Centrifuges - HTI Diagnostics

High Technology, Inc
Centrifuges
2017 Catalog
Centrifuge Selection Guide
HTI PowerSpin™ Centrifuge Selection Guide
C806
C8724
C822
This guide should help you choose the right HTI
centrifuge for your specific needs.
CMH30
C881M
Urine Sample Centrifugation:
A note of caution if you spin Urine specimens: If you have a fixed
speed centrifuge, chances are very good it is set the RCF and
speed for spinning blood samples only. Urine specimens must be
spun at a greatly reduced RCF in order to properly prep the
sample. If your facility is subject to CLIA and you spin urine
samples in a blood centrifuge, the CLIA inspector may not allow
the centrifuge to pass inspection. You will be asked to either stop
spinning urine samples, or acquire a centrifuge capable of
spinning at the correct RCF for separating urine samples.
Speed (RPM) vs. g-Force (RCF):
The most important factor when choosing a centrifuge is the
g-Force, or RCF, not the speed. The RCF determines the ability of
a centrifuge to separate the specimen. Most specimens must be
spun within a specific RCF range in order to properly prep the
sample for testing and analysis. The guide below will help you
select a model based on RCF, RPM, # of tubes, specimens and
other attributes.
CLIA, Calibration and speed checking:
Your lab or practice may be subject to CLIA regulations if what
you do is considered to be "moderately complex", or "highly
complex". CLIA, (Clinical Laboratory Improvement Amendment
of 1988); may dictate that your centrifuges need to be
"Calibrated" every 6 months. CLIA inspectors may visit your
facility to make sure you are maintaining your equipment and
following protocols; and that your equipment is capable of
performing the protocols properly, etc.
Digital Photo-Tachometer
• RPMs instantly display on large
LCD screen
• Standard adhesive reflective
tape included
• Highly accurate scientific tool,
includes case
Calibration involves using a tachometer to check the speed of
your centrifuge for accuracy. CLIA inspectors will "pass" a
centrifuge that operates within plus or minus 100 RPM of the
actual setting. If for example, your centrifuge is set to spin at
3,400 RPM; CLIA will pass it if it is anywhere between 3,300
and 3,500 RPM; as long as your protocol calls for spinning in
that range as well. To check your centrifuge you can purchase
a tachometer, item # C800-75.
Model
SKU
Number
of Tubes
Tube
Capacity
Blood
Item No.
C800-75
Specimens
Fecal
Urine
Description
Photo-Tachometer
DNA
Microhematocrit Protein
Speed
Rotor
Maximum
RPM
Maximum
RCF (g)
FX
C806
6
2-15 ml
Yes
No
No
With Adapters
No
Fixed
Fixed
3400
1320
FX
C808
8
2-15 ml
Yes
No
No
With Adapters
No
Fixed
Fixed
3400
1320
LX
C856
6
2-15 ml
Yes
Yes
Yes
With Adapters
No
Variable
Fixed
300-4,000
Up to 1,828
LX
C858
8
2-15 ml
Yes
Yes
Yes
With Adapters
No
Variable
Fixed
300-4,000
Up to 1,828
PX
C826
6
2-15 ml
Yes
No
No
With Adapters
No
Fixed
Fixed
3,500
1,640
PX
C828
8
2-15 ml
Yes
No
No
With Adapters
No
Fixed
Fixed
3,500
1,640
HX
C822
6
2-15 ml
Yes
No
No
With Adapters
No
Fixed
Horizontal
3,400
1,680
DX
C8724
24
2-15 ml
Yes
Yes
Yes
With Adapters
No
Variable
Fixed
500-4,000
2,508
DX
C8706
6
2-15 ml
Yes
Yes
Yes
With Adapters
No
Variable
Horizontal
500-4,000
2,508
DX
C8760
4
60 ml
60 mL
No
No
No
No
Variable
Fixed
500-4,000
2,508
2,508
14,075
DX
C8704
4
2-50 ml
Yes
Yes
Yes
With Adapters
No
Variable
Horizontal
500-4,000
CMH
CMH30
24
Capillary
MH
No
No
Yes
No
Fixed
Horizontal
12,000
BX
C881
6
2-12 ml
Yes
Yes
Yes
With Adapters
No
Variable
Fixed
5,000
2,570
BX
C882
24
Capillary
MH
No
No
Yes
No
Variable
Horizontal
11,000
13,250
BX
C883
24
0.5-3 ml
Yes
No
No
No
Yes
Variable
Fixed
13,000
15,495
How to calculate RCF:
RCF = Relative Centrifugal Force (also known as
“G-Force”)
Centrifuge RCF Calculation: RCF = 1.12 x R(mm) x
Krpm x Krpm
where R: Centrifuge rotor radius (mm)
and Krpm: Centrifuge speed in thousands
High Technology, Inc.
