SPECIAL CABLES · TEMPERATURE MEASUREMENT · HARNESSING CABLES FOR RAILWAY TECHNOLOGY CONTENT OVERVIEW Who we are ......................................................................................................... 3 Fire protection requirements ......................................................................................................... 4 VDE test results ......................................................................................................... 5 Selection index for cables for railway technology ....................................................................................... 6 CABLES FOR RAILWAY TECHNOLOGY n A A 146 FRNC Wiring cable 300/500 V, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 n A A 156 FRNC Wiring cable 450/750 V, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 n A R 600 FRNC S Rail Control with numbered cores, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . 8 n A R 638 FRNC S Rail Control with numbered cores and overall copper screen, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 n A R 605 FRNC S Rail Data, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11 n A R 615 FRNC S Rail Data with overall copper screen, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . 12-13 n A R 645 FRNC TP S Rail Data, paired with overall copper screen, tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 15 n CAT 5e R halogen-free CAT 5e Industrial Ethernet cable n CAT 6A R halogen-free CAT 6A Gigabit Ethernet cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 n CAT 7A R halogen-free CAT 7A Gigabit Ethernet cable ..................................................... ...................................................... 15 n A A 280 FRNC X Wiring cable 300/500 V, cross linked type tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . 16 n A A 280 FRNC X Control cable with numbered cores, cross linked type tested acc. to DIN EN 45545-2 n A A 285 FRNC X Control cable with numbered cores and overall copper screen, cross linked type tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 n A A 280 FRNC X (FR) fire resistant control cable, cross linked type tested acc. to DIN EN 45545-2, EN 50200 and IEC 60331-21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 n R 107 Besilen® insulated copper rope tested acc. to DIN EN 45545-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 n B 107 Besilen® insulated strands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 n A A 224 FRNC C1 Control cable with numbered cores acc. to NF C32-070 C1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-22 n A CC 625 FRNC M Control cable with numbered cores acc. to UL and CSA n A CC 625 S FRNC M Control cable with numbered cores and overall copper screen acc. to UL and CSA . . . . . . . . . . . 24 n A A 810 FRNC Motor connection cable with numbered cores 0,6/1 kV n A A 812 C FRNC Motor connection cable with numbered cores, inner sheath and overall copper screen 0,6/1 kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 n Hybrid and Special cables ....... ......................................... ........................................... ......................................................................................................... 16 23 25 26 27 n CAN-Bus cables halogen-free combined cable with overall copper screen n Coupling cable torsion able connecting cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 n A A 883 Ö twisting and torsion connection cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 n Our cables at a glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 n Our temperature measurement at a glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 ......................................... n Harnessed cables ......................................................................................................... 31 n B helix cables ......................................................................................................... 31 q In case that you don’t find a suitable cable for your special application, we are always prepared to design a cable according to your individual construction requirements. 2 www.sab-cable.com WHO WE ARE AN OVERVIEW M ore than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff members. Our strength is not only the production of standard products but also the development and manufacturing of special products acc. to customers’ specifications. Every year we manufacture more than 1500 special products on our customers’ request. Every single product is a challenge for our technical team. We at B BRÖCKSKES see ourselves as manufacturer and service provider - in the sense of real partnership and customer oriented work. The quality of our products is known in more than 40 countries worldwide. Our customers have tested our products intensively and confirm that they have a longer service life than others. In all product ranges we are certified acc. to ISO 9001:2008. Besides we established an environmental management system for our company acc. to ISO 14001:2004, an occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007 as well as an energy management system acc. to DIN EN ISO 50001:2011. And our future slogan is: WE GO FORWARD! FOUNDED: 1947 by Peter Bröckskes sen. an independent, medium-sized company. CEO: Peter Bröckskes and Sabine Bröckskes-Wetten PLANT/LOCATION: In Viersen (Lower Rhine) 110.000 m2 company site. Own manufacturing from copper conductor to outer sheath. EMPLOYEES/WORKERS: Approx. 420 at the plant in Viersen, 500 worldwide YEARLY SALES: Approx. 95 Mio. € worldwide PRODUCTS: Special Cables Temperature Measurement Cable Harnessing CERTIFICATES AND APPROVALS: Quality management system acc. to ISO 9001:2008 for every manufacturing field k VDE proofed burnchamber and laboratory within the company. Environmental management system acc. to ISO 14001:2004 Occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007 Energy management system acc. to DIN EN ISO 50001:2011 www.sab-cable.com 3 FIRE PROTECTION REQUIREMENTS DIN EN 45545-2 Extract from DIN EN 45545-2 table 5 requirement set R15 (EL1A) for the respective hazard classes Short name of requireme nt set (used for) R15 (EL1A) Test methode reference Parameter Unit Maximum or Minimum HL1 burned part ≤ 540 and unburned part > 50 HL2 burned part ≤ 540 and unburned part > 50 HL3 T09.01 EN 60332-1-2 Unbured length mm Minimum burned part ≤ 540 and unburned part > 50 T09.02 EN 60332-3-24 (for d ≥ 12 mm) m Maximum 2,5 2,5 2,5 T09.03 EN 50305 (for 6 mm < d < 12 mm) m Maximum 2,5 2,5 2,5 T09.04 EN 50305 (for d ≤ 6 mm) m Maximum 1,5 1,5 1,5 T13 EN 61034-2 Transmission % Minimum 25 50 70 T15 EN 50305 ITC dimensionless Maximum 10 10 6 Hazard level classification (HL) Extract from DIN EN 45545-2 table 5 requirement set R15 (EL1A) for the respective hazard classes Operation category 4 Design category N: Standard vehicles A: D: Vehicles forming part Double decked of an automatic train vehicles having no emergency trained staff on board S: Sleeping and couchette vehicles 1 HL1 HL1 HL1 HL2 2 HL2 HL2 HL2 HL2 3 HL2 HL2 HL2 HL3 4 HL3 HL3 HL3 HL3 www.sab-cable.com VDE TEST RESULTS www.sab-cable.com 5 SELECTION INDEX FOR CABLES Voltage Temperature range fixed laying* Fire performance Standards Halogen-free from short time use to 6 www.sab-cable.com l l l l l l l l l l l l l R 107 l A A 285 FRNC X l A A 280 FRNC X A R 645 FRNC TP l CAT 7A R A R 615 FRNC l CAT 6A R A R 605 FRNC l A R 638 FRNC A A 156 FRNC l A R 600 FRNC A A 146 FRNC Single conductor Multi-core cable screened Wiring cable Data cable Control cable Ethernet cable cross linked type tested acc. to DIN EN 45545-2 acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. No flame propagation acc. to DIN EN 60332-3-24 No flame propagation acc. to DIN EN 60332-3-25 resp. DIN EN 50305 section 9.1.1 No flame propagationg acc. to DIN EN 50305 section 9.1.2 Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2 acc. to ASTM E 162-09 Flame retardant ISO 6722 (UN/ECE R118) Toxicity acc. to DIN EN 50305 Smoke density acc. to DIN EN 61034 Smoke density acc. to ASTM E 662-09 Absence of harmful substances acc. to RoHS directive of the European Union + 250 °C + 180 °C + 125 °C + 90 °C + 70 °C – 40 °C – 50 °C Nominal voltage Uo/U 300/500 V Nominal voltage Uo/U 450/750 V Nominal voltage Uo/U 1,8/3,0 kV Peak operating voltage: < 0,25 mm2 = max. 350 V ≥ 0,25 mm2 = max. 500 V Peak operating voltage: max. 90 V CAT 5e R Applications Cable type FOR RAILWAY TECHNOLOGY l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l *The temperature range for flexible application is mentioned on the particular catalogue page CABLES FOR RAILWAY TECHNOLOGY SA 146 FRNC SA 156 FRNC 5-2 E N 4554 Wiring cable 300/500V t acc. to tardan Flame re Wiring cable 450/750 V 3 U N / ECE R118 s B R Ö CK S K E S · D - V I E R S E N · S A 1 4 6 F R N C 3 0 0 / 5 0 0 V 0 , 5 m m 2 C Marking for S A 146 FRNC 61460150: s BRÖCKSKES · D-VIERSEN · S A 146 FRNC 300/500V 0,5 mm2 C Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: x A 146 FRNC: Uo/U 300/500 V x A 156 FRNC: Uo/U 450/750 V Insulation: special A Testing voltage: x A 146 FRNC: 2000 V x A 156 FRNC: 2500 V Min. bending radius: For one single bend: 7.5 x d 5xd Temperature range fixed laying: flexible application: -50/+90 °C -40/+90 °C Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Toxicity: acc. to DIN EN 50305 Outstanding features: ® halogen-free ® no flame propagation ® flame retardant and self-extinguishing ® very good stripping ® flexible ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 x A 146 FRNC item no. 6146 .. 