PRODUCT INFORMATION PROCESS ANALYSIS AMPEROMETRIC SENSORS Smart amperometric free chlorine, chlorine dioxide and ozone sensors ➔ Stable measuring results thanks to flow optimisation ➔ Premounted flow cell, easy to install ➔ Special accessories for optimal operation ➔ Compatible with multi-parameter digital SC controllers ➔ Minimal maintenance with automatic cleaning Simple installation and operation The all-inclusive systems come preassembled on a panel. Just mount the panel in the desired location, install the sensors, and connect the controller to get started. There are no chemicals used for measurement. Membranes are premounted on retaining caps so the maintenance and the operational costs are minimal. Two years of typical maintenance items are included with the system. Options for optimised operation For all amperometric sensors several accessories are available: ➔ Acidification unit This can be used for sample pH adjustment or for cleaning. It is fully programmable. ➔ Intermittent flow unit This free programmable unit reduces the amount of sample water which is sent to waste. PROCESS ANALYSIS_AMPEROMETRIC SENSORS Free chlorine Low detection limit for efficient residual chlorine monitoring The 9184 sc amperometric free chlorine sensor has a detection limit of 5 ppb or 0.005 mg/l hypochlorous acid (HOCl). Together with pH and temperature measurements, free chlorine concentration is calculated using dissociation curves stored in the instrument. Wide measurement range Due to its 0 to 20 ppm measurement range, the 9184 sc free chlorine sensor is particularly useful for drinking water distribution monitoring, chlorination applications, demineraliser systems or cooling water processes. Three forms of chlorine Measurements are made continuously by the sensor and reported to the controller. Depending on model, the 9184 sc sensor can measure: ➔ Hypochlorous acid (HOCl) only ➔ HOCl via acidification ➔ Total free chlorine (TFC) by measuring temperature and pH together with HOCl to calculate hypochlorite ions (OCl–). HOCl combined with OCl– equals total free chlorine. Fig. 1: Dissociation curve Active chlorine operations Active chlorine (HOCl) or hypochlorous acid is a powerful disinfectant – up to 100 times more efficient than hypochlorite ions. ➔ Total free chlorine (TFC) is composed of dissolved chlorine (at low pH values), hypochlorous acid gas, and hypochlorite ion (ClO–) coexisting in the sample. Their relative proportion depends on pH and temperature (see figure 1 above). ➔ Total combined chlorine (TCC) results from the addition of total free chlorine and chloramines (mono-, diand tri-chloramines).* * 9184 sc does not measure TCC. Ozone Wide measurement range with few interferences Bromine, chloramines, chlorine, chlorine dioxide, hydrogen peroxide, and pH do not interfere with ozone measurements when using the 9185 sc amperometric ozone sensor which can measure from 0 to 2 mg/l ozone. Ideal for low conductivity samples The 9185 sc ozone system has a low minimum detection limit of 0.005 mg/l ozone. And because the amperometric cell is separated from the sample by the membrane and is immerged into an electrolytic medium, the HACH LANGE – www.hach-lange.com 9185 sc ozone sensor is suitable for use in water with low conductivity. Ozone operations Ozone is highly soluble in water – up to 13 times more soluble than oxygen. Ozone is also highly unstable in water with stability decreasing with increasing temperature. Ozone reacts with hydroxide ions (OH–). As the concentration of OH– increases (pH increases), reaction with ozone increases (see figure 2). The hydroxide ion OH– is a by-product of Fig. 2: Time of breakdown (mn) of dissolved ozone ozone breakdown in water and the reaction between OH– and O3 can be sustained until ozone