Peripheral Embolization Average Vessel Diameter Peripheral Coiling Solved A Trio of Technologies. A Single Solution. Hepatic, Gastro-Intestinal and Splenic Vasculature Fathom® Steerable Guidewires UPN Order Number Total Length Tip Length Proximal/Distal O.D. M00150 900 0 50-900 140 cm 10 cm .016 in M00150 901 0 50-901 140 cm 20 cm .016 in M00150 910 0 50-910 180 cm 10 cm .016 in M00150 911 0 50-911 180 cm 20 cm .016 in M00150 811 0 50-811 200 cm 10 cm pre-shaped .014 in M00150 810 0 50-810 200 cm 10 cm .014 in 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 8-10 mm 6-8 mm 4-6 mm 5-8 mm 15-25 mm 6-8 mm 3-5 mm 1-3 mm 2-4 mm 1-3 mm 2-4 mm 2-4 mm 2-4 mm 3-5 mm 2-4 mm Common Iliac Artery External Iliac Artery Internal Iliac Artery Renal Vein Vena Cava Superior Mesenteric Artery Inferior Mesenteric Artery Intestinal Arteries Superior Rectal Artery Middle Sacral Artery Inferior Epigastric Artery Iliolumbar Artery Lateral Sacral Artery Superior Gluteal Artery Inferior Gluteal Artery 2-4 mm 2-4 mm 2-4 mm 2-4 mm 2-4 mm 5-8 mm 2-4 mm Male A 1-3 mm B 1-3 mm 39 40 41 42 43 44 45 Internal Pudendal Artery Middle Rectal Obturator Artery Inferior Vesical Artery Superficial Epigastric Artery Femoral Artery External Pudendal Artery Testicular Arteries Testicular Veins Female C 1-3 mm Ovarian Arteries D 1-3 mm Ovarian Veins E 2-4 mm Uterine Artery Pelvic Vasculature Renegade® STC 18 Microcatheters STRAIGHT TIP 90 DEGREE ANGLED TIP UPN Order Number UPN Order Number Usable/Distal Length (cm) M00118 125 0 18-125 M00118 127 0 18-127 105/20 3.0/2.4 .021/.021 M00118 126 0 18-126 M00118 128 0 18-128 105/30 3.0/2.4 .021/.021 M00118 131 0 18-131 M00118 133 0 18-133 130/20 3.0/2.4 .021/.021 M00118 132 0 18-132 M00118 134 0 18-134 130/30 3.0/2.4 .021/.021 M00118 137 0 18-137 M00118 139 0 18-139 150/20 3.0/2.4 .021/.021 M00118 138 0 18-138 M00118 140 0 18-140 150/30 3.0/2.4 .021/.021 Proximal/Distal Proximal/Distal O.D. (F) I.D. (in) Interlock™ Fibered IDC™ Occlusion System UPN Order Number Description M001361500 36-150 2D Helical 3 mm x 6 cm M001361510 36-151 2D Helical 3 mm x 12 cm M001361520 36-152 2D Helical 4 mm x 8 cm M001361530 36-153 2D Helical 4 mm x 15 cm M001361540 36-154 2D Helical 5 mm x 8 cm M001361550 36-155 2D Helical 5 mm x 15 cm M001361560 36-156 2D Helical 6 mm x 10 cm M001361570 36-157 2D Helical 6 mm x 20 cm M001361580 36-158 2D Helical 8 mm x 20 cm M001361590 36-159 2D Helical 10 mm x 20 cm M001361600 36-160 2D Helical 10 mm x 30 cm M001361610 36-161 2D Helical 12 mm x 20 cm M001361620 36-162 2D Helical 12 mm x 30 cm M001361630 36-163 2D Helical 14 mm x 20 cm M001361640 36-164 2D Helical 14 mm x 30 cm M001361740 36-174 VortX® Diamond 2/3 mm x 2.3 cm M001361750 36-175 VortX® Diamond 2/4 mm x 4.1 cm M001361760 36-176 VortX® Diamond 2/5 mm x 5.8 cm M001361770 36-177 VortX® Diamond 2/6 mm x 8.0 cm 1 2 3 4 5 6 7 8 9 10 11 12 6-8 mm 5-7 mm 4-6 mm 3-5 mm 3-5 mm 4-6 mm 1-2 mm 2-4 mm 2-4 mm 5-8 mm 2-4 mm 2-4 mm Celiac Trunk Common Hepatic Artery Proper Hepatic Artery Right Hepatic Artery Left Hepatic Artery Gastroduodenal Artery Cystic Artery Right Gastroepiploic Artery Left Gastric Artery Splenic Artery Left Gastroepiploic Artery Right Gastric Artery 13 14 15 16 17 18 19 20 21 22 23 2-4 mm 6-8 mm 3-5 mm 1-3 mm 2-4 mm 2-4 mm 2-4 mm 2-4 mm 5-7 mm 1-3 mm 1-3 mm Superior Pancreaticoduodenal Artery Superior Mesenteric Artery Inferior Mesenteric Artery Phrenic Artery Middle Colic Artery Right Colic Artery Ileocolic Artery Left Colic Artery Renal Artery Intestinal Arteries Sigmoid Arteries Boston Scientific Corporation One Boston Scientific Place Natick, MA 01760-1537 www.bostonscientific.com Key: 2 D Helical Coil Diameter (mm) x Restrained Length (cm) VortX Diamond Small Secondary Coil Diameter (mm)/Large Secondary Diameter (mm) x Restrained Length (cm) To order product or for more information, contact customer service at 1.888.272.1001. Anatomical illustrations are property of Boston Scientific Corporation. Anatomical illustrations and diameters created in collaboration with Dr. Gary Siskin, M.D. Illustrations are not necessarily to scale. Prior to use, please see the complete 'Directions for Use' for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operator's Instructions. See reverse side for prescriptive information. The vessel locations and diameters provided are intended to be representative of the average. Due to anatomic variations across patients and pathologies, actual vasculature may differ significantly. © 2010 Boston Scientific Corporation or its affiliates. All rights reserved. 