50* 6146 .. 75* 6146 .. 80* largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 0,50 0,75 1,00 0,21 0,21 0,21 2,1 2,4 2,5 4,8 7,2 9,6 9 12 14 Other dimensions and colours are possible on request. * Colour code for single conductors: 06 = green 02 = blue 07 = violet acc. to DIN EN 61034 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union x A 156 FRNC nominal cross-section mm2 01 = black Smoke density: 03 = brown 08 = white 04 = grey 16 = gentian blue 05 = yellow 27 = green-yellow item no. 6156 .. 82* 6156 .. 84* 6156 .. 86* 6156 .. 87* 6156 .. 88* 6156 .. 89* 6156 .. 90* 6156 .. 91* 6156 .. 92* 6156 .. 93* 6156 .. 94* 6156 .. 95* 6156 .. 96* 6156 .. 97* 6156 .. 98* 6156 .. 99* nominal cross-section mm2 1,50 2,50 4,00 6,00 10,00 16,00 25,00 35,00 50,00 70,00 95,00 120,00 150,00 185,00 240,00 300,00 largest single wire ø mm 0,26 0,26 0,31 0,31 0,41 0,41 0,41 0,41 0,41 0,41 0,51 0,51 0,51 0,51 0,51 0,51 outer-ø ± 5% mm 3,0 3,6 4,2 4,7 6,3 8,0 9,9 11,1 12,6 14,8 18,2 19,7 21,8 23,2 26,9 30,0 copper figure kg/km 14,4 24,0 38,4 57,6 96,0 153,6 240,0 336,0 480,0 672,0 912,0 1152,0 1440,0 1776,0 2304,0 2880,0 cable weight ≈ kg/km 20 32 48 67 117 181 292 394 563 751 1034 1241 1544 1866 2507 3125 Other dimensions and colours are possible on request. www.sab-cable.com 7 CABLES FOR RAILWAY TECHNOLOGY 5-2 E N 4554 SR 600 FRNC S Rail Control with numbered cores 3 s BRÖCKSKES · D-VIERSEN · SR 600 FRNC 12 x 1,5 mm2 C Marking for X R 600 FRNC 66001215: S BRÖCKSKES · D-VIERSEN · X R 600 FRNC 12 x 1,5 mm2 C Conductor: Technical data: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: Uo/U 300/500 V Insulation: special A Testing voltage U: 3000 V Colour code: black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Min. bending radius fixed laying: flexible application: 4xd 6xd Stranding: in layers Sheath material: special A Temperature range fixed laying: flexible application: -40/+90 °C -30/+90 °C Sheath colour: grey (RAL 7000) Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Toxicity: acc. to DIN EN 50305 Outstanding features: item no. 66000205 66000305 66000405 66000505 66000705 66001005 66001205 66001805 66002505 66003205 66004205 66006105 66000207 66000307 66000407 66000507 66000707 66001007 66001207 66001807 66002507 66003207 66004207 66006107 66000210 66000310 66000410 66000510 66000710 66001010 66001210 66001810 66002510 66003210 66004210 66006110 66000215 66000315 8 ® halogen-free ® no flame propagation ® flame retardant and self-extinguishing ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 no. of cores x cross section n x mm2 2 x 0,50 3 x 0,50 4 x 0,50 5 x 0,50 7 x 0,50 10 x 0,50 12 x 0,50 18 x 0,50 25 x 0,50 32 x 0,50 42 x 0,50 61 x 0,50 2 x 0,75 3 x 0,75 4 x 0,75 5 x 0,75 7 x 0,75 10 x 0,75 12 x 0,75 18 x 0,75 25 x 0,75 32 x 0,75 42 x 0,75 61 x 0,75 2 x 1,00 3 x 1,00 4 x 1,00 5 x 1,00 7 x 1,00 10 x 1,00 12 x 1,00 18 x 1,00 25 x 1,00 32 x 1,00 42 x 1,00 61 x 1,00 2 x 1,50 3 x 1,50 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,26 0,26 4,8 5,1 5,5 6,2 6,7 8,6 9,1 10,7 12,9 14,0 15,7 18,5 5,4 5,7 6,4 7,0 7,8 10,0 10,5 12,4 15,1 16,4 18,4 21,6 5,6 6,1 6,6 7,5 8,1 10,6 10,9 12,9 15,7 17,1 19,4 22,7 6,4 6,8 9,6 14,4 19,2 24,0 33,6 48,0 57,6 86,4 120,0 153,6 201,6 292,8 14,4 21,6 28,8 36,0 50,4 72,0 86,4 129,6 180,0 230,4 302,4 439,2 19,2 28,8 38,4 48,0 67,2 96,0 115,2 172,8 240,0 307,2 403,2 585,6 28,8 43,2 33 38 46 57 69 96 110 169 221 287 365 510 44 51 63 77 96 144 163 230 316 388 515 721 50 62 76 94 117 172 196 280 381 486 616 873 69 81 www.sab-cable.com Smoke density: acc. to DIN EN 61034 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union item no. 66000415 66000515 66000715 66001015 66001215 66001815 66002515 66003215 66004215 66006115 66000225 66000325 66000425 66000525 66000725 66001025 66001225 66001825 66002525 66000340 66000440 66000540 66000740 66000360 66000460 66000560 66000760 66000461 66000561 66000761 66000462 66000562 66000762 66000463 66000563 66000464 66000564 no. of cores x cross section n x mm2 4 x 1,50 5 x 1,50 7 x 1,50 10 x 1,50 12 x 1,50 18 x 1,50 25 x 1,50 32 x 1,50 42 x 1,50 61 x 1,50 2 x 2,50 3 x 2,50 4 x 2,50 5 x 2,50 7 x 2,50 10 x 2,50 12 x 2,50 18 x 2,50 25 x 2,50 3 x 4,00 4 x 4,00 5 x 4,00 7 x 4,00 3 x 6,00 4 x 6,00 5 x 6,00 7 x 6,00 4 x 10,0 5 x 10,0 7 x 10,0 4 x 16,0 5 x 16,0 7 x 16,0 4 x 25,0 5 x 25,0 4 x 35,0 5 x 35,0 largest single wire ø mm outer-ø ± 5% mm 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,31 0,31 0,31 0,31 0,31 0,31 0,31 0,31 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 7,6 8,3 9,2 12,0 12,4 14,8 18,0 19,5 22,0 25,8 7,8 8,9 9,2 10,1 11,2 14,8 15,3 18,2 22,3 9,7 10,8 12,1 13,4 11,4 12,7 14,2 15,7 16,7 18,6 20,7 20,6 23,0 25,5 24,9 28,1 28,8 32,5 copper figure kg/km 57,6 72,0 100,8 144,0 172,8 259,2 360,0 460,8 604,8 878,4 48,0 72,0 96,0 120,0 168,0 240,0 288,0 432,0 600,0 115,2 153,6 192,0 268,8 172,8 230,4 288,0 403,2 384,0 480,0 672,0 614,4 768,0 1075,2 960,0 1200,0 1344,0 1680,0 cable weight ≈ kg/km 99 124 170 229 263 289 537 661 867 1217 105 127 155 199 252 362 416 615 837 185 234 290 375 270 336 415 545 579 740 960 887 1105 1445 1388 1750 1927 2413 Other dimensions and colours are possible on request. Tested at reference types. Construction: CABLES FOR RAILWAY TECHNOLOGY 5-2 E N 4554 SR 638 FRNC S Rail Control with numbered cores and overall copper screen 3 BRÖCKSKES · D-VIERSEN · X R 638 FRNC 5 x 1,5 Marking for X R 638 FRNC 66380515: S BRÖCKSKES · D-VIERSEN · X R 638 FRNC 5 x 1,5 mm2 C Conductor: Technical data: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: Uo/U 300/500 V Testing voltage U: 3000 V core/screen 2000 V Insulation: special A Colour code: black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Min. bending radius fixed laying: flexible application: 5xd 10 x d Stranding: in layers Wrapping: foil Screen: tinned copper braiding Temperature range fixed laying: flexible application: -40/+90 °C -30/+90 °C Sheath material: special A Sheath colour: grey (RAL 7000) Outstanding features: Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Toxicity: acc. to DIN EN 50305 ® halogen-free ® good EMC characteristics* ® no flame propagation ® flame retardant and self-extinguishing Smoke density: acc. to DIN EN 61034 ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union Tested at reference types. Construction: * Copper braiding should be connected circularly to optimize * the EMC characteristics item no. 66380205 66380305 66380405 66380505 66380705 66381205 66381805 66382505 66380207 66380307 66380407 66380507 66380707 66381207 66381807 66382507 66380210 66380310 66380410 66380510 66380710 66381210 66381810 66382510 no. of cores x cross section n x mm2 2 x 0,50 3 x 0,50 4 x 0,50 5 x 0,50 7 x 0,50 12 x 0,50 18 x 0,50 25 x 0,50 2 x 0,75 3 x 0,75 4 x 0,75 5 x 0,75 7 x 0,75 12 x 0,75 18 x 0,75 25 x 0,75 2 x 1,00 3 x 1,00 4 x 1,00 5 x 1,00 7 x 1,00 12 x 1,00 18 x 1,00 25 x 1,00 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 5,3 5,6 6,2 6,7 7,2 9,6 11,4 13,8 6,1 6,4 6,9 7,7 8,3 11,2 13,3 16,2 6,3 6,6 7,1 8,0 8,6 11,8 13,8 16,8 25,5 30,7 48,0 55,9 71,1 108,1 143,5 189,7 31,1 50,6 61,1 73,7 90,9 142,4 197,9 284,6 48,0 58,2 75,7 86,1 108,2 172,1 242,1 346,5 38 45 61 70 81 150 206 272 50 61 73 96 121 193 280 395 56 68 94 110 138 226 315 454 item no. 66380215 66380315 66380415 66380515 66380715 66381215 66381815 66382515 66380225 66380325 66380425 66380525 66380725 66381225 66381825 66382525 66380440 66380540 66380460 66380560 66380461 66380462 no. of cores x cross section n x mm2 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 2 x 1,50 3 x 1,50 4 x 1,50 5 x 1,50 7 x 1,50 12 x 1,50 18 x 1,50 25 x 1,50 2 x 2,50 3 x 2,50 4 x 2,50 5 x 2,50 7 x 2,50 12 x 2,50 18 x 2,50 25 x 2,50 4 x 4,00 5 x 4,00 4 x 6,00 5 x 6,00 4 x 10,00 4 x 16,00 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,31 0,31 0,31 0,31 0,41 0,41 6,9 7,2 8,1 9,0 9,7 13,9 15,7 19,1 8,3 9,0 9,7 11,0 12,1 16,4 19,3 23,4 11,5 12,8 13,6 15,1 17,8 21,9 60,7 80,5 95,6 113,2 151,2 240,8 362,3 492,1 86,3 113,0 146,2 175,0 225,1 392,0 564,1 770,1 210,7 260,0 298,4 358,7 517,1 756,0 63 90 110 135 178 300 454 613 100 128 163 215 276 466 666 931 250 309 353 420 616 917 Other dimensions and colours are possible on request. www.sab-cable.com 9 CABLES FOR RAILWAY TECHNOLOGY SR 605 FRNC 5-2 E N 4554 t acc. to tardan Flame re S Rail Data U N / ECE 3 CKSKES · D-VIERSEN · X R 605 FRNC 32 x 0,5 mm2 C Marking for X R 605 FRNC 66053250: S BRÖCKSKES · D-VIERSEN · X R 605 FRNC 32 x 0,5 mm2 C Technical data: bare copper strands with reference to IEC 60228, EN 6028, VDE 0295, class 5 Peak operating voltage: < 0.25 mm2 = max. 350 V ≥ 0.25 mm2 = max. 500 V Insulation: special A Testing voltage: Colour code: with reference to DIN 47100 < 0.25 mm2 = 800 V ≥ 0.25 mm2 = 1200 V Stranding: in layers Sheath material: special A Sheath colour: grey (RAL 7032) Min. bending radius fixed laying: flexible application: 5xd 10 x d Temperature range fixed laying: flexible application: -40/+90 °C -30/+90 °C Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Flame retardant acc. to ISO 6722 (UN/ECE R118) Toxicity: acc. to DIN EN 50305 Outstanding features: ® halogen-free ® no flame propagation ® flame retardant and self-extinguishing ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 ® item no. 66050214 66050314 66050414 66050514 