Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 Dimensional Drawings 3051 Exploded View Certification Label Span and Zero Adjustments(1) (Standard) Electronics Housing Terminal Block Cover O-ring Cover Electronics Board Nameplate Sensor Module Housing Rotation Set Screw (180° Maximum Housing Rotation without Further Disassembly) Coplanar Flange Drain/Vent Valve Process O-Ring Flange Adapter O-Ring Flange Alignment Screw (Not Pressure Retaining) Flange Adapters 3031B08A Flange Bolts 1) Span and Zero Adjustments are not available with fieldbus or profibus protocols. 17 Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 3051C Coplanar Flange Dimensional Drawing (Differential Pressure Transmitter Shown) 5.0 (127) 4.3 (110) 0.75 (20) Clearance for Cover Removal 0.75 (20) Clearance for Cover Removal 1/2–14 NPT Conduit Connection Conduit (Two Places, Connection Other (Two Sizes Places, Available) Other 4.1 (105) Terminal Connections Transmitter Circuitry 7.17.1 (181) (181 8.2 (209) Nameplate Drain/Vent Valve Certification Label Coplanar Flange Process Connection Per IEC 61518 2.126 (54) ±0.012 in. Connection Centers 6.4 (163) 3051-3031A06A, B06A Housing Rotation Set Screw ¼–18 NPT on Coplanar Flange for Pressure Connection without the Use of Flange Adapters 1 /2–14 NPT on Optional Flange Adapters. Adapters can be rotated to give connection centers of 2.00 (51), 2.126 (54), or 2.25 (57). Coplanar Flange Mounting Configurations with Optional Bracket (B4) for 2-in. Pipe or Panel Mounting 2.8 (72) 4.3 (110) PANEL MOUNTING 2.8 (71) 7.1 (181) 5 /16 ⫻ 11/2 Bolts for Panel Mounting (Not Supplied) 3 /8–16 × 11/4 Bolts for Mounting to Transmitter 6.2 (156) 2.8 (71) 1.1 (28) 3.4 (85) 4.8 (120) 6.0 (152) 3.3 (83) Dimensions are in inches (millimeters) 18 3051-3031A04H,I04A,M04A,L04A,J04A PIPE MOUNTING 2-inch U-Bolt for Pipe Mounting Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 Traditional Flange Mounting Configurations with Optional Brackets for 2-in. Pipe or Panel Mounting Traditional Flange Panel Mounting Bracket (option B2/B8) Traditional Flange 2-in. Pipe Mounting Bracket (option B1/B7/BA) 10.1 (257) 4.2 (106) Impulse Piping 2.7 (67) 1.1 (28) 3051-3031J19D, I19C, E19C, C19A 3.8 (95) 5 /16 x 7/8 Bolts for Panel Mounting (Not Supplied) 9.6 (243) 2.7 (67) 6.2 (158) 2.81(71) 1.4 (33) PANEL MOUNTING BRACKET PIPE MOUNTING BRACKET 4.6 (116) Traditional Flange (Options H2–H7) Dimensional Drawing 5.0 (127) 4.3 (110) 0.75 (20) Clearance for Cover Removal 1 /2–14 NPT Conduit Connection (Two Places Other Sizes Available) Housing Rotation Set Screw Transmitter Circuitry Terminal Connections Certification Label 4.1 (105) 7.9 (202) Nameplate /4–18 NPT on Traditional Flange for Pressure Connection Without the Use of Flange Adapters. Connection Per IEC 61518 2.126 (54) ±0.12 in. Connection Centers 1.7 (43) 2.126 (54) /2–14 NPT on Optional Flange Adapters. Adaptors Can Be Rotated to Give Connection Centers of 2.00 (51), 2.126 (54), or 2.25 (57). Drain/ Vent Valve 1.1 (28) 3.4 (87) 1.1 (28) 3051-3031E30A, D30B 1 1 Dimensions are in inches (millimeters) 19 Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 3051T Dimensional Drawings 1 /2–14 NPT Conduit Connection (Two Places, Other Sizes Available) 5.0 (127) 4.3 (110) Certification Label 4.1 (105) 0.75 (20) Clearance for Cover Removal 0.75 (20) Clearance for Cover Removal Transmitter Circuitry Terminal Connections 7.2 (183) 3051-3051TC6A, TB6A Nameplate Housing Rotation Set Screw 3051T Typical Mounting Configurations with Optional Mounting Bracket Pipe Mounting Panel Mounting 4.3 (110) 2.9 (72) 5.1 (130) 2 (50) 6.2 (156) 2.8 (71) 3.5 (90) 6.3 (160) 4.8 (120) 6.9 (175) Dimensions are in inches (millimeters) 20 Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 3051H Pressure Transmitter Exploded View and Dimensional Drawings Secondary Filled System Sensor Module High