PATG-3628 - Schier Products

PATG-3628
Wet Inlet Grease Interceptor Technical Data
Submittal | Specifications | Installation | Maintenance
C
L TO GRADE
"
35½"
(90.2 cm)
41¼"
(104.8 cm)
SPECIFY
DIMENSION
TO GRADE
6¼"
(15.9 cm)
10½"
(26.7 cm)
STD.
32½"
(82.5 cm)
26¼"
(66.7 cm)
22"
(55.8 cm)
SUBMITTAL
STANDARD: 4" plain end inlet/outlet | Capacities - Liquid: 110 gal.; Grease: 350 lbs. (48.4 gal.);
Light Duty, bolted, gas/water tight polyethylene covers. (450 lbs. when direct buried)
OPTIONS:
APPROVAL:
Custom riser to finished floor or grade *All custom riser sales
min. 4" to a max of 36". Please supply are final, no returns.
dimension from C.L. of inlet grade.
(See box above)
3" Plain End Inlet/Outlet
3" Male Pipe Thread Connections
4" Male Pipe Thread Connections
1/4" thick steel treadplate cover
Recessed for tile steel cover
MODEL NUMBER:
Signature:
Date:
Company:
Specifying Engineer:
Engineering Firm:
PATG-3628
PART #: 4150-000-XX
DESCRIPTION: Wet Inlet Grease Interceptor
100 GPM - 110 gallon capacity
DWG BY: C. O'Boyle
DATE: 12/14/2015
9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | www.schierproducts.com
REV: 1
1/11/2017
ECO:
© Copyright 2017 Schier, All Rights Reserved
page 1 of 3
SPECIFICATIONS
6-7/8"
OUTLET "A"
NOTES
1.
2.
3.
4.
4" plain end inlet/outlet
Unit weight - w/standard covers: 162 lbs.
Maximum operating temperature: 190º F continuous
Capacities - Liquid: 110 gal.; Grease: 350 lbs. (48.4
gal.)
5. For replacement only.
6. Do not specify for new construction.
7. Built-in Flow control.
8. For gravity drainage applications only.
9. Do not use for pressure applications.
10. Kitchen-duty polyethylene cover with 1/4" stainless
steel bolts (Load Capacity 500 lbs.)
11. Vent not required unless per local code.
12. Engineered inlet and outlet diffusers are removable
to inspect/clean piping.
13. Integral air relief / Anti-siphon / Sampling access.
OUTLET "B"
35-1/2"
A
A
OUTLET "C"
TOP VIEW
DIFFUSION FLOW TECHNOLOGY
The inlet diffuser splits influent into three paths, creating
laminar flow and utilizing the entire liquid volume of the tank
for efficient grease separation. The calibrated openings
greatly reduce effluent turbulence. The effluent enters the
main chamber without disturbing the existing grease or
sediment layers.
The integral air relief / anti-siphon in the top of the outlet
diffuser allows pressure stabilization within the unit during
operation. The bottom of the outlet diffuser allows only
effluent which is free of grease to exit the tank. It can easily be
attached to any of the three outlets provided to ease jobsite
piping layouts.
41-1/4"
CL OF
INLET
AIR RELIEF/ANTI-SIPHON
ON OUTLET DIFFUSER
STATIC WATER LINE
6-1/4"
10-1/2"
CL OF
OUTLET
32-1/2"
ENGINEER SPECIFICATION GUIDE
22"
Schier Trapper™ grease interceptor model # PATG-3628
shall be lifetime guaranteed and made in USA of seamless,
rotationally-molded polyethylene with minimum 3/8" uniform
wall thickness. Interceptor shall be furnished for above or
below grade installation. Interceptor shall be built in accordance to ASME A112.14.3 (type C), with built-in flow control,
built-in test caps and three outlet options. Interceptor flow
rate shall be 100 GPM. Interceptor grease capacity shall be
350 lbs. Cover shall provide water/gas-tight seal and have
minimum 500 lbs. load capacity.