66050714 66050814 66051214 66051414 66051614 66051814 66052114 66052414 66052714 66053014 66053214 66053614 66054014 66054414 66055014 66056114 66050225 66050325 66050425 66050525 66050725 66050825 66051225 66051425 66051625 10 flame retardant acc. to UN/ECE R118 no. of cores x cross section n x mm2 2 x 0,14 3 x 0,14 4 x 0,14 5 x 0,14 7 x 0,14 8 x 0,14 12 x 0,14 14 x 0,14 16 x 0,14 18 x 0,14 21 x 0,14 24 x 0,14 27 x 0,14 30 x 0,14 32 x 0,14 36 x 0,14 40 x 0,14 44 x 0,14 50 x 0,14 61 x 0,14 2 x 0,25 3 x 0,25 4 x 0,25 5 x 0,25 7 x 0,25 8 x 0,25 12 x 0,25 14 x 0,25 16 x 0,25 outer-ø ± 5% mm copper figure kg/km 3,1 3,3 3,5 3,8 4,1 5,0 5,3 5,5 6,0 6,3 6,9 7,3 7,7 7,9 8,2 8,5 9,1 9,5 10,3 10,9 3,4 3,6 3,9 4,2 4,6 5,2 6,1 6,4 6,7 2,7 4,0 5,4 6,7 9,4 10,8 16,1 18,8 21,5 24,2 28,2 32,3 36,3 40,3 43,0 48,4 53,8 59,1 67,2 82,0 4,8 7,2 9,6 12,0 16,8 19,2 28,8 33,6 38,4 www.sab-cable.com cable weight ≈ kg/km 13 15 18 21 25 32 38 42 51 56 65 70 80 86 92 101 112 119 142 165 17 20 24 29 35 43 57 64 72 Smoke density: acc. to DIN EN 61034 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union item no. 66051825 66052125 66052425 66052725 66053025 66053225 66053625 66054025 66054425 66055025 66056125 66050234 66050334 66050434 66050534 66050734 66050834 66051234 66051434 66051634 66051834 66052134 66052434 66052734 66053034 66053234 66053634 66054034 66054434 no. of cores x cross section n x mm2 18 x 0,25 21 x 0,25 24 x 0,25 27 x 0,25 30 x 0,25 32 x 0,25 36 x 0,25 40 x 0,25 44 x 0,25 50 x 0,25 61 x 0,25 2 x 0,34 3 x 0,34 4 x 0,34 5 x 0,34 7 x 0,34 8 x 0,34 12 x 0,34 14 x 0,34 16 x 0,34 18 x 0,34 21 x 0,34 24 x 0,34 27 x 0,34 30 x 0,34 32 x 0,34 36 x 0,34 40 x 0,34 44 x 0,34 outer-ø ± 5% mm 7,1 7,9 8,4 8,6 8,9 9,2 10,0 10,6 11,1 11,6 12,3 4,0 4,2 4,6 5,0 5,5 6,5 7,3 7,9 8,3 8,8 10,0 10,6 10,8 11,2 11,6 12,1 12,9 13,5 copper figure kg/km cable weight ≈ kg/km 43,2 80 50,4 96 57,6 104 64,8 114 72,0 125 76,8 132 86,4 156 96,0 173 105,6 184 120,0 204 146,4 241 6,5 24 9,8 27 13,1 33 16,3 40 22,8 49 26,1 63 39,2 80 45,7 94 52,2 106 58,8 117 68,5 146 78,3 157 88,1 172 97,9 187 104,4 199 117,5 220 130,6 244 143,6 261 Continued on next page Tested at reference types. Construction: Conductor: R118 CABLES FOR RAILWAY TECHNOLOGY SR 605 FRNC t acc. to tardan Flame re S Rail Data U N / ECE 3 item no. 66055034 66056134 66050250 66050350 66050450 66050550 66050750 66050850 66051250 66051450 66051650 66051850 66052150 66052450 66052750 66053050 66053250 66053650 66054450 66055050 66056150 66050275 66050375 66050475 66050575 66050775 66050875 5-2 E N 4554 R118 BRÖCKSKES · D-VIERSEN · X R 605 FRNC 32 x 0,5 mm Marking for X R 605 FRNC 66053250: S BRÖCKSKES · D-VIERSEN · X R 605 FRNC 32 x 0,5 mm2 C no. of cores x cross section n x mm2 50 x 0,34 61 x 0,34 2 x 0,50 3 x 0,50 4 x 0,50 5 x 0,50 7 x 0,50 8 x 0,50 12 x 0,50 14 x 0,50 16 x 0,50 18 x 0,50 21 x 0,50 24 x 0,50 27 x 0,50 30 x 0,50 32 x 0,50 36 x 0,50 44 x 0,50 50 x 0,50 61 x 0,50 2 x 0,75 3 x 0,75 4 x 0,75 5 x 0,75 7 x 0,75 8 x 0,75 outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 14,5 15,4 4,3 4,5 4,9 5,4 6,1 7,1 8,1 8,5 9,0 9,5 10,9 11,5 11,7 12,1 12,6 13,1 15,1 15,7 16,7 4,9 5,2 5,9 6,4 7,0 8,3 163,2 199,1 9,6 14,4 19,2 24,0 33,6 38,4 57,6 67,2 76,8 86,4 100,8 115,2 129,6 144,0 153,6 172,8 211,2 240,0 292,8 14,4 21,6 28,8 36,0 50,4 57,6 304 358 28 33 40 49 63 79 102 115 131 145 180 195 213 232 248 274 341 411 448 38 45 58 70 87 111 item no. 66051275 66051475 66051675 66051875 66052175 66052475 66052775 66053075 66053275 66053675 66054075 66054475 66055075 66056175 66050280 66050380 66050480 66050580 66050680 66050780 66050285 66050385 66050485 66050585 66050685 66050785 no. of cores x cross section n x mm2 12 x 0,75 14 x 0,75 16 x 0,75 18 x 0,75 21 x 0,75 24 x 0,75 27 x 0,75 30 x 0,75 32 x 0,75 36 x 0,75 40 x 0,75 44 x 0,75 50 x 0,75 61 x 0,75 2 x 1,00 3 x 1,00 4 x 1,00 5 x 1,00 6 x 1,00 7 x 1,00 2 x 1,50 3 x 1,50 4 x 1,50 5 x 1,50 6 x 1,50 7 x 1,50 outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 9,4 10,3 10,8 11,4 12,5 13,3 13,6 14,5 15,0 15,6 16,7 17,5 18,3 19,8 5,1 5,4 6,1 6,7 7,3 7,3 5,6 6,1 6,7 7,7 8,4 8,4 86,4 100,8 115,2 129,6 151,2 172,8 194,4 216,0 230,4 259,2 288,0 316,8 360,0 439,2 19,2 28,8 38,4 48,0 57,6 67,2 28,8 43,2 57,6 72,0 86,4 100,8 142 170 192 213 248 270 297 339 360 399 443 475 530 648 43 53 68 82 97 104 55 71 87 113 134 144 Other dimensions and colours are possible on request. www.sab-cable.com 11 CABLES FOR RAILWAY TECHNOLOGY SR 615 FRNC 5-2 E N 4554 t acc. to tardan Flame re SRail Data with overall copper screen U N / ECE R118 3 SKES · D-VIERSEN · X R 615 FRNC 7 x 0,5 mm2 C Marking for X R 615 FRNC 66150750: S BRÖCKSKES · D-VIERSEN · X R 615 FRNC 7 x 0,5 mm2 C Conductor: Technical data: bare copper strands with reference to IEC 60228, EN 6028, VDE 0295, class 5 Peak operating voltage: < 0.25 mm2 = max. 350 V ≥ 0.25 mm2 = max. 500 V Insulation: special A Testing voltage: Colour code: with reference to DIN 47100 < 0.25 mm2 = 800 V ≥ 0.25 mm2 = 1200 V Stranding: in layers Wrapping: foil Screen: tinned copper braiding Sheath material: special A Sheath colour: grey (RAL 7032) Outstanding features: ® halogen-free ® good EMC characteristics* ® no flame propagation ® flame retardant and self-extinguishing ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 ® tested acc. to American ASTM standard ® flame retardant acc. to UN/ECE R118 Min. bending radius fixed laying: flexible application: 5xd 10 x d Temperature range fixed laying: flexible application: -40/+90 °C -30/+90 °C Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Burning tests acc. to ASTM E 162-09. Flame retardant acc. to ISO 6722 (UN/ECE R118) Toxicity: acc. to DIN EN 50305 Smoke density: acc. to DIN EN 61034 + ASTM E 662-09 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union * Copper braiding should be connected circularly to optimize * the EMC characteristics item no. 66150214 66150314 66150414 66150514 66150714 66150814 66151014 66151214 66151414 66151614 66151814 66152114 66152414 66152714 66153014 66153214 66153614 66154014 66154414 66155014 66155214 66156114 66150225 66150325 66150425 66150525 66150725 66150825 66151025 12 no. of cores x cross section n x mm2 2 x 0,14 3 x 0,14 4 x 0,14 5 x 0,14 7 x 0,14 8 x 0,14 10 x 0,14 12 x 0,14 14 x 0,14 16 x 0,14 18 x 0,14 21 x 0,14 24 x 0,14 27 x 0,14 30 x 0,14 32 x 0,14 36 x 0,14 40 x 0,14 44 x 0,14 50 x 0,14 52 x 0,14 61 x 0,14 2 x 0,25 3 x 0,25 4 x 0,25 5 x 0,25 7 x 0,25 8 x 0,25 10 x 0,25 outer-ø ± 5% mm 3,6 3,8 4,0 4,3 4,6 5,4 5,8 6,2 6,4 6,7 7,0 7,6 8,0 8,6 8,8 9,1 9,4 10,0 10,6 11,0 11,0 11,6 3,9 4,1 4,4 4,9 5,3 6,1 6,6 www.sab-cable.com copper figure kg/km 12,6 14,1 15,9 19,5 24,0 26,0 29,0 32,0 35,0 49,0 54,0 60,0 74,0 85,0 98,0 108,0 117,0 126,0 138,0 150,0 155,0 176,0 15,0 18,0 22,0 25,0 32,0 35,0 42,0 cable weight ≈ kg/km 21 22 24 29 33 43 47 54 60 67 72 84 89 104 112 118 128 141 162 175 179 203 24 26 31 38 46 58 64 item no. 66151225 66151425 66151625 66151825 66152125 66152425 66152725 66153025 66153225 66153625 66154025 66154425 66155025 66155225 66156125 66150234 66150334 66150434 66150534 66150734 66150834 66151034 66151234 66151434 66151634 66151834 66152134 66152434 66152734 no. of cores x cross section n x mm2 12 x 0,25 14 x 0,25 16 x 0,25 18 x 0,25 21 x 0,25 24 x 0,25 27 x 0,25 30 x 0,25 32 x 0,25 36 x 0,25 40 x 0,25 44 x 0,25 50 x 0,25 52 x 0,25 61 x 0,25 2 x 0,34 3 x 0,34 4 x 0,34 5 x 0,34 7 x 0,34 8 x 0,34 10 x 0,34 12 x 0,34 14 x 0,34 16 x 0,34 18 x 0,34 21 x 0,34 24 x 0,34 27 x 0,34 outer-ø ± 5% mm 6,8 7,1 7,4 7,8 8,8 9,3 9,5 9,8 10,1 10,7 11,3 11,8 12,7 12,7 13,4 4,5 4,9 5,3 5,7 6,4 7,2 7,8 8,0 8,8 9,2 9,7 10,7 11,3 11,5 copper figure kg/km cable weight ≈ kg/km 50,0 72 64,0 80 71,0 89 80,0 98 105,0 122 115,0 130 120,0 142 132,0 152 138,0 161 152,0 189 164,0 209 180,0 221 222,0 254 234,0 260 287,0 295 17,0 31 21,0 36 25,0 43 30,0 51 42,0 63 45,0 78 63,0 87 70,0 97 78,0 118 87,0 129 108,0 144 127,0 177 140,0 193 151,0 207 Continued on next page Tested at reference types. Construction: CABLES FOR RAILWAY TECHNOLOGY SR 615 FRNC t acc. to tardan Flame re S Rail Data with overall copper screen 3 item no. 66153034 66153234 66153634 66154034 66154434 66155034 66155234 66156134 66150250 66150350 66150450 66150550 66150750 66150850 66151050 66151250 66151450 66151650 66151850 66152150 66152450 66152750 66153050 66153250 66153650 66154450 66155050 66156150 5-2 E N 4554 U N / ECE R118 BRÖCKSKES · D-VIERSEN · X R 615 FRNC 7 x 0,5 Marking for X R 615 FRNC 66150750: S BRÖCKSKES · D-VIERSEN · X R 615 FRNC 7 x 0,5 mm2 C no. of cores x cross section n x mm2 30 x 0,34 32 x 0,34 36 x 0,34 40 x 0,34 44 x 0,34 50 x 0,34 52 x 0,34 61 x 0,34 2 x 0,50 3 x 0,50 4 x 0,50 5 x 0,50 7 x 0,50 8 x 0,50 10 x 0,50 12 x 0,50 14 x 0,50 16 x 0,50 18 x 0,50 21 x 0,50 24 x 0,50 27 x 0,50 30 x 0,50 32 x 0,50 36 x 0,50 44 x 0,50 50 x 0,50 61 x 0,50 outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 11,9 12,7 13,2 14,0 14,6 15,8 15,8 16,7 5,0 5,2 5,6 6,3 6,8 7,8 8,8 9,0 9,4 9,9 10,6 11,6 12,6 12,8 13,2 13,7 14,2 16,4 17,0 18,0 162,0 171,0 188,0 208,0 223,0 248,0 273,0 316,0 23,5 28,4 35,1 41,6 53,1 62,0 74,5 84,2 93,5 105,9 133,9 154,9 169,7 184,2 203,6 213,5 239,0 309,2 349,7 403,7 222 247 272 301 319 386 395 366 39 42 50 63 76 94 113 126 139 156 185 220 240 260 283 299 330 422 469 540 item no. 66150275 66150375 66150475 66150575 66150775 66150875 66151275 66151475 66151675 66151875 66152175 66152475 66152775 66153075 66153275 66153675 66150280 