Identify contamination

CONTAMINATION DETECTION
Fragment Analyzer ™ Automated CE System
Identify contamination
in nucleic acid samples.
See unwanted RNA in your genomic DNA extractions
Research labs now performing gDNA analysis should be aware that RNA contamination may be
present in their samples. With extraction methods varying from lab to lab, the latent possibility of
co-extracted RNA could interfere with downstream experiments.
The Fragment AnalyzerTM allows you to see this problem before proceeding to the next step.
Despite the presence of contaminants, the Fragment AnalyzerTM still clearly identifies the intact
gDNA both qualitatively and quantitatively.
394 350 -
Alignment Marker
300 20000
250 -
10000
5000 7000
3000 4000
1500 2000
1000
RFU
200 150 -
700
100 -
400
200
50 -
300
75
20000 -
Size (bp)
1500 2000 3000 4000 5000 7000 10000 -
1000 -
700 -
500 -
200 -
300 400-
75 -
1-
0-
1
500
Human genomic DNA sample spiked with total RNA (top trace) or messenger RNA (bottom trace). RNA contamination is
observed as peaks or smears in the size region from 50 to 1000bp. Note that alignment marker at far left is set to 1bp. The intact
gDNA can be found in the 20,000bp region. The corresponding digital gel image is shown to the right of the electropherogram.
ADVANCED ANALYTICAL > WWW.AATI-US.COM
Fragment Analyzer ™ AUTOMATED CE SYSTEM
Advanced Analytical
See unwanted gDNA in your RNA extractions.
RNA research is the new frontier of discovery in life science. Labs that once analyzed
dozens of RNA samples a week may now analyze hundreds or even thousands. With
these increased volumes, it’s important to ensure RNA experiments can proceed with
confidence by knowing there are no genomic DNA contaminants in the RNA extraction.
The Fragment AnalyzerTM accomplishes that.
6000
4000
3000
2000
1500
1000
500
200
20
6000
4000
3000
2000
1500
1000
500
200
20
TM
Human heart total RNA electropherograms measured by the Fragment Analyzer . Top panel shows RNA sample without gDNA;
bottom panel shows gDNA contamination in the peak to far right. Blue peak corresponds to the 28S region; red peak corresponds to
18S region.
Advanced Analytical Technologies, Inc.
Advanced Analytical Technologies, GmbH.
2711 South Loop Drive, Suite 4150
Ames, IA 50010 USA
Phone: +1-515-296-6600
Fax: +1-515-294-7141
E-mail: [email protected]
www.aati-us.com
Im Neuenheimer Feld 583
D-69120 Heidelberg
Phone: ++49 6221 868058-20
Fax: ++49 6221 868058-99
E-mail: [email protected]
www.aati-de.com
Copyright © 2013 Advanced Analytical Technologies, Inc. All Rights Reserved. Reproduction, adaptation or translation without prior written permission is prohibited, except as allowed under copyright laws.
Fragment Analyzer™ Automated CE System is a trademark of Advanced Analytical Technologies, Inc.