www.htidiagnostics.com
Example: If rotor radius is 102mm, speed is 3.4Krpm
(3400rpm),
then RCF = 1.12 x 102 x 3.4 x 3.4 = 1320g
(508) 660-2221
Walpole, MA USA
PowerSpin™ Centrifuges, FX / LX
PowerSpin™ Centrifuges,
Models FX and LX
HTI® PowerSpin™ Series centrifuges are compact, economical
and quiet. We offer both fixed (FX) and variable (LX) speed
models with fixed angle rotors, for 6 or 8 tubes to spin 7.5
– 15 ml tubes. By using adapters, you can also spin tubes
ranging from 2 – 7 ml. An optional Tube Holdster™ allows you to
have up to 18 tubes or adapters at your fingertips, side-mounted
on the centrifuge. PowerSpins are pre-drilled/tapped to accept
optional Tube Holdsters.
LX Color Coded Quick
Speed setting reference:
Brown Fecal
Yellow Urine
Red
Blood
Shown with optional
Tube Holdster™
C856 Model LX Centrifuge
Actual Size: 10.2” x 11.8“ x 8”
Shipping Dimension: 13.4” x 14.8” x 10.6“
Net Weight: 15 lbs
Shipping Weight: 18 lbs
Tube Adapters
C800-04 C800-05
C800-03
Tube Shield
Specifications:
• Standard 6 or 8 place rotor for 2 to 15 ml tubes
• Adapters for 2 ml or 4-7 ml tubes (part # C800-04 & C800-03)
• 0-30 minute timer with bell tone signal
• Quiet at full speed, only 58 decibels
• Latching lid with safety switch triggered to shut-off power to the
motor when the lid is opened
• Stainless Steel rotor chamber is easily accessible for cleaning
and disinfection
• Maintenance-free brushless motors
• Suction cup rubber feet for stability while reducing vibration
• Lid window for strobe tachometer RPM check
• One Year Limited Warranty
Item No.
C806
C806H
C808
C808H
C856
C856E
C856H
C856H-E
C858
C858E
C858H
C858H-E
C800-01
C800-02
C800-03
C800-04
C800-05
C800-18
Description
FX, 6 Place Fixed Speed Centrifuge, 3400 rpm
FX, C806 with Tube Holdster
FX, 8 Place Fixed Speed Centrifuge, 3400 rpm
FX, C808 with Tube Holdster
LX, 6 Place Variable Speed Centrifuge, 300 - 4000 rpm
LX, 6 Place, same as above, 220V
LX, C856 with Tube Holdster
LX, C856E with Tube Holdster, 220V
LX, 8 Place Variable Speed Centrifuge, 300 - 4000 rpm
LX, 8 Place, same as above, 220V
LX, C858 with Tube Holdster
LX, C858E with Tube Holdster, 220V
8 Place Rotor for PowerSpin Centrifuges
Tube Shield, Pkg. of 2
Short Tube Adapters, for 4-7 ml tubes, Pk/10
Small Tube adapters, for 2 ml tubes, Pk/2
Greiner Tube Lift Adapters, Pk/12
Tube Holdster, 18 Place
C806 Model FX Centrifuge
PowerSpin™
Model
Rotor radius
Fecal Speed
Fecal Time
Urine Speed
Urine Time
Blood Speed
Blood Time
FX
C806 / C808
102 mm
RPM
RCF
N/A
N/A
3400
1320
10-15 minutes
LX
C856 / C858
102 mm
RPM
RCF
1400
224
10 minutes
2000
456
5 minutes
3100/4000 1097/1828
10 minutes
RPM = Revolutions Per Minute
RCF = Relative Centrifugal Force (also known as “G-Force”)
High Technology, Inc.
www.htidiagnostics.com
(508) 660-2221
Walpole, MA USA
HX
C822
130 mm
RPM
RCF
PX
C826 / C828
102 mm
RPM
RCF
N/A
N/A
N/A
N/A
3400
1680
10 minutes
3500 1640
10 minutes
PowerSpin™ Centrifuges
PowerSpin™ PortaSpin™
Centrifuge, PX Mobile
The PortaSpin PX allows you to take your practice on the road.
