 2508 24 place fixed 2-15ml Optional PowerSpin™ DX C8724H 500 – 4000 RPM 2508 24 place fixed 2-15ml Included PowerSpin™ DX C8706 500 – 4000 RPM 2508 6 place horizontal 2-15ml Optional PowerSpin™ DX C8706H 500 – 4000 RPM 2508 6 place horizontal 2-15ml Included PowerSpin™ DX C8704 500 – 4000 RPM 2508 4 place horizontal 50 ml Optional PowerSpin™ DX C8704H 500 – 4000 RPM 2508 4 place horizontal 50 ml Included PowerSpin™ DX C8760 500 – 4000 RPM 2508 4 place fixed 60 ml N/A High Technology, Inc. www.htidiagnostics.com (508) 660-2221 Walpole, MA USA PowerSpin™ Centrifuges, BX PowerSpin™ Centrifuge, BX The BX is a versatile, state of the art variable-speed centrifuge series with three rotor options. Options are: • Blood/Urine Tube, 2-12 ml Rotor: Max Speed = 5,000 RPM • Microhematocrit/Capillary Tube Rotor: Max Speed = 11,000 RPM • Microcentrifuge Tube, 0.5-3 ml Rotor: Max Speed = 13,000 RPM Your BX can be a dedicated centrifuge with any one of the rotors, or a versatile addition to your lab with up to three interchangeable rotors with speeds from 1,000 – 13,000 RPM. BX Centrifuges have advanced safety features such as a Zero RPM lid latch control system (which makes sure the lid can not be opened if the rotor is spinning), a stainless steel rotor chamber, Auto-unbalance detection and shut-down (will shut-down the motor if an off-balance condition is detected). With three interchangeable rotors, the centrifuge features ARD (Automatic Rotor Detection), the unit can automatically tell which of the three rotors are loaded. This is an important safety feature as each of the three rotors has a different maximum speed. The Microhematocrit rotor features a Tube Reader built-into the rotor lid. This makers reading crit values quick and easy after your run, without having to remove the tubes and place them in a reader, or on a reader-card, etc. The standard Blood & Urine tube rotor fits 7.5 – 12 ml tubes and will not accept 15 ml tubes. With adapters shown below, you can spin 0.5 – 3 ml tubes (C800-04), or 3.5 – 6.5 ml tubes (C800-03). C881 Item No. C881M C881ME C882 C882E C883 C883E C884 C884E C885 C885E C886 C886E C887 C887E C881-03 C881-04 C800-34 C8600-34 C800-512 C800-550 C800-500 Specifications: • • • • • • • • • Description BX, 6 Place Fixed Angle Metal Rotor Centrifuge BX, 6 Place, Fixed Angle Metal Rotor Centrifuge, 220V BX, 24 Place Hematocrit Centrifuge BX, 24 Place Hematocrit, same as above, 220V BX, 24 Place Micro-Tube Centrifuge BX, 24 Place Micro-Tube, same as above, 220V BX, 6 Place Tube rotor & 24 Place Microhematocrit BX, 6 Place Tube rotor & 24 Place Microhematocrit, 220V BX, All three available rotors, 110V BX, All three available rotors, 220V BX, 24 Place Microhematocrit & 24 Place Microcentrifuge BX, 24 Place Microhematocrit & 24 Place Microcentrifuge, 220V BX, 6 Place Tube rotor & 24 Place Microcentrifuge BX, 6 Place Tube rotor & 24 Place Microcentrifuge, 220V Short Tube Adapters, for 4-7 ml tubes, Pk/10 Small Tube adapters, for 2 ml tubes, Pk/2 Adapters for four Microhematocrit tubes, Pk/2 Adapters for four Microhematocrit tubes, Pk/2 12 ml Conical Urine Tube, 16 x 100 mm, Pk/12 12 ml Conical Urine Tube, 16 x 100 mm, Pk/50 12 ml Conical Urine Tube, 16 x 100 mm, Pk/500 PowerSpin™ Model Rotor radius Fecal Speed Fecal Time Urine Speed Urine Time Blood Speed Blood Time BX C881 92 mm RPM RCF 1600 263 10 minutes 2000 411 5 minutes 5000 2570 4 minutes Variable speed up to 13000 RPM (up to 5000 RPM on C881) Zero RPM Safety Lock and Rotor Unbalance Sensor Automatic Rotor recognition Digital Timer 0-99 minutes Maintenance free brushless motor Exterior is chemical resistant and easy to clean and disinfect Lid window for strobe tachometer RPM check Standard 115V/60Hz; (220V/50Hz option available) One Year Limited Warranty Digital LCD display