Limited Warranty Condux International, Inc. extends the following warranty to the original purchaser of these goods for use, subject to the qualifications indicated: Condux International, Incorporated warrants to the original purchaser for use that the goods or any component thereof manufactured by Condux International will be free from defects in workmanship for a period of one year from the date of purchase, provided such goods are installed, maintained, and used in accordance with Condux’s written instructions. Components not manufactured by Condux International but used within the assembly provided by Condux International are subject to the warranty period as specified by the individual manufacturer of said component, provided such goods are installed, maintained, and used in accordance with Condux’s and the original manufacturer’s written instructions. Condux’s sole liability and the purchaser’s sole remedy for a failure of goods under this limited warranty, and for any and all claims arising out of the purchase and use of the goods, shall be limited to the repair or replacement of the goods that do not conform to this warranty. To obtain repair or replacement service under the limited warranty, the purchaser must contact the factory for a Return Material Authorization (RMA). Once obtained, send the RMA along with the defective part or goods, transportation prepaid, to: Condux International, Inc. 145 Kingswood Drive Mankato, MN 56002 THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE. CONDUX ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY. CONDUX WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Condux International, Inc. • P.O. Box 247 • 145 Kingswood Drive • Mankato, MN 56002-0247 USA 1-507-387-6576 • 1-800-533-2077 • FAX 1-507-387-1442 Internet: http://www.condux.com • e-mail: [email protected] © Copyright 2009, Condux International, Inc. Printed in USA Literature Part Number: 08917089 Revision Number: 2.6 USER GUIDE USER GUIDE USER GUIDE Reusable Power Eye Installation Procedure 1. Remove the specified length of cable jacket, insulation, etc. (See Table 1). CAUTION: Do not cut into the wire conductors or the pulling eye may fail prematurely. (Figure 1.) 2. Slide the sleeve nut over the exposed wire conductors as far as possible. (Figure 2.) 3. Spread the wire conductors apart, and insert the tapered plug into the center. (Figure 3.) 4. Use an Allen Wrench to screw the tapered plug into the wire conductors, until it is flush with the ends of the conductors. (Figure 4.) 5. Use a hammer to close the wire conductors around the tapered plug. (Figure 5.) 6. Thread the swivel head, eye socket, or clevis socket firmly onto the sleeve nut. Attach the pulling eye to a multiple pulling harness or winch line. (Figure 6.) Removal Procedure 1. Use a hacksaw to cut through the wire conductors directly behind the sleeve nut. 2. Use a hammer to drive the wire conductors through the sleeve nut and back into the swivel head, eye socket, or clevis socket. 3. Remove the swivel head, eye socket, or clevis socket from the sleeve nut and remove the tapered plug from the wire conductors. ADVERTENCIA Instrucciones de Operación Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Conductor Size Pulling Eye Color 2500 kcmil 2000 kcmil 1750 kcmil 1500 kcmil 1250 kcmil 1000 kcmil 750 kcmil 700 kcmil 600 kcmil 500 kcmil 400 kcmil 350 kcmil 250 kcmil 4/0 AWG 2/0 AWG 1/0 AWG Green Red Yellow Black Blue Orange Brown Gray Green Yellow Black White Blue Green Black Red Remove this Amount of Jacket 51⁄4” 5” 43⁄4” 45⁄8” 41⁄2” 41⁄2” 41⁄4” 33⁄4” 31⁄2” 33⁄8” 31⁄8” 3” 27⁄8” 21⁄2” 21⁄2” 21⁄4” 133 mm 127 mm 121 mm 117 mm 114 mm 114 mm 108 mm 95 mm 89 mm 86 mm 79 mm 76 mm 73 mm 64 mm 64 mm 57 mm Allen Wrench Size ⁄16” ⁄16” 5 ⁄16” 5 ⁄16” 5 ⁄16” 5 ⁄16” 5 ⁄16” 5 ⁄16” 5 ⁄16” 1 ⁄4” 1 ⁄4” 1 ⁄4” 3 ⁄16” 3 ⁄16” 3 ⁄16” N/A 5 5 Table 1. !WARNING: Read and understand all procedure and safety instructions before using any Condux® Reusable Power Pulling Eye. Failure to do so may result in personal injury or property damage. Save this user’s guide for future reference. !WARNING: The Condux Reusable Power Pulling Eye is for cable stringing or pulling only. Do not use it for any other purpose or severe personal injury and property damage could result. !ADVERTENCIA: Favor de leer y comprender todas las instrucciones de operación y seguridad antes de usar el Condux® Reusable Power Pulling Eye. Si Ud. no comprende las instrucciones favor de consultarle a su jefe. !WARNING: Do not stand directly behind the pull string. If any component breaks, severe personal injury or property damage could result. !CAUTION: Wear personal protective equipment: hard hat, safety glasses, safety shoes, and leather work gloves. Failure to do this could result in personal injury !WARNING: Do not exceed the load capacity of the Condux Reusable Power Pulling Eye or any element in the pull string. Severe personal injury or property damage could result.
© Copyright 2026 Paperzz