Key Existing road lighting column to be removed Quantity 5 LA Existing LA cable to be removed LA Existing Feeder Pillar to Remain Quantity 1 M Quantity 5 LA CSoec ur on t d 67 to 65 DW Windsor Manhattan MAN 60 W B Tilt: N/A 6m Steel 60W CPO-TW Telensa (HF-Dali Ballast) RAL 7001 (Silver Grey) Proposed LA Cable in Orange Duct. LA LAYOUT 1: LION YARD CONTRACT REQUIREMENT: 1. DESIGN TO LIGHTING CLASS CE4 CONTRACT CHANGE REQUEST: 3 1. REPLACE EXISTING LIGHTING COLUMNS WITH NEW INCORPORATING DW WINDSOR MANHATTAN LANTERNS. DESIGN NOTES: First Court M LA 's ur t Co br ar y LA LA LA LA LA LA LA LA LA LA Li LA LA LA LA LA LA LA LA LA FP1 LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA LA V39 LA LA LA LA LA LA LA 9 LA LA LA LA V3 LA it M du LA on ard CC3 L2QGD M LA V C n's so 39 V39 b Ho nY CC2 L1QGD LA LA LA LA 9 LA V3 Lio Church of St Andrew's The Great LA 21 LA LA LA V39 CC1A L4QGD M LA V39 OTHER LA LA LA CC4 L3QGD a 12 Lion House 9 LA LA LA War Meml V3 ury C y t Pet 9 to 29 BANNERS CC6 L5QGD 21 28 SOCKETS Ch ris t V39 V39 to 27 EXISTING COLUMNS SPECIFICATION ate to 25 we ll G of) La ne (sit e 23 1 8.5m 26 to 1. THIS ROAD ACHIEVES LIGHTING CLASS CE4 Bar n 14 4 LA LA LA LA LA LA LA LA LA V39 to 2 9 1 V3 12 to V39 35 68 30 LA M LA LA LA 9 V39 ace Tel Ex St ws dre An e) Po ov H ead (ab 62 ice ff st O 59 64 Sta to El Sub 63 1 o1 9t 8 7 nk Ba 66 P e ffic O t os r Ter o (ab y rar Lib ve) Lion Yard 8 to 9 IMAGE 1: DW WINDSOR MANHATTEN LANTERN Lantern: Lantern Optic: Column: Lamp: Control: Colour Spec: e us Ho THIS SCHEME IS CMS CONTROLLED Rev B Schedules added to drawing as per CCC comments. Designer Date RO 28/05/15 Notes * EXISTING DTC CABLE SYSTEM TO REMAIN AND BE ELECTRICALLY TESTED AND INSTALLED TO CURRENT BS7671 REQUIREMENTS. WARNING - THERE ARE BURIED SERVICES WITHIN THIS SCHEME. REFER TO DIG PACK PRIOR TO REMOVAL / INSTALL AND ENSURE DIG PACK CONTAINS ALL THE INFORMATION COPYRIGHT RESERVED BALFOUR BEATTY LIVING PLACES IS THE OWNER OF THE COPYRIGHT SUBSISTING IN THESE DRAWINGS, PLANS, DESIGNS AND SPECIFICATIONS. THEY MUST NOT BE USED, REPRODUCED OR COPIED, IN WHOLE OR IN PART, NOR MAY THE INFORMATION, IDEAS AND CONCEPTS THEREIN CONTAINED (WHICH ARE CONFIDENTIAL TO BALFOUR BEATTY LIVING PLACES) BE DISCLOSED TO ANY PERSON WITHOUT THE PRIOR SPECIFIC WRITTEN CONSENT OF BALFOUR BEATTY LIVING PLACES. Designer Date of issue 28/11/14 CB Checked CB Authorised Sheet Size Scale NB A1 1:500 @ A1 Issue CONSTRUCTION Revision B Drawing no. 7200-D39 Scheme Name and Ward: DESIGNATED DESIGNS, CAMBRIDGE Streets on drawing: LION YARD Sheet 1 of 1
© Copyright 2026 Paperzz