26-1/4"
ENGINEERED INLET AND OUTLET
DIFFUSER (SEE DESCRIPTION)
SECTION A-A
OUTLET END VIEW
MODEL NUMBER:
PATG-3628
PART #: 4150-000-XX
DESCRIPTION: Wet Inlet Grease Interceptor
100 GPM - 110 gallon capacity
DWG BY: C. O'Boyle
DATE: 12/14/2015
9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | www.schierproducts.com
REV: 1
1/11/2017
ECO:
© Copyright 2017 Schier, All Rights Reserved
page 2 of 3
INSTALLATION
Vent
WARNING! DO NOT AIR TEST UNIT!
Doing so may result in property damage, personal injury or death.
LEAK/SEAL TESTING
Cap/plug all base unit plumbing connections and remove cover. Fill with
water to just above the highest connection. Inspect unit and connections
for leaks. Check water level at specific time intervals per local code.
GENERAL INSTALLATION INSTRUCTIONS
Schier grease interceptors are rated and manufactured with an internal
flow control system. They do not require an external flow control system
or air intake vent. Flow control plate may be removed when interceptor is
is installed less than 13 feet below the fixtures being served. Schier grease
interceptors are not to be installed in any other manner except as shown.
Consult local codes for separate trapping requirements, cleanout
locations and additional installation instructions.
1. Set unit on level solid surface as close as possible to fixtures being served.
2. Connect outlet diffuser to the desired outlet (A,B,C). Unit is shipped with
the outlet diffuser in location B and sealing caps on locations A and C.
3. Connect inlet and outlet drainage lines to unit. Mechanically couple pipes
to unit. Do not solvent weld. Roll down inlet line using (2) 45º elbows
immediately preceding the unit to ensure inlet pipe is clear of water.
4. To conduct a pressure test on the pipes, remove diffusers and fasten
green caps to the inlet and outlet connections. Do not pressure test unit.
Hand tighten inlet/outlet diffusers and caps back to chosen positions.
5. Run sinks to fill unit with water and replace cover.
BELOW GRADE INSTALLATION INSTRUCTIONS
If unit is buried, backfill with sand or pea gravel. Pour concrete and install
finished floor. Note: maximum extension dimension is 36"
INDIRECT CONNECTIONS
Flow
control
plate
Roll Down
FLOW CONTROL
PLATE DETAIL
SIDE VIEW DETAIL
Vent
Rubber cap with 1/2" dia.
orifice (by others)
Floor Drain/
Floor Sink
10'
Recommended
INSTALLATION FOLLOWING INDIRECT CONNECTION
Installing a rubber cap with a 1/2" diameter orifice at the point of
discharge to the floor sink may be necessary to prevent overflow when the
flow control plate is installed.
MAINTENANCE
1. Remove cover.
2. Remove all contents of grease interceptor including grease, sediment
and wastewater.
3. To access inlet and outlet lines for cleaning, remove the diffusers. Clean
diffusers thoroughly before replacing to original positions.
4. Hand tighten inlet and outlet diffusers back to original positions.
5. Run sinks to fill unit with water and replace cover. Dispose of grease per
local code.
PUMPING FREQUENCY
Frequency depends on the capacity of the interceptor and the amount of
grease and sediment in the wastewater. After initial installation, it is
recommended that the unit is pumped every 3 to 4 weeks. Monitor each
pumping to establish an adequate maintenance schedule based off actual
kitchen variances.
TROUBLESHOOTING TIPS
In the case of a clog, inlet and outlet diffusers may be removed for line
cleaning. Slower than usual sink drainage may indicate the need to
pump/clean grease interceptor.
Always take proper care to ensure a safe and healthy environment while
cleaning interceptor. For best cleaning and maintenance service, call your
local sewer and drain contractor.
MODEL NUMBER:
PATG-3628
PART #: 4150-000-XX
DESCRIPTION: Wet Inlet Grease Interceptor
100 GPM - 110 gallon capacity
DWG BY: C. O'Boyle
DATE: 12/14/2015
9500 Woodend Road | Edwardsville, KS 66111 | Tel: 913-951-3300 | Fax: 913-951-3399 | www.schierproducts.com
REV: 1
1/11/2017
ECO:
© Copyright 2017 Schier, All Rights Reserved
page 3 of 3