66150380 66150480 66150580 66150680 66150780 66150285 66150385 66150485 66150585 66150685 66150785 no. of cores x cross section n x mm2 2 x 0,75 3 x 0,75 4 x 0,75 5 x 0,75 7 x 0,75 8 x 0,75 12 x 0,75 14 x 0,75 16 x 0,75 18 x 0,75 21 x 0,75 24 x 0,75 27 x 0,75 30 x 0,75 32 x 0,75 36 x 0,75 2 x 1,00 3 x 1,00 4 x 1,00 5 x 1,00 6 x 1,00 7 x 1,00 2 x 1,50 3 x 1,50 4 x 1,50 5 x 1,50 6 x 1,50 7 x 1,50 outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 5,6 6,1 6,6 7,1 7,7 9,2 10,5 11,0 11,5 12,4 13,6 14,4 14,7 15,8 16,3 16,9 5,8 6,3 6,8 7,4 8,0 8,0 6,6 6,8 7,4 8,6 9,3 9,3 30,3 37,6 46,5 55,7 74,0 83,8 133,9 148,5 169,2 184,0 211,0 239,1 260,9 313,4 328,3 357,8 35,2 46,4 57,9 69,6 81,3 90,9 46,5 62,7 79,2 95,8 112,7 127,1 48 56 73 81 101 132 179 198 224 257 297 324 352 417 440 479 53 65 78 95 111 117 71 90 98 130 152 162 Other dimensions and colours are possible on request. www.sab-cable.com 13 CABLES FOR RAILWAY TECHNOLOGY SR 645 FRNC TP 5-2 E N 4554 t acc. to tardan Flame re S Rail Data, paired with overall copper screen U N / ECE R118 3 -VIERSEN · X R 645 FRNC TP 3 x 2 x 0,25 mm2 C Marking for X R 645 FRNC TP 66450325: S BRÖCKSKES · D-VIERSEN · X R 645 FRNC TP 3 x 2 x 0,25 mm2 C Conductor: Technical data: bare copper strands with reference to IEC 60228, EN 6028, VDE 0295, class 5 Peak operating voltage: < 0.25 mm2 = max. 350 V ≥ 0.25 mm2 = max. 500 V Insulation: special A Testing voltage: Colour code: with reference to DIN 47100 < 0.25 mm2 = 800 V ≥ 0.25 mm2 = 1200 V Stranding: pairwise, pairs in layers Wrapping: foil Screen: tinned copper braiding Sheath material: special A Sheath colour: grey (RAL 7032) Outstanding features: ® Min. bending radius fixed laying: flexible application: 5xd 10 x d Temperature range fixed laying: flexible application: -40/+90 °C -30/+90 °C Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Burning tests acc. to ASTM E 162-09. Flame retardant acc. to ISO 6722 (UN/ECE R118) Toxicity: acc. to DIN EN 50305 halogen-free ® no flame propagation ® good EMC characteristics* ® ® flame retardant and self-extinguishing fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 ® tested acc. to American ASTM standard ® flame retardant acc. to UN/ECE R118 ® good transmission rates and crosstalk attenuation Smoke density: acc. to DIN EN 61034 + ASTM E 662-09 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union * Copper braiding should be connected circularly to optimize * the EMC characteristics item no. 66450214 66450314 66450414 66450514 66450614 66450814 66451014 66451214 66451614 66451814 66452414 66450225 66450325 66450425 66450525 66450625 66450825 66451025 66451225 66451625 66451825 66452425 66450234 66450334 66450434 66450534 66450634 14 no. of pairs x cross section n x 2 x mm2 outer-ø ± 10% mm copper figure kg/km 2 x 2 x 0,14 3 x 2 x 0,14 4 x 2 x 0,14 5 x 2 x 0,14 6 x 2 x 0,14 8 x 2 x 0,14 10 x 2 x 0,14 12 x 2 x 0,14 16 x 2 x 0,14 18 x 2 x 0,14 24 x 2 x 0,14 2 x 2 x 0,25 3 x 2 x 0,25 4 x 2 x 0,25 5 x 2 x 0,25 6 x 2 x 0,25 8 x 2 x 0,25 10 x 2 x 0,25 12 x 2 x 0,25 16 x 2 x 0,25 18 x 2 x 0,25 24 x 2 x 0,25 2 x 2 x 0,34 3 x 2 x 0,34 4 x 2 x 0,34 5 x 2 x 0,34 6 x 2 x 0,34 5,2 5,7 6,5 7,0 7,2 7,8 8,9 9,7 10,5 11,1 12,8 5,7 6,4 7,2 7,7 7,9 9,0 9,8 10,9 11,9 12,7 14,2 6,8 7,4 8,8 9,5 9,7 19,1 23,4 27,8 31,9 36,2 43,4 50,6 58,2 71,4 92,8 114,8 24,9 31,4 39,3 45,8 50,7 62,1 73,9 101,9 126,8 136,6 170,3 31,5 39,7 49,8 58,5 65,1 www.sab-cable.com cable weight ≈ kg/km 38 44 54 64 71 83 105 121 147 174 223 46 61 72 83 92 119 138 173 213 245 296 63 79 102 121 125 item no. 66450834 66451234 66451634 66451834 66452434 66450250 66450350 66450450 66450550 66450650 66450850 66451050 66451250 66451650 66451850 66452450 66450275 66450375 66450475 66450575 66450675 66450875 66451275 66451675 66451875 66452475 no. of pairs x cross section n x 2 x mm2 outer-ø ± 10% mm copper figure kg/km 8 x 2 x 0,34 12 x 2 x 0,34 16 x 2 x 0,34 18 x 2 x 0,34 24 x 2 x 0,34 2 x 2 x 0,50 3 x 2 x 0,50 4 x 2 x 0,50 5 x 2 x 0,50 6 x 2 x 0,50 8 x 2 x 0,50 10 x 2 x 0,50 12 x 2 x 0,50 16 x 2 x 0,50 18 x 2 x 0,50 24 x 2 x 0,50 2 x 2 x 0,75 3 x 2 x 0,75 4 x 2 x 0,75 5 x 2 x 0,75 6 x 2 x 0,75 8 x 2 x 0,75 12 x 2 x 0,75 16 x 2 x 0,75 18 x 2 x 0,75 24 x 2 x 0,75 10,6 13,4 14,6 15,1 17,6 7,2 7,9 9,4 10,2 10,4 11,4 13,2 14,4 16,3 16,9 19,0 8,5 9,4 10,9 11,7 12,5 13,7 17,1 18,6 19,3 21,8 80,7 133,1 165,0 178,3 255,1 39,3 50,1 64,6 76,3 86,0 126,6 146,5 175,6 241,3 261,0 330,4 52,4 69,4 101,9 121,9 136,5 170,1 261,2 329,9 369,3 469,2 cable weight ≈ kg/km 159 248 305 334 449 72 92 119 141 155 179 252 294 380 436 508 102 128 166 201 239 279 419 522 580 714 Other dimensions and colours are possible on request. Tested at reference types. Construction: CABLES FOR RAILWAY TECHNOLOGY 5-2 E N 4554 CAT 5e R CAT 6A R halogen-free Industrial Ethernet Cables CAT 7A R 3 t acc. to tardan Flame re U N / ECE D-VIERSEN · S BRÖCKSKES · D-VIERSEN · Construction: CAT 5e R Marking for CATLine CAT 5e R 15674421: Cat.5e R 4x2x24AWG 1567-4421 C CAT 7A R flexible flexible 2 x 2 x 24 AWG / 2 x 2 x 22 AWG / 4 x 2 x 24 AWG Dimension : Cat.5e R 4x2x24AWG 1567-442 CAT 6A R flexible R118 4 x 2 x 26 AWG Conductor: bare copper strands, fine wires Insulation: PE Colour code: blue, yellow, white, orange Stranding: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown star quad twisted to pairs Wrapping: twisted to pairs with alu foil foil Screen: alu foil and tinned copper braiding Sheath material: special S Sheath colour: green (similar RAL 6018) Technical data: CAT 5e R Item number: CAT 6A R CAT 7A R flexible flexible flexible 1567-9002 / 1567-9004 / 1567-4421 1667-4621 1767-4621 Peak operating voltage: max. 90 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: - 40°C / + 70°C - 30°C / + 70°C 5xd 12 x d Characteristic impedance: 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-2-2 / CAT 5 Halogen-free: 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A 1100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A acc. to DIN EN 50306-1 + DIN EN 50264-1. Development of HCl is ≤ 0,5% acc. to DIN EN 50267-2-1. pH-value is ≥ 4,3 acc. to DIN EN 50267-2-2. Conductivity is ≤ 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content ≤ 0,1% acc. to DIN EN 60684-2 Fire performance: No flame propagation acc. to DIN EN 60332-3-25 + DIN EN 50305 section 9.1.1 + 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2 Smoke density: acc. to DIN EN 61034 Toxizität: acc. to DIN EN 50305 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union Outstanding features: ® halogen-free ® no flame propagation ® flame retardant and self-extinguishing ® fulfils fire protection R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 item no. type 15679002 15679004 15674421 16674621 17674621 CATLine CAT 5e R CATLine CAT 5e R CATLine CAT 5e R CATLine CAT 6A R CATLine CAT 7A R no. of cores 4 4 8 8 8 cross section AWG 24 22 24 26 26 max. core-ø mm max. 1,30 max. 1,60 max. 1,30 max. 1,05 max. 1,60 outer-ø ± 5% mm 5,2 5,9 8,0 6,8 8,8 copper figure kg/km 22,7 29,1 41,2 36,3 38,5 cable weight ≈kg/km 41 52 70 58 82 Other dimensions and colours are possible on request. www.sab-cable.com 15 CABLES FOR RAILWAY TECHNOLOGY 5-2 E N 4554 SA 280 FRNC X +125°C up to Wiring cable / Control cable 3 s BRÖCKSKES · D-VIERSEN · X A 280 FRNC X 1 x 1,0 mm2 C Marking for X A 280 FRNC X 1 x 1,0 mm2: S BRÖCKSKES · D-VIERSEN · X A 280 FRNC X 1 x 1,0 mm2 C s BRÖCKSKES · D-VIERSEN · X A 280 FRNC X 5 x 0,5 mm2 C Marking for X A 280 FRNC X 5 x 0,5 mm2: S BRÖCKSKES · D-VIERSEN · X A 280 FRNC X 12 x 0,5 mm2 C Construction: Conductor: tinned copper strands fine wires acc. to IEC 60228, EN 60228, VDE 0295, class 5 Insulation: special A Single conductor: Colour code: white (similar RAL 9010) Multi-core cable: Colour code: white cores with black numbers acc. to. EN 50334 Multi-core cable: Stranding: in layers Multi-core cable: Sheath material: special A Multi-core cable: Sheath colour: black (RAL 9005) item no. 62800105 62800305 62800505 62800805 62801005 62801205 62800607 62800807 62801007 62800110 62800310 62800410 62800610 62800810 62801010 62800115 62800315 62800125 Technical data: Nominal voltage: Uo/U 300/500 V Testing voltage U: 2000 V Min. bending radius: 5xd Temperature range during protected, fixed laying: -40/+125 °C (single conductor) -50/+125 °C (multi-core cable) Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Outstanding features: Toxicity: acc. to DIN EN 50305 ® halogen-free Smoke density: acc. to DIN EN 610341 ® no flame propagation ® flame retardant and self-extinguishing Absence of harmful substances: acc. to RoHS directive of the European Union ® good ozone resistance ® good oil and chemical resistance ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 no. of cores x cross section largest single wire outer-ø ± 5% copper figure cable weight ≈ kg/km ohmic resistance at 20°C max. Ω/km heating value approx. kWh/km n x mm2 ø mm mm kg/km 1 x 0,50 3 x 0,50 5 x 0,50 8 x 0,50 10 x 0,50 12 x 0,50 6 x 0,75 8 x 0,75 10 x 0,75 1 x 1,00 3 x 1,00 4 x 1,00 6 x 1,00 8 x 1,00 10 x 1,00 1 x 1,50 3 x 1,50 1 x 2,50 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,26 1,7 4,7 5,8 7,3 8,1 8,4 7,2 7,3 9,4 2,1 5,5 6,2 7,5 9,0 10,1 2,5 6,6 3,1 4,8 14,4 24,0 38,4 48,0 57,6 43,2 57,6 72,0 9,6 28,8 38,4 57,6 76,8 96,0 14,4 43,2 24,0 7 35 50 83 97 112 86 101 133 12 55 71 101 135 164 17 68 27 40,1 40,1 40,1 40,1 40,1 40,1 26,7 26,7 26,7 20,0 20,0 20,0 20,0 20,0 20,0 13,7 13,7 8,21 13,0 115 170 246 275 306 237 245 345 16,0 162 186 252 338 402 22,5 210 34,0 Other dimensions and colours are possible on request. 