is completely removed. PROCESS ANALYSIS_AMPEROMETRIC SENSORS Chlorine dioxide Selective membrane avoids interference from chlorine The 9187 sc amperometric chlorine dioxide sensor uses a membrane that is selective for chlorine dioxide molecules. There are no interferences from bromine, chlorine, or hydrogen peroxide. The only potential interference is from ozone, which is rarely present in water treated with chlorine dioxide. The oxidation potential of chlorine dioxide is 2.5 times higher than chlorine. It is relatively independent from the pH value and therefore suitable for disinfection of alkaline water. The electrochemical reaction and diffusion through the membrane are temperature dependent. The measurement cell contains a temperature sensor for automatic temperature compensation to prevent measurement errors. The sensor should be installed in an accessible location. It can be mounted on a flat, vertical surface (such as a panel, stand, etc.). It should allow for access for any checking or maintenance. Sample flow should meet the specifications on the last page. Note: The optional pH probe is used for the 9184 sc free chlorine TFC sensor only. HACH LANGE – www.hach-lange.com PROCESS ANALYSIS_AMPEROMETRIC SENSORS Technical data PARAMETER Measurement range Minimum detection limit Accuracy Response time Measurement interval Minimum flow rate Pressure range Sample temperature Temperature compensation Sample pH Measurement technology Interferences Mounting Connections Materials Controller Environmental ratings Dimensions 9184 sc - FREE CHLORINE 0 to 20 ppm (mg/l) as HOCI 5 ppb or 0.005 mg/l HOCl 2% or ±10 ppb HOCl, whichever is greater 9185 sc - OZONE 9187 sc - CHLORINE DIOXIDE 0 to 2 ppm (mg/l) O3 0 to 2 ppm (mg/l) as ClO2 5 ppb or 0.005 mg/l O3 10 ppb or 0.01 mg/l ClO2 3% or ±10 ppb O3, 5% or ±10 ppb ClO2, whichever is greater whichever is greater 90% in less than 90 seconds Continuous 14 l/h (200 to 250 ml/min) auto-regulated by flow through cell 0.1 to 2 bar in flow cell 2 °C to 45 °C Automatic over sample temperature range 4 to 8 (acidification unit available for – – pH greater than 8) Amperometric/membrane No interference from chloramines, No interference from bromine, Ozone chlorine dioxide and ozone interfere chloramines, chlorine, chlorine dioxide, with measurement or hydrogen peroxide Flat, vertical surface (panel, stand, etc.) Sample line: 1/4 inch O.D., drain line: 1/2 inch I.D. (supplied) Electrode: gold cathode/silver anode, measuring cell: acrylic, probe body: PVC SC 100 / SC 1000 Integrated IP 66/NEMA 4X 299 x 250 mm (11.77 x 9.84 inch) Subject to change without notice. Ordering information * Required when the length of cable between the digital sensor and SC 100 or SC 1000 controller exceeds 100 m. HACH LANGE Services On-site support by our technical field staff. Quality assurance, complete with standard solutions, instrument checks and test solutions. www.hach-lange.com – up to date and secure, with downloads, information and shop. DOC063.52.00441.Jun07 DESCRIPTION ART. NO. 9184 sc free chlorine HOCl sensor LXV430.99.00001 9184 sc free chlorine TFC sensor LXV432.99.00001 9185 sc ozone sensor LXV433.99.00001 9187 sc chlorine dioxide sensor LXV434.99.00001 ACCESSORIES Digital extention cable 1 m (other lenghts available) 61224-00 Digital termination box* 58670-00 9180 sc acidification unit LZY051 9180 sc intermittent flow unit LZY052 REPLACEMENT PARTS pH electrode Z368416,00000 9184 sc electrode Z09184=A=1001 - Premounted membranes, qty. 4 Z09184=A=3500 - Electrolyte Z09184=A=3600 9185 sc electrode Z09185=A=1000 - Premounted membranes, qty. 4 Z09185=A=3500 - Electrolyte Z09185=A=3600 9187 sc electrode Z09184=A=1001 - Premounted membranes, qty. 4 Z09187=A=3500 - Electrolyte Z09187=A=3600
© Copyright 2025 Paperzz