90527611 FEB10 FATHOM® STEERABLE GUIDEWIRE Prior to use, please see the complete Directions for Use for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events and Operator‘s Instructions. INDICATIONS FOR USE: The Fathom-14 and Fathom-16 Steerable Guidewire family is intended for general intravascular use in the peripheral vasculature. It can be used to selectively introduce and position catheters and other interventional devices within the peripheral vasculature. This device should be used only by physicians trained in percutaneous, intravascular techniques and procedures. CONTRAINDICATIONS: This guidewire is not intended for use in the coronary vasculature. ADVERSE EVENTS: Complications attributed to endovascular procedures are the following: • Vessel trauma • Vessel damage • Embolism (catheter/device, air bubble, plaque, thrombus, air embolism, thromboembolism) • Pseudoaneurysm • Seizure/stroke • Vessel dissection • Hematoma at the puncture site • Nerve injury • Infection • Perforation of the vessel • Vessel spasm • Hemorrhage • Vascular thrombosis • Vessel occlusion • Death • Bleeding • Failed treatment • Inability to position guidewire • Damage to the catheter. CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. INTERLOCK™ FIBERED IDC™ OCCLUSION SYSTEM Prior to use, please see the complete Directions for Use for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events and Operator’s Instructions. INTENDED USE/INDICATIONS FOR USE: The Interlock Fibered IDC Occlusion System is a modified interlocking detachable coil indicated to obstruct or reduce rate of blood flow in the peripheral vasculature. This device is not intended for neurovascular use. CONTRAINDICATIONS: None known. WARNING: Compatibility with magnetic resonance imaging (MRI) has not been established, and the degree of imaging distortion resulting from the coil has not been measured. ADVERSE EVENTS: Complications related to catheterization (e.g., hematoma at the site of entry, clot formation at the tip of the catheter and subsequent dislodgement, nerve and vessel dissection or perforation) • Pain • Hemorrhage • Infection necessitating medical intervention • Foreign body reactions necessitating medical intervention • Emboli • Ischemia • Vasospasm • Tissue necrosis • Undesirable clot formation of the vasculature • Claudication • Recanalization • Death • Temporary neurological deficit. CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. RENEGADE® STC-18 MICROCATHETER Prior to use, please see the complete Directions for Use for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events and Operator‘s Instructions. INDICATIONS FOR USE/INTENDED USE: The Renegade STC-18 Microcatheter is intended for peripheral vascular use. The microcatheter can be coaxially tracked over a steerable guidewire in order to access distal, tortuous vasculature. Once the subselective region has been accessed, the microcatheter can be used for the controlled and selective infusion of diagnostic, embolic or therapeutic materials into vessels. Diagnostic, embolic, therapeutic agents to be used in accordance with specifications outlined by the manufacturer. CONTRAINDICATIONS: None known. ADVERSE EVENTS: The adverse events include, but are not limited to: • Vessel trauma • Embolism • Hemorrhage/Hematoma • Vasospasm • Infection • Air embolism • Allergic reaction. PRECAUTIONS: This device should be used only by physicians thoroughly trained in percutaneous, intravascular techniques and procedures. CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. Boston Scientific Corporation One Boston Scientific Place Natick, MA 01760-1537 www.bostonscientific.com To order product or for more information, contact customer service at 1.888.272.1001. © 2010 Boston Scientific Corporation or its affiliates. All rights reserved. 90527611 FEB10
© Copyright 2026 Paperzz