Whether you are a mobile vet, visiting nurse or doctor, we have
a PortaSpin that will meet your needs. Available with 6 or 8
place rotors and adapters to fit tubes ranging from 2 – 15 ml.
Standard with 12 Volt car lighter adapter, a 110V electrical outlet
adapter is optional for use back at the lab.
When using this unit you will most likely not be in your lab setting
so you will not have you standard bench-top tube rack. We
strongly recommend purchasing the optional Tube Holdster,
attaches easily to the side of the centrifuge and will hold up to 18
tubes or adapters.
Item No.
C826
C826H
Description
PX, PortaSpin 6 Place Mobile Centrifuge
PX, PortaSpin 6 Place Mobile Centrifuge
with Tube Holdster
PX, PortaSpin 8 Place Mobile Centrifuge
PX, PortaSpin 8 Place Mobile Centrifuge
with Tube Holdster
PX, PortaSpin 12V DC Car Adapter
PX, PortaSpin 110V AC Adapter
PX, PortaSpin 220V AC Adapter
Short Tube Adapters, for 4-7 ml tubes, Pk/10
Small Tube adapters, for 2 ml tubes, Pk/2
Greiner Tube Lift Adapters, Pk/12
Fuse for PowerSpin Centrifuges
Tube Holdster, 18 Place
C828
C828H
C826-06
C826-12
C826-12E
C800-03
C800-04
C800-05
C800-10
C800-18
C826H Model PX PortaSpin™
Actual Size: 10.2” x 11.8“ x 8”
Shipping Dimension: 13.4” x 14.8” x 10.6“
Net Weight: 15 lbs
Shipping Weight: 18 lbs
PortaSpin features a level built into the lid to
make sure you are level before and during
your run. A sturdy stainless steel handle
makes carrying the centrifuge easy.
Specifications:
•
•
•
•
•
•
•
•
PowerSpin™ Centrifuge,
HX Horizontal Spin
Designed for the professionals on the go
Plugs into a car 12V power outlet
3500 RPM fixed speed for blood
30 minute timer
Convenient stainless steel carrying handle
Lid mounted "fish-eye" level to level before spinning
Optional AC power adapter available
One Year Limited Warranty
The horizontal spin fixed speed PowerSpin™ HX centrifuge spins
at 3400 RPM. The horizontal rotor insures a clean, complete
separation of cellular components. Using a horizontal rotor for
spinning Serum Separator Tubes (SSTs) creates a tight uniform
horizontal seal, reducing the risk of red cell leakage.
The C822 features a Zero RPM safety lock, so the lid can not
be opened while the rotor is in motion. A digital timer and LCD
display provide user with the precise control of the spin cycle.
Powerful brushless motor is maintenance free for years of
dependable use. Stainless steel guard bowl is easy to clean and
maintain.
Actual Size: 14.4” x 11.6“ x 8.9”
Shipping Dim.: 16.5” x 13” x 10“
Net Weight: 22 lbs
Shipping Weight: 25 lbs
Specifications:
•
•
•
•
•
•
•
•
Horizontal Six place rotor for 2 to 10 ml tubes
Quiet at full speed, only 58 decibels
Stainless Steel chamber for easy cleaning and disinfection
HX models run at fixed speed 3400 RPM
0-99 minute digital timer
Suction cup rubber feet add stability while reducing vibration
Lid window for strobe tachometer RPM check
One Year Limited Warranty
Item No.