and push button control panel are designed to give the user complete control throughout the spin cycle. • The “Open” button is disengaged while the rotor is in motion • LCD mode button will adjust displayed data according to your preferences BX C882 86 mm RPM RCF N/A N/A 13,000 16,250 5 minutes RPM = Revolutions Per Minute RCF = Relative Centrifugal Force (also known as “G-Force”) High Technology, Inc. www.htidiagnostics.com (508) 660-2221 Walpole, MA USA BX C883 82 mm RPM RCF N/A 2300 485 5 minutes 13,000 15,495 5 minutes PowerSpin™ Centrifuges, BX PowerSpin™ Centrifuge, BX BX Versatility: New Microhematocrit Tube Adapters: We have developed several microhematocrit tube adapters that can be used with the Blood & Urine Tube Rotor, making a single rotor much more versatile and eliminating the need to purchase an additional rotor, or change rotors. Both New C80034 and C8600-34 Adapters come in a Pkg/2 adapters, each and each adapter holds up to 4 MH tubes. The Blood & Urine rotor runs at a max of 5,000 RPM, much slower than traditional microhematocrit rotors with a 5 min. run. With our adapters, at 5,000 RPM, you can achieve a complete microhematocrit separation in an 8 min. run. 24 place rotor for 0.5 to 3ml Micro tubes The BX’s large digital display continuously shows three parameters in real-time: Speed (RPM), g-Force (RCF) and Time – how much time is left in the run. A unique feature allows the user to select which of these three parameters to display in an extra large font, for quick and easy viewing. BX’s feature maintenance-free brushless motors and a lid window for tachometer calibration checks. An intuitive button panel is quick and easy to use. BX Rotors and Acrylic Rotor Rack 24 place rotor for capillary Microhematocrit tubes. Hematocrit Reader incorporated into the cover Select from three rotor options for your BX centrifuge. For your convenience, we designed the C880-10 BX Rotor Rack to store all three rotors, the rotor changing tool and all your accessories. This rack can sit bench-top next to the BX, or can be wall-mounted, whichever works best for your lab. Also includes 18-place Tube Holdster™ for any size tube from 2-15ml. Item No. C880-01M C880-02 C880-03 C880-10 Description Metal, 6-Place Blood/Urine Tube Rotor 24-Place Microhematocrit Rotor 24-Place Microcentrifuge Rotor BX Rotor Rack with Tube Holdster™ 6 place Blood/Urine Tube Rotor (accepts maximum 12 ml urine tubes) The BX Acrylic Rotor Rack organizes your rotors, rotor changing tool, and accessories all in one compact unit. CMH30 Microhematocrit Centrifuge Model CMH30 is made of formed metal and has a baked paint application that is acid and reagent resistant. A safety switch built into the handle assembly disconnects the power to the motor whenever the latch is lifted. The brushed motor is mounted on rubber mounts to provide quiet running and dampen vibration. Microhematocrit Tube Reader included with CMH30 Specifications: • Twenty-four (24) place rotor with replaceable rubber ring and screw down metal lid • Includes Microhematocrit Tube Reader • Nominal speed is 12,000 RPM • Dependable mechanical 5-minute timer with bell signal at end of run • All metal housing for years of dependable use • Safety switch in latch shuts off motor when lid is lifted • Electric motor braking • Indicator light tells when unit is in use • Standard 115V/60Hz AC • One Year Limited Warranty Item No. Description CMH30 Microhematocrit Centrifuge, 24 Place, 110V CMH30E Microhematocrit Centrifuge, 24 Place, 220V CMH30-Reader Microhematocrit Tube Reader Actual Size: 11.6” x 10.3“ x 9.3” Shipping Dim.: 12.7” x 12.7” x 12.2“ Net Weight: 17.4 lbs Shipping Weight: 19.4 lbs High Technology, Inc. www.htidiagnostics.com CMH30 Centrifuge (508) 660-2221 Walpole, MA USA
© Copyright 2026 Paperzz