Peripheral Embolization

Peripheral Embolization
Average Vessel Diameter
Peripheral Coiling Solved
A Trio of Technologies.
A Single Solution.
Hepatic, Gastro-Intestinal and Splenic Vasculature
Fathom® Steerable Guidewires
UPN
Order Number
Total Length
Tip Length
Proximal/Distal
O.D.
M00150 900 0
50-900
140 cm
10 cm
.016 in
M00150 901 0
50-901
140 cm
20 cm
.016 in
M00150 910 0
50-910
180 cm
10 cm
.016 in
M00150 911 0
50-911
180 cm
20 cm
.016 in
M00150 811 0
50-811
200 cm
10 cm pre-shaped
.014 in
M00150 810 0
50-810
200 cm
10 cm
.014 in
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
8-10 mm
6-8 mm
4-6 mm
5-8 mm
15-25 mm
6-8 mm
3-5 mm
1-3 mm
2-4 mm
1-3 mm
2-4 mm
2-4 mm
2-4 mm
3-5 mm
2-4 mm
Common Iliac Artery
External Iliac Artery
Internal Iliac Artery
Renal Vein
Vena Cava
Superior Mesenteric Artery
Inferior Mesenteric Artery
Intestinal Arteries
Superior Rectal Artery
Middle Sacral Artery
Inferior Epigastric Artery
Iliolumbar Artery
Lateral Sacral Artery
Superior Gluteal Artery
Inferior Gluteal Artery
2-4 mm
2-4 mm
2-4 mm
2-4 mm
2-4 mm
5-8 mm
2-4 mm
Male
A 1-3 mm
B 1-3 mm
39
40
41
42
43
44
45
Internal Pudendal Artery
Middle Rectal
Obturator Artery
Inferior Vesical Artery
Superficial Epigastric Artery
Femoral Artery
External Pudendal Artery
Testicular Arteries
Testicular Veins
Female
C 1-3 mm Ovarian Arteries
D 1-3 mm Ovarian Veins
E 2-4 mm Uterine Artery
Pelvic Vasculature
Renegade® STC 18 Microcatheters
STRAIGHT TIP
90 DEGREE ANGLED TIP
UPN
Order
Number
UPN
Order
Number
Usable/Distal
Length (cm)
M00118 125 0
18-125
M00118 127 0
18-127
105/20
3.0/2.4
.021/.021
M00118 126 0
18-126
M00118 128 0
18-128
105/30
3.0/2.4
.021/.021
M00118 131 0
18-131
M00118 133 0
18-133
130/20
3.0/2.4
.021/.021
M00118 132 0
18-132
M00118 134 0
18-134
130/30
3.0/2.4
.021/.021
M00118 137 0
18-137
M00118 139 0
18-139
150/20
3.0/2.4
.021/.021
M00118 138 0
18-138
M00118 140 0
18-140
150/30
3.0/2.4
.021/.021
Proximal/Distal Proximal/Distal
O.D. (F)
I.D. (in)
Interlock™ Fibered IDC™ Occlusion System
UPN
Order Number
Description
M001361500
36-150
2D Helical 3 mm x 6 cm
M001361510
36-151
2D Helical 3 mm x 12 cm
M001361520
36-152
2D Helical 4 mm x 8 cm
M001361530
36-153
2D Helical 4 mm x 15 cm
M001361540
36-154
2D Helical 5 mm x 8 cm
M001361550
36-155
2D Helical 5 mm x 15 cm
M001361560
36-156
2D Helical 6 mm x 10 cm
M001361570
36-157
2D Helical 6 mm x 20 cm
M001361580
36-158
2D Helical 8 mm x 20 cm
M001361590
36-159
2D Helical 10 mm x 20 cm
M001361600
36-160
2D Helical 10 mm x 30 cm
M001361610
36-161
2D Helical 12 mm x 20 cm
M001361620
36-162
2D Helical 12 mm x 30 cm
M001361630
36-163
2D Helical 14 mm x 20 cm
M001361640
36-164
2D Helical 14 mm x 30 cm
M001361740
36-174
VortX® Diamond 2/3 mm x 2.3 cm
M001361750
36-175
VortX® Diamond 2/4 mm x 4.1 cm
M001361760
36-176
VortX® Diamond 2/5 mm x 5.8 cm
M001361770
36-177
VortX® Diamond 2/6 mm x 8.0 cm
1
2
3
4
5
6
7
8
9
10
11
12
6-8 mm
5-7 mm
4-6 mm
3-5 mm
3-5 mm
4-6 mm
1-2 mm
2-4 mm
2-4 mm
5-8 mm
2-4 mm
2-4 mm
Celiac Trunk
Common Hepatic Artery
Proper Hepatic Artery
Right Hepatic Artery
Left Hepatic Artery
Gastroduodenal Artery
Cystic Artery
Right Gastroepiploic Artery
Left Gastric Artery
Splenic Artery
Left Gastroepiploic Artery
Right Gastric Artery
13
14
15
16
17
18
19
20
21
22
23
2-4 mm
6-8 mm
3-5 mm
1-3 mm
2-4 mm
2-4 mm
2-4 mm
2-4 mm
5-7 mm
1-3 mm
1-3 mm
Superior Pancreaticoduodenal Artery
Superior Mesenteric Artery
Inferior Mesenteric Artery
Phrenic Artery
Middle Colic Artery
Right Colic Artery
Ileocolic Artery
Left Colic Artery
Renal Artery
Intestinal Arteries
Sigmoid Arteries
Boston Scientific Corporation
One Boston Scientific Place
Natick, MA 01760-1537
www.bostonscientific.com
Key: 2 D Helical Coil Diameter (mm) x Restrained Length (cm)
VortX Diamond Small Secondary Coil Diameter (mm)/Large Secondary Diameter (mm) x Restrained Length (cm)
To order product or for more information,
contact customer service at 1.888.272.1001.