C822
C822-01
C822-02
C800-03
C800-04
C800-34
Description
HX, 6 Place Horizontal Spin Centrifuge
6 Place Swing Out Rotor
Tube Shield, Pkg. of 2
Short Tube Adapters, for 4-7 ml tubes, Pk/10
Small Tube adapters, for 2 ml tubes, Pk/2
Microhematocrit Adapters, 4 tubes each, Pk/2
C822 Model HX Horizontal
Centrifuge
C800-34 Microhematocrit Adapters
High Technology, Inc.
www.htidiagnostics.com
(508) 660-2221
Walpole, MA USA
PowerSpin™ Centrifuges, DX
HTI® is proud to present the PowerSpin™ DX Centrifuge
With 4 rotor options this centrifuge is a great answer for
every day laboratory tasks.
- 24 place fixed rotor for 2-15ml tubes ( #C8724 )
- 6 place horizontal rotor for 2-15ml tubes ( #C8706 )
- 4 place horizontal rotor for up to 50ml tubes ( #C8704 )
- 4 place fixed rotor for 60ml syringes ( #C8760 )
The PowerSpin™ DX has variable speed 500 – 4000 RPM,
to ensure a clean and complete separation. Quiet and
dependable, with a maintenance free motor, it can be used
to process blood, urine, semen and other specimens.
Model #C8724
The all digital front panel makes it easy to select speed and run time. Oversized LCD
display shows status, time, speed (RPM) and RCF (g). Precise speed control enables you
to comply with CLIA recommendations for specific specimens.
• Zero RPM Safety Latching System prevents
lid from being opened while rotor is spinning
• Quiet running, only 50 decibels at 3400 RPM
• 99 minute digital timer , 1 sec increment
• 500-4000 RPM, 100 RPM increment
• Remembers last setting for quick repeat runs
• Adjustable Acceleration and Deceleration
• Stainless steel rotor chamber for easy cleaning
• Suction cup rubber feet eliminate vibration
•Available in 110V and 220V - Contact HTI for details
Professional Digital Non-Contact Photo-Tachometer
•
•
•
•
•
•
Highly accurate, scientific tool
Easy to operate
Standard adhesive reflective tape (included)
Aim and measure--RPMs instantly display on large LCD screen.
Includes custom protective cushioned storage case
Order pn# C800-75
High Technology, Inc.
www.htidiagnostics.com
(508) 660-2221
Walpole, MA USA
Model C8724
•
24 place fixed angle rotor ( pn#C8600-03 — rotor only)
•
Designed to accept 10ml blood tubes and up to 15ml urine tubes
•
2ml tubes with small tube adaptor (pn# C800-04 — set of 2)
•
5ml tubes with short tube adaptor (pn# C800-03 — set of 10)
Model C8706
•
6 place horizontal rotor ( pn#C8600-01 — rotor only)
•
Specifically designed to keep tubes vertical at rest
•
Designed to accept 10ml blood tubes and up to 15ml urine tubes
•
2ml tubes with small tube adaptor (pn# C800-04 — set of 2)
•
5ml tubes with short tube adaptor (pn# C800-03 — set of 10)
Model C8760
•
•
4 place fixed angle rotor ( pn#C8600-05 — rotor only)
Designed to accept 60ml Syringes
Model C8704
UNICO Model
Item
•
4 place horizontal rotor ( pn#C8600-02 — rotor only)
•
Designed to accept 50ml tubes
•
With adaptors can accept most of the tubes used in laboratory
•
6 to 15ml tubes with adaptor (pn# C8604-02 — set of 2)
•
3 to 5ml tubes with adaptor (pn# C8604-03 — set of 2)
•
0.5 to 2ml tubes with adaptor (pn# C8604-04 — set of 2)
Speed
Max. RCF
Rotor
Tube Size
Tube Holdster
24 place
PowerSpin™ DX
C8724
500 – 4000 RPM
2508
24 place fixed
2-15ml
Optional
PowerSpin™ DX
C8724H
500 – 4000 RPM
2508
24 place fixed
2-15ml
Included
PowerSpin™ DX
C8706
500 – 4000 RPM
2508
6 place horizontal
2-15ml
Optional
PowerSpin™ DX
C8706H
500 – 4000 RPM
2508
6 place horizontal
2-15ml
Included
PowerSpin™ DX
C8704
500 – 4000 RPM
2508
4 place horizontal
50 ml
Optional
PowerSpin™ DX
C8704H
500 – 4000 RPM
2508
4 place horizontal
50 ml
Included
PowerSpin™ DX
C8760
500 – 4000 RPM
2508
4 place fixed
60 ml
N/A
High Technology, Inc.
www.htidiagnostics.com
(508) 660-2221
Walpole, MA USA
PowerSpin™ Centrifuges, BX
PowerSpin™ Centrifuge, BX
The BX is a versatile, state of the art variable-speed centrifuge
series with three rotor options.
