Office of FIRE PREVENTION A-9.7.1.2. (2) Bedroom Window Opening Areas and Dimensions Although the minimum opening dimensions required for height and width are 15 inches, a window opening that is 15 inches by 15 inches would not comply with the minimum area requirements. (See Figure A-9.7.1.2. (2)) Figure A-9.7.1.2.(2) Window opening area and dimensions 15 inches 15 inches 15 inches Opening area 1.55 f ² Opening area 3.76 f ² 36 inches (a) 23 9/32 inches 23 9/32 inches Opening area 3.76 f ² (c) (b) (a) conforms to opening height and width requirements; does not conform to opening area requirements. (b) and (c) conform to height, width and opening area requirements Office of FIRE PREVENTION Refer to #2, 16.2.2. Bedroom Windows of Inspection letter A-9.7.1.2. (2) Bedroom Window Opening Areas and Dimensions Although the minimum opening dimensions required for height and width are 380 mm, a window opening that is 380 mm by 380 mm would not comply with the minimum area requirements. (See Figure A-9.7.1.2. (2)) Figure A-9.7.1.2.(2) Window opening area and dimensions 380 mm 380 mm Opening area 0.144 m2 380 mm 920 mm Opening area 0.35 m2 (a) 592 mm 592 mm Opening area 0.35 m2 (c) (b) (a) conforms to opening height and width requirements; does not conform to opening area requirements. (b) and (c) conform to height, width and opening area requirements