Anatomical illustrations are property of Boston Scientific Corporation. Anatomical illustrations and diameters created in collaboration with Dr. Gary Siskin, M.D. Illustrations are not necessarily to scale.
Prior to use, please see the complete 'Directions for Use' for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operator's Instructions. See reverse side for prescriptive information.
The vessel locations and diameters provided are intended to be representative of the average.
Due to anatomic variations across patients and pathologies, actual vasculature may differ significantly.
© 2010 Boston Scientific Corporation
or its affiliates. All rights reserved.
90527611 FEB10
FATHOM® STEERABLE GUIDEWIRE
Prior to use, please see the complete Directions for Use for more information on Indications,
Contraindications, Warnings, Precautions, Adverse Events and Operator‘s Instructions.
INDICATIONS FOR USE: The Fathom-14 and Fathom-16 Steerable Guidewire family
is intended for general intravascular use in the peripheral vasculature. It can be used to
selectively introduce and position catheters and other interventional devices within the
peripheral vasculature. This device should be used only by physicians trained in percutaneous,
intravascular techniques and procedures.
CONTRAINDICATIONS: This guidewire is not intended for use in the coronary vasculature.
ADVERSE EVENTS: Complications attributed to endovascular procedures are the following:
• Vessel trauma • Vessel damage • Embolism (catheter/device, air bubble, plaque, thrombus,
air embolism, thromboembolism) • Pseudoaneurysm • Seizure/stroke • Vessel dissection •
Hematoma at the puncture site • Nerve injury • Infection • Perforation of the vessel • Vessel
spasm • Hemorrhage • Vascular thrombosis • Vessel occlusion • Death • Bleeding • Failed
treatment • Inability to position guidewire • Damage to the catheter.
CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician.
INTERLOCK™ FIBERED IDC™ OCCLUSION SYSTEM
Prior to use, please see the complete Directions for Use for more information on Indications,
Contraindications, Warnings, Precautions, Adverse Events and Operator’s Instructions.
INTENDED USE/INDICATIONS FOR USE: The Interlock Fibered IDC Occlusion System is a
modified interlocking detachable coil indicated to obstruct or reduce rate of blood flow in the
peripheral vasculature. This device is not intended for neurovascular use.
CONTRAINDICATIONS: None known.
WARNING: Compatibility with magnetic resonance imaging (MRI) has not been established,
and the degree of imaging distortion resulting from the coil has not been measured.
ADVERSE EVENTS: Complications related to catheterization (e.g., hematoma at the site of
entry, clot formation at the tip of the catheter and subsequent dislodgement, nerve and vessel
dissection or perforation) • Pain • Hemorrhage • Infection necessitating medical intervention
• Foreign body reactions necessitating medical intervention • Emboli • Ischemia •
Vasospasm • Tissue necrosis • Undesirable clot formation of the vasculature • Claudication
• Recanalization • Death • Temporary neurological deficit.
CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician.
RENEGADE® STC-18 MICROCATHETER
Prior to use, please see the complete Directions for Use for more information on Indications,
Contraindications, Warnings, Precautions, Adverse Events and Operator‘s Instructions.
INDICATIONS FOR USE/INTENDED USE: The Renegade STC-18 Microcatheter is intended
for peripheral vascular use. The microcatheter can be coaxially tracked over a steerable
guidewire in order to access distal, tortuous vasculature. Once the subselective region has
been accessed, the microcatheter can be used for the controlled and selective infusion of
diagnostic, embolic or therapeutic materials into vessels. Diagnostic, embolic, therapeutic
agents to be used in accordance with specifications outlined by the manufacturer.
CONTRAINDICATIONS: None known.
ADVERSE EVENTS: The adverse events include, but are not limited to:
• Vessel trauma • Embolism • Hemorrhage/Hematoma • Vasospasm • Infection
• Air embolism • Allergic reaction.
PRECAUTIONS: This device should be used only by physicians thoroughly trained in
percutaneous, intravascular techniques and procedures.
CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician.
Boston Scientific Corporation
One Boston Scientific Place
Natick, MA 01760-1537
www.bostonscientific.com
To order product or for more information,
contact customer service at 1.888.272.1001.
© 2010 Boston Scientific Corporation
or its affiliates. All rights reserved.
90527611 FEB10