Options are:
• Blood/Urine Tube, 2-12 ml Rotor: Max Speed = 5,000 RPM
• Microhematocrit/Capillary Tube Rotor: Max Speed = 11,000 RPM
• Microcentrifuge Tube, 0.5-3 ml Rotor: Max Speed = 13,000 RPM
Your BX can be a dedicated centrifuge with any one of the rotors,
or a versatile addition to your lab with up to three
interchangeable rotors with speeds from 1,000 – 13,000 RPM.
BX Centrifuges have advanced safety features such as a Zero
RPM lid latch control system (which makes sure the lid can not be
opened if the rotor is spinning), a stainless steel rotor chamber,
Auto-unbalance detection and shut-down (will shut-down the motor
if an off-balance condition is detected). With three
interchangeable rotors, the centrifuge features ARD (Automatic
Rotor Detection), the unit can automatically tell which of the three
rotors are loaded. This is an important safety feature as each of
the three rotors has a different maximum speed.
The Microhematocrit rotor features a Tube Reader built-into the
rotor lid. This makers reading crit values quick and easy after
your run, without having to remove the tubes and place them in a
reader, or on a reader-card, etc. The standard Blood & Urine
tube rotor fits 7.5 – 12 ml tubes and will not accept 15 ml tubes.
With adapters shown below, you can spin 0.5 – 3 ml tubes
(C800-04), or 3.5 – 6.5 ml tubes (C800-03).
C881
Item No.
C881M
C881ME
C882
C882E
C883
C883E
C884
C884E
C885
C885E
C886
C886E
C887
C887E
C881-03
C881-04
C800-34
C8600-34
C800-512
C800-550
C800-500
Specifications:
•
•
•
•
•
•
•
•
•
Description
BX, 6 Place Fixed Angle Metal Rotor Centrifuge
BX, 6 Place, Fixed Angle Metal Rotor Centrifuge, 220V
BX, 24 Place Hematocrit Centrifuge
BX, 24 Place Hematocrit, same as above, 220V
BX, 24 Place Micro-Tube Centrifuge
BX, 24 Place Micro-Tube, same as above, 220V
BX, 6 Place Tube rotor & 24 Place Microhematocrit
BX, 6 Place Tube rotor & 24 Place Microhematocrit, 220V
BX, All three available rotors, 110V
BX, All three available rotors, 220V
BX, 24 Place Microhematocrit & 24 Place Microcentrifuge
BX, 24 Place Microhematocrit & 24 Place Microcentrifuge, 220V
BX, 6 Place Tube rotor & 24 Place Microcentrifuge
BX, 6 Place Tube rotor & 24 Place Microcentrifuge, 220V
Short Tube Adapters, for 4-7 ml tubes, Pk/10
Small Tube adapters, for 2 ml tubes, Pk/2
Adapters for four Microhematocrit tubes, Pk/2
Adapters for four Microhematocrit tubes, Pk/2
12 ml Conical Urine Tube, 16 x 100 mm, Pk/12
12 ml Conical Urine Tube, 16 x 100 mm, Pk/50
12 ml Conical Urine Tube, 16 x 100 mm, Pk/500
PowerSpin™
Model
Rotor radius
Fecal Speed
Fecal Time
Urine Speed
Urine Time
Blood Speed
Blood Time
BX
C881
92 mm
RPM
RCF
1600
263
10 minutes
2000
411
5 minutes
5000
2570
4 minutes
Variable speed up to 13000 RPM (up to 5000 RPM on C881)
Zero RPM Safety Lock and Rotor Unbalance Sensor
Automatic Rotor recognition
Digital Timer 0-99 minutes
Maintenance free brushless motor
Exterior is chemical resistant and easy to clean and disinfect
Lid window for strobe tachometer RPM check
Standard 115V/60Hz; (220V/50Hz option available)
One Year Limited Warranty
Digital LCD display and push button
control panel are designed to give the
user complete control throughout the
spin cycle.
