Force Sensor KD24S Nominal force ranges ±2N, ±10N, ±20N, ±50N, ±100N The force sensor KD24S is the smallest s-shaped force sensor. It is excellently suited for testing tasks in quality assurance as well as in material testing. Inward and outward force transmission are arranged centrically. Under loading the force transmission brackets are moved parallel. Like the KD40s the force sensor KD24S is constructed as a multi-range sensor. The accuracy of 0.1 % is already reached at an output of 0.5 mV/V. Sensors from 2 to 20N can be operated with 4 times and sensors from 50 to 100N with two times their nominal force range. It is recommended to fix the sensor cable side (bottom side on picture) on the non-moving side of force transmission. Dimensions Bestech Australia 1 U14/44 Garden Blvd, Dingley VIC 3172 Tel: 03 9540 5100 Fax: 03 9551 5541 [email protected] www.bestech.com.au Force Sensor KD24S Nominal force ranges ±2N (8N), ±10N (40N), ±20N (80N), ±50N (200N), ±100N (200N) Technical Data Force sensor Construction Length width x height Force transmission Fastening Material Accuracy class Nominal force FN Nominal deflection Operating force Breaking force Nominal temperature range Operating temperature range Storage temperature range Nominal output (SN) Zero signal tolerance Max. supply voltage Input resistance Output resistance Insulation resistance Connection, 4-conductor open Linearity error Reversal error Temperature coeff. of the zero signal Temperature coeff. of the nominal output Zero point return error (30 min) Creep error (30 min) Tension / compression Double bending beam 24mm x 26mm x10mm M5 mm M5 mm aluminum 0.1 2 0.05 8 20 10 0.05 40 100 20 0.05 80 200 50 0.06 100 500 +10…+60 - 20…+80 - 40…+80 100 0.1 200 1000 N mm N N °C °C °C 0.5 0.1 % 1) 10 10 390 0 4 350 1.5 >5*109 2 mV/V % FN V Ohm Ohm Ohm m % SN % SN % FN /K ≤ 0.1 ≤ 0.1 ≤ ±0.02 ≤ ±0.01 % SN /K ≤ 0.1 ≤ 0.1 % SN % SN 1) The nominal output might differ from 0.5 mV/V. In that case the exact output will be given in a proof protocol. Pin Configuration +US - US +UD - UD positive bridge supply negative bridge supply positive bridge output negative bridge output Bestech Australia 2 U14/44 Garden Blvd, Dingley VIC 3172 red black green white Tel: 03 9540 5100 Fax: 03 9551 5541 [email protected] www.bestech.com.au Force Sensor KD40S Nominal force ranges ±2N, ±10N, ±20N, ±50N, ±100N , ±500N, ±1000N, ±2000N The force sensor KD40S is very well suited for testing tasks in quality assurance as well as in materials testing due to its compact construction. Inward and outward force transmission are arranged centrically. The force sensors KD40S up to 100N are constructed as multi-range sensors. The accuracy of 0.1 % is already reached at an rated output of 0.5 mV/V. This means that the zero-point stability is 4 times higher than in a sensor with the nominal output of 2 mV/V. The force sensor KD40S can be used up to an output signal of 2 mV/V or four times the specified nominal force. The force sensor KD40S (up to 100 N) should be installed in such way that the outgoing cables are assigned to the immobile side of the measuring construction. Thus forces from the connecting cable do not have an influence on measurement results. From 500N upwards the force sensors KD40s have a nominal rated output of 1.0mV/V. They can safely be overloaded up to 1.5x their nominal force. The cable output can be found in the middle of the two force transmission beams. For force transfer there exists one thread M5 (up to 100N) and M6 (from 500N) in the top and bottom side of the force sensor. Additionally there is a thread M6 (from 500N) that can be used as anti-twist protection. The force sensor from a nominal force of 1000N has a height of 34 mm. Bestech Australia 1 1 U14/44 Garden Blvd, Dingley VIC 3172 Tel: 03 9540 5100 Fax: 03 9551 5541 [email protected] www.bestech.com.au Dimensions Pin Configuration +US - US +UD - UD positive bridge supply negative bridge supply positive bridge output negative bridge output Bestech Australia 2 2 U14/44 Garden Blvd, Dingley VIC 3172 Version 1 red black green white Version 2 brown white green yellow Tel: 03 9540 5100 Fax: 03 9551 5541 [email protected] www.bestech.com.au Force Sensor KD40S Nominal force ranges ±2N, ±5N, ±10N, ±20N, ±50N, ±100N Technical Data 2N...100N Force sensor Construction Length width x height Force transmission Fastening Material Accuracy classes tension / compression double beam 403010 M5 M5 aluminum 0.1 mm mm mm mm Nominal force FN Nominal displacement Operating force Breaking force ±2 ... ±2000 < 0.05 400 > 300 N mm %FN %FN Nominal temperature range Operating temperature range Storage temperature range +10…+60 -20…+80 -40…+80 °C °C °C Nominal output (SN) Zero signal tolerance Max. supply voltage Input resistance Output resistance Insulation resistance Connection, 4 conductor open 0.5 0.1 % 10 10 400 20 350 2 > 5 109 2 mV/V %FN V Ohm Ohm Ohm m Linearity error Backlash width Temp. coeff. of the zero signal Temp. coeff. of the nominal output Zero point return error (30 min) Creep error (30 min) << 0.1 << 0.1 0.02 0.01 << 0.1 << 0.1 % SN % SN %FN/K % SN/K % SN % SN Bestech Australia 3 3 U14/44 Garden Blvd, Dingley VIC 3172 Tel: 03 9540 5100 Fax: 03 9551 5541 mm [email protected] www.bestech.com.au Force Sensor KD40S Nominal force ranges ±500N, ±1000N, ±2000N Technical Data 500N...2000N Force sensor Construction Length width x height Force transmission Fastening Material Accuracy classes tension / compression shear beam 40 34 10 M6 M6 aluminum 0,1 mm mm mm mm mm Nominal force FN Nominal displacement Operating force Breaking force 500 ... 2000 < 0.5 150 > 300 N mm %FN %FN Nominal temperature range Operating temperature range Storage temperature range +10…+60 - 20…+80 - 40…+80 °C °C °C Nominal output (SN) Zero signal tolerance Max. supply voltage Input resistance Output resistance Insulation resistance Connection, 4 conductor open 1.0 ± 0.1% 10 10 1200 50 1000 5 > 5 109 2 mV/V % FN V Ohm Ohm Ohm m Linearity error Backlash width Temp. coeff. of the zero signal Temp. coeff. of the nominal output Zero point return error (30 min) Creep error (30 min) • 0.1 • 0.1 • 0.02 • 0.01 • 0.1 • 0.1 % SN % SN % FN/K % SN/K % SN % SN Bestech Australia 4 4 U14/44 Garden Blvd, Dingley VIC 3172 Tel: 03 9540 5100 Fax: 03 9551 5541 [email protected] www.bestech.com.au LOAD CELLS KCE-NA Center-hole type Compression Load Cell Bestech Australia 500kN~2MN LOAD CE LLS KCM-NA Center-hole type Compression Load Cell Bestech Australia 50kN~5MN LOAD CELLS KCC-NA Center-hole type Compression Load Cell 200kN ~ 1MN ./ Bestech Australia LOAD CELLS KCC-NA Center-hole type Compression Load Cell 200kN ~ 1MN ./ Bestech Australia LOAD CE LLS Bestech Australia
© Copyright 2026 Paperzz