Fortfiber SWE PROPERTIES Fortfiber SWE are made of low carbon, cold drawn steel fibres used for a cost effective reinforcement of concrete Fortfiber SWE are deformed (waving) to guarantee (anchoring) good adherence to the concrete Fortfiber SWE guarantee a fast and easy mixing with no clogging. The 3-dimensional reinforcement of the steel fibers allows for thinner walls. For floors: reduction of application time: not necessary to install reinforcement mesh, no sub-floor needed, pouring of concrete directly out of the concrete truck without a concrete pump, reduction of amount of saw cut joints. CHARACTERISTICS USES To allow high loads on normal concrete (B25 and B35): industrial floors, prefab elements, waterproof basements, increasing the load capacity by dividing forces. To give concrete extra ductility. To replace or minimise static reinforcement; or can replace reinforcement that is difficult to install: f.e. for gunite or shotcrete in tunnels. High energy-absorption by dynamic loads: or increase impact resistance. Steel fibers distributed over the total concrete thickness give excellent crack resistance; the areas closest to the surface are also reinforced resulting in less damage to corners or sides. Reduced crack formation during sudden temperature changes. To prevent cracks in walls which are poured on top of existing Floor slabs. Material: Length : Fiber width Fiber thickness Amount Type 35 Type 50 E-modulus Tensile strength Shape cold drawn steel wire 35 and 50 mm 2 mm 0,6 mm 3.000 per kg 2.000 per kg 210 MPa 1000 MPa flat waving FORTIUS, BK International, Grasbos 50, B-3294 Diest, Belgium Tel: + 32 13 326873 Fax + 32 13 326874 e-mail: [email protected] TYPES Fortfiber SWE 35 Fiber length l: Fiber thickness d: Fiber width b: 35 ( 1) mm 0,6 ( 0,05) mm 2 ( 0,1) mm Fortfiber SWE 50 Fiber length l: Fiber thickness d: Fiber width b: 50 ( 1) mm 0,6 ( 0,05) mm 2 ( 0,1) mm APPLICATION Reinforced concrete with Fortfiber SWE can be poured directly out of the mixer. When pumping the fiber reinforced concrete, it is not allowed to have dosage higher then 50 kg/m³ PACKAGING 25 kg per cardboard box, 40 boxes on a pallet . DOSAGE Fortfiber SWE can be added by hand or blown directly into the fast rotating mixer or into the truck mixer. It is not allowed to add more then 25 kg of fibers per minute. Mixing should be at least 2 minute per m³ of concrete. Compliance with ASTM A 820/A 820M-04, Type V cold drawn wire. Testing conforms with ASTM C 1116, ASTM C1018 and JCI SF4. The published values are for information only and give no warranty. B.K.International does not take any responsibility resulting of the use of these properties. See also: www.fortius.be The right proportioning of Fortfiber SWE is determined by static claculations or by basic recommendations. A possible deviation of the mix design should be adjusted by addition of proper plastifier. Normal recommended dosage is 25 kg/m³. All additives need to be free of Chlorides. Can be used as reinforcement in screeds.. FORTIUS, BK International, Grasbos 50, B-3294 Diest, Belgium Tel: + 32 13 326873 Fax + 32 13 326874 e-mail: [email protected]
© Copyright 2026 Paperzz