• The “Open” button is disengaged while
the rotor is in motion
• LCD mode button will adjust displayed
data according to your preferences
BX
C882
86 mm
RPM
RCF
N/A
N/A
13,000 16,250
5 minutes
RPM = Revolutions Per Minute
RCF = Relative Centrifugal Force (also known as “G-Force”)
High Technology, Inc.
www.htidiagnostics.com
(508) 660-2221
Walpole, MA USA
BX
C883
82 mm
RPM
RCF
N/A
2300
485
5 minutes
13,000 15,495
5 minutes
PowerSpin™ Centrifuges, BX
PowerSpin™ Centrifuge, BX
BX Versatility: New Microhematocrit Tube Adapters: We have developed several microhematocrit tube
adapters that can be used with the Blood & Urine Tube Rotor, making a single rotor much more
versatile and eliminating the need to purchase an additional rotor, or change rotors. Both New C80034 and C8600-34 Adapters come in a Pkg/2 adapters, each and each adapter holds up to 4 MH
tubes. The Blood & Urine rotor runs at a max of 5,000 RPM, much slower than traditional
microhematocrit rotors with a 5 min. run. With our adapters, at 5,000 RPM, you can achieve a
complete microhematocrit separation in an 8 min. run.
24 place rotor for 0.5 to 3ml Micro tubes
The BX’s large digital display continuously shows three parameters in real-time: Speed (RPM), g-Force
(RCF) and Time – how much time is left in the run. A unique feature allows the user to select which of
these three parameters to display in an extra large font, for quick and easy viewing.
BX’s feature maintenance-free brushless motors and a lid window for tachometer calibration checks.
An intuitive button panel is quick and easy to use.
BX Rotors and
Acrylic Rotor Rack
24 place rotor for capillary
Microhematocrit tubes. Hematocrit
Reader incorporated into the cover
Select from three rotor options for your
BX centrifuge. For your convenience, we
designed the C880-10 BX Rotor Rack to
store all three rotors, the rotor changing
tool and all your accessories. This rack
can sit bench-top next to the BX, or can
be wall-mounted, whichever works best
for your lab. Also includes 18-place Tube
Holdster™ for any size tube from 2-15ml.
Item No.
C880-01M
C880-02
C880-03
C880-10
Description
Metal, 6-Place Blood/Urine
Tube Rotor
24-Place Microhematocrit Rotor
24-Place Microcentrifuge Rotor
BX Rotor Rack with
Tube Holdster™
6 place Blood/Urine Tube Rotor
(accepts maximum 12 ml urine tubes)
The BX Acrylic Rotor Rack organizes your rotors, rotor
changing tool, and accessories all in one compact unit.
CMH30 Microhematocrit Centrifuge
Model CMH30 is made of formed metal and has a baked paint
application that is acid and reagent resistant. A safety switch built
into the handle assembly disconnects the power to the motor
whenever the latch is lifted. The brushed motor is mounted on
rubber mounts to provide quiet running and dampen vibration.
Microhematocrit Tube Reader
included with CMH30
Specifications:
• Twenty-four (24) place rotor with replaceable rubber ring and screw
down metal lid
• Includes Microhematocrit Tube Reader
• Nominal speed is 12,000 RPM
• Dependable mechanical 5-minute timer with bell signal at end of run
• All metal housing for years of dependable use
• Safety switch in latch shuts off motor when lid is lifted
• Electric motor braking
• Indicator light tells when unit is in use
• Standard 115V/60Hz AC
• One Year Limited Warranty
Item No.
Description
CMH30
Microhematocrit Centrifuge, 24 Place, 110V
CMH30E
Microhematocrit Centrifuge, 24 Place, 220V
CMH30-Reader Microhematocrit Tube Reader
Actual Size: 11.6” x 10.3“ x 9.3”
Shipping Dim.: 12.7” x 12.7” x 12.2“
Net Weight: 17.4 lbs
Shipping Weight: 19.4 lbs
High Technology, Inc.
www.htidiagnostics.com
CMH30 Centrifuge