16 www.sab-cable.com CABLES FOR RAILWAY TECHNOLOGY SA 285 FRNC X +125°C up to Control cable with numbered cores and overall copper screen 3 5-2 E N 4554 BRÖCKSKES · D-VIERSEN · X A 285 FRNC X 5 x 0, Marking for X A 285 FRNC X 5 x 0,5 mm2: S BRÖCKSKES · D-VIERSEN · X A 285 FRNC X 5 x 0,5 mm2 C Construction: Conductor: Technical data: tinned copper strands fine wires acc. to IEC 60228, EN 60228, VDE 0295, class 5 Insulation: special A Colour code: white cores with black numbers acc. to. EN 50334 Stranding: in layers Wrapping: foil Screen: tinned copper braiding Sheath material: special A Sheath colour: black (RAL 9005) Nominal voltage: Uo/U 300/500 V Testing voltage U: 2000 V Min. bending radius: 10 x d Temperature range during protected, fixed laying: Outstanding features: -50/+125 °C Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. ® halogen-free ® good EMC characteristics* ® no flame propagation Toxicity: acc. to DIN EN 50305 ® flame retardant and self-extinguishing Smoke density: acc. to DIN EN 61034 ® good ozone resistance ® good oil and chemical resistance Absence of harmful substances: acc. to RoHS directive of the European Union ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 * Copper braiding should be connected circularly to optimize * the EMC characteristics item no. 62850305 62850505 62850805 62851005 62851205 62850607 62850807 62851007 62850310 62850610 62850810 62851010 no. of cores x cross section largest single wire outer-ø ± 5% copper figure cable weight ≈ kg/km ohmic resistance at 20°C max. Ω/km heating value approx. kWh/km n x mm2 ø mm mm kg/km 3 x 0,50 5 x 0,50 8 x 0,50 10 x 0,50 12 x 0,50 6 x 0,75 8 x 0,75 10 x 0,75 3 x 1,00 6 x 1,00 8 x 1,00 10 x 1,00 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 5,2 6,3 7,9 8,6 8,9 7,7 9,1 10,4 6,2 8,2 9,8 10,8 30,3 43,5 62,2 74,3 86,6 67,0 86,6 119,7 46,5 83,7 106,0 149,9 45 68 97 114 127 101 132 172 66 125 160 200 40,1 40,1 40,1 40,1 40,1 26,7 26,7 26,7 20,0 20,0 20,0 20,0 99 154 237 258 288 231 305 381 155 285 366 401 Other dimensions and colours are possible on request. www.sab-cable.com 17 CABLES FOR RAILWAY TECHNOLOGY SA 280 FRNC X (FR) Fire resistant control cable 5-2 E N 4554 21 31I EC 603 0 E N 5020 3 s BRÖCKSKES · D-VIERSEN · X A 280 FRNC X (FR) 25 x 0,5 mm2 C Marking for X A 280 FRNC X (FR) 25 x 0,5 mm2: S BRÖCKSKES · D-VIERSEN · X A 280 FRNC X (FR) 25 x 0,5 mm2 C Construction: Conductor: tinned copper strands fine wires acc. to IEC 60228, EN 60228, VDE 0295, class 5 Wrapping: mica tape Insulation: special A Colour code: white cores with black numbers acc. to. EN 50334 Stranding: in layers Sheath material: special A Sheath colour: black (RAL 9005) Outstanding features: ® halogen-free ® no flame propagation ® fire resistant ® flame retardant and self-extinguishing ® good ozone resistance ® good oil and chemical resistance ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 ® EN 50200 PH 30 / IEC 60331-21 q 18 Technical data: Nominal voltage: Uo/U 300/500 V Testing voltage U: 2000 V Min. bending radius: 10 x d Temperature range during protected, fixed laying: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. Insulation integrity in case of fire: EN 50200 PH 30 IEC 60331-21 FE 180 Toxicity: acc. to DIN EN 50305 Smoke density: acc. to DIN EN 61034 Absence of harmful substances: acc. to RoHS directive of the European Union Available dimensions: 2-25 cores with cross sections from 0,5 mm2 to 2,5 mm2. Other dimensions on request! www.sab-cable.com -50/+125 °C Halogen-free: CABLES FOR RAILWAY TECHNOLOGY 5-2 E N 4554 R 107 Besilen® insulated copper rope 3 D-VIERSEN · R 107 · 1,8/3 kV 25,0 mm² 6107-0890 Marking for R 107 61070890: S BRÖCKSKES · D-VIERSEN · R 107 · 1,8/3 kV 25,0 mm² 6107-0890 Construction: Technical data: Conductor: bare copper strands, extremely fine wires Nominal voltage: Insulation: Besilen® EI2 acc. to DIN EN 50363-1 Testing voltage: 6500 V Colour: slate-gray (RAL 7015) Min. bending radius: 5xd Temperature range fixed laying: flexible application: short-time use: -50/+180 °C -25/+180 °C -25/+250 °C Outstanding features: item no. 61070882 61070884 61070886 61070887 61070888 61070889 61070890 61070891 61070892 61070893 61070894 61070895 61070896 61070897 Uo/U 1,8/3,0 kV Halogen-free: acc. to EN 50306-1 + EN 50264-1 are fulfilled. Development of HCl is < 0,5% acc. to DIN EN 50267-2-1. pH-value is > 4,3 acc. to DIN EN 50267-2-2. Conductivity is < 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content < 0,1% acc. to DIN EN 60684-2. Fire performance: No flame propagation acc. to DIN EN 60332-3-24, DIN EN 60332-3-25 and DIN EN 50305 section 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2. acc. to DIN EN 50305 ® extremely flexible ® fulfils fire protection requirements acc. to DIN EN 45545-2 / R15 (EL1A) HL 1-2 / R16 (EL1B) HL 1-3 Toxicity: ® halogen-free Smoke density: acc. to DIN EN 61034 ® heat resistant Weather resistance: very good ® flexible at low temperatures Ozone resistance: acc. to DIN EN 50382-2 ® flame retardant and self-extinguishing Oil resistance: good ® weather resistant Absence of harmful substances: acc. to RoHS directive of the European Union nominal cross section mm2 1,50 2,50 4,00 6,00 10,00 16,00 25,00 35,00 50,00 70,00 95,00 120,00 150,00 185,00 largest single wire ø mm outer-ø ± 5% mm 0,07 0,07 0,07 0,07 0,07 0,07 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,15 6,9 7,4 8,1 8,5 10,0 10,3 12,1 13,8 15,7 17,7 19,2 20,9 24,1 25,3 copper figure kg/km 14,4 24,0 38,4 57,6 96,0 153,6 240,0 336,0 480,0 672,0 912,0 1152,0 1440,0 1776,0 cable weight ≈ kg/km 62 76 97 119 171 222 328 435 591 788 1041 1281 1588 1911 On request with tinned copper strands! q Also available with copper braiding as R 108! Other dimensions and colours are possible on request. Besilen® is a specially developed Silicone rubber-based material with good electrical characteristics and it is a registered trademark of S BRÖCKSKES GmbH & Co. KG. www.sab-cable.com 19 CABLES FOR RAILWAY TECHNOLOGY up to V 1,8/3,0 k B 107 Besilen® insulated strands 3 BRÖCKSKES · D-VIERSEN · B 107 · Uo/U 1,8/3 kV Marking for B 107 01071000: S BRÖCKSKES · D-VIERSEN · B 107 · Uo/U 1,8/3 kV Construction: Conductor: bare copper strands, extra fine wires Insulation: Besilen® EI2 acc. to DIN EN 50363-1 Colour: translucent Technical data: Outstanding features: 01070400 01070600 01071000 01071600 01072500 01073500 01075000 01077000 01079500 01071200 01071500 01071850 Testing voltage 4,0 - 6,0 mm2: 10,0 - 150,0 mm2: 4000 V 6000 V Min. bending radius: 5xd Temperature range fixed laying: flexible application: short-time use: -50/+180 °C -25/+180 °C -25/+250 °C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2 IEC 60754-2 + EN 50267-2-2 + VDE 0482 part 267-2-2 – no development of corrosive conflagration gases halogen-free ® heat resistant ® flexible at low temperatures ® flame retardant and self-extinguishing Weather resistance: very good weather resistant Absence of harmful substances: acc. to RoHS directive of the European Union nominal cross section mm2 4,00 6,00 10,00 16,00 25,00 35,00 50,00 70,00 95,00 120,00 150,00 185,00 Corrosiveness of conflagration gases: largest single wire ø mm outer-ø ± 5% mm 0,07 0,07 0,07 0,07 0,10 0,10 0,10 0,10 0,10 0,10 0,10 0,15 5,3 5,7 9,0 9,3 12,0 13,8 15,7 17,7 18,8 22,0 23,7 25,3 copper figure kg/km 38,4 57,6 96,0 153,6 240,0 336,0 480,0 672,0 912,0 1152,0 1440,0 1776,0 cable weight ≈ kg/km 54 73 114 194 331 422 576 771 1006 1257 1542 1884 Other dimensions and colours are possible on request. Besilen® 20 Uo/U 1,5/1,5 kV Uo/U 1,8/3,0 kV ® ® item no. Nominal voltage 4,0 - 6,0 mm2: 10,0 - 150,0 mm2: is a specially developed Silicone rubber-based material with good electrical characteristics and it is a registered trademark of S BRÖCKSKES GmbH & Co. KG. www.sab-cable.com On request with tinned copper strands! q Also available with copper braiding as B 108! CABLES FOR RAILWAY TECHNOLOGY acc. to 070 N F C32- C1 C A 224 FRNC C1 Control cable with numbered cores 3 D-VIERSEN · X A 224 FRNC C1 50 x 0,5 mm2 C Marking for X A 224 FRNC C1 62245005: S BRÖCKSKES · D-VIERSEN · X A 224 FRNC C1 50 x 0,5 mm2 C Construction: Conductor: Technical data: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: Uo/U 450/750 V Insulation: A Testing voltage U: 3000 V Colour code: black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Min. bending radius fixed laying: flexible application: 4xd 6xd Stranding: in layers Sheath material: A Temperature range fixed laying: flexible application: -30/+90 °C -20/+90 °C Sheath colour: black (RAL 9005) Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Fire performance: Smoke density: No flame propagation acc. to IEC 60332 + EN 50266 cat. C resp. D. Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2 + NF C32-070 C1. in compliance with IEC 60754-2 and EN 50267-2-2 + VDE 0482 part 267-2-2 no development of corrosive conflagration gases acc. to IEC 61034 + EN 61034 Absence of harmful substances: acc. to RoHS directive of the European Union Outstanding features: item no. 62240205 62240305 62240405 62240505 62240705 62240805 62240905 62241005 62241205 62241405 62241605 62241805 62242105 62242505 62243005 62243405 62244005 62244205 62245005 62246105 62240207 62240307 62240407 62240507 62240707 62240807 62240907 62241007 62241207 62241407 ® halogen-free ® no flame propagation ® flame retardant and self-extinguishing ® NF C32-070 C1 no. of cores x cross section n x mm2 2 x 0,50 3 x 0,50 4 x 0,50 5 x 0,50 7 x 0,50 8 x 0,50 9 x 0,50 10 x 0,50 12 x 0,50 14 x 0,50 16 x 0,50 18 x 0,50 21 x 0,50 25 x 0,50 30 x 0,50 34 x 0,50 40 x 0,50 42 x 0,50 50 x 0,50 61 x 0,50 2 x 0,75 3 x 0,75 4 x 0,75 5 x 0,75 7 x 0,75 8 x 0,75 9 x 0,75 10 x 0,75 12 x 0,75 14 x 0,75 Corrosiveness of conflagration gases: largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km item no. 