EXPS Extruded Polystyrene Foam Boards XPS Main applications Floors Industrial floors and cold rooms Ballasted or paved flat roofs Roof gardens Thermal insulation board of Polystyrene Foam extruded in a single layer Micro-ventilated pitched roofs Main aplication Thermal insulation of flat, pitched and inverted roofs, cavities, residential and industrial floors. Cladding insulation, house wraps, ground and/or Roof Garden insulation. Pitched Roofs Specification wording The thermal insulation shall consist of a layer of ISOLPARMA XPS extruded polystyrene foam boards. Thermal conductivity lD of .... W/mK according to UNI EN 13164. Board size mm ... x ... , thickness mm.... Sizes and packaging The boards are supplied with the following profiles: V type with sharp edge L type with lap joint edges TG type with tongue and groove edges Cavities CE marking Extruded Polystyrene Foam Insulation (XPS) The V and L, are supplied in a standard size of 600 x 1250 mm, TG type boards are size 600 x 2800 mm. The boards are packed in shrink wrap PE foil. Quantities per package vary with thickness (see table overleaf). Isolparma Srl - Via Mezzavia 134 - 35020 Due Carrare (PD) - Italy - tel +39 049 9126213 fax +39 049 9129616 www.isolparma.it EXPS Extruded Polystyrene Foam Boards XPS TECHNICAL DATA SHEET Properties Code UNI EN 13164 Norm Description Density mm 20 mm 30, 40 from mm 50 to 120 mm 20 mm 30 mm 40 mm 50 mm 60 mm 80 mm 100 mm 120 mm 20 mm 30 from mm 40 to 120 linear variation variation in thickness XPS Unit 30 ± 5% kg/mc 0,031 0,034 0,036 0,65 0,88 1,18 1,39 1,37 2,22 2,78 3,33 150 200 300 2 2 Declared heat conductivity lD UNI EN 12667 value measured at a mean temperature of 10 °C Declared heat resistance RD UNI EN 12667 related to thickness RD=d/lD Resistance to compression CS (10/Y) UNI EN 826 compression to 10% of thickness DS(TH) UNI EN 1604 euroclass UNI EN 13501-1 E UNI EN 12524 1200 J/(KgK) 100 - 200 m Dimensional stability Fire rating Specific heat Resistance to water vapour diffusion MU UNI EN 12086 Water absorption by diffusion WD(v)5 UNI EN 12088 Water absorption by immersion WL(T)0,7 UNI EN 12087 T1 UNI EN 823 Thickness tolerance test conditions: 48 h, 70 °C, 90% RH depending on surface after 28 days, with moisture gradient 0%-100% between board sides and test temperature 50°C dN = 50 mm <3 dN = 100 mm <3 < 50 from 50 to 120 > 120 Using temperature W/mK (m2K)/W KPa % % % volume > 0,5 % volume ± 2,0 +3,0 / -2,0 +8,0 / -2,0 mm 75 °C Sizes and packaging V type with sharp edge L type with lap joint edges TG type with tongue and groove edges thickness mm board size mm p.cs/package m2/package packages/pallet 20 30 40 50 60 70 80 thickness mm 30 40 50 60 70 80 thickness mm 30 40 600 x 1250 600 x 1250 600 x 1250 600 x 1250 600 x 1250 600 x 1250 600 x 1250 board size mm 600 x 1250 600 x 1250 600 x 1250 600 x 1250 600 x 1250 600 x 1250 board size mm 600 x 2800 600 x 2800 20 14 10 8 7 6 5 p.cs/package 14 10 8 7 6 5 p.cs/package 14 10 15,00 10,50 7,50 6,00 5,25 4,50 3,75 m2/package 10,50 7,50 6,00 5,25 4,50 3,75 m2/package 23,52 16,80 12 12 12 12 12 12 12 packages/pallet 12 12 12 12 12 12 packages/pallet 12 12 Technical Data Sheet issued in November 2007 Isolparma Srl - Via Mezzavia 134 - 35020 Due Carrare (PD) - Italy - tel +39 049 9126213 fax +39 049 9129616 www.isolparma.it
© Copyright 2026 Paperzz