4D-1000
Commercial Heavy Duty Battery
Crown Battery’s lineup of commercial heavy-duty equipment batteries
deliver uncompromising power. With heavy-duty outboard lug and framed
plates, rugged through-the-partition inner-cell connections,
heavy-duty
cast-on straps and envelope separators, Crown commercial batteries deliver reliable high performance starting and reserve power. Combine that
with our maintenance-free design and you have a battery that’s going to
last longer and perform like no other.
The 4D-1000 commercial battery is specifically built for on and off-road
applications such as wheel loaders, track loaders, excavators, aerial
cranes, buses and stationary engine systems.
Cover Style:
BCI Group Number:
Length
Physical
Characteristics:
Case & Cover Material:
4D
Heat Seal
Inner-Cell Connector Type:
Through Partition Weld
524 mm
Width
8.63”
219 mm
Height
10.00”
254 mm
Plate to Collector Bar
Fusion Method:
100 Lbs
45 Kgs
Plates per Battery:
Type A
Positive Grid Material:
Positive Grid Design:
Standard Terminal:
Positive Plate Dimension:
Negative Grid Material:
Nominal Voltage:
12 Volts
Engine Cranking Power:
Reserve Capacity Minutes:
Amp Hour
Capacity:
Charging
Specifications
1000 CCA
1250 CA
300 Min’s @ 25 Amps
Negative Grid Design:
Negative Plate Dimension:
Separator Type:
20 Hour Rate
7.0 A
140 Ah
Terminal Initial Torque:
10 Hour Rate
13.2 A
132 Ah
Electrolyte Volume:
5 Hour Rate
25.0 A
125 Ah
Float Charging
13.50 VDC @ 80°F
Max. Charging
15.30 VDC / 75 Amps
Black Polypropylene
Case to Cover Seal Method:
20.63”
Wet Weight
Exposed Vent Opening
Inverted Automatic
Cast-On Strap
114 Plates
Calcium Tin Lead Alloy
Split Radial
5.625” x 5.250” x 0.070”
143 mm x 133 mm x 1.8 mm
Calcium Tin Lead Alloy
Radial
5.625” x 5.250” x 0.060”
143 mm x 133 mm x 1.5 mm
Polyethylene Envelope
50 - 70 in-lbs / 5.6 - 7.9 N-m
4.0 Gallons / 15.1 Liters
Electrolyte Spec. Gravity:
1.275
Recommended Shelf Life:
6 Months Before Recharge
Visit our Website at
www.crownbattery.com
4D-1000 Commercial Heavy Duty Battery
Crown Battery Manufacturing’s team of research and development engineers welcome the
opportunity to discuss your technical requirements during the design and specification stage. To
access this technical assistance, please contact Crown Battery Manufacturing’s Customer Service
Department at 800.487.2879 / [email protected] / FAX 419.334.7124.
In Canada, contact Crown Battery of Canada Ltd at 905-850-8753 / [email protected]
4D-1000 CAD
All dimensions in inches and [millimeters]. All dimensions are for reference only.
Contact a Crown Battery representative for complete dimensional information.
Application & Handling Notes
State-of-Charge Specification
CAUTION: All lead acid batteries generate hydrogen
gas, which is highly flammable. If ignited by a flame
or spark, the gas may explode violently. When
working near batteries, always wear safety glasses,
remove watches or jewelry, and avoid causing sparks
with tools.
Battery
Charge
Percentage
Specific
Gravity
80°F / 27°C
Open
Circuit Voltage
80°F / 27°C
100%
1.275
12.75
Battery electrolyte is corrosive and can cause
blindness or severe burns. If exposed to battery
electrolyte, immediately flush with water and seek
medical attention.
75%
1.225
12.45
50%
1.200
12.20
Do not over-tighten terminals. Over-tightening can
result in post breakage, post meltdown or fire.
25%
1.155
12.06
Do not tip a battery beyond a 45° angle in any
direction.
This would allow electrolyte to push
through the battery vent assembly.
Discharged
1.120
11.89
The Power Behind Performance
Data are nominal and should not be construed as maximum or
minimum values for specification or for final design. Data for this
product type may vary from that shown herein.
© Copyright, Crown Battery Manufacturing Company 2006
TDS-20-1240-1206