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 5,8 6,3 6,8 7,7 8,3 9,8 10,6 10,8 11,1 11,6 12,5 13,1 14,6 15,9 16,6 18,1 19,6 19,6 21,4 22,9 6,4 7,0 7,8 8,5 9,4 11,0 12,0 12,2 12,6 13,2 9,6 14,4 19,2 24,0 33,6 38,4 43,2 48,0 57,6 67,2 76,8 86,4 100,8 120,0 144,0 163,2 192,0 201,6 240,0 292,8 14,4 21,6 28,8 36,0 50,4 57,6 64,8 72,0 86,4 100,8 36 49 59 76 94 118 135 140 159 179 207 228 271 315 369 424 497 514 602 718 45 61 79 95 125 154 178 184 209 236 62241607 62241807 62242107 62242507 62243007 62243407 62244007 62244207 62245007 62246107 62240210 62240310 62240410 62240510 62240710 62240810 62240910 62241010 62241210 62241410 62241610 62241810 62242110 62242510 62243010 62243410 62244010 62244210 62245010 62246110 no. of cores x cross section n x mm2 16 x 0,75 18 x 0,75 21 x 0,75 25 x 0,75 30 x 0,75 34 x 0,75 40 x 0,75 42 x 0,75 50 x 0,75 61 x 0,75 2 x 1,00 3 x 1,00 4 x 1,00 5 x 1,00 7 x 1,00 8 x 1,00 9 x 1,00 10 x 1,00 12 x 1,00 14 x 1,00 16 x 1,00 18 x 1,00 21 x 1,00 25 x 1,00 30 x 1,00 34 x 1,00 40 x 1,00 42 x 1,00 50 x 1,00 61 x 1,00 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21 14,1 15,0 16,6 18,2 18,8 20,4 22,2 22,2 24,4 26,0 6,8 7,2 8,0 8,8 9,7 11,4 12,4 12,6 13,0 13,8 14,6 15,5 17,2 18,8 19,6 21,3 23,0 23,0 25,4 27,1 115,2 129,6 151,2 180,0 216,0 244,8 288,0 302,4 360,0 439,2 19,2 28,8 38,4 48,0 67,2 76,8 86,4 96,0 115,2 134,4 153,6 172,8 201,6 240,0 288,0 326,4 384,0 403,2 480,0 585,6 272 308 363 424 487 557 661 685 803 957 53 69 89 108 142 174 200 209 239 277 311 352 415 485 568 649 759 787 953 1116 Continued on next page www.sab-cable.com 21 CABLES FOR RAILWAY TECHNOLOGY acc. to 070 N F C32- C1 CA 224 FRNC C1 Control cable with numbered cores 3 D-VIERSEN · X A 224 FRNC C1 50 x 0,5 mm2 C Marking for X A 224 FRNC C1 62245005: S BRÖCKSKES · D-VIERSEN · X A 224 FRNC C1 50 x 0,5 mm2 C item no. 62240215 62240315 62240415 62240515 62240715 62240815 62240915 62241015 62241215 62241415 62241615 62241815 62242115 62242515 62243015 62243415 62244015 62244215 62245015 62246115 62240225 62240325 62240425 62240525 62240725 62240825 62240925 62241025 no. of cores x cross section n x mm2 2 x 1,50 3 x 1,50 4 x 1,50 5 x 1,50 7 x 1,50 8 x 1,50 9 x 1,50 10 x 1,50 12 x 1,50 14 x 1,50 16 x 1,50 18 x 1,50 21 x 1,50 25 x 1,50 30 x 1,50 34 x 1,50 40 x 1,50 42 x 1,50 50 x 1,50 61 x 1,50 2 x 2,50 3 x 2,50 4 x 2,50 5 x 2,50 7 x 2,50 8 x 2,50 9 x 2,50 10 x 2,50 q 22 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km item no. 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 7,4 8,0 8,7 9,8 10,8 12,7 13,7 14,0 14,4 15,3 16,4 17,2 19,3 21,0 21,7 23,8 25,7 25,7 28,3 30,2 8,8 9,5 10,6 11,6 12,8 15,2 16,5 16,8 28,8 43,2 57,6 72,0 100,8 115,2 129,6 144,0 172,8 201,6 230,4 259,2 302,4 360,0 432,0 489,6 576,0 604,8 720,0 878,4 48,0 72,0 96,0 120,0 168,0 192,0 216,0 240,0 65 89 111 140 185 226 258 270 309 358 412 456 547 643 743 859 1004 1041 1239 1480 96 132 170 208 275 340 388 407 62241225 62241425 62241625 62241825 62242125 62242525 62240340 62240440 62240540 62240740 62240360 62240460 62240560 62240760 62240461 62240561 62240761 62240462 62240562 62240762 62240463 62240563 62240763 62240464 62240564 62240764 62240465 Screened version on request! www.sab-cable.com no. of cores x cross section n x mm2 12 x 2,50 14 x 2,50 16 x 2,50 18 x 2,50 21 x 2,50 25 x 2,50 3 x 4,00 4 x 4,00 5 x 4,00 7 x 4,00 3 x 6,00 4 x 6,00 5 x 6,00 7 x 6,00 4 x 10,0 5 x 10,0 7 x 10,0 4 x 16,0 5 x 16,0 7 x 16,0 4 x 25,0 5 x 25,0 7 x 25,0 4 x 35,0 5 x 35,0 7 x 35,0 4 x 50,0 largest single wire ø mm outer-ø ± 5% mm 0,26 0,26 0,26 0,26 0,26 0,26 0,31 0,31 0,31 0,31 0,31 0,31 0,31 0,31 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 17,3 18,4 19,6 20,8 23,0 25,3 11,0 12,2 13,6 15,0 12,7 14,1 15,7 17,3 18,0 25,1 25,1 25,2 25,3 27,1 24,4 27,2 30,2 27,8 31,2 34,5 34,6 copper figure kg/km 288,0 336,0 384,0 432,0 504,0 600,0 115,2 153,6 192,0 268,8 172,8 230,4 288,0 403,2 384,0 480,0 672,0 614,4 768,0 1075,2 960,0 1200,0 1680,0 1344,0 1680,0 2352,0 1920,0 cable weight ≈ kg/km 469 543 622 700 824 971 187 243 304 403 263 341 426 568 566 984 1121 1026 1087 1403 1273 1598 2175 1750 2153 2982 2465 Other dimensions and colours are possible on request. CABLES FOR RAILWAY TECHNOLOGY C CC 625 FRNC M Control cable with numbered cores 3 Style 21089 75°C 60OV CSA AWM I/II A/B 80°C 600V FT1 C Marking for X CC 625 FRNC M 62521215: S BRÖCKSKES · D-VIERSEN · 62521215 12 x 1,5 mm2 X CC 625 FRNC M 16 AWG/12c 62521612 U AWM Style 21089 75°C 60OV CSA AWM I/II A/B 80°C 600V FT1 C Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: UL/CSA: 600 V DIN VDE: Uo/U 300/500 V Insulation: A Testing voltage: 3000 V acc. to DIN VDE 0281 part 2 + HD 21.2 Colour code: black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Min. bending radius fixed laying: flexible application: 4xd 6xd Stranding: in layers Sheath material: A Sheath colour: grey (RAL 7000) Temperature range fixed laying: flexible application: UL: up to +75 ˚C CSA: up to +80 °C DIN VDE: -40/+90 ˚C -30/+90 ˚C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Fire performance: ® flame retardant and self-extinguishing Smoke density: No flame propagation acc. to IEC 60332 + EN 50266 cat. C resp. D. Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2, CSA FT1 FT2. in compliance with IEC 60754-2 and EN 50267-2-2 + VDE 0482 part 267-2-2 no development of corrosive conflagration gases acc. to IEC 61034 + EN 61034 ® flexible Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union Outstanding features: item no. ® halogen-free ® UL recognized, CSA approved ® no flame propagation no. of cores outer-ø ± 5% mm ® 20 AWG (15/32) • 0,50 mm2 62520205 2 5,2 62520305 3 5,5 62520405 4 5,9 62520505 5 6,4 62520705 7 7,0 62520805 8 8,2 62520905 9 8,9 62521005 10 9,1 62521205 12 9,3 62521405 14 9,8 62521605 16 10,5 62521805 18 11,1 62522505 25 13,5 62523005 30 13,9 62523405 34 15,2 62524005 40 16,5 62524105 41 16,5 62526105 61 19,3 ® 19 AWG (23/32) • 0,75 mm2 62520207 2 5,7 62520307 3 6,0 62520407 4 6,5 62520507 5 7,1 62520707 7 7,9 62520807 8 9,3 62520907 9 9,9 62521007 10 10,1 62521207 12 10,6 62521407 14 11,1 62521607 16 11,9 62521807 18 12,5 62522507 25 15,2 62523007 30 15,7 62523407 34 17,1 62524007 40 18,6 62524107 41 18,6 62526107 61 22,0 copper figure kg/km 10,3 15,4 20,5 25,6 35,9 41,0 46,1 51,3 61,5 71,8 82,0 92,3 128,2 153,8 174,3 205,1 210,2 312,8 14,4 21,6 28,8 36,0 50,4 57,6 64,8 72,0 86,4 100,8 115,2 129,6 180,0 216,0 244,8 288,0 295,2 439,2 cable weight ≈ kg/km 40 47 56 65 83 104 118 120 136 154 177 196 270 310 355 421 428 608 48 57 69 81 106 132 145 149 175 197 226 250 344 397 453 535 545 786 Corrosiveness of conflagration gases: item no. no. of cores outer-ø ± 5% mm ® 18 AWG (30/32) • 1,00 mm2 62520210 2 5,9 62520310 3 6,3 62520410 4 6,8 62520510 5 7,5 62520710 7 8,2 62520810 8 9,6 62520910 9 10,5 62521010 10 10,7 62521210 12 11,0 62521410 14 11,5 62521810 18 13,0 62522510 25 15,8 62523010 30 16,6 62523410 34 18,0 62524010 40 19,5 62524110 41 19,5 62526110 61 22,9 copper figure kg/km cable weight ≈ kg/km 19,2 28,8 38,4 48,0 67,2 76,8 86,4 96,0 115,2 134,4 172,8 240,0 288,0 326,4 384,0 393,6 585,6 54 66 80 97 124 152 173 179 204 231 294 404 477 543 639 675 931 ® 16 AWG (27-29/30) • 1,50 mm2 62520215 2 6,5 28,8 62520315 3 6,9 43,2 62520415 4 7,6 57,6 62520515 5 8,3 72,0 62520715 7 9,3 100,8 62520815 8 10,9 115,2 62520915 9 11,8 129,6 62521015 10 12,1 144,0 62521215 12 12,4 172,8 62521415 14 13,0 201,6 62521815 18 14,9 259,2 62522515 25 18,1 360,0 62523015 30 18,7 432,0 62523415 34 20,5 489,6 62524015 40 22,2 576,0 62524115 41 22,2 590,4 62526115 61 26,0 878,4 69 85 105 129 166 202 228 240 274 311 404 558 647 747 874 883 1281 item no. no. of cores outer-ø copper figure kg/km cable weight ≈ kg/km ® 14 AWG (46/30) • 2,50 mm2 62520225 2 7,8 62520325 3 8,3 62520425 4 9,2 62520525 5 10,1 62520725 7 11,2 62520825 8 13,4 62520925 9 14,3 62521025 10 14,8 62521225 12 15,3 62521825 18 18,2 62522525 25 22,3 48,0 72,0 96,0 120,0 168,0 192,0 216,0 240,0 288,0 432,0 600,0 104 128 161 195 257 316 348 375 431 632 871 ® 12 AWG (52/28) • 4,00 mm2 62520340 3 9,7 62520440 4 10,8 62520540 5 12,1 62520740 7 13,4 115,2 153,6 192,0 268,8 188 238 295 388 ® 10 AWG (78/28) • 6,00 mm2 62520360 3 11,4 62520460 4 12,7 62520560 5 14,2 172,8 230,4 288,0 271 343 425 ® 8 AWG (77/26) • 10,00 mm2 62520461 4 17,2 62520561 5 19,3 384,0 480,0 608 756 ® 6 AWG (119/26) • 16,00 mm2 62520462 4 21,1 614,4 909 ® 4 AWG (196/26) • 25,00 mm2 62520463 4 26,5 960,0 1475 ® 2 AWG (280/26) • 35,00 mm2 62520464 4 30,2 1344,0 2004 ± 5% mm Other dimensions and colours are possible on request. www.sab-cable.com 23 CABLES FOR RAILWAY TECHNOLOGY C CC 625 S FRNC M Control cable with numbered cores and overall copper screen 3 089 75°C 60OV CSA AWM I/II A/B 80°C 600V FT1 C Marking for X CC 625 S FRNC M 62341215: S BRÖCKSKES · D-VIERSEN · 62341215 12 x 1,5 mm2 X CC 625 S FRNC M 16 AWG/12c 62341612 U AWM Style 21089 75°C 60OV CSA AWM I/II A/B 80°C 600V FT1 C Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: UL/CSA: 600 V DIN VDE: Uo/U 300/500 V Insulation: A Testing voltage: Colour code: black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores 3000 V acc. to DIN VDE 0281 part 2 + HD 21.2 core/screen 1000 V Stranding: in layers Wrapping: PETP foil Screen: tinned copper braiding Sheath material: A Sheath colour: grey (RAL 7000) Min. bending radius fixed laying: flexible application: 5xd 10 x d Temperature range fixed laying: flexible application: UL: up to +75 ˚C CSA: up to +80 °C DIN VDE: -40/+90 ˚C -30/+90 ˚C Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Fire performance: Smoke density: No flame propagation acc. to IEC 60332 + EN 50266 cat. C resp. D. Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2, CSA FT1. in compliance with IEC 60754-2 and EN 50267-2-2 + VDE 0482 part 267-2-2 no development of corrosive conflagration gases acc. to IEC 61034 + EN 61034 Flexibility: good Absence of harmful substances: acc. to RoHS directive of the European Union Outstanding features: ® ® ® ® ® ® Corrosiveness of conflagration gases: halogen-free UL recognized, CSA approved no flame propagation good EMC characteristics* flame retardant and self-extinguishing flexible * Copper braiding should be connected circularly to optimize * the EMC characteristics item no. no. of cores outer-ø ± 5% mm ® 20 AWG (17/32) • 0,50 mm2 62340205 2 5,7 62340305 3 6,0 62340405 4 6,4 62340505 5 7,0 62340705 7 7,6 62340805 8 8,9 62340905 9 9,4 62341005 10 9,6 62341205 12 9,8 62341405 14 10,7 62341605 16 11,2 62341805 18 12,0 62342505 25 13,8 62343005 30 15,0 62343405 34 16,3 62344005 40 17,6 62344105 41 17,6 62346105 61 20,2 ® 19 AWG (23/32) • 0,75 mm2 62340207 2 6,2 62340307 3 6,5 62340407 4 7,0 62340507 5 7,8 62340707 7 8,4 62340807 8 9,8 62340907 9 10,8 62341007 10 11,0 62341207 12 11,3 62341407 14 12,0 62341607 16 12,6 62341807 18 13,2 62342507 25 16,3 62343007 30 16,8 62343407 34 18,2 62344007 40 19,7 62344107 41 19,7 62346107 61 22,9 24 copper figure kg/km 20,8 26,0 32,2 38,7 50,3 58,4 63,6 70,6 80,9 103,4 113,8 128,3 168,2 198,0 239,4 278,3 283,4 395,6 25,1 33,3 41,8 50,4 67,8 76,9 100,4 103,7 122,2 136,8 151,5 169,3 245,1 281,4 318,5 370,3 377,5 532,4 cable weight ≈ kg/km 45 54 64 76 96 121 131 136 152 188 206 234 306 361 429 503 514 693 52 64 77 94 118 145 181 182 207 235 259 286 416 468 534 625 635 879 item no. no. of cores outer-ø ± 5% mm ® 18 AWG (30/32) • 1,00 mm2 62340210 2 6,4 62340310 3 6,8 62340410 4 7,3 62340510 5 8,0 62340710 7 8,9 62340810 8 10,1 62340910 9 11,2 62341010 10 11,4 62341210 12 11,9 62341410 14 12,4 62341810 18 13,9 62342510 25 16,9 62343010 30 17,7 62343410 34 19,1 62344010 40 20,6 62344110 41 20,6 62346110 61 24,0 copper figure kg/km cable weight ≈ kg/km 30,9 41,8 51,5 63,7 84,6 96,2 118,2 131,8 151,2 170,6 216,7 312,8 361,3 400,7 467,1 476,7 687,8 58 73 87 107 139 165 200 210 241 268 340 483 556 629 730 742 1042 ® 16 AWG (27-29/30) • 1,50 mm2 62340215 2 7,0 41,8 62340315 3 7,5 57,5 62340415 4 8,1 73,4 62340515 5 9,0 89,4 62340715 7 9,8 120,1 62340815 8 11,8 151,1 62340915 9 12,5 165,8 62341015 10 12,8 183,6 62341215 12 13,3 212,5 62341415 14 13,9 245,5 62341815 18 15,8 324,1 62342515 25 19,2 441,8 62343015 30 19,8 514,5 62343415 34 21,4 581,2 62344015 40 23,1 669,4 62344115 41 23,1 683,8 62346115 61 27,1 992,6 71 92 113 139 178 236 259 272 313 354 464 644 734 835 963 972 1403 item no. copper figure kg/km cable weight ≈ kg/km ® 14 AWG (46/36) • 2,50 mm2 62340225 2 8,3 62340325 3 9,0 62340425 4 9,7 62340525 5 11,0 62340725 7 12,1 62340825 8 14,1 62340925 9 15,2 62341025 10 15,7 62341225 12 16,4 62341825 18 19,3 62342525 25 23,4 63,8 89,4 115,3 151,7 204,1 236,0 260,4 304,8 353,1 513,9 693,5 101 136 168 220 286 346 386 428 493 712 965 ® 12 AWG (52/28) • 4,00 mm2 62340340 3 10,6 62340440 4 11,5 62340540 5 12,8 62340740 7 14,1 146,8 189,5 231,6 312,8 205 256 316 412 ® 10 AWG (78/28) • 6,00 mm2 62340360 3 12,3 62340460 4 13,6 62340560 5 15,1 208,9 270,2 332,3 284 362 449 ® 8 AWG (77/26) • 10,00 mm2 62340461 4 18,3 62340561 5 20,2 457,8 562,9 636 783 ® 6 AWG (119/26) • 16,00 mm2 62340462 4 22,2 outer-ø ± 5% mm 706,7 927 ® 4 AWG (196/26) • 25,00 mm2 62340463 4 27,4 1074,8 1450 ® 2 AWG (280/26) • 35,00 mm2 62340464 4 31,3 1471,8 1959 Other dimensions and colours are possible on request. q www.sab-cable.com no. of cores Also available with inner sheath! CABLES FOR RAILWAY TECHNOLOGY 0,6/1 kV SA 810 FRNC Motor connection cable with numbered cores Motor connection cable with numbered cores, SA 812 C FRNC inner sheath and overall copper screen 3 BRÖCKSKES · D-VIERSEN · S A 812 C FRNC rf 0,6/1 kV 7 x 1 Marking for X A 812 C FRNC 68120715: S BRÖCKSKES · D-VIERSEN · X A 812 C FRNC rf 0,6/1 kV 7 x 1,5 mm2 C Construction: Conductor: Technical data: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 Nominal voltage: Uo/U 0.6/1 kV Testing voltage U: 4000 V acc. to DIN VDE 0281 part 2 + HD 21.2 C A 812 C FRNC: core/screen 2000 V Insulation: A Colour code: black cores with consecutive numbers acc. to EN 50334; green-yellow earth wire from 3 cores Min. bending radius fixed laying: flexible application: C A 810 FRNC: 4xd 6xd Stranding: in layers Inner sheath: C A 812 C FRNC: A Temperature range fixed laying: flexible application: -40/+85 °C -30/+85 °C C A 812 C FRNC: tinned copper braiding Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Screen: Fire performance: Sheath material: A Sheath colour: grey (RAL 7000) C A 812 C FRNC: 5xd 10 x d Outstanding features: Smoke density: No flame propagation acc. to IEC 60332 + EN 50266 cat. C resp. D. Flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2. in compliance with IEC 60754-2 and EN 50267-2-2 + VDE 0482 part 267-2-2 no development of corrosive conflagration gases acc. to IEC 61034 + EN 61034 ® halogen-free Flexibility: good ® no flame propagation ® flame retardant and self-extinguishing Absence of harmful substances: acc. to RoHS directive of the European Union ® C A 812 C FRNC: good EMC characteristics* Corrosiveness of conflagration gases: * Copper braiding should be connected circularly to optimize * the EMC characteristics x A 810 FRNC item no. 68100315 68100415 68100515 68100715 68100325 68100425 68100525 68100725 68100340 68100440 68100540 68100740 68100360 68100460 no. of cores x cross section n x mm2 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 3 x 1,50 4 x 1,50 5 x 1,50 7 x 1,50 3 x 2,50 4 x 2,50 5 x 2,50 7 x 2,50 3 x 4,00 4 x 4,00 5 x 4,00 7 x 4,00 3 x 6,00 4 x 6,00 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,31 0,31 0,31 0,31 0,31 0,31 9,4 10,1 11,0 11,9 10,6 11,5 12,6 13,8 11,9 13,2 14,3 15,7 13,3 14,3 43,2 57,6 72,0 100,8 72,0 96,0 120,0 168,0 115,2 153,6 192,0 268,8 172,8 230,4 127 149 176 215 173 206 245 309 234 286 337 435 308 373 item no. 68100560 68100760 68100370 68100470 68100570 68100770 68100380 68100480 68100580 68100780 68100390 68100490 68100590 68100790 no. of cores x cross section n x mm2 largest single wire ø mm outer-ø ± 5% mm 5 x 6,00 7 x 6,00 3 x 10,0 4 x 10,0 5 x 10,0 7 x 10,0 3 x 16,0 4 x 16,0 5 x 16,0 7 x 16,0 3 x 25,0 4 x 25,0 5 x 25,0 7 x 25,0 0,31 0,31 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 15,8 17,2 18,3 20,0 21,9 23,9 21,5 23,5 25,9 28,3 25,9 28,4 31,4 34,4 copper figure kg/km 288,0 403,2 288,0 384,0 480,0 672,0 460,8 614,4 768,0 1075,2 720,0 960,0 1200,0 1680,0 cable weight ≈ kg/km 448 579 583 709 846 1082 823 1007 1232 1585 1265 1557 1878 2445 Other dimensions and colours are possible on request. x A 812 C FRNC item no. 68120315 68120415 68120715 68120325 68120425 68120525 68120725 68120440 68120740 68120360 68120460 68120760 no. of cores x cross section n x mm2 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 3 x 1,50 4 x 1,50 7 x 1,50 3 x 2,50 4 x 2,50 5 x 2,50 7 x 2,50 4 x 4,00 7 x 4,00 3 x 6,00 4 x 6,00 7 x 6,00 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,31 0,31 0,31 0,31 0,31 11,3 12,0 13,8 12,6 13,5 15,0 16,2 16,3 18,0 15,1 16,7 19,9 90,9 111,7 160,8 126,5 155,8 216,9 266,9 251,6 379,9 270,0 328,8 528,3 202 226 312 258 298 373 437 454 589 426 516 777 item no. 68120370 68120470 68120570 68120770 68120380 68120480 68120580 68120780 68120390 68120490 68120590 no. of cores x cross section n x mm2 largest single wire ø mm outer-ø ± 5% mm 3 x 10,0 4 x 10,0 5 x 10,0 7 x 10,0 3 x 16,0 4 x 16,0 5 x 16,0 7 x 16,0 3 x 25,0 4 x 25,0 5 x 25,0 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 0,41 19,4 21,0 22,8 25,1 22,4 24,7 27,0 29,7 26,7 29,4 32,3 copper figure kg/km 412,3 522,4 645,5 842,0 601,9 783,4 942,8 1274,0 894,0 1157,7 1413,6 cable weight ≈ kg/km 614 746 916 1154 827 1055 1291 1661 1188 1510 1862 Other dimensions and colours are possible on request. www.sab-cable.com 25 HYBRID AND SPECIAL CABLES SPECIAL CABLES YOUR PROBLEM IS OUR CHALLENGE. Technical problems often arise that can not be solved properly by standard cables. Being a customer of S BRÖCKSKES, you have the right to get the best solution. We are your specialist for hybrid and special cables in railway technologies. No matter whether a cable of our standard range is to be modified or a completely new cable is to be constructed: we will work together with you intensively in order to realise your requests and needs. Anyway, you will profit from our variedness and flexibility, that besides our wide standard product range of cables count among the special strengths of our company. We produce nearly every type of special cable for you already with minimum quantities of 500 m, in certain dimensions already 100 m – exactly