Side Process Flange 3051-3051HB2G Process Isolating Diaphragm Low Side Process Flange Drain/Vent Valve Flange Bolts 1/2–14 NPT Conduit Connection (Two Places, Other Sizes Available) 5.0 (127) 4.3 (110) Transmitter Circuitry Certification Label 0.75 (19) Clearance for Cover Removal Terminal Connections Nameplate 9.0 (228) Housing Rotation Set Screw 10.8 (275) Drain/Vent Valve 1.2 (30) 1 1/2–14 /2–18 NPT on Process Flange for Pressure Connection Without the Use of Mounting Adapters 3.4 (86) 1.1 (28) NPT on Optional Mounting Adapters. Adapters Can Be Rotated to Give Adapter Connection Centers of 2.00 (51), 2.126 (54), or 2.25 (57). 3051-3051i01A, H01B 3051-3051TA4A, TB4A, TC4A 0.75 (19) Clearance for Cover Removal 4.1 (105) Dimensions are in inches (millimeters) 21 Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 3051H Mounting Brackets for 2-in. Pipe and Panel Mount (Option Code B5/B6) PIPE MOUNTING CONFIGURATIO Impulse Piping 2.7 (67) 0.7 (16) 4.4 (109) 2.7 (67) Dimensions are in inches (millimeters) 22 3051-3031G19A, F19B, 3051HB3A, HA3B 7 /16–20⫻3/4 Bolts Supplied for Attaching Bracket to Transmitter PANEL MOUNTING CONFIGURATION Impulse Piping Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 3051L Dimensional Drawings 2-in. Flange Configuring (Flush Mount Only) 3- and 4-in. Flange Configuration Certification Label Certification Label 4.1 (105) 4.1 (105) Serrated Face Gasket Surface Housing Rotation Set Screw E F E D Lower Housing Gasket A H A H Extension 2, 4, or 6 (51, 102, or 152) Optional Flushing Connection Ring (Lower Housing) G 1 /2–14 NPT Conduit Connections (optional) 5.0 (127) 4.3 (110) Transmitter Circuitry 0.75 (19) Clearance for Cover Removal Terminal Connections 0.75 (19) Clearance for Cover Removal F E 5.14 (131) 7.1 (181) 8.2 (209) Diaphragm Assembly and Mounting Flange B Nameplate C 1 /4–18 NPT on Flange for Pressure Connection without the Use of Mounting Adapters Drain/Vent Valve 3051-3031B27A, 27B, 27C, 3031B27D, C27E Flushing Connection Dimensions are in inches (millimeters) 23 Product Data Sheet 00813-0100-4001, Rev GA Catalog 2006 - 2007 Rosemount 3051 TABLE 10. 3051L Dimensional Specifications Except where indicated, dimensions are in inches (millimeters). Class ASME B16.5 (ANSI) 150 Pipe Size Flange Thickness A Bolt Circle Diameter B Outside Diameter C No. of Bolts Bolt Hole Diameter Extension Diameter(1) D O.D. Gasket Surface E 0.69 (18) 0.88 (22) 0.88 (22) 0.82 (21) 1.06 (27) 1.19 (30) 1.00 (25) 1.25 (32) 20 mm 24 mm 24 mm 20 mm 4.75 (121) 6.0 (152) 7.5 (191) 5.0 (127) 6.62 (168) 7.88 (200) 5.0 (127) 6.62 (168) 125 mm 160 mm 190 mm 180 mm 6.0 (152) 7.5 (191) 9.0 (229) 6.5 (165) 8.25 (210) 10.0 (254) 6.5 (165) 8.25 (210) 165 mm 200 mm 235 mm 220 mm 4 4 8 8 8 8 8 8 4 8 8 8 0.75 (19) 0.75 (19) 0.75 (19) 0.75 (19) 0.88 (22) 0.88 (22) 0.75 (19) 0.88 (22) 18 mm 18 mm 22 mm 18 mm NA 2.58 (66) 3.5 (89) NA 2.58 (66) 3.5 (89) NA 2.58 (66) NA 65 mm 89 mm 89 mm 3.6 (92) 5.0 (127) 6.2 (158) 3.6 (92) 5.0 (127) 6.2 (158) 3.6 (92) 5.0 (127) 4.0 (102) 5.4 (138) 6.2 (158) 6.2 (158) DIN 2501 PN 10/16 2 (51) 3 (76) 4 (102) 2 (51) 3 (76) 4 (102) 2 (51) 3 (76) DN 50 DN 80 DN 100 DN 100 Class Pipe Size Process Side F 1/4 NPT 1/2 NPT H 2 (51) 3 (76) 4 (102) 2 (51) 3 (76) 4 (102) 2 (51) 3 (76) DN 50 DN 80 DN 100 DN 100 2.12 (54) 3.6 (91) 3.6 (91) 2.12 (54) 3.6 (91) 3.6 (91) 2.12 (54) 3.6 (91) 2.4 (61) 3.6 (91) 3.6 (91) 3.6 (91) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 6.66 (169) 6.66 (169) 6.66 (169) 6.66 (169) 6.66 (169) 6.66 (169) 8.66 (219) 8.66 (219) 6.66 (169) 6.66 (169) 6.66 (169) 6.66 (169) ASME B16.5 (ANSI) 300 ASME B16.5 (ANSI) 600 DIN 2501 PN 10–40 DIN 2501 PN 25/40 ASME B16.5 (ANSI) 150 ASME B16.5 (ANSI) 300 ASME B16.5 (ANSI) 600 DIN 2501 PN 10–40 DIN 2501 PN 25/40 DIN 2501 PN 10/16 (1) Tolerances are 0.040 (1,02), –0.020 (0,51). 24 Lower Housing G
© Copyright 2026 Paperzz