according 26 www.sab-cable.com to your individual construction demands. Please give us your requested details, such as: 4 conductor material 4 number of cores 4 cross sections 4 colours 4 outer diameter 4 flexibility 4 low and high temperature resistance 4 materials 4 types of screening 4 combined cables 4 technical specifications 4 optical waveguide 4 number of fibres 4 POF (polymeric optical fibres) Of course, we also fulfil other parameters than the above-mentioned. Your requests are always most important and our highly motivated team will meet them applying our comprehensive know-how. By this means you will be able to improve the efficiency of your machines. Are you interested in a special solution? Contact directly our sales team that is supported by sales representatives in many parts of Europe. CABLES FOR RAILWAY TECHNOLOGY CAN-BUS cable Halogen-free combined cable with overall copper screen Coupling cable Torsion able connecting cable 3 CAN-Bus cable CAN-Bus cable Halogen-free combined cable with overall copper screen item no. 63359002 cross section: 2 x 2 x 0,50 mm2 + 4 x 0,50 mm2 + 2 x 0,50 mm2 Coupling cable Coupling cable item no. 07909008 cross section: 33 x 1,5 mm2 + 3 x 10,0 mm2 + 4 x (2 x 1,5) mm2 Construction: Conductor: Torsion able connecting cable Construction: tinned copper strands, fine wires with reference to DIN VDE 0812 Conductor: special copper, fine wires Insulation: A thermoplastic material and 02YI1 acc. to DIN VDE 0819 part 103 (for 2 x 0.50 mm2) Insulation: TPE Screen: spezial copper braid, optical coverage ≥ 85% Screen: tinned copper braid, optical coverage ≥ 85% Sheath material: special PUR Sheath colour: black (RAL 9005) Sheath material: A thermoplastic material Sheath colour: black (RAL 9005) Marking: S BRÖCKSKES · D-VIERSEN · SO. A CAN-BUS-LEITUNG Technical data: Peak operating voltage: max. 450 V Testing voltage: core/core 1000 V (DC) core/screen 1500 V (DC) Technical data: Nominal voltage: 1,50 mm2: Uo/U 0,6/1,0 kV 10,0 mm2: Uo/U 1,8/3,0 kV Testing voltage: core/core 1,50 mm2: 4000 V, 10,0 mm2: 12000 V core/screen 1,50 mm2: 2000 V, 10,0 mm2: 6000 V Min. bending radius flexible application: 10 x d Temperature range fixed laying: flexible application: -40/+70 °C -30/+70 °C Min. bending radius flexible application: 10 x d Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Fire performance: No flame propagation acc. to IEC 60332 + EN 50266 category C resp. D. Flame retardant and self-extinguishing acc. to IEC 60332-1-2 and EN 60332-1-2. Temperature range fixed laying: flexible application: -50/+90 °C -40/+90 °C Absence of harmful substances: as acc. to RoHS directive of the European Union Characteristic impedance: acc. to VDE 0472 part 516 at 1 Mhz: 120 Ω ± 10% (CAN-Bus) Image attenuation constant: acc. to VDE 0472 part 515 at 1 Mhz: approx. 1.5 dB/100 m (CAN-Bus) Mutual capacitance: acc. to VDE 0472 part 504 test method: approx. 15 nF/km (CAN-Bus) Oil resistance: acc. to EN 60811-2-1 section 10 and VDE 0473 part 811-2-1 section 10 Absence of harmful substances: as acc. to RoHS directive of the European Union www.sab-cable.com 27 CABLES FOR RAILWAY TECHNOLOGY BA 883 Ö dreh- und torsionsfähige Anschlussleitung 3 For the use in rail vehicles, e.g. bogies and boxes also possible without earth wire q Also possible without earth wire! Construction: Conductor: Technical data: tinned copper strands, acc. to IEC 60228. EN 60228, DIN VDE 0295 class 6 Nominal voltage: Uo/U 300/500 V Testing voltage: core/core 2000 V Insulation: TPE Colour code: black cores with consecutive numbers acc. to DIN VDE 50334 green-yellow earth wire from 3 cores Min. bending radius fixed laying: flexible application: 4xd 6xd Stranding: in layers Temperature range fixed laying: flexible application: -50/+85 °C -40/+85 °C Inner sheath: A Torsion angle: ± 15° Sheath material: PUR Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Sheath colour: black (RAL 9005) Fire performance: Marking: SAB BRÖCKSKES · D-VIERSEN · A A 833 Ö dimension C UV resistance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2 good item no. 08830215 08830315 08830415 08830715 08831815 no. of cores x cross section n x mm2 2 x 1,50 3 x 1,50 4 x 1,50 7 x 1,50 18 x 1,50 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 0,16 0,16 0,16 0,16 0,16 8,1 8,4 9,0 10,4 15,2 28,8 43,2 57,6 100,8 259,2 92 107 128 189 417 Ozone resistance: good Oil resistance: good Weather resistance: good Absence of harmful substances: acc. to RoHS directive of the European Union item no. 08830325 08830425 08830525 08830725 08830540 no. of cores x cross section n x mm2 largest single wire ø mm outer-ø ± 5% mm copper figure kg/km cable weight ≈ kg/km 3 x 2,50 4 x 2,50 5 x 2,50 7 x 2,50 5 x 4,00 0,16 0,16 0,16 0,16 0,16 9,7 10,5 11,5 12,2 13,6 75,5 100,6 125,8 176,1 192,0 158 192 233 291 335 Other dimensions and colours are possible on request. 28 www.sab-cable.com OUR CABLES AT A GLANCE Conductor Materials n n n n n n n Bare copper Tinned copper Silver plated copper Nickel plated copper Nickel Nickel pure Compensating cable alloys Conductor Sizes n 0,14 mm - 300 mm n variety of stranding styles 2 2 Conductor Count Ranges n unshielded - up to 125 conductors n shielded - up to 100 conductors Temperature Ranges (based on marterial) n Thermoplastic Elastomers -50°C up to +145°C n Besilen /Silicone -40°C up to +220°C n FEP, ETFE, PFA, PTFE -90°C up to +260°C n Halogen-free -50°C up to +220°C ® n Fibreglass up to +600°C Shielding and Braiding Materials Insulation and Jacketing Materials n n n n n n n n n n PVC (varietals) Polyethylene Polypropylene TPE Fibreglass Besilen®/Silicone Pi foil FEP, ETFE, PFA, PTFE A zero halogen Polyurethane n Bare copper n Tinned copper n Galvanized steel n Stainless steel n Aluminium foil n Fibreglass n Aramid Approvals n UL, CSA, JET, CCC, CE, MIL, VDE, <HAR>, IEC, GL, DNV, BV, KR, ABS, NK, RINA, LR, GOST www.sab-cable.com 29 OUR TEMPERATURE MEASUREMENT AT A GLANCE Protecting armatures and gauge slides n Immersion protecting armatures Temperature measurement in plastics processing industry/Hot runner technique n Screwed protecting armatures n Hot runner mineral insulated thermocouples n Welding protecting armatures, etc. n Plug-in thermocouples n Molten mass thermocouples, etc. Temperature measurement in test vehicles n Thermo 8-plug connector Probe with stainless steel sleeve n Dipstick thermocouples n available as thermocouple n Thermocouples for cooling water tube applications, etc. n available as resistance thermometer Mineral insulated thermocouples/ Mineral insulated resistance thermometers Compensating and extension cables n with fixed connecting cable n with bare connection endsn n with thermo-plug/miniature plug, etc. n Compensating and extension cables for thermocouples n Connection cables for resistance thermometers, etc. Accessories n Clamping screw connections n Flanges n Screw sockets n Connection heads n Welding protecting tubes n Transmitters n Thermo-plugs/sockets n Screw-in nipples n Miniature plugs/sockets 30 www.sab-cable.com CABLE HARNESSING B HELIX CABLES Cable harnessing Due to the good co-operation with our customers we get continuously new ideas. Therefore, S BRÖCKSKES has enlarged the product range by the field of cable and wire harnessing. No matter whether you need cable looms, assembled single conductors or cables – S BRÖCKSKES offers a wide range of products, especially adjusted to your demands and specifications. There are many possibilities in use of assembled cables. Some of these applications are in the car manufacturing industry, machine and industrial plant construction, control engineering, manufacturing of house hold appliances. Connection possibilities of the large variety of connectors and sling parts offer efficient and cost saving solutions. The variety of possible uses of materials that are processed by S BRÖCKSKES at present: 4 PUR (polyurethane) 4 TPE 4 Besilen® (silicone) 4 PVC (polyvinyl chloride) 4 A (halogen-free) 4 ETFE, FEP, PFA 4 Special materials (fibre glass, Pi foil, Stex etc.) … also offer a wide range of applications in industry. Please do not hesitate to contact our specialists, who will help you with an individual advice fitting to your application. . S helix cables By a special method cables can be transferred from their straight form to a curling form. According to the application the cable can be adjusted to your demands and specifications. It is possible to make helix cables of both, PVC as well as PUR PUR sheathed cables. You can also buy screened helix cables from us. PVC helix cables can be used as extension or connection cables. These cost saving cables are used if there is no continuous restoring force demanded, e.g. for lamps or electrical appliances. PUR helix cables are used for very high requests on the quality of the cable. The pull-off length of these cables is approximately 4:1 and they have a good restoring force as well. For this reason these cables are used e.g. material handling appliances, in machines and on gates. The helical direction is dependent on the stranding direction of a cable. Helical direction c left (counter-clockwirse) Helical direction c right (clockwise) www.sab-cable.com 31 S B R Ö C KS K E S G M B H & C O . KG G R E F R AT H E R ST R . 20 4 - 212 B 4174 9 V I E R S E N · G E R M A N Y T E L .: +4 9/2162/8 9 8-0 FA X : +4 9/2162/8 9 8-101 W W W.S A B -WO R L DW I D E .C O M 09/2016 I N F O @S A B -B R O E C KS K E S .D E
© Copyright 2026 Paperzz